1. New York Eye and Ear Infirmary

    0 Comments Leave a Comment

    121-135 of 140 « 1 2 3 4 5 6 7 8 9 10 »
    1. Mentioned In 140 Articles

    2. The Use of Postoperative Slit-Lamp Optical Coherence Tomography to Predict Primary Failure in Descemet Stripping Automated Endothelial Keratoplasty

      Purpose: To determine if central donor lenticle thickness as measured by slit-lamp optical coherence tomography (SL OCT; Heidelberg Engineering, Heidelberg, Germany) is predictive of primary donor failure in patients undergoing Descemet stripping automated endothelial keratoplasty (DSAEK).Design: Retrospective cross-sectional study.Methods: Eighty-four patients who underwent DSAEK surgery by 2 surgeons (D.C.R. and J.A.S.) were enrolled. At each postoperative visit (postoperative day 1, week 1, month 1 ...
      Read Full Article
    3. Enhanced Depth Imaging Optical Coherence Tomography of Retinal Pigment Epithelial Detachment in Age-related Macular Degeneration

      Purpose: To describe the internal structure of pigment epithelial detachments (PEDs) seen in eyes with age-related macular degeneration (AMD) as imaged with enhanced depth imaging (EDI) spectral-domain optical coherence tomography (OCT).Design: Retrospective observational case series.Methods: The images were obtained by positioning a spectral-domain OCT device close enough to the eye to obtain an inverted image and 7 sections, each comprised of 100 averaged scans, were obtained within a ...
      Read Full Article
    4. Correlation between Retina Blood Flow Velocity Assessed by Retinal Function Imager and Retina Thickness Estimated by Scanning Laser Ophthalmoscopy/Optical Coherence Tomography

      Purpose: The purpose of this study was to evaluate the correlation between the retinal blood flow (RBF) assessed by the retinal functional imager (RFI) and central macular thickness/volume assessed by a spectral scanning laser ophthalmoscopy/optical coherence tomography (SLO-OCT) system. Methods: Seventeen eyes of 14 consecutive patients with various ocular diseases were examined. Retinal blood circulation characteristics were measured using the RFI. Retinal thickness/volume parameters were obtained by ...
      Read Full Article
    5. Anterior Segment Imaging: Optical Coherence Tomography Versus Ultrasound Biomicroscopy

      BACKGROUND AND OBJECTIVE To determine the clinical indications of anterior segment optical coherence tomography (AS-OCT) and ultrasound biomicroscopy in anterior segment imaging. PATIENTS AND METHODS Eighty patients were evaluated using AS-OCT and ultrasound biomicroscopy. RESULTS AS-OCT was ideal for detailed imaging of structures from...
      Read Full Article
    6. Imaging Vitreo-Macular Interface Abnormalities In The Coronal Plane By Simultaneous Combined Scanning Laser And Optical Coherence Tomography

      Purpose: To describe vitreo-retinal imaging of eyes with vitreo-macular abnormalities using high-resolution coronal-plane optical coherence tomography (OCT) scanning combined with simultaneous scanning laser ophthalmoscope (SLO) imaging. Methods: A SLO-OCT (OTI, Canada) was used to scan patients with vitreo-macular interface abnormalities including epiretinal membranes, macular hole, incomplete posterior vitreous detachment, vitreo-macular traction syndromes and diabetic and cystoid macular edema. The longitudinal –B scan images and the transverse –C scan images in ...
      Read Full Article
    7. Blood Vessel Contributions to Retinal Nerve Fiber Layer Thickness Profiles Measured With Optical Coherence Tomography.

      Purpose: To understand better the influence of retinal blood vessels (BVs) on the interindividual variation in the retinal nerve fiber layer (RNFL) thickness measured with optical coherence tomography (OCT). Subjects and Methods: RNFL thickness profiles were measured by OCT in 16 control individuals and 16 patients. The patients had advanced glaucoma defined by abnormal disc appearance, abnormal visual fields, and a mean visual field deviation worse than -10 dB. Results ...
      Read Full Article
    8. Intra-observer and Inter-observer Reliability and Reproducibility of Slit-Lamp–Adapted Optical Coherence Tomography for Evaluation of Anterior Chamber Depth and Central Corneal Thickness

      ...ttan Eye, Ear, and Throat Hospital (JRZ, JML), New York; Einhorn Clinical Research Center (SD, SNA, RR, JML), New York Eye and Ear Infirmary, New York; and New York Medical College (RR), Valhalla, New York. Accepted for ...
      Read Full Article
    9. An Analysis of Normal Variations in Retinal Nerve Fiber Layer Thickness Profiles Measured With Optical Coherence Tomography.

      Purpose: To assess the normal variations in retinal nerve fiber layer (RNFL) thickness measured with optical coherence tomography (OCT). Subjects and Methods: Both eyes of 48 individuals (age 56.4+/-9.5 y) with normal vision and refractive errors between +/-6.0 D were tested with the fast RNFL scan protocol of the OCT3 (Zeiss Meditech). Their 256-point RNFL profiles were exported for analysis. The location and peak amplitude of ...
      Read Full Article
    10. Macular Holes and Macular Pucker: The Role of Vitreoschsis as Imaged By Optical Coherence Tomography/Scanning Laser Ophthalmoscopy

      Macular Holes and Macular Pucker: The Role of  Vitreoschsis as Imaged By Optical Coherence Tomography/Scanning Laser Ophthalmoscopy
      ...hool of Medicine at the University of Southern California, Los Angeles (Drs Sebag, Gupta, and Sadun); and the New York Eye and Ear Infirmary, New York, New York (Drs Garcia and Rosen). *Presenter. Bold type indicates AOS...
      Read Full Article
    11. Intra-observer and Inter-observer Reliability and Reproducibility of Slit-Lamp–Adapted Optical Coherence Tomography for Evaluation of Anterior Chamber Depth and Central Corneal Thickness

      BACKGROUND AND OBJECTIVE To evaluate the intra-observer and inter-observer reproducibility of anterior chamber depth (ACD) and central corneal thickness (CCT) measurements taken by slit-lamp–adapted optical coherence tomography (SL-OCT) and to evaluate concordance of CCT and ACD values obtained by SL-OCT with gold standard devices. PATIENTS AND METHODS Three images of each eye were taken by two different operators using SL-OCT. ACD and CCT values obtained by each operator were ...
      Read Full Article
    12. 121-135 of 140 « 1 2 3 4 5 6 7 8 9 10 »
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. About New York Eye and Ear Infirmary

    New York Eye and Ear Infirmary

    New York Eye and Ear Infirmary is a voluntary, not-for-profit specialty hospital providing comprehensive outpatient and state-of-the-art medical/surgical care in the disciplines of Ophthalmology, Otolaryngology, Head & Neck Surgery, and Plastic & Reconstructive Surgery.  OCT Clinical Database at The New York Eye and Ear Infirmary.   The New York Eye and Ear Infirmary, Ocular Imaging Center, Optical Coherence Tomography (OCT) Clinical Database.