1. Optovue

    0 Comments Leave a Comment

    661-675 of 756 « 1 2 ... 42 43 44 45 46 47 48 ... 49 50 51 »
    1. Mentioned In 756 Articles

    2. Versatile corneal, anterior segment imaging technologies improve accuracy

      Versatile corneal, anterior segment imaging technologies improve accuracy
      An eclectic array of anterior segment testing and measurement technologies enable cataract and refractive surgeons to accurately assess anatomic features to optimize clinical and visual outcomes. Anterior segment optical coherence tomography, very high-frequency ultrasound biomicroscopy and Scheimpflug photography help surgeons assess corneal thickness and topography, anterior chamber depth and axial length, and iris and ciliary body status. Used alone or in combination, these modalities also help surgeons manage complications.
      Read Full Article
    3. Diagnostic capability of Fourier-Domain optical coherence tomography in early primary open angle glaucoma

      Diagnostic capability of Fourier-Domain optical coherence tomography in early primary open angle glaucoma
      Background Optical coherence tomography (OCT) is a high resolution noncontact imaging modality which can quantitatively detect the optic disc and retinal structure. This study was designed to evaluate the diagnostic capability of parameters of the optic disc, retinal nerve fiber layer thickness, and ganglion cell complex (GCC) using a new technology called Fourier-domain OCT (FD-OCT) for early primary open angle glaucoma (POAG) patients.Methods Two groups of patients, early perimetric ...
      Read Full Article
    4. Evaluation of bilateral minimum thickness of normal corneas based on Fourier-domain optical coherence tomography

      Evaluation of bilateral minimum thickness of normal corneas based on Fourier-domain optical coherence tomography
      Purpose: To determine the normative ranges and various aspects of the relationship between the minimum corneal thicknesses (MCT) in fellow eyes and the location of the MCT in relation to the central cornea using Fourier-domain optical coherence tomography (OCT).Setting: Tertiary care ophthalmic hospital, Chennai, India.Methods: In this cross-sectional observational trial, both eyes of consecutive healthy young subjects with a low refractive error and no clinical or topographic evidence ...
      Read Full Article
    5. Method of eye examination by optical coherence tomography

      Method of eye examination by optical coherence tomography
      A method of performing an OCT image scan is presented. Other images are taken and a template is formed to correct the OCT images, for example, for eye motion, blood vessel placement, and center offset. In some embodiments, video images are taken simultaneously with the OCT images and utilized to correct the OCT images. In some embodiments, a template OCT image is formed prior to acquisition of the OCT images ...
      Read Full Article
    6. Diagnostic Power of Optic Disc Morphology, Peripapillary Retinal Nerve Fiber Layer Thickness, and Macular Inner Retinal Layer Thickness in Glaucoma Diagnosis With Fourier-Domain Optical Coherence Tomography

      Diagnostic Power of Optic Disc Morphology, Peripapillary Retinal Nerve Fiber Layer Thickness, and Macular Inner Retinal Layer Thickness in Glaucoma Diagnosis With Fourier-Domain Optical Coherence Tomography
      ...The optic disc morphology, P-RNFL, and M-IRL were assessed by the Fourier-domain OCT (RTVue OCT, Model RT100, Optovue, Fremont, CA). A linear discriminant function was generated by stepwise linear discriminant analysis o...
      Read Full Article
    7. Measurement of central corneal thickness by high-resolution Scheimpflug imaging, Fourier-domain optical coherence tomography and ultrasound pachymetry

      Measurement of central corneal thickness by high-resolution Scheimpflug imaging, Fourier-domain optical coherence tomography and ultrasound pachymetry
      Purpose: To compare the repeatability and reproducibility of central corneal thickness (CCT) measurements by high-resolution (HR) rotating Scheimpflug imaging and Fourier-domain optical coherence tomography (FD-OCT). CCT measurements were compared to those determined by ultrasound pachymetry (UP).Methods: In 35 healthy eyes, intra-observer repeatability for HR Scheimpflug (Pentacam) and FD-OCT (RTVue) systems was determined in consecutive images taken by an observer in the shortest time possible. Imaging was repeated again by ...
      Read Full Article
    8. Optical Coherence Tomography Imaging for Diabetic Retinopathy and Macular Edema

