1. Peng Li

    0 Comments Leave a Comment

    1-15 of 35 1 2 3 »
    1. Mentioned In 35 Articles

    2. All-fiber probe for optical coherence tomography with an extended depth of focus by a high-efficient fiber-based filter

      All-fiber probe for optical coherence tomography with an extended depth of focus by a high-efficient fiber-based filter
      Although methods have been proposed to maintain high transverse resolution over an increased depth range, it is not straightforward to scale down the bulk-optic solutions to minimized probes of optical coherence tomography (OCT). In this paper, we propose a high-efficient fiber-based filter in an all-fiber OCT probe to realize an extended depth of focus (DOF) while maintaining a high transverse resolution. Mode interference in the probe is exploited to modulate ...
      Read Full Article
    3. Adaptive classifier allows enhanced flow contrast in OCT angiography using a histogram-based motion threshold and 3D Hessian analysis-based shape filtering

      Adaptive classifier allows enhanced flow contrast in OCT angiography using a histogram-based motion threshold and 3D Hessian analysis-based shape filtering
      In this Letter, we propose an adaptive digital classifier for flow contrast enhancement in optical coherence tomography angiography (OCTA). To solve the depth dependence in the initial motion-based classification, a depth-adaptive motion threshold was determined by performing a histogram analysis of an en-face image at each depth and identifying the static and dynamic voxel populations through fitting. In the follow-up shape-based classification, to adapt to the deformed vessel shapes in ...
      Read Full Article
    4. Quasi-needle-like focus synthesized by optical coherence tomography

      Quasi-needle-like focus synthesized by optical coherence tomography
      It is known that lateral resolution and depth of focus (DOF) in an optical imaging system are coupled, and a compromise between them has to be made. In this Letter, we propose to resolve the trade-off between lateral resolution and the DOF by a synthetic effective point spread function in optical path length (OPL) domain. A quasi-needle-like focus is synthesized by optical coherence tomography. We demonstrate that the synthesized quasi-needle-like ...
      Read Full Article
    5. Motion correction using overlapped data correlation based on a spatial-spectral encoded parallel optical coherence tomography

      Motion correction using overlapped data correlation based on a spatial-spectral encoded parallel optical coherence tomography
      This paper presents an approach to remove motion artifacts based on a spatial-spectral encoded parallel OCT (SSE-POCT) system, where encoded rectangular illumination is employed. Motion artifacts within a B-scan are avoided due to parallel detection intrinsic to parallel OCT, while those between successive B-scans are estimated and corrected by a proposed overlapped data correlation (ODC) algorithm. To preserve axial resolution, decoded B-scan corresponding to complete spectrum is stitched from successive ...
      Read Full Article
    6. A useful way to develop effective in vivo skin optical clearing agents

      A useful way to develop effective in vivo skin optical clearing agents
      Skin optical clearing has shown tremendous potential in improving various optical imaging performances, but there is some certain blindness in screening out high-efficiency in vivo optical clearing methods. In this work, three optical clearing agents: sucrose (Suc), fructose (Fruc) and PEG-400 (PEG), and two chemical penetration enhancers: propylene glycol (PG) and thiazone (Thiaz) were used. PEG was firstly mixed with the two penetration enhancers, respectively, and then mixed with Fruc ...
      Read Full Article
    7. Angular compounding by full-channel B-scan modulation encoding for optical coherence tomography speckle reduction

      Angular compounding by full-channel B-scan modulation encoding for optical coherence tomography speckle reduction
      We describe an angular compounding method by full-channel B-scan modulation encoding for speckle reduction in optical coherence tomography. The complex-valued spectral interferogram (SI) is reconstructed by removing one of the conjugate terms in the depth space. Fourier transform of the complex SI along the lateral direction enables a full-channel (with both negative and positive Fourier space) for B-scan modulation in the spatial frequency ( ) domain. A full-size probe beam, determined by ...
      Read Full Article
    8. Hybrid averaging offers high-flow contrast by cost apportionment among imaging time, axial, and lateral resolution in optical coherence tomography angiography

      Hybrid averaging offers high-flow contrast by cost apportionment among imaging time, axial, and lateral resolution in optical coherence tomography angiography
      The current temporal, wavelength, angular, and spatial averaging approaches trade imaging time and resolution for multiple independent measurements that improve the flow contrast in optical coherence tomography angiography (OCTA). We find that these averaging approaches are equivalent in principle, offering almost the same flow contrast enhancement as the number of averages increases. Based on this finding, we propose a hybrid averaging strategy for contrast enhancement by cost apportionment. We demonstrate ...
      Read Full Article
    9. Ophthalmic optical coherence tomography system and method for quick switching to realize anterior and posterior eye segments imaging

