1. Yonghong He

    0 Comments Leave a Comment

    1-15 of 34 1 2 3 »
    1. Mentioned In 34 Articles

    2. Velocity range estimation for liquid flow based on optical micro-angiography

      Velocity range estimation for liquid flow based on optical micro-angiography
      Optical micro-angiography (OMAG) is widely used in vivo imaging due to its non-invasive and highly sensitive measurements. It can effectively distinguish flowing and stationary particles for applications such as micro-size blood vessel. However, the detectable flow velocity of OMAG is restricted by the system parameters. Their relationship is usually unknown and thus increase the difficulty of OMAG application on liquid flow measurements. This study for the first time proposes a ...
      Read Full Article
    3. Detection of Simulated Periradicular Lesions in Porcine Bone by Optical Coherence Tomography

      Detection of Simulated Periradicular Lesions in Porcine Bone by Optical Coherence Tomography
      Introduction The accurate detection of periradicular lesions located under a nonperforated cortical plate poses a challenge in endodontic microsurgery. Optical coherence tomography (OCT) is a noninvasive imaging method that has been successfully used in many dental applications. In this study, we investigated if spectral-domain OCT (SD-OCT) could be used to determine simulated periradicular lesions. Methods Twenty-eight cavities with different depths were prepared on bone plates obtained from 5 porcine mandibles ...
      Read Full Article
    4. Image-guided vibrometry system integrated with spectral- and time-domain optical coherence tomography

      Image-guided vibrometry system integrated with spectral- and time-domain optical coherence tomography
      Vibrometry using optical coherence tomography (OCT) can provide valuable information for investigating either the mechanical properties or the physiological function of biological tissues, especially the hearing organs. Real-time imaging of the measured tissues provides structure imaging and spatial guidance for and is thus highly demanded by such vibrometry. However, the traditional time-domain OCT (TD-OCT) systems, although capable of subnanometric vibrometry at large ranges of frequencies, are unable to offer an ...
      Read Full Article
    5. Effects of titanium dioxide nanoparticles coupled with diode laser on optical properties of in vitro normal and cancerous human lung tissues studied with optical coherence tomography and diffuse reflectance spectra

      Effects of titanium dioxide nanoparticles coupled with diode laser on optical properties of in vitro normal and cancerous human lung tissues studied with optical coherence tomography and diffuse reflectance spectra
      The objective is to investigate the effects of two different sized (60 and 100 nm) titanium dioxide ( TiO 2 ) nanoparticles (NPs) penetration and accumulation in in vitro human normal lung (NL) tissue, lung squamous cell carcinoma (LSCC) tissue, and 650-nm diode laser-pretreated tissue on their optical properties studied with optical coherence tomography monitoring and diffuse reflectance (DR) spectra measurement. As with TiO 2 NPs penetrating into the tissues, the intensities ...
      Read Full Article
    6. Influence of nanoparticles accumulation on optical properties of human normal and cancerous liver tissue in vitro estimated by OCT

      Influence of nanoparticles accumulation on optical properties of human normal and cancerous liver tissue in vitro estimated by OCT
      In this work, the potential use of nanoparticles as contrast agents by using spectral domain optical coherence tomography (SD-OCT) in liver tissue was demonstrated. Gold nanoparticles (average size of 25 and 70nm), were studied in human normal and cancerous liver tissues in vitro , respectively. Each sample was monitored with SD-OCT functional imaging for 240min. Continuous OCT monitoring showed that, after application of gold nanoparticles, the OCT signal intensities of normal ...
      Read Full Article
    7. Monitoring of permeability of different analytes in human normal and cancerous bladder tissues invitro using optical coherence tomography

      Monitoring of permeability of different analytes in human normal and cancerous bladder tissues invitro using optical coherence tomography
      We report our preliminary results on quantification of glucose and dimethyl sulfoxide (DMSO) diffusion in normal and cancerous human bladder tissues in vitro by using a spectral domain optical coherence tomography (SD-OCT). The permeability coefficients (PCs) of a 30% aqueous solution of glucose are found to be (7.92 0.81) 10 -6 cm s -1 and (1.19 0.13) 10 -5 cm s -1 in normal and cancerous ...
      Read Full Article
    8. In vitro assessment of effects of hyperglycemia on the optical properties of blood during coagulation using optical coherence tomography

