1. Takashi Akasaka

    0 Comments Leave a Comment

    1-15 of 129 1 2 3 4 5 6 7 8 9 »
    1. Mentioned In 129 Articles

    2. OPtical Coherence Tomography Guided Coronary Stent IMplantation Compared to Angiography: A Multicenter Randomized TriaL in PCI

      OPtical Coherence Tomography Guided Coronary Stent IMplantation Compared to Angiography: A Multicenter Randomized TriaL in PCI
      AIMS: Randomized trials have demonstrated improvement in clinical outcomes with intravascular ultrasound (IVUS)-guided percutaneous coronary intervention (PCI) compared with angiography-guided PCI. The ILUMIEN III trial demonstrated non-inferiority of an optical coherence tomography (OCT)- versus IVUS-guided PCI strategy in achieving similar post-PCI lumen dimensions. ILUMIEN IV is a large-scale, multicenter, randomized trial designed to demonstrate the superiority of OCT- versus angiography-guided stent implantation in patients with high-risk clinical characteristics (diabetes ...
      Read Full Article
    3. Outcomes of Optical Coherence Tomography Compared With Intravascular Ultrasound and With Angiography to Guide Coronary Stent Implantation: One-Year Results from the ILUMIEN III: OPTIMIZE PCI trial

      Outcomes of Optical Coherence Tomography Compared With Intravascular Ultrasound and With Angiography to Guide Coronary Stent Implantation: One-Year Results from the ILUMIEN III: OPTIMIZE PCI trial
      Aims: In the ILUMIEN III trial, among 450 randomised patients with non-complex lesions undergoing percutaneous coronary intervention (PCI), optical coherence tomography (OCT) guidance led to greater stent expansion than angiography guidance, similar minimal stent area compared to both intravascular ultrasound (IVUS) guidance and angiography guidance, and lower rates of uncorrected dissection and malapposition than both IVUS guidance and angiography guidance. Whether these differences impact clinical outcomes is unknown. Methods and ...
      Read Full Article
    4. Optical Coherence Tomography Comparison of Percutaneous Coronary Intervention Among Plaque Rupture, Erosion, and Calcified Nodule in Acute Myocardial Infarction

      Optical Coherence Tomography Comparison of Percutaneous Coronary Intervention Among Plaque Rupture, Erosion, and Calcified Nodule in Acute Myocardial Infarction
      Background: Acute myocardial infarction (AMI) is caused by coronary plaque rupture (PR), plaque erosion (PE), or calcified nodule (CN). We used optical coherence tomography (OCT) to compare stent expansion immediately after primary percutaneous coronary intervention (PCI) in patients with AMI caused by PR, PE, or CN. Methods and Results: In all, 288 AMI patients were assessed by OCT before and immediately after PCI, performed with OCT guidance according to OPINION ...
      Read Full Article
    5. Extent of the difference between microcatheter and pressure wire-derived fractional flow reserve and its relation to optical coherence tomography-derived parameters

      Extent of the difference between microcatheter and pressure wire-derived fractional flow reserve and its relation to optical coherence tomography-derived parameters
      Background Although previous studies demonstrated that microcatheter-derived fractional flow reserve (mc-FFR) tends to overestimate lesion severity compared to pressure wire-derived FFR (pw-FFR), the clinical utility of mc-FFR remains obscure. The extent of differences between the two FFR systems and its relation to a lesion-specific parameter remain unknown. In this study, we sought to compare mc-FFR with pw-FFR and determine the lower and upper mc-FFR cut-offs predicting ischemic and non-ischemic stenosis ...
      Read Full Article
    6. Comparison of Diagnostic Performance of Intracoronary Optical Coherence Tomography-based and Angiography-based Fractional Flow Reserve for Evaluation of Coronary Stenosis

      Comparison of Diagnostic Performance of Intracoronary Optical Coherence Tomography-based and Angiography-based Fractional Flow Reserve for Evaluation of Coronary Stenosis
      Aims: To evaluate the diagnostic performance of OCT-based optical flow ratio (OFR) in unselected patients and compare it with angiography-based quantitative flow ratio (QFR), using wire-based FFR as reference standard. Methods and results: All patients with OCT and FFR assessment prior to revascularization were analyzed. OFR and QFR were computed in blinded fashion and compared with FFR, all applying same cut-off value of 0.80 to define ischemia. Paired comparison ...
      Read Full Article
    7. A Local Multi-Layer Model for Tissue Classification of in-vivo Atherosclerotic Plaques in Intravascular Optical Coherence Tomography