      Optical Coherence Tomography Imaging for Diabetic Retinopathy and Macular Edema
      Abstract  Optical coherence tomography (OCT) is a noninvasive imaging modality that uses low-coherent interferometry to visualize an optical cross-section of biological tissues. Over the past two decades, the ability to perform OCT imaging of the neural retina has afforded clinicians and researchers a highly reproducible method of diagnosing and following diabetic macular edema (DME) that compares favorably to other methods of DME assessment such as clinical examination and fundus photography ...
      Read Full Article
    9. Macular Thickness Interoperator and Intraoperator Reproducibility in Healthy Eyes Using 7 Optical Coherence Tomography Instruments

      Macular Thickness Interoperator and Intraoperator Reproducibility in Healthy Eyes Using 7 Optical Coherence Tomography Instruments
      Purpose: To evaluate macular thickness measurement reproducibility using 6 new spectral-domain (SD) optical coherence tomography (OCT) devices and 1 time-domain OCT deviceDesign: Prospective, observational study.Methods: Setting: Clinical practice. Study Population: Macular thickness was assessed in 18 randomly chosen consecutive eyes of 18 healthy volunteers by 2 masked operators using 6 SD OCT devices and 1 time-domain OCT device. Main Outcome Measures: Intraoperator and interoperator reproducibility of OCT-measured central macular ...
      Read Full Article
    10. Comparison of retinal nerve fibre layer thickness measurements calculated by the optic nerve head map (NHM4) and RNFL3.45 modes of spectral-domain optical coherence tomography (RTVue-100)

      Comparison of retinal nerve fibre layer thickness measurements calculated by the optic nerve head map (NHM4) and RNFL3.45 modes of spectral-domain optical coherence tomography (RTVue-100)
      Aim To evaluate and compare retinal nerve fibre layer (RNFL) thickness measured by direct scanning (RNFL3.45 mode) and re-sampling from datasets (NHM4 mode) of RTVue-100 optical coherence tomography (OCT). Methods Thirty-six healthy subjects and 76 subjects with glaucoma were imaged with Stratus OCT (fast RNFL mode, RNFL3) and RTVue-100 OCT (NHM4 (RNFL1) and RNFL3.45 (RNFL2) modes). Measurement reproducibility was assessed in NHM4 and RNFL3.45 modes of RTVue-100 ...
      Read Full Article
    11. Comparison of Different Spectral Domain Optical Coherence Tomography Scanning Areas for Glaucoma Diagnosis

      Comparison of Different Spectral Domain Optical Coherence Tomography Scanning Areas for Glaucoma Diagnosis
      Purpose To evaluate retinal nerve fiber layer (RNFL), optic nerve head (ONH), and macular thickness measurements for glaucoma detection using the RTVue spectral domain optical coherence tomograph. Design Diagnostic, case-control study. Participants One hundred forty eyes of 106 glaucoma patients and 74 eyes of 40 healthy subjects from the Diagnostic Innovations in Glaucoma Study (DIGS). Methods All patients underwent ocular imaging with the commercially available RTVue. Optic nerve head, RNFL ...
      Read Full Article
    12. 661-675 of 756 « 1 2 ... 42 43 44 45 46 47 48 ... 49 50 51 »
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. About Optovue

    Optovue

    Optovue, Inc., a privately-held medical device company founded in 2003 and based in Fremont, Calif., is dedicated to the development and commercialization of high-speed optical coherence technology used to facilitate the diagnosis and management of eye diseases, many of which may lead to permanent blindness. For more information, visit www.optovue.com.

  3. Quotes about Optovue

    1. Our customers around the world provided a 19% revenue increase for 2009 over 2008...We have continuing strong support by representatives and distributor's world-wide, and all regions including the US are up significantly from 2008. The first fiscal quarter of 2010 demonstrated still another significant increase over 2009 numbers. The trend is clearly demonstrating that the clinical package offered by Optovue products is still highly desirable when faced with a number of product options.
      Gordon Wong in Optovue Announces 19% 2009 Revenue Increase Over 2008
    2. Gaining market share in the home country where Optovue manufactures is always satisfying...“Gaining market share in the home country where Optovue manufactures is always satisfying...The mission in 2012 is to continue our market growth world-wide utilizing our new TCP (Total Cornea Power) and V TRAC (Eye Tracking) options; as well as expand our iWellness programs.
      In Optovue Announces US sales orders for advanced OCT up 32% over previous year
    3. Haag-Streit is happy to partner with Optovue for its leadership in OCT technology and outstanding customer service. Our bundled technologies will create an advanced package that will provide a superior diagnostic tool to the ophthalmic industry.
      In Haag-Streit USA and Optovue Team Up to Introduce Octopus/Optovue Bundle