1. Yoshinobu Onuma

    0 Comments Leave a Comment

    1-15 of 82 1 2 3 4 5 6 »
    1. Mentioned In 82 Articles

    2. Neointimal characteristics comparison between biodegradable-polymer and durable-polymer drug-eluting stents: 3-month follow-up optical coherence tomography light property analysis from the RESTORE registry

      Neointimal characteristics comparison between biodegradable-polymer and durable-polymer drug-eluting stents: 3-month follow-up optical coherence tomography light property analysis from the RESTORE registry
      We aimed to quantitatively assess a possible difference of the neointimal quality between biodegradable polymer- (BP-) and durable polymer drug-eluting stents (DP-DESs). We conducted a single-center all-comer prospective cohort study: the RESTORE registry (UMIN000033009). All patients who received successful OCT examination at planned 3-month follow-up after DES implantation were analyzed. Study population was divided into 2 groups, BP-DES versus DP-DES groups. We evaluated standard OCT variables, coverage percent, and the ...
      Read Full Article
    3. Optical coherence tomography enables more accurate detection of functionally significant intermediate non-left main coronary artery stenoses than intravascular ultrasound: A meta-analysis of 6919 patients and 7537 lesions

      Optical coherence tomography enables more accurate detection of functionally significant intermediate non-left main coronary artery stenoses than intravascular ultrasound: A meta-analysis of 6919 patients and 7537 lesions
      Objective Fractional flow reserve (FFR) is regarded as the gold standard for the physiological assessment of intermediate coronary artery stenoses. However, FFR does not allow assessment of plaque morphology and lesion geometry. Intracoronary imaging techniques such as intravascular ultrasound (IVUS) and optical coherence tomography (OCT) can help treatment planning by optimising stent implantation, which can improve patient outcomes. The aim of this meta-analysis is to compare the efficacy of IVUS ...
      Read Full Article
    4. Optical coherence tomography substudy of a prospective multicentre randomised post-market trial to assess the safety and effectiveness of the Firehawk cobalt-chromium coronary stent (rapamycin target-eluting) system for the treatment of atherosclerotic le

      Optical coherence tomography substudy of a prospective multicentre randomised post-market trial to assess the safety and effectiveness of the Firehawk cobalt-chromium coronary stent (rapamycin target-eluting) system for the treatment of atherosclerotic le
      Aims: Durable polymer drug-eluting stents (DP-DES) may contribute to persistent inflammation, delayed endothelial healing and subsequent late DES thrombosis. The aim of this optical coherence tomography (OCT) substudy was to compare healing and neointimal coverage of a novel bioabsorbable polymer sirolimus-eluting stent (Firehawk ) (BP-DES) versus the DP-DES (XIENCE) at 90 days in an all-comers patient population. Methods and results: The TARGET All Comers study is a prospective multicentre randomised post-market ...
      Read Full Article
    5. Clinical use of intracoronary imaging. Part 1: guidance and optimization of coronary interventions. An expert consensus document of the European Association of Percutaneous Cardiovascular Interventions

      Clinical use of intracoronary imaging. Part 1: guidance and optimization of coronary interventions. An expert consensus document of the European Association of Percutaneous Cardiovascular Interventions
      his Consensus Document is the first of two reports summarizing the views of an expert panel organized by the European Association of Percutaneous Cardiovascular Interventions (EAPCI) on the clinical use of intracoronary imaging including intravascular ultrasound (IVUS) and optical coherence tomography (OCT). The first document appraises the role of intracoronary imaging to guide percutaneous coronary interventions (PCIs) in clinical practice. Current evidence regarding the impact of intracoronary imaging guidance on ...
      Read Full Article
    6. Multimodality Imaging to Detect Vulnerable Plaque in Coronary Arteries and Its Clinical Application (Book Chapter)