      A Local Multi-Layer Model for Tissue Classification of in-vivo Atherosclerotic Plaques in Intravascular Optical Coherence Tomography
      Clinical researches show that the morbidity of coronary artery disease (CAD) is gradually increasing in many countries every year, and it causes hundreds of thousands of people all over the world dying for each year. As the optical coherence tomography with high resolution and better contrast applied to the lesion tissue investigation of human vessel, many more micro-structures of the vessel could be easily and clearly visible to doctors, which ...
      Read Full Article
    8. Expert consensus statement for quantitative measurement and morphological assessment of optical coherence tomography

      Expert consensus statement for quantitative measurement and morphological assessment of optical coherence tomography
      In this document, the methods for the quantitative measurement and morphological assessment of optical coherence tomography (OCT)/optical frequency domain imaging images (OFDI) are briefly summarized. The focus is on the clinical application of OCT/OFDI to guide percutaneous coronary interventions.
      Read Full Article
    9. Intracoronary pressure increase due to contrast injection for optical coherence tomography imaging

      Intracoronary pressure increase due to contrast injection for optical coherence tomography imaging
      Background Optical coherence tomography (OCT) requires intracoronary injection of contrast media to remove blood from the field of view during image acquisition. Contrast injection may cause a temporal increase in intracoronary pressure. The aim of this study was to compare the intracoronary pressure during contrast injection between OCT and coronary angiography . Methods We measured intracoronary pressure by using a pressure guidewire during contrast injection for OCT and angiography in 30 ...
      Read Full Article
    10. Clinical use of intracoronary imaging. Part 2: acute coronary syndromes, ambiguous coronary angiography findings, and guiding interventional decision-making: an expert consensus document of the European Association of Percutaneous Cardiovascular Intervent

      Clinical use of intracoronary imaging. Part 2: acute coronary syndromes, ambiguous coronary angiography findings, and guiding interventional decision-making: an expert consensus document of the European Association of Percutaneous Cardiovascular Intervent
      This consensus document is the second of two reports summarizing the views of an expert panel organized by the European Association of Percutaneous Cardiovascular Interventions (EAPCI) on the clinical use of intracoronary imaging including intravascular ultrasound (IVUS), optical coherence tomography (OCT), and near infrared spectroscopy (NIRS)-IVUS. Beyond guidance of stent selection and optimization of deployment, invasive imaging facilitates angiographic interpretation and may guide treatment in acute coronary syndrome. Intravascular ...
      Read Full Article
    11. Early and mid-term vascular responses to optical coherence tomography guided everolimus-eluting stent implantation in stable coronary artery disease

      Early and mid-term vascular responses to optical coherence tomography guided everolimus-eluting stent implantation in stable coronary artery disease
      Background Analysis of pooled clinical data has shown the safety of 3 months of dual antiplatelet therapy (DAPT) with everolimus-eluting cobaltchromium stents (Co-Cr EESs). This study evaluated early and mid-term vascular responses to Co-Cr EESs in patients with stable coronary artery disease (CAD). Methods The MECHANISM-Elective trial (NCT02014818) is a multicenter optical coherence tomography (OCT) registry. Enrolled patients were evaluated by OCT immediately after EES implantation (post), were prospectively allocated ...
      Read Full Article
    12. Plaque burden can be assessed using intravascular optical coherence tomography and a dedicated automated processing algorithm: a comparison study with intravascular ultrasound

      Plaque burden can be assessed using intravascular optical coherence tomography and a dedicated automated processing algorithm: a comparison study with intravascular ultrasound
      Aims Plaque burden (PB) measurement using intravascular optical coherence tomography (IVOCT) is currently thought to be inferior to intravascular ultrasound (IVUS). We developed an automated IVOCT image processing algorithm to enhance the external elastic lamina (EEL) contour. Thus, we investigated the accuracies of standard IVOCT and an IVOCT enhancement algorithm for measuring PB using IVUS as the reference standard. Methods and results The EEL-enhancement algorithm combined adaptive attenuation compensation, exponentiation ...
      Read Full Article
    13. Imaging assessment and accuracy in coronary artery autopsy: comparison of frequency-domain optical coherence tomography with intravascular ultrasound and histology

