1. Toshiro Shinke

    0 Comments Leave a Comment

    1-15 of 64 1 2 3 4 5 »
    1. Mentioned In 64 Articles

    2. Favorable early vessel healing after everolimus-eluting stent implantation: 3-, 6-, and 12-month follow-up of optical coherence tomography

      Favorable early vessel healing after everolimus-eluting stent implantation: 3-, 6-, and 12-month follow-up of optical coherence tomography
      Background Although a prospective randomized control study revealed that 3-month dual anti-platelet therapy (DAPT) is safe and does not compromise the efficacy of everolimus-eluting stent (EES) in selected patients, detailed vessel healing at early phase after EES implantation has yet to be investigated in Japanese patients. Methods and results A total of 27 lesions in 19 patients treated with EES were serially evaluated by using optical coherence tomography (OCT) at ...
      Read Full Article
    3. Lumen Boundaries Extracted from Coronary Computed Tomography Angiography on Computed Fractional Flow Reserve (FFRCT): Validation with Optical Coherence Tomography

      Lumen Boundaries Extracted from Coronary Computed Tomography Angiography on Computed Fractional Flow Reserve (FFRCT): Validation with Optical Coherence Tomography
      Aims: To evaluate the accuracy of minimal lumen area (MLA) by coronary computed tomography angiography (cCTA) and its impact on fractional flow reserve (FFRCT). Methods and results: Fifty-seven patients (118 lesions, 72 vessels) who underwent cCTA and optical coherence tomography (OCT) were enrolled. OCT and cCTA were co-registered and MLAs were measured with both modalities. FFROCT was calculated using OCT-updated models with cCTA-based lumen geometry replaced by OCT-derived geometry. Lesions ...
      Read Full Article
    4. Comparison between Optical COherence tomography guidance and Angiography guidance in percutaneous coronary intervention (COCOA): Study protocol for a randomized controlled trial

      Comparison between Optical COherence tomography guidance and Angiography guidance in percutaneous coronary intervention (COCOA): Study protocol for a randomized controlled trial
      Background Optical coherence tomography (OCT) is increasingly used as an adjunct to coronary angiography for guiding percutaneous coronary intervention (PCI). The current consensus on PCI is that the large final stent area offers the best chance of a good late clinical outcome. Since OCT provides more accurate information about the coronary artery and implanted stents, OCT-guided stent implantation is expected to achieve greater stent expansion than angiography guidance alone. Therefore ...
      Read Full Article
    5. Impact of CD14++CD16+ monocytes on coronary plaque vulnerability assessed by optical coherence tomography in coronary artery disease patients with well-regulated lipid levels

      Impact of CD14++CD16+ monocytes on coronary plaque vulnerability assessed by optical coherence tomography in coronary artery disease patients with well-regulated lipid levels
      Background and aims This study examined the impact of CD14 ++ CD16 + monocytes on coronary plaque vulnerability, as assessed by optical coherence tomography (OCT), and investigated their association with daily glucose fluctuation. Although increased CD14 ++ CD16 + monocyte levels have been reported to increase cardiovascular events, their impact on coronary plaque vulnerability in coronary artery disease (CAD) patients with or without diabetes mellitus (DM) remains unclear. Methods This prospective observational study included ...
      Read Full Article
    6. Early vascular responses to everolimus-eluting cobalt–chromium stent in the culprit lesions of st-elevation myocardial infarction: results from a multicenter prospective optical coherence tomography study (MECHANISM-AMI 2-week follow-up study)

      Early vascular responses to everolimus-eluting cobalt–chromium stent in the culprit lesions of st-elevation myocardial infarction: results from a multicenter prospective optical coherence tomography study (MECHANISM-AMI 2-week follow-up study)
      The use of cobaltchromium everolimus-eluting stents (CoCr-EES) for ST-segment elevation myocardial infarction (STEMI) reduces the incidence of stent thrombosis compared with bare metal stents, and a substantial difference is apparent in the initial 2 weeks. However, vascular behavior during this early period remains unclear. This was a prospective study (MECHANISM-AMI-2W) to investigate early vascular responses in STEMI patients immediately after CoCr-EES implantation and at 2-week follow-up using frequency domain-optical coherence ...
      Read Full Article
    7. Data on two- and three-dimensional optical coherence tomography guidance for the treatment for the bifurcation lesion

