1. Zeiss Visante OCT

    0 Comments Leave a Comment

    1-15 of 209 1 2 3 4 ... 12 13 14 »
    1. Mentioned In 209 Articles

    2. Imaging of filtering blebs after implantation of the Ex-PRESS shunt with the use of the Visante optical coherence tomography

      Imaging of filtering blebs after implantation of the Ex-PRESS shunt with the use of the Visante optical coherence tomography
      ...edure was augmented with the use of mitomycin C subconjunctivally. The filtering blebs were analyzed with the Visante AS-OCT with the scans taken along the axis of the implantation of the glaucoma device. RESULTS: All fi...
      Read Full Article
    3. Staging of development in Terrien’s degeneration based on corneal curvatures detected by optical coherence tomography

      Staging of development in Terrien’s degeneration based on corneal curvatures detected by optical coherence tomography
      ... with Terriens degeneration were examined with slit lamp biomicroscopy, Orbscan II corneal tomography and the Visante OCT system, and were staged according to Svegess classification. Results The ratio of female to male p...
      Read Full Article
    4. Comparative Study of Anterior Eye Segment Measurements with Spectral Swept-Source and Time-Domain Optical Coherence Tomography in Eyes with Corneal Dystrophies

      Comparative Study of Anterior Eye Segment Measurements with Spectral Swept-Source and Time-Domain Optical Coherence Tomography in Eyes with Corneal Dystrophies
      Purpose. To compare anterior eye segment measurements and morphology obtained with two optical coherence tomography systems (TD OCT, SS OCT) in eyes with corneal dystrophies (CDs). Methods . Fifty healthy volunteers (50 eyes) and 54 patients (96 eyes) diagnosed with CD (epithelial basement membrane dystrophy, EBMD = 12 eyes; Thiel-Behnke CD = 6 eyes; lattice CD TGFBI type = 15 eyes; granular CD type 1 = 7 eyes, granular CD type 2 = 2 eyes; macular ...
      Read Full Article
    5. Anterior and Posterior Ocular Biometry in Healthy Chinese Subjects: Data Based on AS-OCT and SS-OCT

      Anterior and Posterior Ocular Biometry in Healthy Chinese Subjects: Data Based on AS-OCT and SS-OCT
      Background To measure the anterior and posterior ocular biometric characteristics concurrently and to determine the relationship between the iris and choroid in healthy Chinese subjects. Methods A total of 148 subjects (270 eyes) were enrolled in this cross-section study. The anterior and posterior ocular biometric characteristics were measured simultaneously by anterior segment optical coherence tomography (AS-OCT) and swept-source optical coherence tomography (SS-OCT). Results Compared with male eyes, female eyes had ...
      Read Full Article
    6. Comparison of central corneal thickness measurements using optical low-coherence reflectometry, Fourier domain optical coherence tomography, and Scheimpflug camera

      Comparison of central corneal thickness measurements using optical low-coherence reflectometry, Fourier domain optical coherence tomography, and Scheimpflug camera
      ...S. Comparative study of central corneal thickness measurement with slit-lamp optical coherence tomography and visante optical coherence tomography. Ophthalmology. 2008;115:796-801. [ Links ] 26.  Lattimore MR Jr, Kaupp ...
      Read Full Article
    7. Comparative analysis of corneal measurements obtained from a Scheimpflug camera and an integrated Placido-optical coherence tomography device in normal and keratoconic eyes

      Comparative analysis of corneal measurements obtained from a Scheimpflug camera and an integrated Placido-optical coherence tomography device in normal and keratoconic eyes
      ...The Pentacam measured significantly greater corneal curvature, thickness and elevation values compared to the Visante OMNI in normal and keratoconic eyes. The devices agree moderately for anterior corneal elevations in n...
      Read Full Article
    8. Visante Anterior Segment Optical Coherence Tomography Analysis of Morphologic Changes After Deep Sclerectomy With Intraoperative Mitomycin-C and No Implant Use

      Visante Anterior Segment Optical Coherence Tomography Analysis of Morphologic Changes After Deep Sclerectomy With Intraoperative Mitomycin-C and No Implant Use
      ...olume Publish Ahead of Print - Issue - ppg doi: 10.1097/IJG.0000000000000179 Letter to the Editor: PDF Only Visante Anterior Segment Optical Coherence Tomography Analysis of Morphologic Changes After Deep Sclerectomy W...
      Read Full Article
    9. Dynamic dark-light changes in anterior chamber and iris parameters in angle closure patients with novel automatic algorithm using anterior segment optical coherence tomography (AS-OCT)

      Dynamic dark-light changes in anterior chamber and iris parameters in angle closure patients with novel automatic algorithm using anterior segment optical coherence tomography (AS-OCT)
      ...mal angles) on gonioscopic grading were recruited. We acquired images in both dark and light conditions using Visante OCT. Custom software analyzed the images using the iris rim as the landmark instead of the sclera spur...
      Read Full Article
    10. Evaluation of Pachymetric Measurements with Scheimpflug Photography-Based System and Optical Coherence Tomography Pachymetry at Different Stages of Keratoconus

      Evaluation of Pachymetric Measurements with Scheimpflug Photography-Based System and Optical Coherence Tomography Pachymetry at Different Stages of Keratoconus
      ...is study was to compare the central and peripheral pachymetric measurements determined with Sirius system and Visante OCT and evaluate the agreement between them at different stages of keratoconus. Measurements were not ...
      Read Full Article
    11. 1-15 of 209 1 2 3 4 ... 12 13 14 »
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. About Zeiss Visante OCT

    Zeiss Visante OCT

    Visante OCT.  Carl Zeiss Meditec's Ophthalmic OCT product Optimized for Anterior Segment Imaging and Biometry.