      Imaging assessment and accuracy in coronary artery autopsy: comparison of frequency-domain optical coherence tomography with intravascular ultrasound and histology
      ptical coherence tomography (OCT) is a coronary artery imaging technique with high resolution. Second-generation frequency-domain OCT (FD-OCT) technology allows safer and faster clinical application compared with first-generation time-domain OCT (TD-OCT). Only limited validation studies compare FD-OCT with other modes of analysis: histology, which is the current gold standard, and intravascular ultrasound (IVUS). This study therefore aims to demonstrate the accuracy of FD-OCT images compared with IVUS and histology. FD-OCT and ...
      Read Full Article
    14. Optical coherence tomography in varying aetiologies of renal artery stenosis: a case series

      Optical coherence tomography in varying aetiologies of renal artery stenosis: a case series
      Background Renal artery stenosis (RAS) is a common cause of secondary hypertension. The most common aetiology is atherosclerosis; however, other causes like fibromuscular dysplasia (FMD) and Takayasu arteritis (TA) are also frequently encountered. The lesion characteristics and its response to percutaneous intervention depend upon the aetiology of RAS. Optical coherence tomography (OCT) is an excellent imaging modality to analyse coronary lesions during percutaneous coronary interventions. The data regarding the utility ...
      Read Full Article
      Mentions: Takashi Akasaka
    15. Clinical use of intracoronary imaging. Part 2: acute coronary syndromes, ambiguous coronary angiography findings, and guiding interventional decision-making: an expert consensus document of the European Association of Percutaneous Cardiovascular Intervent

      Clinical use of intracoronary imaging. Part 2: acute coronary syndromes, ambiguous coronary angiography findings, and guiding interventional decision-making: an expert consensus document of the European Association of Percutaneous Cardiovascular Intervent
      This consensus document is the second of two reports summarizing the views of an expert panel organized by the European Association of Percutaneous Cardiovascular Interventions (EAPCI) on the clinical use of intracoronary imaging including intravascular ultrasound (IVUS), optical coherence tomography (OCT), and near infrared spectroscopy (NIRS)-IVUS. Beyond guidance of stent selection and optimization of deployment, invasive imaging facilitates angiographic interpretation and may guide treatment in acute coronary syndrome. Intravascular ...
      Read Full Article
    16. Stabilization of High Risk Coronary Plaque on Optical Coherence Tomography and Near-Infrared Spectroscopy by Intensive Lipid-Lowering Therapy With Proprotein Convertase Subtilisin/Kexin Type 9 (PCSK9) Inhibitor

      Stabilization of High Risk Coronary Plaque on Optical Coherence Tomography and Near-Infrared Spectroscopy by Intensive Lipid-Lowering Therapy With Proprotein Convertase Subtilisin/Kexin Type 9 (PCSK9) Inhibitor
      A 70-year-old woman with hypertension and dyslipidemia underwent drug-eluting stent implantation in the mid-left anterior descending artery (LAD) due to acute coronary syndrome (ACS). Optical coherence tomography (OCT) during the index procedure showed lipid-rich plaque in non-culprit lesions of the proximal LAD and mid-right coronary artery (Figure B,E). Near-infrared spectroscopy-intravascular ultrasound (NIRS-IVUS) showed plaque with high lipid burden in both sites (Figure C,F). Intensive lipid-lowering therapy with combined ...
      Read Full Article
    17. 1-15 of 129 1 2 3 4 5 6 7 8 9 »
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. About Takashi Akasaka

    Takashi Akasaka, MD, is at Department of Cardiovascular Medicine, Wakayama Medical University, Japan.

  3. Quotes

    1. The ILUMIEN OPTIS system enables a higher image resolution, and thus makes it possible for us to analyze difficult anatomical structures, allowing me to focus on diagnostic and treatment strategies.
      In St Jude OCT system to aid treatment of coronary artery disease