      In vitro assessment of effects of hyperglycemia on the optical properties of blood during coagulation using optical coherence tomography
      No published reports have demonstrated the capability of the optical coherence tomography technique for quantifying the optical coherence tomography signal slope, 1/e light penetration depth, and attenuation coefficient of hyperglycemic blood by an in vitro assessment. The purpose of this study was to investigate the effects of hyperglycemia on optical properties during in vitro blood coagulation by optical coherence tomography. Normal whole blood acted as the control group. After ...
      Read Full Article
    9. Continuous noninvasive monitoring of changes in human skin optical properties during oral intake of different sugars with optical coherence tomography

      Continuous noninvasive monitoring of changes in human skin optical properties during oral intake of different sugars with optical coherence tomography
      ...Liu »View Author Affiliations Yuqing Zhang,^1 Guoyong Wu,^2 Huajiang Wei,^1,^* Zhouyi Guo,^1 Hongqin Yang,^3 Yonghong He,^4 Shusen Xie,^3 and Ying Liu^1 ^1MOE Key Laboratory of Laser Life Science & Institute of Laser ...
      Read Full Article
    10. Assessment of the effects of ultrasound-mediated glucose on permeability of normal, benign, and cancerous human lung tissues with the Fourier-domain optical coherence tomography

      Assessment of the effects of ultrasound-mediated glucose on permeability of normal, benign, and cancerous human lung tissues with the Fourier-domain optical coherence tomography
      The objective of this study was to evaluate the effects of ultrasound-mediated analyte diffusion on permeability of normal, benign, and cancerous human lung tissue in vitro and to find more effective sonophoretic (SP) delivery in combination with the optical clearing agents (OCAs) method to distinguish normal and diseased lung tissues. The permeability coefficients of SP in combination with OCAs diffusion in lung tissue were measured with Fourier-domain optical coherence tomography ...
      Read Full Article
    11. Quantitative measurement on optical attenuation coefficient of cell lines 5-8F and 6-10B using optical coherence tomography

      Quantitative measurement on optical attenuation coefficient of cell lines 5-8F and 6-10B using optical coherence tomography
      Oncogenesis and metastasis of tumor are difficult to detect during the clinic therapy. To explore the optical properties of tumorigenesis and metastasis in nasopharyngeal carcinoma (NPC), we assessed the NPC cell lines 5-8F and 6-10B by optical coherence tomography (OCT): first, the OCT images of the two different types of cell pellets were captured. Second, by fitting Beers law to the averaged A-scans in these OCT datasets, the attenuation coefficients ...
      Read Full Article
    12. Ex vivo determination of glucose permeability and optical attenuation coefficient in normal and adenomatous human colon tissues using spectral domain optical coherence tomography

      Ex vivo determination of glucose permeability and optical attenuation coefficient in normal and adenomatous human colon tissues using spectral domain optical coherence tomography
      Recent reports have suggested that spectral domain optical coherence tomography (SD-OCT) is a useful tool for quantifying the permeability of hyperosmotic agents in various tissues. We report our preliminary results on quantification of glucose diffusion and assessment of the optical attenuation change due to the diffusion of glucose in normal and adenomatous human colon tissues in vitro by using a SD-OCT and then calculated the permeability coefficients (PC) and optical ...
      Read Full Article
    13. Synergistic effect of hyperosmotic agents and sonophoresis on breast tissue optical properties and permeability studied with spectral domain optical coherence tomography

      Synergistic effect of hyperosmotic agents and sonophoresis on breast tissue optical properties and permeability studied with spectral domain optical coherence tomography
      Hyperosmotic agents have shown great potential in tissue optical clearing. However, the low efficiency of the permeation in biological tissues seriously restricts its application in reality. The synergy of sonophoresis as a penetration enhancer and hyperosmotic agents, 20% glucose (G) and 20% mannitol (M), in optical clearing has been investigated by analyzing the variation of the attenuation coefficients and the permeability coefficients. In the sonophoresis experiments, ultrasound (US) was applied ...
      Read Full Article
    14. 1-15 of 34 1 2 3 »
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. About Yonghong He

    Yonghong He is from Graduate School at Shenzhen at Tsinghua University in Guangdong, China.