1. Yoshiki Matsuo

    0 Comments Leave a Comment

    1-15 of 34 1 2 3 »
    1. Mentioned In 34 Articles

    2. Intracoronary pressure increase due to contrast injection for optical coherence tomography imaging

      Intracoronary pressure increase due to contrast injection for optical coherence tomography imaging
      Background Optical coherence tomography (OCT) requires intracoronary injection of contrast media to remove blood from the field of view during image acquisition. Contrast injection may cause a temporal increase in intracoronary pressure. The aim of this study was to compare the intracoronary pressure during contrast injection between OCT and coronary angiography . Methods We measured intracoronary pressure by using a pressure guidewire during contrast injection for OCT and angiography in 30 ...
      Read Full Article
    3. Imaging assessment and accuracy in coronary artery autopsy: comparison of frequency-domain optical coherence tomography with intravascular ultrasound and histology

      Imaging assessment and accuracy in coronary artery autopsy: comparison of frequency-domain optical coherence tomography with intravascular ultrasound and histology
      ptical coherence tomography (OCT) is a coronary artery imaging technique with high resolution. Second-generation frequency-domain OCT (FD-OCT) technology allows safer and faster clinical application compared with first-generation time-domain OCT (TD-OCT). Only limited validation studies compare FD-OCT with other modes of analysis: histology, which is the current gold standard, and intravascular ultrasound (IVUS). This study therefore aims to demonstrate the accuracy of FD-OCT images compared with IVUS and histology. FD-OCT and ...
      Read Full Article
    4. Stabilization of High Risk Coronary Plaque on Optical Coherence Tomography and Near-Infrared Spectroscopy by Intensive Lipid-Lowering Therapy With Proprotein Convertase Subtilisin/Kexin Type 9 (PCSK9) Inhibitor

      Stabilization of High Risk Coronary Plaque on Optical Coherence Tomography and Near-Infrared Spectroscopy by Intensive Lipid-Lowering Therapy With Proprotein Convertase Subtilisin/Kexin Type 9 (PCSK9) Inhibitor
      A 70-year-old woman with hypertension and dyslipidemia underwent drug-eluting stent implantation in the mid-left anterior descending artery (LAD) due to acute coronary syndrome (ACS). Optical coherence tomography (OCT) during the index procedure showed lipid-rich plaque in non-culprit lesions of the proximal LAD and mid-right coronary artery (Figure B,E). Near-infrared spectroscopy-intravascular ultrasound (NIRS-IVUS) showed plaque with high lipid burden in both sites (Figure C,F). Intensive lipid-lowering therapy with combined ...
      Read Full Article
    5. In vivo optical coherence tomography imaging and histopathology of healed coronary plaques

      In vivo optical coherence tomography imaging and histopathology of healed coronary plaques
      Background and aims The aims of this study were to assess agreement between optical coherence tomography (OCT) and histopathology for healed coronary plaques (HCPs) in human coronary arteries ex vivo , and to evaluate the prevalence and characteristics of HCPs in vivo . Methods Ex vivo OCT images were co-registered with histopathology in 144 cross-sections with 50% stenosis. Of these, 30 randomly selected pairs were employed to define morphological features of OCT ...
      Read Full Article
    6. Effect of Early Pitavastatin Therapy on Coronary Fibrous-Cap Thickness Assessed by Optical Coherence Tomography in Patients With Acute Coronary Syndrome : The ESCORT Study

      Effect of Early Pitavastatin Therapy on Coronary Fibrous-Cap Thickness Assessed by Optical Coherence Tomography in Patients With Acute Coronary Syndrome : The ESCORT Study
      ...Imaging, Volume null, Issue null, Page null Tsuyoshi Nishiguchi, Takashi Kubo, Takashi Tanimoto, Yasushi Ino, Yoshiki Matsuo, Takashi Yamano, Kosei Terada, Hiroki Emori, Yosuke Katayama, Akira Taruya You can get the full...
      Read Full Article
    7. Impact of Plaque Rupture Detected by Optical Coherence Tomography on Transmural Extent of Infarction After Successful Stenting in ST-Segment Elevation Acute Myocardial Infarction

      Impact of Plaque Rupture Detected by Optical Coherence Tomography on Transmural Extent of Infarction After Successful Stenting in ST-Segment Elevation Acute Myocardial Infarction
      bjectives The aim of the present study was to investigate the association between plaque rupture (PR) assessed by optical coherence tomography (OCT), and the transmural extent of infarction (TEI) assessed by contrast-enhanced cardiac magnetic resonance imaging (CE-CMR) in ST-segment elevation myocardial infarction (STEMI) patients after primary percutaneous coronary intervention (PCI). Background PR is associated with larger infarct size as assessed by cardiac enzymes in STEMI patients. CE-CMR is a favorable ...
      Read Full Article
    8. Optical Coherence Tomography Predictors for Edge Restenosis After Everolimus-Eluting Stent Implantation