      Multimodality Imaging to Detect Vulnerable Plaque in Coronary Arteries and Its Clinical Application (Book Chapter)
      Postmortem studies have described the association between the thin-cap fibroatheroma (TCFA) and the occurrence of acute coronary syndrome (ACS). Both noninvasive and invasive techniques have been refined and used as a research tool to visualize the plaque at a high risk of disruption. There has been a considerable effort to develop the imaging modalities that offer detailed visualization of coronary pathology and accurately predict the adverse cardiac outcomes. This chapter ...
      Read Full Article
    7. Quality difference of neointima following the implantation of bioresorbable scaffold and metallic stent in patients with ST elevation myocardial infarction: quantitative assessments by light intensity, light attenuation, and backscatter on optical coheren

      Quality difference of neointima following the implantation of bioresorbable scaffold and metallic stent in patients with ST elevation myocardial infarction: quantitative assessments by light intensity, light attenuation, and backscatter on optical coheren
      Aims: We aimed to assess possible difference of the neointimal quality after everolimus-eluting bioresorbable scaffold (BVS) implantation in comparison with cobalt chromium everolimus-eluting scaffold (CoCr-EES) by optical frequency domain imaging (OFDI). Methods and results: This study is a post-hoc analysis of TROFI II trial assessing neointimal quality 6-month after the implantation of BVS(N=82) and CoCr-EES(N=87) in STEMI patients. Neointimal light property analysis by OFDI full-automatically computed ...
      Read Full Article
    8. Coronary calcification as a mechanism of plaque/media shrinkage in vessels treated with bioresorbable vascular scaffold: A multimodality intracoronary imaging study

      Coronary calcification as a mechanism of plaque/media shrinkage in vessels treated with bioresorbable vascular scaffold: A multimodality intracoronary imaging study
      Background and aims Whether coronary calcification is correlated with plaque/media shrinkage (PS) remains unclear. The aim of this study was to assess the relationship between the calcification process and PS, combining serial optical coherence tomography (OCT) and intravascular ultrasound (IVUS) in vessels treated with bioresorbable vascular scaffolds (BVS). Methods In 15 patients (16 vessels), OCT and IVUS images were matched using anatomic landmarks at post-procedure and five years. PS ...
      Read Full Article
    9. Serial Assessment of Tissue Precursors and Progression of Coronary Calcification Analyzed by Fusion of IVUS and OCT

      Serial Assessment of Tissue Precursors and Progression of Coronary Calcification Analyzed by Fusion of IVUS and OCT
      Objectives The aim of this study was to assess calcium growth with fused grayscale intravascular ultrasound (IVUS), IVUSvirtual histology, and optical coherence tomography (OCT) from baseline to 5-year follow-up in patients treated with bioresorbable vascular scaffolds. Background IVUS and OCT have individual strengths in assessing plaque composition and volume. Fusion of images obtained using these methods could potentially aid in coronary plaque assessment. Methods Anatomic landmarks and endoluminal radiopaque markers ...
      Read Full Article
    10. Effect of Post-Dilatation Following Primary PCI With Everolimus-Eluting Bioresorbable Scaffold Versus Everolimus-Eluting Metallic Stent Implantation: An Angiographic and Optical Coherence Tomography TROFI II Substudy

      Effect of Post-Dilatation Following Primary PCI With Everolimus-Eluting Bioresorbable Scaffold Versus Everolimus-Eluting Metallic Stent Implantation: An Angiographic and Optical Coherence Tomography TROFI II Substudy
      Objectives This study sought to investigate the effect of post-dilatation on angiographic and intracoronary imaging parameters in the setting of primary percutaneous coronary intervention comparing the everolimus-eluting bioresorbable scaffold (BRS) with the everolimus-eluting metallic stent (EES). Background Routine post-dilatation of BRS has been suggested to improve post-procedural angiographic and subsequent device-related clinical outcomes. Methods In the ABSORB STEMI TROFI II trial, 191 patients with ST-segment elevation myocardial infarction were randomly ...
      Read Full Article
    11. Tissue characterization with depth-resolved attenuation coefficient and backscatter term in intravascular optical coherence tomography images

