1. Tsuyoshi Nishiguchi

    0 Comments Leave a Comment

    1-15 of 19 1 2 »
    1. Mentioned In 19 Articles

    2. Imaging assessment and accuracy in coronary artery autopsy: comparison of frequency-domain optical coherence tomography with intravascular ultrasound and histology

      Imaging assessment and accuracy in coronary artery autopsy: comparison of frequency-domain optical coherence tomography with intravascular ultrasound and histology
      ptical coherence tomography (OCT) is a coronary artery imaging technique with high resolution. Second-generation frequency-domain OCT (FD-OCT) technology allows safer and faster clinical application compared with first-generation time-domain OCT (TD-OCT). Only limited validation studies compare FD-OCT with other modes of analysis: histology, which is the current gold standard, and intravascular ultrasound (IVUS). This study therefore aims to demonstrate the accuracy of FD-OCT images compared with IVUS and histology. FD-OCT and ...
      Read Full Article
    3. Role of Optical Coherence Tomography in the Diagnosis of Spontaneous Coronary Artery Dissection

      Role of Optical Coherence Tomography in the Diagnosis of Spontaneous Coronary Artery Dissection
      Spontaneous coronary artery dissection (SCAD) is an infrequent and often missed diagnosis among patients with acute coronary syndrome (ACS), especially young healthy females. Unfortunately, SCAD can result in significant morbidity, such as ischemia and infarction. Currently, there has been a surge in the diagnosis of SCAD due to the widespread use of new intracoronary imaging modalities, especially optical coherence tomography (OCT).However, no specific guidelines exist concerning appropriate treatment for ...
      Read Full Article
    4. In vivo optical coherence tomography imaging and histopathology of healed coronary plaques

      In vivo optical coherence tomography imaging and histopathology of healed coronary plaques
      Background and aims The aims of this study were to assess agreement between optical coherence tomography (OCT) and histopathology for healed coronary plaques (HCPs) in human coronary arteries ex vivo , and to evaluate the prevalence and characteristics of HCPs in vivo . Methods Ex vivo OCT images were co-registered with histopathology in 144 cross-sections with 50% stenosis. Of these, 30 randomly selected pairs were employed to define morphological features of OCT ...
      Read Full Article
    5. Effect of Early Pitavastatin Therapy on Coronary Fibrous-Cap Thickness Assessed by Optical Coherence Tomography in Patients With Acute Coronary Syndrome : The ESCORT Study

      Effect of Early Pitavastatin Therapy on Coronary Fibrous-Cap Thickness Assessed by Optical Coherence Tomography in Patients With Acute Coronary Syndrome : The ESCORT Study
      ...eRence Tomography (ESCORT): UMIN000002678 ). JACC: Cardiovascular Imaging, Volume null, Issue null, Page null Tsuyoshi Nishiguchi, Takashi Kubo, Takashi Tanimoto, Yasushi Ino, Yoshiki Matsuo, Takashi Yamano, Kosei Terada...
      Read Full Article
    6. Prognosis of spontaneous coronary artery dissection treated by percutaneous coronary intervention with optical coherence tomography

      Prognosis of spontaneous coronary artery dissection treated by percutaneous coronary intervention with optical coherence tomography
      Background Although about half of patients with spontaneous coronary artery dissection (SCAD) face ongoing necrosis, conservative therapy is recommended due to a high complication rate in angiography-guided percutaneous coronary intervention (PCI). The aim of this study was to investigate clinical outcomes of SCAD treated by optical coherence tomography (OCT)-guided PCI. Methods This study consisted of consecutive 306 patients with acute coronary syndrome (ACS) who underwent OCT-guided PCI. Based on ...
      Read Full Article
    7. Optical Coherence Tomography Predictors for Edge Restenosis After Everolimus-Eluting Stent Implantation

      Optical Coherence Tomography Predictors for Edge Restenosis After Everolimus-Eluting Stent Implantation
      Background Stent edge restenosis (SER) remains a potential limitation of drug-eluting stents. The aim of this study was to determine optical coherence tomography (OCT) predictors for angiographic late SER after everolimus-eluting stent implantation. Methods and Results We retrospectively analyzed 319 patients who underwent OCT immediately after everolimus-eluting stent implantation and scheduled 9- to 12-month follow-up angiography. The binary angiographic SER rate was 10% (32/319) in the patients, 8.4 ...
      Read Full Article
    8. Reduction of in-stent thrombus immediately after percutaneous coronary intervention by pretreatment with prasugrel compared with clopidogrel: An optical coherence tomography study

      Reduction of in-stent thrombus immediately after percutaneous coronary intervention by pretreatment with prasugrel compared with clopidogrel: An optical coherence tomography study
      Background Prasugrel is a new-generation thienopyridine antiplatelet agent that provides more consistent and prompt platelet inhibition than clopidogrel. The aim of this study was to compare in-stent thrombus inhibition effect of pretreatment with prasugrel and clopidogrel by using optical coherence tomography (OCT) immediately after percutaneous coronary intervention (PCI) for acute coronary syndrome (ACS). Methods We performed OCT immediately after PCI in 108 ACS patients pretreated with either prasugrel ( n = 51 ...
      Read Full Article
    9. Optical coherence tomography assessment of efficacy of thrombus aspiration in patients undergoing a primary percutaneous coronary intervention for acute ST-elevation myocardial infarction

