1. Walter Desmet

    0 Comments Leave a Comment

    1-15 of 31 1 2 »
    1. Mentioned In 31 Articles

    2. 5-Year clinical follow-up of the COBRA (complex coronary bifurcation lesions: Randomized comparison of a strategy using a dedicated self-expanding biolimus A9-eluting stent vs. a culotte strategy using everolimus-eluting stents) study

      5-Year clinical follow-up of the COBRA (complex coronary bifurcation lesions: Randomized comparison of a strategy using a dedicated self-expanding biolimus A9-eluting stent vs. a culotte strategy using everolimus-eluting stents) study
      Objectives We evaluated healing responses with optical coherence tomography, and long-term clinical outcomes after treatment with a dedicated stent versus a conventional culotte technique. Background Dedicated bifurcation stents have been proposed as an alternative treatment for coronary bifurcation lesions. The long-term performance of dedicated stents versus conventional dual-stent techniques for the treatment of complex coronary bifurcation lesions is unknown. Methods Forty patients with true coronary bifurcation lesions were randomized to ...
      Read Full Article
    3. EuOptical coherence tomography findings: insights from the “randomised multicentre trial investigating angiographic outcomes of hybrid sirolimus-eluting stents with biodegradable polymer compared with everolimus-eluting stents with durable polymer in chro

      EuOptical coherence tomography findings: insights from the “randomised multicentre trial investigating angiographic outcomes of hybrid sirolimus-eluting stents with biodegradable polymer compared with everolimus-eluting stents with durable polymer in chro
      Aims: The PRISON IV trial investigated the next-generation sirolimus-eluting stent (SES) with ultra-thin struts and biodegradable polymer against the second-generation everolimus-eluting stent (EES) with thin struts and durable polymer in patients with successfully recanalised chronic total occlusions (CTO). In this study, we examined the secondary optical coherence tomography endpoints. Methods and results: The main PRISON IV trial randomised 330 patients to either SES or EES. At nine months, 281 (85 ...
      Read Full Article
    4. Optical Coherence Tomography Findings in Patients with Coronary Stent Thrombosis: A Report of the PREvention of Late Stent Thrombosis by an Interdisciplinary Global European Effort (PRESTIGE) Consortium

      Optical Coherence Tomography Findings in Patients with Coronary Stent Thrombosis: A Report of the PREvention of Late Stent Thrombosis by an Interdisciplinary Global European Effort (PRESTIGE) Consortium
      Background Stent thrombosis (ST) is a serious complication following coronary stenting. Intravascular optical coherence tomography (OCT) may provide insights into mechanistic processes leading to ST. We performed a prospective, multicenter study to evaluate OCT findings in patients with ST. Methods Consecutive patients presenting with ST were prospectively enrolled in a registry using a centralized telephone registration system. After angiographic confirmation of ST, OCT imaging of the culprit vessel was performed ...
      Read Full Article
    5. Optical coherence tomography findings: insights from the “randomised multicentre trial investigating angiographic outcomes of hybrid sirolimus-eluting stents with biodegradable polymer compared with everolimus-eluting stents with durable polymer in chroni

      Optical coherence tomography findings: insights from the “randomised multicentre trial investigating angiographic outcomes of hybrid sirolimus-eluting stents with biodegradable polymer compared with everolimus-eluting stents with durable polymer in chroni
      Aims: The PRISON IV trial investigated the next-generation sirolimus-eluting stent (SES) with ultra-thin struts and biodegradable polymer against the second-generation everolimus-eluting stent (EES) with thin struts and durable polymer in patients with successfully recanalised chronic total occlusions (CTO). In this study, we examined the secondary optical coherence tomography endpoints. Methods and results: The main PRISON IV trial randomised 330 patients to either SES or EES. At nine months, 281 (85 ...
      Read Full Article
    6. Optical coherence tomography findings: insights from the “randomised multicentre trial investigating angiographic outcomes of hybrid sirolimus-eluting stents with biodegradable polymer compared with everolimus-eluting stents with durable polymer in chroni