      Tissue characterization with depth-resolved attenuation coefficient and backscatter term in intravascular optical coherence tomography images
      An important application of intravascular optical coherence tomography (IVOCT) for atherosclerotic tissue analysis is using it to estimate attenuation and backscatter coefficients. This work aims at exploring the potential of the attenuation coefficient, a proposed backscatter term, and image intensities in distinguishing different atherosclerotic tissue types with a robust implementation of depth-resolved (DR) approach. Therefore, the DR model is introduced to estimate the attenuation coefficient and further extended to estimate ...
      Read Full Article
    12. Serial 5-Year Evaluation of Side Branches Jailed by Bioresorbable Vascular Scaffolds Using 3-Dimensional Optical Coherence Tomography

      Serial 5-Year Evaluation of Side Branches Jailed by Bioresorbable Vascular Scaffolds Using 3-Dimensional Optical Coherence Tomography
      Background The long-term fate of Absorb bioresorbable vascular scaffold (Abbott Vascular, Santa Clara, CA) struts jailing side branch ostia has not been clarified. We therefore evaluate serially (post-procedure and at 6 months, 1, 2, 3, and 5 years) the appearance and fate of jailed Absorb bioresorbable vascular scaffold struts. Methods and Results We performed 3-dimensional optical coherence tomographic analysis of the ABSORB Cohort B trial (A Clinical Evaluation of the ...
      Read Full Article
    13. Report of an ESC-EAPCI Task Force on the evaluation and use of bioresorbable scaffolds for percutaneous coronary intervention: executive summary

      Report of an ESC-EAPCI Task Force on the evaluation and use of bioresorbable scaffolds for percutaneous coronary intervention: executive summary
      BRS require careful lesion assessment, to determine the need and extent of lesion preparation, as well as to select the appropriate size and length of the device. The use of pre-and post-procedural intracoronary imaging (Intravascular ultrasound, optical coherence tomography), as well as online quantitative coronary angiography, is encouraged to optimize device implantation. The use of BRS in heavily calcified vessels is strongly discouraged. Bioresorbable scaffolds should be avoided in stenoses ...
      Read Full Article
    14. Hemodynamic analysis of a novel bioresorbable scaffold in porcine coronary artery model

      Hemodynamic analysis of a novel bioresorbable scaffold in porcine coronary artery model
      Background The shear stress distribution assessment can provide useful insights for the hemodynamic performance of the implanted stent/scaffold. Our aim was to investigate the effect of a novel bioresorbable scaffold, Mirage on local hemodynamics in animal models. Method The main epicardial coronary arteries of 7 healthy mini-pigs were implanted with 11 Mirage Microfiber sirolimus-eluting Bioresorbable Scaffolds (MMSES). Optical coherence tomography (OCT) was performed post scaffold implantation and the obtained ...
      Read Full Article
    15. Imaging outcomes of bioresorbable scaffold overlap: an optical coherence tomography analysis from the ABSORB EXTEND trial

      Imaging outcomes of bioresorbable scaffold overlap: an optical coherence tomography analysis from the ABSORB EXTEND trial
      Aims: The purpose of this study was to assess the vascular response and vessel healing of overlapped Absorb scaffolds (Abbott Vascular, Santa Clara, CA, USA) compared to non-overlapped devices in human coronary arteries as assessed by optical coherence tomography (OCT) in the same treated segment. Methods and results: The ABSORB EXTEND (NCT01023789) trial is a prospective, single-arm, openlabel clinical study which enrolled 800 patients. The planned overlap OCT subgroup in ...
      Read Full Article
    16. 1-15 of 82 1 2 3 4 5 6 »
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. About Yoshinobu Onuma

    Yoshinobu Onuma, MD, is at the Thoraxcenter at Eramus Medical Center