1. Victor X. D. Yang

    0 Comments Leave a Comment

    1-15 of 91 1 2 3 4 5 6 »
    1. Mentioned In 91 Articles

    2. Beam-shifting technique for speckle reduction and flow rate measurement in optical coherence tomography

      Beam-shifting technique for speckle reduction and flow rate measurement in optical coherence tomography
      In this Letter, we propose a beam-shifting optical coherence tomography scheme for speckle reduction and blood flow rate calculation, where variations of the speckle pattern and Doppler angle were generated by parallel shifting of the sample beam incident on the objective lens. The resultant optical coherent tomography images could then be averaged for speckle noise reduction and simultaneously analyzed for flow rate measurement. The performance of the proposed technique was ...
      Read Full Article
    3. Buffer-averaging super-continuum source based spectral domain optical coherence tomography for high speed imaging

      Buffer-averaging super-continuum source based spectral domain optical coherence tomography for high speed imaging
      In super-continuum (SC) source based spectral domain optical coherence tomography (SC-SDOCT), the stability of the power spectral density (PSD) has a significant impact on OCT system sensitivity and image signal to noise ratio (SNR). High speed imaging decreases the camera's exposure time, thus each A-scan contained fewer laser pulse excited SC wideband emissions, resulting in a decrease of SNR. In this manuscript, we present a buffer-averaging SC-SDOCT (BASC-SDOCT) to ...
      Read Full Article
    4. Carotid artery stenting with optical coherence tomography

      Carotid artery stenting with optical coherence tomography
      A 61-year-old man underwent a left cervical internal carotid artery stenting following a recent ischemic stroke. Postoperative angiography was satisfactory and did not reveal any in-stent filling defect ( figure 1A ). Optical coherence tomography (OCT) probe was used to visualize the endoluminal area following stenting. OCT confirmed optimum placement of the stent and reveled a small plaque protrusion from the stent struts following deployment ( figure 1B ).
      Read Full Article
    5. Gabor optical coherence tomographic angiography (GOCTA) (Part I): human retinal imaging in vivo

      Gabor optical coherence tomographic angiography (GOCTA) (Part I): human retinal imaging in vivo
      Recently, parallel high A-line speed and wide field imaging for optical coherence tomography angiography (OCTA) has become more prevalent, resulting in a dramatic increase of data quantity which poses a challenge for real time imaging even for GPU in data processing. In this manuscript, we propose a new OCTA processing technique, Gabor optical coherence tomographic angiography (GOCTA), for label-free human retinal angiography imaging. In spectral domain optical coherence tomography (SDOCT ...
      Read Full Article
    6. High speed, wide velocity dynamic range Doppler optical coherence tomography (Part V): Optimal utilization of multi-beam scanning for Doppler and speckle variance microvascular imaging

      High speed, wide velocity dynamic range Doppler optical coherence tomography (Part V): Optimal utilization of multi-beam scanning for Doppler and speckle variance microvascular imaging
      In this paper, a multi-beam scanning technique is proposed to optimize the microvascular images of human skin obtained with Doppler effect based methods and speckle variance processing. Flow phantom experiments were performed to investigate the suitability for combining multi-beam data to achieve enhanced microvascular imaging. To our surprise, the highly variable spot sizes (ranging from 13 to 77 m) encountered in high numerical aperture multi-beam OCT system imaging the same ...
      Read Full Article
    7. Intraoperative optical coherence tomography of the cerebral cortex using a 7 degree-of freedom robotic arm

      Intraoperative optical coherence tomography of the cerebral cortex using a 7 degree-of freedom robotic arm
      Optical Coherence Tomography (OCT) provides a high-resolution imaging technique with limited depth penetration. The current use of OCT is limited to relatively small areas of tissue for anatomical structure diagnosis or minimally invasive guided surgery. In this study, we propose to image a large area of the surface of the cerebral cortex. This experiment aims to evaluate the potential difficulties encountered when applying OCT imaging to large and irregular surface ...
      Read Full Article
    8. Graphics processor unit acceleration enables realtime endovascular Doppler optical coherence tomography imaging

