1. Kyoko Ohno-Matsui

    0 Comments Leave a Comment

    1-15 of 18 1 2 »
    1. Mentioned In 18 Articles

    2. Swept-source optical coherence tomographic findings in eyes with metastatic choroidal tumor

      Swept-source optical coherence tomographic findings in eyes with metastatic choroidal tumor
      Purpose To report the swept-source optical coherence tomographic (OCT) findings in two eyes with choroidal metastases. Observations Two patients with choroidal metastasis were studied. The metastasis was from a breast cancer in Case 1 and from a lung cancer in Case 2. In Case 1, swept-source OCT showed a highly reflective solid tumor with low optical reflective tissues that had replaced the choroidal tissue. Swept-source OCT was able to image ...
      Read Full Article
    3. Posterior Staphylomas in Pathologic Myopia Imaged by Widefield Optical Coherence Tomography

      Posterior Staphylomas in Pathologic Myopia Imaged by Widefield Optical Coherence Tomography
      Purpose : To examine posterior staphylomas by widefield optical coherence tomography (WF-OCT) and three-dimensional magnetic resonance imaging (3D-MRI). Methods : Highly myopic patients (myopic refractive error 8.0 diopters or axial length 26.5 mm) who had previously undergone orbital 3D-MRI were examined by WF-OCT. Results : The study included 100 eyes of 57 patients with a mean age of 67.9 10.7 years (range, 4485 years) and mean axial length of ...
      Read Full Article
    4. Optical Coherence Tomographic Imaging of Posterior Episclera and Tenon's Capsule

      Optical Coherence Tomographic Imaging of Posterior Episclera and Tenon's Capsule
      Purpose : To investigate structural features of the posterior episclera and Tenon's capsule in patients with high myopia. Methods : This hospital-based observational study included highly myopic eyes (myopic refractive error 8 diopters or axial length 26.5 mm) in which the posterior sclera in its full thickness could be visualized on swept-source optical coherence tomography (OCT) images in all 12 radial scans centered on the fovea. We assessed the posterior ...
      Read Full Article
    5. PERIPAPILLARY ARTERIAL RING OF ZINN-HALLER IN HIGHLY MYOPIC EYES AS DETECTED BY OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY

      PERIPAPILLARY ARTERIAL RING OF ZINN-HALLER IN HIGHLY MYOPIC EYES AS DETECTED BY OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY
      Purpose: To visualize the arterial circle of Zinn-Haller (ZHAC) in highly myopic patients by using OCT-A. Methods: Two hundred and fifty-three eyes of 146 consecutive patients with axial length =26.5 mm who underwent OCT-A centered onto the optic disk were studied. Results: Arterial circle of Zinn-Haller was detectable on OCT-A images within the area of the parapapillary myopic conus in 26 (10%) of 253 eyes. The ZHAC was annular ...
      Read Full Article
    6. Characteristics of Peripapillary Staphylomas Associated with High Myopia Determined by Swept-source Optical Coherence Tomography

      Characteristics of Peripapillary Staphylomas Associated with High Myopia Determined by Swept-source Optical Coherence Tomography
      Purpose To analyze the morphological features of peripapillary staphylomas associated with high myopia by swept-source optical coherence tomography (OCT). Design Validity analysis. Methods Highly myopic patients (refractive error 8.0 diopters or axial length 26.5 mm) with a peripapillary staphyloma who had undergone swept-source OCT were studied. The non-highly myopic fellow eyes in patients with unilateral high myopia were also studied. The presence of a peripapillary staphyloma was determined ...
      Read Full Article
    7. Influence of Clinical Factors and Magnification Correction on Normal Thickness Profiles of Macular Retinal Layers Using Optical Coherence Tomography

      Influence of Clinical Factors and Magnification Correction on Normal Thickness Profiles of Macular Retinal Layers Using Optical Coherence Tomography
      Purpose To identify the factors which significantly contribute to the thickness variabilities in macular retinal layers measured by optical coherence tomography with or without magnification correction of analytical areas in normal subjects. Methods The thickness of retinal layers {retinal nerve fiber layer (RNFL), ganglion cell layer plus inner plexiform layer (GCLIPL), RNFL plus GCLIPL (ganglion cell complex, GCC), total retina, total retina minus GCC (outer retina)} were measured by macular ...
      Read Full Article
    8. Macular Bruch’s Membrane Holes in Choroidal Neovascularization-Related Myopic Macular Atrophy by Swept-Source Optical Coherence Tomography

      Macular Bruch’s Membrane Holes in Choroidal Neovascularization-Related Myopic Macular Atrophy by Swept-Source Optical Coherence Tomography
      Purpose To determine frequency and associations of macular Bruchs membrane defects in the region of macular atrophy developing after the onset of myopic choroidal neovascularization (CNV). Design Retrospective observational case series. Methods The study included all patients who were consecutively examined for high myopia (axial length 26.5mm) and CNV-related macular atrophy in the study period from June to July 2015. The patients underwent a comprehensive ophthalmologic examination including swept-source ...
      Read Full Article
    9. Macular Bruch Membrane Holes in Choroidal Neovascularization–Related Myopic Macular Atrophy by Swept-Source Optical Coherence Tomography

