1. Toshiro Shinke

    0 Comments Leave a Comment

    1-15 of 70 1 2 3 4 5 »
    1. Mentioned In 70 Articles

    2. Association of Cholesterol Uptake Capacity, a Novel Indicator for HDL Functionality, and Coronary Plaque Properties: An Optical Coherence Tomography-based Observational Study

      Association of Cholesterol Uptake Capacity, a Novel Indicator for HDL Functionality, and Coronary Plaque Properties: An Optical Coherence Tomography-based Observational Study
      Background Cholesterol efflux from atherosclerotic lesion is a key function of high-density lipoprotein (HDL). Recently, we established a simple, high-throughput, cell-free assay to evaluate the capacity of HDL to accept additional cholesterol, which is herein referred to as cholesterol uptake capacity (CUC). Objective To clarify the cross-sectional relationship between CUC and coronary plaque properties. Methods We enrolled 135 patients to measure CUC and assess the morphological features of angiographic stenosis ...
      Read Full Article
    3. Cut-off value of strut-vessel distance for the resolution of acute incomplete stent apposition in the early phase using serial optical coherence tomography after cobalt-chromium everolimus-eluting stent implantation

      Cut-off value of strut-vessel distance for the resolution of acute incomplete stent apposition in the early phase using serial optical coherence tomography after cobalt-chromium everolimus-eluting stent implantation
      Objective The purpose of this study was to identify a cut-off value to predict the resolution of incomplete-stent-apposition (ISA) after cobalt-chromium everolimus-eluting stent (CoCr-EES) implantation at early follow-up. Background To date, appropriate stent apposition at the acute period using intracoronary imaging has been recommended because persistent ISA is considered to be a risk factor for stent thrombosis. We examined the indices for resolving acute ISA. In particular, we determined the ...
      Read Full Article
    4. Efficacy of optical frequency-domain imaging in detecting peripheral artery disease: a single-center open-label, single-arm study protocol

      Efficacy of optical frequency-domain imaging in detecting peripheral artery disease: a single-center open-label, single-arm study protocol
      Intravascular optical coherence tomography is a high-resolution intracoronary imaging modality, providing a microscopic image of intravascular features. However, it has lower penetration depth than intravascular ultrasound. Recently, a second-generation optical frequency-domain imaging (OFDI) technique has been developed to provide greater penetration depth and faster pullback speed. However, there is little evidence supporting the efficacy of OFDI in patients with peripheral artery disease (PAD) undergoing endovascular treatment (EVT). We aimed to ...
      Read Full Article
    5. Optical Technology Stepping Forward ― Utility of Intracoronary Optical Coherence Tomography ―

      Optical Technology Stepping Forward ― Utility of Intracoronary Optical Coherence Tomography ―
      I ntravascular optical coherence tomography (OCT) is a light-based imaging modality that enables detailed visualization of the intraluminal structures in coronary arteries. High-resolution (1020m) cross-sectional images are generated by measuring the echo time delay and intensity of light that is reflected or backscattered from the internal structures in tissues.1,2 OCT is clinically useful during percutaneous coronary intervention (PCI) to assess lesion severity, optimize stent implantation, and characterize atherosclerotic ...
      Read Full Article
      Mentions: Toshiro Shinke
    6. Expert consensus statement for quantitative measurement and morphological assessment of optical coherence tomography

      Expert consensus statement for quantitative measurement and morphological assessment of optical coherence tomography
      In this document, the methods for the quantitative measurement and morphological assessment of optical coherence tomography (OCT)/optical frequency domain imaging images (OFDI) are briefly summarized. The focus is on the clinical application of OCT/OFDI to guide percutaneous coronary interventions.
      Read Full Article
    7. Early and mid-term vascular responses to optical coherence tomography guided everolimus-eluting stent implantation in stable coronary artery disease