      Graphics processor unit acceleration enables realtime endovascular Doppler optical coherence tomography imaging
      Endovascular Optical Coherence Tomography (OCT) has previously been used in both bench-top and clinical environments to produce vascular images, and can be helpful in characterizing, among other pathologies, plaque build-up and impedances to normal blood ow. The raw data produced can also be processed to yield high- resolution blood velocity information, but this computation is expensive and has previously only been available a posteriori using post-processing software. Real-time Doppler OCT ...
      Read Full Article
    9. Multi-beam optical coherence tomography for microvascular imaging of human skin in vivo

      Multi-beam optical coherence tomography for microvascular imaging of human skin in vivo
      In this paper, a multi-beam optical coherence tomography (OCT) was used to reconstruct the microvascular image of human skin in vivo with phase resolved Doppler OCT (PRDOCT), phase resolved Doppler variance (PRDV) and speckle variance OCT (svOCT), in which the blood flow image was calculated by averaging the four blood flow images obtained by the four beams. In PRDOCT method, it is difficult to detect the blood flow perpendicular to ...
      Read Full Article
    10. Differential standard deviation of log-scale intensity based optical coherence tomography angiography

      Differential standard deviation of log-scale intensity based optical coherence tomography angiography
      In this paper, a differential standard deviation of log-scale intensity (DSDLI) based optical coherence tomography angiography (OCTA) is presented for calculating microvascular images of human skin. The DSDLI algorithm calculates the variance in difference images of two consecutive log-scale intensity based structural images from the same position along depth direction to contrast blood flow. The en face microvascular images were then generated by calculating the standard deviation of the differential ...
      Read Full Article
    11. Methods and systems for coherent imaging and feedback control for modification of materials

      Methods and systems for coherent imaging and feedback control for modification of materials
      Methods and systems are provided for using optical interferometry in the context of material modification processes such as surgical laser or welding applications. An imaging optical source that produces imaging light. A feedback controller controls at least one processing parameter of the material modification process based on an interferometry output generated using the imaging light. A method of processing interferograms is provided based on homodyne filtering. A method of generating ...
      Read Full Article
    12. Speckle And Motion Based Vascular Image Analysis for Optical Coherence Tomography (Thesis)

      Speckle And Motion Based Vascular Image Analysis for Optical Coherence Tomography (Thesis)
      Optical Coherence Tomography (OCT) is an emerging optical imaging modality that is capable of imaging biological tissues with micron resolution and millimeter penetration depth. In clinical diagnostic imaging and pathology, OCT has helped fill a gap in terms of both resolution and imaging depth, in between traditional fluoroescence based microscopes and non-invasive organ level imaging. In this domain, OCT can be used both as an ex vivo pathological examination tool ...
      Read Full Article
    13. Measuring the optical characteristics of medulloblastoma with optical coherence tomography

      Measuring the optical characteristics of medulloblastoma with optical coherence tomography
      Medulloblastoma is the most common malignant pediatric brain tumor. Standard treatment consists of surgical resection, followed by radiation and high-dose chemotherapy. Despite these efforts, recurrence is common, leading to reduced patient survival. Even with successful treatment, there are often severe long-term neurologic impacts on the developing nervous system. We present two quantitative techniques that use a high-resolution optical imaging modality: optical coherence tomography (OCT) to measure refractive index, and the ...
      Read Full Article
    14. 1-15 of 91 1 2 3 4 5 6 »
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. About Victor X. D. Yang

    Victor X. D. Yang

    Victor Yang, PhD, is an Assistant Professor in the Department of Electrical and Computer Engineering and the Department of Physics at Ryerson University in Canada. Research Focus: Optical coherence tomography, intra-operative fluorescence imaging, photodynamic therapy, micro-machined electro-mechanical probes/catheters.

  3. Quotes

    1. Young Ryerson researchers are working with the best in the field, and I think they can compete on the world stage in the near future.
      In An engineer and doctor, researcher Victor Yang develops medical technology to detect and treat disease
    2. These collaborations are out-of-the-box partnerships that lead to creative thinking and practical problem solving. They just reflect our university's history and traditional strength, in a new arena.
      In An engineer and doctor, researcher Victor Yang develops medical technology to detect and treat disease