      Optical coherence tomography findings: insights from the “randomised multicentre trial investigating angiographic outcomes of hybrid sirolimus-eluting stents with biodegradable polymer compared with everolimus-eluting stents with durable polymer in chroni
      Aims: The PRISON IV trial investigated the next-generation sirolimus-eluting stent (SES) with ultra-thin struts and biodegradable polymer against the second-generation everolimus-eluting stent (EES) with thin struts and durable polymer in patients with successfully recanalised chronic total occlusions (CTO). In this study, we examined the secondary optical coherence tomography endpoints. Methods and results: The main PRISON IV trial randomised 330 patients to either SES or EES. At nine months, 281 (85 ...
      Read Full Article
    7. Complex bifurcation lesions: Randomized comparison of a fully bioresorbable modified t stenting strategy versus bifurcation reconstruction with a dedicated self-expanding stent in combination with bioresorbable scaffolds, an OCT study: Rationale and desig

      Complex bifurcation lesions: Randomized comparison of a fully bioresorbable modified t stenting strategy versus bifurcation reconstruction with a dedicated self-expanding stent in combination with bioresorbable scaffolds, an OCT study: Rationale and desig
      Objective There is an ongoing controversy regarding the efficacy and safety of different percutaneous stenting techniques for coronary bifurcation lesions needing 1 stent. The promise of safe vessel restoration with bioresorbable scaffolds (BRS) may not be transferable to complex double BRS bifurcation techniques, and permanent metallic scaffolding of the bifurcation core may be needed. We identified modified-T stenting as the most promising fully bioresorbable 2-stent strategy in a preclinical setting ...
      Read Full Article
    8. COmplex coronary Bifurcation lesions: RAndomized comparison of a strategy using a dedicated self-expanding biolimus-eluting stent versus a culotte strategy using everolimus-eluting stents: primary results of the COBRA trial

      COmplex coronary Bifurcation lesions: RAndomized comparison of a strategy using a dedicated self-expanding biolimus-eluting stent versus a culotte strategy using everolimus-eluting stents: primary results of the COBRA trial
      Aims: We aimed to compare healing responses with optical coherence tomography, and clinical and angiographic outcome after treatment of coronary bifurcation lesions with a dedicated stent versus aconventional culotte technique. Methods and results: Forty patients with true and complex coronary bifurcation lesions were randomly assigned to treatment with the Axxess bifurcation stent in the proximal main vessel (MV) and additional BioMatrix stents in the branches (Biosensors Europe SA, Morges, Switzerland ...
      Read Full Article
    9. STACCATO (Assessment of Stent sTrut Apposition and Coverage in Coronary ArTeries with Optical coherence tomography in patients with STEMI, NSTEMI and stable/unstable angina undergoing everolimus vs. biolimus A9-eluting stent implantation): a randomised co

      STACCATO (Assessment of Stent sTrut Apposition and Coverage in Coronary ArTeries with Optical coherence tomography in patients with STEMI, NSTEMI and stable/unstable angina undergoing everolimus vs. biolimus A9-eluting stent implantation): a randomised co
      Aims: To compare tissue coverage in coronary lesions stented with durable fluoropolymer-coated everolimus-eluting stents (EES) vs. biodegradable polymer-coated biolimus A9-eluting stents (BES). Methods and results: Sixty-four patients (64 lesions) with de novo coronary artery lesions were randomised to percutaneous treatment with XIENCE EES (Abbott Vascular, Santa Clara, CA, USA) vs. BioMatrix BES (Biosensors, Morges, Switzerland). The primary endpoint was the percentage of uncovered struts, as assessed with OCT, at nine ...
      Read Full Article
    10. Optical coherence tomography study of healing characteristics of paclitaxel-eluting balloons vs. everolimus-eluting stents for in-stent restenosis: the SEDUCE (Safety and Efficacy of a Drug elUting balloon in Coronary artery rEstenosis) randomised clinica

