1. Takayuki Okamura

    0 Comments Leave a Comment

    1-15 of 39 1 2 3 »
    1. Mentioned In 39 Articles

    2. Impact of Guidewire Recrossing Point into Stent Jailed Side Branch for Optimal Kissing Balloon Dilatation - Corelab 3D Optical Coherence Tomography Analysis

      Impact of Guidewire Recrossing Point into Stent Jailed Side Branch for Optimal Kissing Balloon Dilatation - Corelab 3D Optical Coherence Tomography Analysis
      AIMS: We investigated the influence of the guidewire recrossing point on the incidence of incomplete stent apposition (ISA) after kissing balloon dilatation (KBD), and clinical and angiographic outcome at 9 months in a prospective multicenter registry. METHODS AND RESULTS: One hundred five patients underwent single crossover stenting across the side branch (SB) and subsequent KBD. Jailing configuration of the SB orifice and the guidewire recrossing position were assessed by off-line ...
      Read Full Article
    3. Serial changes in the side-branch ostial area after main-vessel stenting with kissing balloon inflation for coronary bifurcation lesions, assessed by 3D optical coherence tomography

      Serial changes in the side-branch ostial area after main-vessel stenting with kissing balloon inflation for coronary bifurcation lesions, assessed by 3D optical coherence tomography
      Aims We evaluated the influence of the jailing configuration and guidewire rewiring position in front of the side-branch (SB) ostium before kissing balloon inflation (KBI) against side-branch ostial area (SBOA) at follow-up using 3D optical coherence tomography (3D-OCT). Methods and results We retrospectively analysed the cases of the 37 consecutive patients who underwent main-vessel (MV) stenting with KBI for coronary bifurcation lesion under OCT guidance and the follow-up OCT 612months ...
      Read Full Article
      Mentions: Takayuki Okamura
    4. Optical Frequency Domain Imaging Versus Intravascular Ultrasound in Percutaneous Coronary Intervention (OPINION Trial) : Results From the OPINION Imaging Study

      Optical Frequency Domain Imaging Versus Intravascular Ultrasound in Percutaneous Coronary Intervention (OPINION Trial) : Results From the OPINION Imaging Study
      Objectives We sought to clarify how intravascular ultrasound (IVUS) and optical coherence tomography affect percutaneous coronary intervention (PCI) with current-generation drug-eluting stents in a pre-specified substudy of the OPINION (OPtical frequency domain imaging versus INtravascular ultrasound in percutaneous coronary interventiON) trial, a multicenter, prospective, randomized, noninferiority trial comparing optical frequency domain imaging (OFDI)-guided PCI with IVUS-guided PCI. Background The impact of these 2 imaging modalities in guiding PCI remains ...
      Read Full Article
    5. Feasibility and usefulness of three-dimensional optical coherence tomography guidance for optimal side branch treatment in coronary bifurcation stenting

      Feasibility and usefulness of three-dimensional optical coherence tomography guidance for optimal side branch treatment in coronary bifurcation stenting
      Background For the treatment of coronary bifurcation lesions, optimal guidewire (GW) recrossing after main vessel stenting is important for good stent apposition at the side branch (SB) orifice in kissing balloon inflation (KBI). Methods We analyzed 150 bifurcation lesions treated with single stenting following KBI in the three-dimensional optical coherence tomography (3D-OCT) bifurcation registry study (201516) and a single center experience (201216). OCT examination was performed after GW recrossing to ...
      Read Full Article
    6. Serial 5-Year Evaluation of Side Branches Jailed by Bioresorbable Vascular Scaffolds Using 3-Dimensional Optical Coherence Tomography

      Serial 5-Year Evaluation of Side Branches Jailed by Bioresorbable Vascular Scaffolds Using 3-Dimensional Optical Coherence Tomography
      Background The long-term fate of Absorb bioresorbable vascular scaffold (Abbott Vascular, Santa Clara, CA) struts jailing side branch ostia has not been clarified. We therefore evaluate serially (post-procedure and at 6 months, 1, 2, 3, and 5 years) the appearance and fate of jailed Absorb bioresorbable vascular scaffold struts. Methods and Results We performed 3-dimensional optical coherence tomographic analysis of the ABSORB Cohort B trial (A Clinical Evaluation of the ...
      Read Full Article
    7. Optical frequency domain imaging vs. intravascular ultrasound in percutaneous coronary intervention (OPINION trial): one-year angiographic and clinical results

      Optical frequency domain imaging vs. intravascular ultrasound in percutaneous coronary intervention (OPINION trial): one-year angiographic and clinical results
      Aims Optical frequency domain imaging (OFDI) is a recently developed, light-based, high-resolution intravascular imaging technique. Intravascular ultrasound (IVUS) is a widely used, conventional imaging technique for guiding percutaneous coronary intervention (PCI). We aimed to demonstrate the non-inferiority of OFDI-guided PCI compared with IVUS-guided PCI in terms of clinical outcomes. Methods and results We did a prospective, multicentre, randomized (ratio 1:1), active-controlled, non-inferiority study to compare head-to-head OFDI vs. IVUS ...
      Read Full Article
    8. Intracoronary optical coherence tomography: Clinical and research applications and intravascular imaging software overview