      Macular Bruch Membrane Holes in Choroidal Neovascularization–Related Myopic Macular Atrophy by Swept-Source Optical Coherence Tomography
      Purpose To determine frequency and associations of macular Bruch membrane defects in the region of macular atrophy developing after the onset of myopic choroidal neovascularization (CNV). Design Retrospective observational case series. Methods The study included all patients who were consecutively examined for high myopia (axial length 26.5mm) and CNV-related macular atrophy in the study period from June to July 2015. The patients underwent a comprehensive ophthalmologic examination including swept-source ...
      Read Full Article
    10. Spectral-domain optical coherence tomography findings in pediatric tilted disc syndrome

      Spectral-domain optical coherence tomography findings in pediatric tilted disc syndrome
      Purpose To report a novel spectral-domain optical coherence tomography (SD-OCT) finding in children affected by tilted disc syndrome (TDS), and to correlate it with early visual field defects. Methods Patients between 5 and 17 years old with TDS were enrolled in this study. The diagnosis of TDS was made by stereoscopic fundus photography, when the upper edge of the optic disc protruded anteriorly relative to its lower edge. All eyes ...
      Read Full Article
    11. Evaluation of congenital optic disc pits and optic disc colobomas by swept-source optical coherence tomography

      Evaluation of congenital optic disc pits and optic disc colobomas by swept-source optical coherence tomography
      Purpose:To investigate the structural abnormalities of optic disc pits and colobomas by swept-source optical coherence tomography (OCT). Methods: Sixteen eyes with congenital optic disc pits, and 7 eyes with optic disc colobomas were studied. Papillary and peripapillary areas were examined with swept-source OCT. The entire course of the pit or cavity and the spatial relationship between pits and retrobulbar subarachnoid space (SAS) were examined. Results: OCT images showed the ...
      Read Full Article
    12. Analyses of shape of eyes and structure of optic nerves in eyes with tilted disc syndrome by swept-source optical coherence tomography and three-dimensional magnetic resonance imaging

      Analyses of shape of eyes and structure of optic nerves in eyes with tilted disc syndrome by swept-source optical coherence tomography and three-dimensional magnetic resonance imaging
      Purpose To evaluate the deeper structures of the optic nerve and to analyze the shape of eyes with tilted disc syndrome (TDS) by swept-source optical coherence tomography (OCT) and three-dimensional magnetic resonance imaging (3D MRI). Methods The medical records of 54 eyes of 36 patients with TDS were reviewed. The patients with TDS and high myopia were analyzed separately from those without high myopia. All the eyes were examined with ...
      Read Full Article
    13. Detection of Zinn-Haller Arterial Ring in Highly Myopic Eyes by Simultaneous Indocyanine Green Angiography and Optical Coherence Tomography

      Detection of Zinn-Haller Arterial Ring in Highly Myopic Eyes by Simultaneous Indocyanine Green Angiography and Optical Coherence Tomography
      ...Optical Coherence Tomography * Kyoko Ohno-Matsui Affiliations + Corresponding Author Information Inquiries to Kyoko Ohno-Matsui, Dept. of Ophthalmology and Visual Science, Tokyo Medical and Dental University, 1-5-45 Yush...
      Read Full Article
    14. Observations of vascular structures within and posterior to sclera in eyes with pathologic myopia by swept-source optical coherence tomography

      Observations of vascular structures within and posterior to sclera in eyes with pathologic myopia by swept-source optical coherence tomography
      Purpose. To examine the intrascleral and retrobular blood vessels in highly myopic eyes by swept-source optical coherence tomography (swept-source OCT). Methods. Six hundred and sixty-two eyes of 357 patients with pathologic myopia were studied. Radial scans along 12 meridians of 12 mm scan length centered on the fovea were made. Indocyanine green angiography (ICGA) was performed to identify the vessels observed by swept-source OCT. Results. Intrascleral and retrobulbar blood vessels ...
      Read Full Article
    15. Evaluation of Peripapillary Intrachoroidal Cavitation With Swept Source and Enhanced Depth Imaging Optical Coherence Tomography

      Evaluation of Peripapillary Intrachoroidal Cavitation With Swept Source and Enhanced Depth Imaging Optical Coherence Tomography
      Purpose: To investigate the anatomic characteristics of peripapillary intrachoroidal cavitation using optical coherence tomography methodologies that are capable of deeper tissue penetration and consider pathophysiologic mechanisms of disease on the basis of the derived imaging information. Methods: Consecutive eyes with peripapillary intrachoroidal cavitation were imaged with swept source optical coherence tomography with a 1-mm light source and in one eye with enhanced depth imaging spectral domain optical coherence tomography and ...
      Read Full Article
    16. 1-15 of 18 1 2 »
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. About Kyoko Ohno-Matsui

    Kyoko Ohno-Matsui is from the Department of Ophthalmology and Visual Science at the Tokyo Medical and Dental University.