      Early and mid-term vascular responses to optical coherence tomography guided everolimus-eluting stent implantation in stable coronary artery disease
      Background Analysis of pooled clinical data has shown the safety of 3 months of dual antiplatelet therapy (DAPT) with everolimus-eluting cobaltchromium stents (Co-Cr EESs). This study evaluated early and mid-term vascular responses to Co-Cr EESs in patients with stable coronary artery disease (CAD). Methods The MECHANISM-Elective trial (NCT02014818) is a multicenter optical coherence tomography (OCT) registry. Enrolled patients were evaluated by OCT immediately after EES implantation (post), were prospectively allocated ...
      Read Full Article
    8. Favorable early vessel healing after everolimus-eluting stent implantation: 3-, 6-, and 12-month follow-up of optical coherence tomography

      Favorable early vessel healing after everolimus-eluting stent implantation: 3-, 6-, and 12-month follow-up of optical coherence tomography
      Background Although a prospective randomized control study revealed that 3-month dual anti-platelet therapy (DAPT) is safe and does not compromise the efficacy of everolimus-eluting stent (EES) in selected patients, detailed vessel healing at early phase after EES implantation has yet to be investigated in Japanese patients. Methods and results A total of 27 lesions in 19 patients treated with EES were serially evaluated by using optical coherence tomography (OCT) at ...
      Read Full Article
    9. Lumen Boundaries Extracted from Coronary Computed Tomography Angiography on Computed Fractional Flow Reserve (FFRCT): Validation with Optical Coherence Tomography

      Lumen Boundaries Extracted from Coronary Computed Tomography Angiography on Computed Fractional Flow Reserve (FFRCT): Validation with Optical Coherence Tomography
      Aims: To evaluate the accuracy of minimal lumen area (MLA) by coronary computed tomography angiography (cCTA) and its impact on fractional flow reserve (FFRCT). Methods and results: Fifty-seven patients (118 lesions, 72 vessels) who underwent cCTA and optical coherence tomography (OCT) were enrolled. OCT and cCTA were co-registered and MLAs were measured with both modalities. FFROCT was calculated using OCT-updated models with cCTA-based lumen geometry replaced by OCT-derived geometry. Lesions ...
      Read Full Article
    10. Comparison between Optical COherence tomography guidance and Angiography guidance in percutaneous coronary intervention (COCOA): Study protocol for a randomized controlled trial

      Comparison between Optical COherence tomography guidance and Angiography guidance in percutaneous coronary intervention (COCOA): Study protocol for a randomized controlled trial
      Background Optical coherence tomography (OCT) is increasingly used as an adjunct to coronary angiography for guiding percutaneous coronary intervention (PCI). The current consensus on PCI is that the large final stent area offers the best chance of a good late clinical outcome. Since OCT provides more accurate information about the coronary artery and implanted stents, OCT-guided stent implantation is expected to achieve greater stent expansion than angiography guidance alone. Therefore ...
      Read Full Article
    11. Impact of CD14++CD16+ monocytes on coronary plaque vulnerability assessed by optical coherence tomography in coronary artery disease patients with well-regulated lipid levels

      Impact of CD14++CD16+ monocytes on coronary plaque vulnerability assessed by optical coherence tomography in coronary artery disease patients with well-regulated lipid levels
      Background and aims This study examined the impact of CD14 ++ CD16 + monocytes on coronary plaque vulnerability, as assessed by optical coherence tomography (OCT), and investigated their association with daily glucose fluctuation. Although increased CD14 ++ CD16 + monocyte levels have been reported to increase cardiovascular events, their impact on coronary plaque vulnerability in coronary artery disease (CAD) patients with or without diabetes mellitus (DM) remains unclear. Methods This prospective observational study included ...
      Read Full Article
    12. Early vascular responses to everolimus-eluting cobalt–chromium stent in the culprit lesions of st-elevation myocardial infarction: results from a multicenter prospective optical coherence tomography study (MECHANISM-AMI 2-week follow-up study)

