1. Xiaofei Wang

    0 Comments Leave a Comment

    1-3 of 3
    1. Mentioned In 3 Articles

    2. A Deep Learning Approach to Denoise Optical Coherence Tomography Images of the Optic Nerve Head

      A Deep Learning Approach to Denoise Optical Coherence Tomography Images of the Optic Nerve Head
      Optical coherence tomography (OCT) has become an established clinical routine for the in vivo imaging of the optic nerve head (ONH) tissues, that is crucial in the diagnosis and management of various ocular and neuro-ocular pathologies. However, the presence of speckle noise affects the quality of OCT images and its interpretation. Although recent frame-averaging techniques have shown to enhance OCT image quality, they require longer scanning durations, resulting in patient ...
      Read Full Article
    3. Feature Of The Week 05/28/2017: In Vivo 3-Dimensional Strain Mapping Confirms Large Optic Nerve Head Deformations Following Horizontal Eye Movements

      Feature Of The Week 05/28/2017: In Vivo 3-Dimensional Strain Mapping Confirms Large Optic Nerve Head Deformations Following Horizontal Eye Movements
      ...ed by eye movements and axonal loss in optic neuropathies. For more information see recent Article . Courtesy Xiaofei Wang and Michal J. A. Girard from National University of Singapore . Glaucoma is characterized by an i...
      Read Full Article
    4. In Vivo 3-Dimensional Strain Mapping Confirms Large Optic Nerve Head Deformations Following Horizontal Eye Movements

      In Vivo 3-Dimensional Strain Mapping Confirms Large Optic Nerve Head Deformations Following Horizontal Eye Movements
      Purpose : To measure lamina cribrosa (LC) strains (deformations) following abduction and adduction in healthy subjects and to compare them with those resulting from a relatively high acute intraocular pressure (IOP) elevation. Methods : A total of 16 eyes from 8 healthy subjects were included. Among the 16 eyes, 11 had peripapillary atrophy (PPA). For each subject, both optic nerve heads (ONHs) were imaged using optical coherence tomography (OCT) at baseline (twice ...
      Read Full Article
    5. 1-3 of 3
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. About Xiaofei Wang

    Xiaofei Wang

    Xiaofei Wang is at the Ophthalmic Engineering & Innovation Laboratory, Department of Biomedical Engineering, Faculty of Engineering, National University of Singapore, Singapore.