      Ophthalmic optical coherence tomography system and method for quick switching to realize anterior and posterior eye segments imaging
      An ophthalmic optical coherence tomography system and a method for quick switching to realize anterior and posterior eye segments imaging are provided, the system includes: an OCT interferometer primary module and a sample arm module, the OCT interferometer primary module includes an OCT light source, a fiber coupler, a reference arm, a detection module, an X-direction scanning unit, and a Y-direction scanning unit; the sample arm module includes an anterior ...
      Read Full Article
    10. Optical coherence tomography angiography offers comprehensive evaluation of skin optical clearing in vivo by quantifying optical properties and blood flow imaging simultaneously

      Optical coherence tomography angiography offers comprehensive evaluation of skin optical clearing in vivo by quantifying optical properties and blood flow imaging simultaneously
      Tissue optical clearing (TOC) is helpful for reducing scattering and enhancing the penetration depth of light, and shows promising potential in optimizing optical imaging performances. A mixture of fructose with PEG-400 and thiazone (FPT) is used as an optical clearing agent in mouse dorsal skin and evaluated with OCT angiography (Angio-OCT) by quantifying optical properties and blood flow imaging simultaneously. It is observed that FPT leads to an improved imaging ...
      Read Full Article
    11. Single-shot angular compounded optical coherence tomography angiography by splitting full-space B-scan modulation spectrum for flow contrast enhancement

      Single-shot angular compounded optical coherence tomography angiography by splitting full-space B-scan modulation spectrum for flow contrast enhancement
      We proposed a single-shot spatial angular compounded optical coherence tomography angiography (AC-Angio-OCT) for blood flow contrast enhancement. By encoding incident angles in B-scan modulation frequencies and splitting the modulation spectrum in the spatial frequency domain, angle-resolved independent subangiograms were obtained and compounded to improve the flow contrast. A full space of the spatial frequency domain allows a wide modulation spectrum. To get access to the full space of the spatial ...
      Read Full Article
    12. Improved motion contrast and processing efficiency in OCT angiography using complex-correlation algorithm

      Improved motion contrast and processing efficiency in OCT angiography using complex-correlation algorithm
      The complex-based OCT angiography (Angio-OCT) offers high motion contrast by combining both the intensity and phase information. However, due to involuntary bulk tissue motions, complex-valued OCT raw data are processed sequentially with different algorithms for correcting bulk image shifts (BISs), compensating global phase fluctuations (GPFs) and extracting flow signals. Such a complicated procedure results in massive computational load. To mitigate such a problem, in this work, we present an inter-frame ...
      Read Full Article
    13. Statistical analysis of motion contrast in optical coherence tomography angiography

      Statistical analysis of motion contrast in optical coherence tomography angiography
      Optical coherence tomography angiography (Angio-OCT), mainly based on the temporal dynamics of OCT scattering signals, has found a range of potential applications in clinical and scientific research. Based on the model of random phasor sums, temporal statistics of the complex-valued OCT signals are mathematically described. Statistical distributions of the amplitude differential and complex differential Angio-OCT signals are derived. The theories are validated through the flow phantom and live animal experiments ...
      Read Full Article
    14. Assessment of Full-Eye Response to Osmotic Stress in Mouse Model In Vivo Using Optical Coherence Tomography

      Assessment of Full-Eye Response to Osmotic Stress in Mouse Model In Vivo Using Optical Coherence Tomography
      NaCl based solutions were applied as osmotic stress agents to alter the hydration state of the mouse eye. Full-eye responses to these osmotic challenges were monitored in vivo using a custom-built optical coherence tomography (OCT) with an extended imaging range of 12.38mm. Dynamic changes in the mouse eye were quantified based on the OCT images using several parameters, including the central corneal thickness (CCT), the anterior chamber depth (ACD ...
      Read Full Article
    15. Statistical analysis of motion contrast in optical coherence tomography angiography

      Statistical analysis of motion contrast in optical coherence tomography angiography
      Optical coherence tomography angiography (Angio-OCT), mainly based on the temporal dynamics of OCT scattering signals, has found a range of potential applications in clinical and scientific researches. In this work, based on the model of random phasor sums, temporal statistics of the complex-valued OCT signals are mathematically described. Statistical distributions of the amplitude differential (AD) and complex differential (CD) Angio-OCT signals are derived. The theories are validated through the flow ...
      Read Full Article
    16. Identification of surface defects on glass by parallel spectral domain optical coherence tomography

      Identification of surface defects on glass by parallel spectral domain optical coherence tomography
      Defects can dramatically degrade glass quality, and automatic inspection is a trend of quality control in modern industry. One challenge in inspection in an uncontrolled environment is the misjudgment of fake defects (such as dust particles) as surface defects. Fortunately, optical changes within the periphery of a surface defect are usually introduced while those of a fake defect are not. The existence of changes within the defect peripheries can be ...
      Read Full Article
    17. 1-15 of 35 1 2 3 »
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. About Peng Li

    Peng Li

    Peng Li is an associate professor in the State Key Laboratory of Modern Optical Instrumentation at Zhejiang University.