      Data on two- and three-dimensional optical coherence tomography guidance for the treatment for the bifurcation lesion
      This article comprised the data related to the research article entitled Feasibility and usefulness of three-dimensional optical coherence tomography guidance for optimal side branch treatment in coronary bifurcation stenting (Nagoshi et al., In press) [1] . In this article we reports details about two patterns of guide wire (GW) recrossing position after crossover stenting in bifurcation lesion classified with three-dimensional optical coherence tomography (3D-OCT) (Okamura et al., 2014) [2] and follow-up ...
      Read Full Article
    8. Impact of Guidewire Recrossing Point into Stent Jailed Side Branch for Optimal Kissing Balloon Dilatation - Corelab 3D Optical Coherence Tomography Analysis

      Impact of Guidewire Recrossing Point into Stent Jailed Side Branch for Optimal Kissing Balloon Dilatation - Corelab 3D Optical Coherence Tomography Analysis
      AIMS: We investigated the influence of the guidewire recrossing point on the incidence of incomplete stent apposition (ISA) after kissing balloon dilatation (KBD), and clinical and angiographic outcome at 9 months in a prospective multicenter registry. METHODS AND RESULTS: One hundred five patients underwent single crossover stenting across the side branch (SB) and subsequent KBD. Jailing configuration of the SB orifice and the guidewire recrossing position were assessed by off-line ...
      Read Full Article
    9. Optical Frequency Domain Imaging Versus Intravascular Ultrasound in Percutaneous Coronary Intervention (OPINION Trial) : Results From the OPINION Imaging Study

      Optical Frequency Domain Imaging Versus Intravascular Ultrasound in Percutaneous Coronary Intervention (OPINION Trial) : Results From the OPINION Imaging Study
      Objectives We sought to clarify how intravascular ultrasound (IVUS) and optical coherence tomography affect percutaneous coronary intervention (PCI) with current-generation drug-eluting stents in a pre-specified substudy of the OPINION (OPtical frequency domain imaging versus INtravascular ultrasound in percutaneous coronary interventiON) trial, a multicenter, prospective, randomized, noninferiority trial comparing optical frequency domain imaging (OFDI)-guided PCI with IVUS-guided PCI. Background The impact of these 2 imaging modalities in guiding PCI remains ...
      Read Full Article
    10. Feasibility and usefulness of three-dimensional optical coherence tomography guidance for optimal side branch treatment in coronary bifurcation stenting

      Feasibility and usefulness of three-dimensional optical coherence tomography guidance for optimal side branch treatment in coronary bifurcation stenting
      Background For the treatment of coronary bifurcation lesions, optimal guidewire (GW) recrossing after main vessel stenting is important for good stent apposition at the side branch (SB) orifice in kissing balloon inflation (KBI). Methods We analyzed 150 bifurcation lesions treated with single stenting following KBI in the three-dimensional optical coherence tomography (3D-OCT) bifurcation registry study (201516) and a single center experience (201216). OCT examination was performed after GW recrossing to ...
      Read Full Article
    11. Coronary risk factors associated with OCT macrophage images and their response after CoCr everolimus-eluting stent implantation in patients with stable coronary artery disease

      Coronary risk factors associated with OCT macrophage images and their response after CoCr everolimus-eluting stent implantation in patients with stable coronary artery disease
      Background and aims The aim of this study was to evaluate the accumulation of optical coherence tomography (OCT)-macrophages and OCT findings after CoCr everolimus-eluting stent placement, in addition to coronary risk factors. Methods A total of 89 lesions in 89 patients were registered in the 1- and 3-month cohort of the multi-centre study. Lesion characteristics and post-procedure OCT images were evaluated immediately and 1 and 3 months after stenting ...
      Read Full Article
    12. Optical frequency domain imaging vs. intravascular ultrasound in percutaneous coronary intervention (OPINION trial): one-year angiographic and clinical results