      Optical coherence tomography assessment of efficacy of thrombus aspiration in patients undergoing a primary percutaneous coronary intervention for acute ST-elevation myocardial infarction
      Objective: We used optical coherence tomography (OCT) to assess the impact of thrombus aspiration before angioplasty on poststenting tissue protrusions in patients undergoing a primary percutaneous coronary intervention (PCI) for ST-segment elevation myocardial infarction (STEMI). Methods and results: A total of 188 patients with STEMI who underwent thrombus-aspiration PCI ( n =113) or standard PCI ( n =75) were examined in this study. OCT was performed immediately after primary PCI to assess ...
      Read Full Article
    10. Optical coherence tomography assessment of efficacy of thrombus aspiration in patients undergoing a primary percutaneous coronary intervention for acute ST-elevation myocardial infarction

      Optical coherence tomography assessment of efficacy of thrombus aspiration in patients undergoing a primary percutaneous coronary intervention for acute ST-elevation myocardial infarction
      Objective: We used optical coherence tomography (OCT) to assess the impact of thrombus aspiration before angioplasty on poststenting tissue protrusions in patients undergoing a primary percutaneous coronary intervention (PCI) for ST-segment elevation myocardial infarction (STEMI). Methods and results: A total of 188 patients with STEMI who underwent thrombus-aspiration PCI ( n =113) or standard PCI ( n =75) were examined in this study. OCT was performed immediately after primary PCI to assess ...
      Read Full Article
    11. Optimal threshold of postintervention minimum stent area to predict in-stent restenosis in small coronary arteries: An optical coherence tomography analysis

      Optimal threshold of postintervention minimum stent area to predict in-stent restenosis in small coronary arteries: An optical coherence tomography analysis
      Objectives The aim of this study was to determine the best threshold of postintervention minimum stent area (MSA) assessed by optical coherence tomography (OCT) to predict long-term in-stent restenosis (ISR) for 2.5 mm-diameter everolimus-eluting stents (EES). Background Percutaneous coronary intervention (PCI) for small coronary arteries remains challenging. Stent underexpansion is a strong predictor of late ISR. Methods We performed a retrospective analysis of 69 lesions in 69 patients undergoing ...
      Read Full Article
    12. Optical coherence tomography assessment of efficacy of thrombus aspiration in patients undergoing a primary percutaneous coronary intervention for acute ST-elevation myocardial infarction

      Optical coherence tomography assessment of efficacy of thrombus aspiration in patients undergoing a primary percutaneous coronary intervention for acute ST-elevation myocardial infarction
      Objective: We used optical coherence tomography (OCT) to assess the impact of thrombus aspiration before angioplasty on poststenting tissue protrusions in patients undergoing a primary percutaneous coronary intervention (PCI) for ST-segment elevation myocardial infarction (STEMI). Methods and results: A total of 188 patients with STEMI who underwent thrombus-aspiration PCI (n=113) or standard PCI (n=75) were examined in this study. OCT was performed immediately after primary PCI to assess ...
      Read Full Article
    13. Vasa Vasorum Restructuring in Human Atherosclerotic Plaque Vulnerability

      Vasa Vasorum Restructuring in Human Atherosclerotic Plaque Vulnerability
      Background Previous studies have suggested that vasa vasorum (VV) is associated with plaque progression and vulnerability. Objectives The aim of this study was to investigate the relationship between coronary neovascularization structures and plaque characteristics. Methods We included 53 patients who underwent optical coherence tomography to observe the proximal left anterior descending coronary artery. Patients were classified into 5 groups according to lesion characteristics: normal; fibrous plaque (FP); fibroatheroma (FA); plaque ...
      Read Full Article
    14. Feasibility of Optical Coronary Tomography in Quantitative Measurement of Coronary Arteries With Lipid-Rich Plaque

      Feasibility of Optical Coronary Tomography in Quantitative Measurement of Coronary Arteries With Lipid-Rich Plaque
      Background: The aim of the present study was to evaluate the feasibility of optical coherence tomography (OCT) for measurement of vessel area in coronary arteries with lipid-rich plaque as compared with intravascular ultrasound (IVUS). Methods and Results: We investigated 80 coronary artery segments with lipid-rich plaque on OCT and non-attenuated plaque on IVUS. According to the lipid arc on OCT, the plaques were classified into 4 groups: group 1, lipid ...
      Read Full Article
    15. 1-15 of 19 1 2 »
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. About Tsuyoshi Nishiguchi

    Tsuyoshi Nishiguchi is with the Department of Cardiovascular Medicine, Wakayama Medical University, Wakayama, Japan.