1. K. U. Leuven

    0 Comments Leave a Comment

    1-15 of 52 1 2 3 4 »
    1. Mentioned In 52 Articles

    2. In-stent fractional flow reserve variations and related optical coherence tomography findings: the FFR–OCT co-registration study

      In-stent fractional flow reserve variations and related optical coherence tomography findings: the FFR–OCT co-registration study
      We sought to assess in-stent variations in fractional flow reserve (FFR) in patients with previous percutaneous coronary intervention (PCI) and to associate any drop in FFR with findings by optical coherence tomography (OCT) imaging. Suboptimal post-PCI FFR values were previously associated with poor outcomes. It is not known to which extent in-stent pressure loss contributes to reduced FFR. In this single-arm observational study, 26 patients who previously underwent PCI with ...
      Read Full Article
    3. EuOptical coherence tomography findings: insights from the “randomised multicentre trial investigating angiographic outcomes of hybrid sirolimus-eluting stents with biodegradable polymer compared with everolimus-eluting stents with durable polymer in chro

      EuOptical coherence tomography findings: insights from the “randomised multicentre trial investigating angiographic outcomes of hybrid sirolimus-eluting stents with biodegradable polymer compared with everolimus-eluting stents with durable polymer in chro
      Aims: The PRISON IV trial investigated the next-generation sirolimus-eluting stent (SES) with ultra-thin struts and biodegradable polymer against the second-generation everolimus-eluting stent (EES) with thin struts and durable polymer in patients with successfully recanalised chronic total occlusions (CTO). In this study, we examined the secondary optical coherence tomography endpoints. Methods and results: The main PRISON IV trial randomised 330 patients to either SES or EES. At nine months, 281 (85 ...
      Read Full Article
    4. Optical Coherence Tomography Findings in Patients with Coronary Stent Thrombosis: A Report of the PREvention of Late Stent Thrombosis by an Interdisciplinary Global European Effort (PRESTIGE) Consortium

      Optical Coherence Tomography Findings in Patients with Coronary Stent Thrombosis: A Report of the PREvention of Late Stent Thrombosis by an Interdisciplinary Global European Effort (PRESTIGE) Consortium
      Background Stent thrombosis (ST) is a serious complication following coronary stenting. Intravascular optical coherence tomography (OCT) may provide insights into mechanistic processes leading to ST. We performed a prospective, multicenter study to evaluate OCT findings in patients with ST. Methods Consecutive patients presenting with ST were prospectively enrolled in a registry using a centralized telephone registration system. After angiographic confirmation of ST, OCT imaging of the culprit vessel was performed ...
      Read Full Article
    5. Optical coherence tomography findings: insights from the “randomised multicentre trial investigating angiographic outcomes of hybrid sirolimus-eluting stents with biodegradable polymer compared with everolimus-eluting stents with durable polymer in chroni

      Optical coherence tomography findings: insights from the “randomised multicentre trial investigating angiographic outcomes of hybrid sirolimus-eluting stents with biodegradable polymer compared with everolimus-eluting stents with durable polymer in chroni
      Aims: The PRISON IV trial investigated the next-generation sirolimus-eluting stent (SES) with ultra-thin struts and biodegradable polymer against the second-generation everolimus-eluting stent (EES) with thin struts and durable polymer in patients with successfully recanalised chronic total occlusions (CTO). In this study, we examined the secondary optical coherence tomography endpoints. Methods and results: The main PRISON IV trial randomised 330 patients to either SES or EES. At nine months, 281 (85 ...
      Read Full Article
    6. Optical coherence tomography findings: insights from the “randomised multicentre trial investigating angiographic outcomes of hybrid sirolimus-eluting stents with biodegradable polymer compared with everolimus-eluting stents with durable polymer in chroni

      Optical coherence tomography findings: insights from the “randomised multicentre trial investigating angiographic outcomes of hybrid sirolimus-eluting stents with biodegradable polymer compared with everolimus-eluting stents with durable polymer in chroni
      Aims: The PRISON IV trial investigated the next-generation sirolimus-eluting stent (SES) with ultra-thin struts and biodegradable polymer against the second-generation everolimus-eluting stent (EES) with thin struts and durable polymer in patients with successfully recanalised chronic total occlusions (CTO). In this study, we examined the secondary optical coherence tomography endpoints. Methods and results: The main PRISON IV trial randomised 330 patients to either SES or EES. At nine months, 281 (85 ...
      Read Full Article
    7. Intraoperative margin assessment of human breast tissue in optical coherence tomography images using deep neural networks