      Optical frequency domain imaging vs. intravascular ultrasound in percutaneous coronary intervention (OPINION trial): one-year angiographic and clinical results
      Aims Optical frequency domain imaging (OFDI) is a recently developed, light-based, high-resolution intravascular imaging technique. Intravascular ultrasound (IVUS) is a widely used, conventional imaging technique for guiding percutaneous coronary intervention (PCI). We aimed to demonstrate the non-inferiority of OFDI-guided PCI compared with IVUS-guided PCI in terms of clinical outcomes. Methods and results We did a prospective, multicentre, randomized (ratio 1:1), active-controlled, non-inferiority study to compare head-to-head OFDI vs. IVUS ...
      Read Full Article
    13. The impact of serum trans fatty acids concentration on plaque vulnerability in patients with coronary artery disease: Assessment via optical coherence tomography

      The impact of serum trans fatty acids concentration on plaque vulnerability in patients with coronary artery disease: Assessment via optical coherence tomography
      Background and aims Recent epidemiological studies have showed that excessive intake of trans fatty acids (TFA) can be a residual risk for the development of coronary artery disease (CAD) even under medical management, including statins. This study aimed at investigating the association between lipid profile, including serum TFA concentration, and plaque vulnerability using optical coherence tomography (OCT). Methods Level of serum elaidic acid, a major TFA component, was measured using ...
      Read Full Article
    14. Two-year vascular responses to drug-eluting stents with biodegradable polymer versus durable polymer: An optical coherence tomography sub-study of the NEXT

      Two-year vascular responses to drug-eluting stents with biodegradable polymer versus durable polymer: An optical coherence tomography sub-study of the NEXT
      Background This study aimed to compare very late vascular response after stent implantation between everolimus-eluting stent (EES) with a thin, non-adhesive, durable, biocompatible fluorinated polymer and biolimus-eluting stent (BES) with a biodegradable polymer by optical coherence tomography (OCT). Methods and results In the NOBORI-BES Versus XIENCE V/PROMUS-EES Trial (NEXT), a formal OCT substudy investigated 48 patients (27 EES-treated lesions in 23 patients and 28 BES-treated lesions in 25 patients ...
      Read Full Article
    15. Effects of daily glucose fluctuations on the healing response to everolimus-eluting stent implantation as assessed using continuous glucose monitoring and optical coherence tomography

      Effects of daily glucose fluctuations on the healing response to everolimus-eluting stent implantation as assessed using continuous glucose monitoring and optical coherence tomography
      Background Several studies have revealed that glucose fluctuations provoke oxidative stress that leads to endothelial cell dysfunction, progression of coronary atherosclerosis, and plaque vulnerability. However, little is known regarding their effect on neointimal growth after stenting in patients with coronary artery disease (CAD). We aimed to investigate the effects of glucose fluctuations on neointimal growth after everolimus-eluting stent (EES) implantation. Methods This study examined 50 patients who underwent a 9-month ...
      Read Full Article
    16. Impact of final kissing balloon inflation on vessel healing following drug-eluting stent implantation: Insight from the optical coherence tomography sub-study of the J-REVERSE trial

      Impact of final kissing balloon inflation on vessel healing following drug-eluting stent implantation: Insight from the optical coherence tomography sub-study of the J-REVERSE trial
      Background We sought to clarify the impact of final kissing inflation (FKI) after single stenting of bifurcation lesions on vessel healing. Methods From the J-REVERSE registry enrolling 303 bifurcation lesions treated with provisional single stenting using sirolimus- (SES) or everolimus-eluting stent (EES), 65 lesions treated with ( n = 30) and without ( n = 35) FKI underwent 9-month follow-up optical coherence tomography. Average stent eccentricity index (SEI: minimum/maximum stent diameter) and neointimal ...
      Read Full Article
    17. 1-15 of 64 1 2 3 4 5 »
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. About Toshiro Shinke

    Toshiro Shinke is an MD in cardiology at Department of Internal Medicine, Division of Cardiovascular and Respiratory Medicine, Kobe University Graduate School of Medicine, Japan.