      Intracoronary optical coherence tomography: Clinical and research applications and intravascular imaging software overview
      By providing valuable information about the coronary artery wall and lumen, intravascular imaging may aid in optimizing interventional procedure results and thereby could improve clinical outcomes following percutaneous coronary intervention (PCI). Intravascular optical coherence tomography (OCT) is a light-based technology with a tissue penetration of approximately 1 to 3 mm and provides near histological resolution. It has emerged as a technological breakthrough in intravascular imaging with multiple clinical and research ...
      Read Full Article
    9. Safety of optical coherence tomography in daily practice: a comparison with intravascular ultrasound

      Safety of optical coherence tomography in daily practice: a comparison with intravascular ultrasound
      Aims Previous studies have reported the safety and feasibility of both time-domain optical coherence tomography (TD-OCT) and Fourier-domain OCT (FD-OCT) in highly selected patients and clinical settings. However, the generalizability of these data is limited, and data in unselected patient populations reflecting a routine cathlab practice are lacking. We compared safety of intracoronary FD-OCT imaging to intravascular ultrasound (IVUS) imaging in a large real-world series of consecutive patients who underwent ...
      Read Full Article
    10. Three-dimensional reconstruction of optical coherence tomography for improving bifurcation stenting

      Three-dimensional reconstruction of optical coherence tomography for improving bifurcation stenting
      Coronary bifurcation lesions are encountered in approximately 1520% of all percutaneous coronary interventions (PCIs) [1] . Bifurcation PCI has historically been associated with lower procedural success rates and higher long-term adverse event rates compared with PCI for non-bifurcation lesions. In the drug-eluting stent (DES) era, the clinical outcomes for bifurcation PCI have improved considerably [2] . However, bifurcation stenting is still technically challenging and associated with an increased risk of stent thrombosis ...
      Read Full Article
    11. Optical frequency domain imaging vs. intravascular ultrasound in percutaneous coronary intervention (OPINION trial): Study protocol for a randomized controlled trial

      Optical frequency domain imaging vs. intravascular ultrasound in percutaneous coronary intervention (OPINION trial): Study protocol for a randomized controlled trial
      Background Optical coherence tomography is becoming increasingly widespread as an adjunctive intravascular diagnostic technique in percutaneous coronary intervention (PCI), because of its ability to visualize coronary structures at high resolution. Several studies have reported that intravascular ultrasound (IVUS) guidance in PCI might be helpful to reduce subsequent stent thrombosis, restenosis, repeat revascularization, myocardial infarction, and cardiac death. The OPtical frequency domain imaging vs. INtravascular ultrasound in percutaneous coronary InterventiON (OPINION ...
      Read Full Article
    12. New implication of three-dimensional optical coherence tomography in optimising bifurcation PCI

      New implication of three-dimensional optical coherence tomography in optimising bifurcation PCI
      With the advance of optical coherence tomography (OCT) technology, three-dimensional (3D) reconstruction based on the optical coherence tomography has become feasible. In bifurcation lesions, 3D OCT may guide positioning of the wire through the appropriate (distal) cells. The early studies suggested that such a guidance strategy could reduce the incidence of malapposition in bifurcation lesions. The pre-installed real-time 3D OCT on the console will promote the utilisation of 3D assessment ...
      Read Full Article
    13. Comparison of neointimal coverage and extra-stent lumen between sirolimus and everolimus-eluting stent using optical coherence tomography

      Comparison of neointimal coverage and extra-stent lumen between sirolimus and everolimus-eluting stent using optical coherence tomography
      The external lumen of a stent [defined as extra-stent lumen (ESL)] assessed by optical coherence tomography (OCT) may be related to the risk of thrombus formation after sirolimus-eluting stent (SES) implantation. An everolimus-eluting stent (EES) might provide relatively minimal inflammatory reaction and appropriate neointimal coverage. The purpose of this study was to compare the neointimal thickness and ESL between SES and EES. Patients who underwent OCT examination more than 7 ...
      Read Full Article
      Mentions: Takayuki Okamura
    14. 3D optical coherence tomography: new insights into the process of optimal rewiring of side branches during bifurcational stenting

      3D optical coherence tomography: new insights into the process of optimal rewiring of side branches during bifurcational stenting
      Aims: We describe three-dimensional optical coherence tomography (3D-OCT) guided bifurcation stenting and the clinical utility of 3D-OCT. Methods and results: Twenty-two consecutive patients who underwent OCT examination to confirm the recrossing position after stent implantation in a bifurcation lesion were enrolled. Frequency domain OCT images were obtained to check the recrossing position and 3D reconstructions were performed off-line. The recrossing position was clearly visualised in 18/22 (81.8%) cases ...
      Read Full Article
    15. Serial three-dimensional optical coherence tomography assessment of strut coverage and intraluminal structures after drug-eluting stent implantation

      Serial three-dimensional optical coherence tomography assessment of strut coverage and intraluminal structures after drug-eluting stent implantation
      Understanding of intraluminal structure and distribution of uncovered struts after drug-eluting stent implantation are limited by only 2-dimensional (2D) optical coherence tomography (OCT) images. We compared tissue coverage with 3-dimensional (3D) OCT and 2D quantitative analyses, and changes in intraluminal structure immediately after (baseline) everolimus-eluting stent (EES) implantation and at follow-up. The 2D analyses of uncovered struts ratio and tissue coverage thickness at a 0.5-mm interval were compared to ...
      Read Full Article
      Mentions: Takayuki Okamura
    16. 1-15 of 39 1 2 3 »
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. About Takayuki Okamura

    Takayuki Okamura is a Cardiologist at the Thoraxcenter, Erasmus University Medical Center, Rotterdam, the Netherlands and also affiliated with Yamaguchi University in Japan.