      Early vascular responses to everolimus-eluting cobalt–chromium stent in the culprit lesions of st-elevation myocardial infarction: results from a multicenter prospective optical coherence tomography study (MECHANISM-AMI 2-week follow-up study)
      The use of cobaltchromium everolimus-eluting stents (CoCr-EES) for ST-segment elevation myocardial infarction (STEMI) reduces the incidence of stent thrombosis compared with bare metal stents, and a substantial difference is apparent in the initial 2 weeks. However, vascular behavior during this early period remains unclear. This was a prospective study (MECHANISM-AMI-2W) to investigate early vascular responses in STEMI patients immediately after CoCr-EES implantation and at 2-week follow-up using frequency domain-optical coherence ...
      Read Full Article
    13. Data on two- and three-dimensional optical coherence tomography guidance for the treatment for the bifurcation lesion

      Data on two- and three-dimensional optical coherence tomography guidance for the treatment for the bifurcation lesion
      This article comprised the data related to the research article entitled Feasibility and usefulness of three-dimensional optical coherence tomography guidance for optimal side branch treatment in coronary bifurcation stenting (Nagoshi et al., In press) [1] . In this article we reports details about two patterns of guide wire (GW) recrossing position after crossover stenting in bifurcation lesion classified with three-dimensional optical coherence tomography (3D-OCT) (Okamura et al., 2014) [2] and follow-up ...
      Read Full Article
    14. Impact of Guidewire Recrossing Point into Stent Jailed Side Branch for Optimal Kissing Balloon Dilatation - Corelab 3D Optical Coherence Tomography Analysis

      Impact of Guidewire Recrossing Point into Stent Jailed Side Branch for Optimal Kissing Balloon Dilatation - Corelab 3D Optical Coherence Tomography Analysis
      AIMS: We investigated the influence of the guidewire recrossing point on the incidence of incomplete stent apposition (ISA) after kissing balloon dilatation (KBD), and clinical and angiographic outcome at 9 months in a prospective multicenter registry. METHODS AND RESULTS: One hundred five patients underwent single crossover stenting across the side branch (SB) and subsequent KBD. Jailing configuration of the SB orifice and the guidewire recrossing position were assessed by off-line ...
      Read Full Article
    15. Optical Frequency Domain Imaging Versus Intravascular Ultrasound in Percutaneous Coronary Intervention (OPINION Trial) : Results From the OPINION Imaging Study

      Optical Frequency Domain Imaging Versus Intravascular Ultrasound in Percutaneous Coronary Intervention (OPINION Trial) : Results From the OPINION Imaging Study
      Objectives We sought to clarify how intravascular ultrasound (IVUS) and optical coherence tomography affect percutaneous coronary intervention (PCI) with current-generation drug-eluting stents in a pre-specified substudy of the OPINION (OPtical frequency domain imaging versus INtravascular ultrasound in percutaneous coronary interventiON) trial, a multicenter, prospective, randomized, noninferiority trial comparing optical frequency domain imaging (OFDI)-guided PCI with IVUS-guided PCI. Background The impact of these 2 imaging modalities in guiding PCI remains ...
      Read Full Article
    16. Feasibility and usefulness of three-dimensional optical coherence tomography guidance for optimal side branch treatment in coronary bifurcation stenting

      Feasibility and usefulness of three-dimensional optical coherence tomography guidance for optimal side branch treatment in coronary bifurcation stenting
      Background For the treatment of coronary bifurcation lesions, optimal guidewire (GW) recrossing after main vessel stenting is important for good stent apposition at the side branch (SB) orifice in kissing balloon inflation (KBI). Methods We analyzed 150 bifurcation lesions treated with single stenting following KBI in the three-dimensional optical coherence tomography (3D-OCT) bifurcation registry study (201516) and a single center experience (201216). OCT examination was performed after GW recrossing to ...
      Read Full Article
    17. 1-15 of 70 1 2 3 4 5 »
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. About Toshiro Shinke

    Toshiro Shinke is an MD in cardiology at Department of Internal Medicine, Division of Cardiovascular and Respiratory Medicine, Kobe University Graduate School of Medicine, Japan.