1. Yasunori Sumi

    0 Comments Leave a Comment

    1-15 of 79 1 2 3 4 5 6 »
    1. Mentioned In 79 Articles

    2. Diagnosis of Occlusal Tooth Wear Using 3D Imaging of Optical Coherence Tomography Ex Vivo

      Diagnosis of Occlusal Tooth Wear Using 3D Imaging of Optical Coherence Tomography Ex Vivo
      The aim of this study was to assess the utility of 3D imaging of optical coherence tomography (OCT) for the diagnosis of occlusal tooth wear ex vivo. Sixty-three extracted human molars with or without visible tooth wear were collected to take digital intraoral radiography and 3D OCT images. The degree of tooth wear was evaluated by 12 examiners and scored using 4-rank scale: 1slight enamel wear; 2distinct enamel wear; 3tooth ...
      Read Full Article
    3. Evaluation of dental caries, tooth crack, and age-related changes in tooth structure using optical coherence tomography

      Evaluation of dental caries, tooth crack, and age-related changes in tooth structure using optical coherence tomography
      Optical coherence tomography (OCT) is an imaging technique that can visualize the internal biological structure without X-ray exposure. Swept-source OCT (SS-OCT) is one of the latest version of OCT, wherein the light source is a tunable laser that sweeps near-infrared wavelength light to achieve real-time imaging. The imaging depth of OCT is highly influenced by the translucency of the medium. The medium that does not transmit light and the deeper ...
      Read Full Article
    4. 3D imaging of proximal caries in posterior teeth using optical coherence tomography

      3D imaging of proximal caries in posterior teeth using optical coherence tomography
      Optical coherence tomography (OCT) can create cross-sectional images of tooth without X-ray exposure. This study aimed to investigate the diagnostic accuracy of 3D imaging of OCT for proximal caries in posterior teeth. Thirty-six human molar teeth with 51 proximal surfaces visibly 6 intact, 16 slightly demineralized, and 29 distinct carious changes were mounted to take digital radiographs and 3D OCT images. The sensitivity, specificity and area under the receiver operating ...
      Read Full Article
    5. Swept-source optical coherence tomographic observation on prevalence and variations of cemento-enamel junction morphology

      Swept-source optical coherence tomographic observation on prevalence and variations of cemento-enamel junction morphology
      To investigate the prevalence of different patterns of cemento-enamel junction (CEJ) morphology under swept-source optical coherence tomography (SS-OCT). One hundred extracted human teeth were used consisting of incisors, premolars, and molars. Each sample was observed for every 500 m circumferentially along CEJ and OCT images of the pattern were noted. Microscopic observations were done for the representative sample using confocal laser scanning microscope (CLSM) and transmission electron microscope (TEM). The ...
      Read Full Article
    6. Method and apparatus for measuring and displaying dental plaque, gingiva, and alveolar bone

      Method and apparatus for measuring and displaying dental plaque, gingiva, and alveolar bone
      A method and an apparatus for measuring and displaying dental plaque are provided, and the method includes the steps of dividing near infrared light output from a light source into measurement light and reference light, applying the measurement light toward a tooth in an oral cavity and scanning the tooth with the measurement light, producing interference light from reflected light and back-scattered light from the tooth and the reference light ...
      Read Full Article
    7. Three-dimensional assessment of proximal contact enamel using optical coherence tomography

      Three-dimensional assessment of proximal contact enamel using optical coherence tomography
      Objective The purpose of this study was to detect and investigate the association of enamel microcracks with demineralization at proximal contact areas of premolars, using 3D swept-source optical coherence tomography (SS-OCT). Methods Extracted maxillary and mandibular premolars (n = 50 each), without any visible tooth cracks, were examined for demineralization of interproximal contact areas, using the International Caries Detection and Assessment System (ICDAS). SS-OCT was used to evaluate demineralization and detect ...
      Read Full Article
    8. Assessment of root caries under wet and dry conditions using swept-source optical coherence tomography (SS-OCT)

      Assessment of root caries under wet and dry conditions using swept-source optical coherence tomography (SS-OCT)
      The purpose of this study was to compare optical properties of root caries under two observing conditions using swept-source optical coherence tomography (SS-OCT). In vitro and natural root caries were observed by SS-OCT under wet and dry conditions, followed by confocal laser scanning microscope (CLSM) and transverse microradiography (TMR). Signal intensity (SI), distance between SI peaks (SI-distance) and optical lesion depth were obtained from OCT. Lesion depth was measured from ...
      Read Full Article
    9. In vitro and clinical evaluation of optical coherence tomography for the detection of subgingival calculus and root cementum