      Optical Coherence Tomography Predictors for Edge Restenosis After Everolimus-Eluting Stent Implantation
      Background Stent edge restenosis (SER) remains a potential limitation of drug-eluting stents. The aim of this study was to determine optical coherence tomography (OCT) predictors for angiographic late SER after everolimus-eluting stent implantation. Methods and Results We retrospectively analyzed 319 patients who underwent OCT immediately after everolimus-eluting stent implantation and scheduled 9- to 12-month follow-up angiography. The binary angiographic SER rate was 10% (32/319) in the patients, 8.4 ...
      Read Full Article
    9. Assessment of Vascular Response after Stent Implantation by Intracoronary Optical Coherence Tomograph

      Assessment of Vascular Response after Stent Implantation by Intracoronary Optical Coherence Tomograph
      Optical coherence tomography (OCT) is a high resolution (10-20 m) imaging modality that provides microscopic visualization of the coronary artery including vascular response after stent implantation. Compared to conventional intravascular ultrasound, OCT can more clearly identify findings immediately after stent implantation, such as tissue protrusion, stent edge dissection, and incomplete stent strut apposition. Furthermore, OCT allows clinicians to accurately assess the late acquired stent malapposition and strut coverage which could ...
      Read Full Article
    10. Reduction of in-stent thrombus immediately after percutaneous coronary intervention by pretreatment with prasugrel compared with clopidogrel: An optical coherence tomography study

      Reduction of in-stent thrombus immediately after percutaneous coronary intervention by pretreatment with prasugrel compared with clopidogrel: An optical coherence tomography study
      Background Prasugrel is a new-generation thienopyridine antiplatelet agent that provides more consistent and prompt platelet inhibition than clopidogrel. The aim of this study was to compare in-stent thrombus inhibition effect of pretreatment with prasugrel and clopidogrel by using optical coherence tomography (OCT) immediately after percutaneous coronary intervention (PCI) for acute coronary syndrome (ACS). Methods We performed OCT immediately after PCI in 108 ACS patients pretreated with either prasugrel ( n = 51 ...
      Read Full Article
    11. The use of optical coherence tomography in acute coronary syndrome

      The use of optical coherence tomography in acute coronary syndrome
      Optical coherence tomography (OCT) is an intracoronary imaging modality which utilizes near-infrared light to provide high-resolution cross-sectional in-vivo images of the coronary artery. OCT imaging technique enables detailed evaluation of plaque morphology in patients with acute coronary syndrome and helps to understand the underlying mechanisms including plaque rupture, plaque erosion, and calcified nodule. It is useful to optimize percutaneous coronary intervention, and evaluate vascular response to coronary intervention and pharmacological ...
      Read Full Article
    12. Optical coherence tomography assessment of efficacy of thrombus aspiration in patients undergoing a primary percutaneous coronary intervention for acute ST-elevation myocardial infarction

      Optical coherence tomography assessment of efficacy of thrombus aspiration in patients undergoing a primary percutaneous coronary intervention for acute ST-elevation myocardial infarction
      Objective: We used optical coherence tomography (OCT) to assess the impact of thrombus aspiration before angioplasty on poststenting tissue protrusions in patients undergoing a primary percutaneous coronary intervention (PCI) for ST-segment elevation myocardial infarction (STEMI). Methods and results: A total of 188 patients with STEMI who underwent thrombus-aspiration PCI ( n =113) or standard PCI ( n =75) were examined in this study. OCT was performed immediately after primary PCI to assess ...
      Read Full Article
    13. Optical coherence tomography assessment of efficacy of thrombus aspiration in patients undergoing a primary percutaneous coronary intervention for acute ST-elevation myocardial infarction

      Optical coherence tomography assessment of efficacy of thrombus aspiration in patients undergoing a primary percutaneous coronary intervention for acute ST-elevation myocardial infarction
      Objective: We used optical coherence tomography (OCT) to assess the impact of thrombus aspiration before angioplasty on poststenting tissue protrusions in patients undergoing a primary percutaneous coronary intervention (PCI) for ST-segment elevation myocardial infarction (STEMI). Methods and results: A total of 188 patients with STEMI who underwent thrombus-aspiration PCI ( n =113) or standard PCI ( n =75) were examined in this study. OCT was performed immediately after primary PCI to assess ...
      Read Full Article
    14. Optimal threshold of postintervention minimum stent area to predict in-stent restenosis in small coronary arteries: An optical coherence tomography analysis

      Optimal threshold of postintervention minimum stent area to predict in-stent restenosis in small coronary arteries: An optical coherence tomography analysis
      Objectives The aim of this study was to determine the best threshold of postintervention minimum stent area (MSA) assessed by optical coherence tomography (OCT) to predict long-term in-stent restenosis (ISR) for 2.5 mm-diameter everolimus-eluting stents (EES). Background Percutaneous coronary intervention (PCI) for small coronary arteries remains challenging. Stent underexpansion is a strong predictor of late ISR. Methods We performed a retrospective analysis of 69 lesions in 69 patients undergoing ...
      Read Full Article
    15. 1-15 of 34 1 2 3 »
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. About Yoshiki Matsuo

    Yoshiki Matsuo is with the Division of Cardiology at Wakayama Medical University and the Social Insurance Kinan Hospital in Wakayama Japan.