      Optical coherence tomography study of healing characteristics of paclitaxel-eluting balloons vs. everolimus-eluting stents for in-stent restenosis: the SEDUCE (Safety and Efficacy of a Drug elUting balloon in Coronary artery rEstenosis) randomised clinica
      Aims: Little is known about the respective healing responses and clinical efficacy and safety of drug-eluting balloons (DEB) and the second generation of drug-eluting stents (DES) when used to treat in-stent restenosis (ISR). In this study, we set out to compare prospectively the healing characteristics, as assessed by optical coherence tomography (OCT), of DEB versus DES after treatment of ISR in bare metal stents (BMS). Methods and results: Fifty patients ...
      Read Full Article
    11. Automated detection and quantification of clusters of malapposed and uncovered intracoronary stent struts assessed with optical coherence tomography

      Automated detection and quantification of clusters of malapposed and uncovered intracoronary stent struts assessed with optical coherence tomography
      To date, accurate quantification and localization of malapposed and uncovered struts needs manual and time consuming analysis of large datasets. To develop an algorithm for automated detection and quantification of clusters of malapposed and uncovered struts in optical coherence tomography (OCT) pullbacks, including comprehensive information about their three-dimensional spatial distribution. 64 lesions in 64 patients treated with drug-eluting stent underwent assessment with OCT immediately after implantation and at 9-month follow-up ...
      Read Full Article
    12. Healing course of acute vessel wall injury after drug-eluting stent implantation assessed by optical coherence tomography

      Healing course of acute vessel wall injury after drug-eluting stent implantation assessed by optical coherence tomography
      BACKGROUND: Vessel wall injury after drug-eluting stent (DES) implantation can be characterized in detail by optical coherence tomography (OCT). Little is known about the healing course of these phenomena. METHODS AND RESULTS: In 62 lesions (62 patients), the incidence of acute vessel trauma was assessed in the stented region and the edge segments immediately after DES implantation. The healing course of these injuries was assessed at 9-month OCT follow-up using ...
      Read Full Article
    13. Automatic assessment of stent neointimal coverage by intravascular optical coherence tomography

      Automatic assessment of stent neointimal coverage by intravascular optical coherence tomography
      Aims This study aimed to validate automatic intravascular optical coherence tomography (IVOCT) analysis for the evaluation of neointimal coverage in response to stent implantation. Methods and results Fourteen stented segments in common iliac arteries, acquired from a total of seven adult male New Zealand White rabbits, were interrogated in vivo by IVOCT. Durable polymer everolimus-eluting stents (EES; Xience V, Abbott Vascular, Santa Clara, CA, USA) were used exclusively. Comparison with ...
      Read Full Article
    14. Automated tissue characterization of in vivo atherosclerotic plaques by intravascular optical coherence tomography images

      Automated tissue characterization of in vivo atherosclerotic plaques by intravascular optical coherence tomography images
      Intravascular optical coherence tomography (IVOCT) is rapidly becoming the method of choice for the in vivo investigation of coronary artery disease. While IVOCT visualizes atherosclerotic plaques with a resolution 20m, image analysis in terms of tissue composition is currently performed by a time-consuming manual procedure based on the qualitative interpretation of image features. We illustrate an algorithm for the automated and systematic characterization of IVOCT atherosclerotic tissue. The proposed method ...
      Read Full Article
    15. Provisional side branch stenting: presentation of an automated method allowing online 3D OCT guidance

      Provisional side branch stenting: presentation of an automated method allowing online 3D OCT guidance
      A 58-year-old man with unstable angina underwent percutaneous coronary intervention for a severe stenosis of the mid-left anterior descending artery (LAD), at a bifurcation point with a large diameter diagonal side branch (SB). After predilation with an Emerge 3.0 12 mm balloon (Boston Scientific, MA, USA), a 3.0 32 mm Promus Element (Boston Scientific) everolimus-eluting stent was implanted in the LAD. Subsequently, proximal post-dilation with a non-compliant (NC ...
      Read Full Article
    16. 1-15 of 31 1 2 »
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. About Walter Desmet

    Walter Desmet

    Walter Desmet, MD, is in the Department of Cardiology at Gasthuisberg University Hospital in Leuven, Belgium.