      In vitro and clinical evaluation of optical coherence tomography for the detection of subgingival calculus and root cementum
      This study evaluated the effectiveness of swept-source optical coherence tomography (ss-OCT) for detecting calculus and root cementum during periodontal therapy. Optical coherence tomography (OCT) images were taken before and after removal of subgingival calculus from extracted teeth and compared with non-decalcified histological sections. Porcine gingival sheets of various thicknesses were applied to the root surfaces of extracted teeth with calculus and OCT images were taken. OCT images were also taken ...
      Read Full Article
    10. Resolution characteristics of optical coherence tomography for dental use

      Resolution characteristics of optical coherence tomography for dental use
      OBJECTIVES: The purpose of this study was to clarify resolution characteristics of optical coherence tomography (OCT) for dental use. METHODS: Two types of swept-source OCT machines (SS-OCTs) were employed in this study. To clarify their resolution characteristics, we newly developed a glass chart device with a ladder pattern of wavelengths, which ranged from (4 x 2) m to (1024 x 2) m, as well as a star-target pattern, a grid ...
      Read Full Article
    11. A pilot study to assess the morphology and progression of non-carious cervical lesions

      A pilot study to assess the morphology and progression of non-carious cervical lesions
      Objective This longitudinal pilot study aimed to morphologically and quantitatively investigate the progress of non-carious cervical lesions (NCCLs) by using swept-source optical coherence tomography (SS-OCT). Methods The samples examined comprised sets of NCCL epoxy resin replicas obtained from 10 lesions in 6 patients who attended annual dental visits over 4 or 5 years. SS-OCT images of the replicas were analyzed in terms of the maximum depth (D max ) and corresponding ...
      Read Full Article
    12. Three-Dimensional Analysis of Enamel Crack Behavior Using Optical Coherence Tomography

      Three-Dimensional Analysis of Enamel Crack Behavior Using Optical Coherence Tomography
      The aim of this study was to nondestructively analyze enamel crack behavior on different areas of teeth using 3D swept source-optical coherence tomography (SS-OCT). Ten freshly extracted human teeth of each type on each arch ( n = 80 teeth) were inspected for enamel crack patterns on functional, contact and nonfunctional, or noncontact areas using 3D SS-OCT. The predominant crack pattern for each location on each specimen was noted and analyzed. The ...
      Read Full Article
    13. Optical analysis of enamel and dentin caries in relation to mineral density using swept-source optical coherence tomography

      Optical analysis of enamel and dentin caries in relation to mineral density using swept-source optical coherence tomography
      The aim of this study was to evaluate the signal intensity and signal attenuation of swept source optical coherence tomography (SS-OCT) for dental caries in relation to the variation of mineral density. SS-OCT observation was performed on the enamel and dentin artificial demineralization and on natural caries. The artificial caries model on enamel and dentin surfaces was created using Streptococcus mutans biofilms incubated in an oral biofilm reactor. The lesions ...
      Read Full Article
    14. The effectiveness of optical coherence tomography for evaluating peri-implant tissue: A pilot study

      The effectiveness of optical coherence tomography for evaluating peri-implant tissue: A pilot study
      Purpose Optical coherence tomography (OCT) has been investigated as a novel diagnostic imaging tool. The utilisation of this equipment has been evaluated through several studies in the field of dentistry. The aim of this preliminary study was to determine through basic experiments the effectiveness of OCT in implant dentistry. Materials and Methods To assess detection ability, we captured OCT images of implants in each of the following situations: (1) implants ...
      Read Full Article
    15. Method and apparatus for measuring and displaying dental plaque

      Method and apparatus for measuring and displaying dental plaque
      A method and an apparatus for measuring and displaying dental plaque are provided, and the method includes the steps of dividing near infrared light output from a light source into measurement light and reference light, applying the measurement light toward a tooth in an oral cavity and scanning the tooth with the measurement light, producing interference light from reflected light and back-scattered light from the tooth and the reference light ...
      Read Full Article
    16. Assessment of bacterial demineralization around composite restorations using swept-source optical coherence tomography (SS-OCT)

      Assessment of bacterial demineralization around composite restorations using swept-source optical coherence tomography (SS-OCT)
      Objective To observe the bacterial demineralization of the enamel and dentin around composite restorations bonded with one-step and two-step self-etch adhesive systems using swept-source optical coherence tomography (SS-OCT). Methods Forty class V cavities (2.5-mm surface diameter, 2.0-mm maximum depth) were prepared on cervical areas of 20 human molars. The specimens were either treated with one-step adhesive (Clearfil Tri-S Bond ND Quick; TS) or two-step adhesive (Clearfil SE Bond ...
      Read Full Article
    17. 1-15 of 79 1 2 3 4 5 6 »
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. About Yasunori Sumi

    Yasunori Sumi, DDS, is the Director at the Division of Oral and Dental Surgery, Department of Advanced Medicine, National Hospital for Geriatric Medicine, National Center for Geriatrics and Gerontology, Japan.