      Intraoperative margin assessment of human breast tissue in optical coherence tomography images using deep neural networks
      Objective: In this work, we perform margin assessment of human breast tissue from optical coherence tomography (OCT) images using deep neural networks (DNNs). This work simulates an intraoperative setting for breast cancer lumpectomy. Methods: To train the DNNs, we use both the state-of-the-art methods (Weight Decay and DropOut) and a newly introduced regularization method based on function norms. Commonly used methods can fail when only a small database is available ...
      Read Full Article
    8. Anatomical and functional assessment of Tryton bifurcation stent before and after final kissing balloon dilatation: Evaluations by three-dimensional coronary angiography, optical coherence tomography imaging and fractional flow reserve

      Anatomical and functional assessment of Tryton bifurcation stent before and after final kissing balloon dilatation: Evaluations by three-dimensional coronary angiography, optical coherence tomography imaging and fractional flow reserve
      Objectives To assess the anatomical and functional impact of final kissing balloon inflation (FKBI) after implantation of a dedicated bifurcation stent system. Background Current evidence suggests clinical benefit of FKBI in patients undergoing bifurcation dilatation using the Tryton side branch stent (Tryton-SBS). We hypothesized that FKBI improves anatomical reconstruction and functional results of bifurcation treated by Tryton-SBS. Methods An unselected group of patients with complex bifurcation coronary lesions undergoing percutaneous ...
      Read Full Article
    9. Complex bifurcation lesions: Randomized comparison of a fully bioresorbable modified t stenting strategy versus bifurcation reconstruction with a dedicated self-expanding stent in combination with bioresorbable scaffolds, an OCT study: Rationale and desig

      Complex bifurcation lesions: Randomized comparison of a fully bioresorbable modified t stenting strategy versus bifurcation reconstruction with a dedicated self-expanding stent in combination with bioresorbable scaffolds, an OCT study: Rationale and desig
      Objective There is an ongoing controversy regarding the efficacy and safety of different percutaneous stenting techniques for coronary bifurcation lesions needing 1 stent. The promise of safe vessel restoration with bioresorbable scaffolds (BRS) may not be transferable to complex double BRS bifurcation techniques, and permanent metallic scaffolding of the bifurcation core may be needed. We identified modified-T stenting as the most promising fully bioresorbable 2-stent strategy in a preclinical setting ...
      Read Full Article
    10. Optical coherence tomography-based assessment of bifurcation stenting using the Axxess™ Biolimus A9™-eluting stent system

      Optical coherence tomography-based assessment of bifurcation stenting using the Axxess™ Biolimus A9™-eluting stent system
      Bifurcation lesions are associated with increased procedural complications and worse long-term outcome. Multiple techniques are available, including the dedicated drug-eluting Axxess stent system (Biosensors International Ltd., Singapore, Singapore), providing complete bifurcation support without covering the carina. Low rates of restenosis in both main vessel (MV) and side branch (SB) have been demonstrated. High-resolution imaging techniques such as intravascular optical coherence tomography (IV-OCT) may help the positioning and implantation of the ...
      Read Full Article
    11. Feature Of The Week 10/18/2015: Characterising Kiwifruit (Actinidia sp.) Near Skin Cellular Structures using Optical Coherence Tomography

      Feature Of The Week 10/18/2015: Characterising Kiwifruit (Actinidia sp.) Near Skin Cellular Structures using Optical Coherence Tomography
      Pre-harvest growing conditions during the development of fruit have impacts on fruit quality at the time of harvest and during storage. These impacts may result in differences in the skin properties of the fruit and some sub-surface cellular structural changes, which have potential effects on postharvest fruit quality and storability. Optical coherence tomography (OCT) is a non-destructive imaging method that enables acquisition of three-dimensional (3D) images of sub-surface structures of ...
      Read Full Article
    12. Characterising kiwifruit (Actinidia sp.) near skin cellular structures using optical coherence tomography

      Characterising kiwifruit (Actinidia sp.) near skin cellular structures using optical coherence tomography
      Pre-harvest growing conditions during the development of fruit have impacts on fruit quality at the time of harvest and during storage. These impacts may result in differences in the skin properties of the fruit and some sub-surface cellular structural changes, which have potential effects on postharvest fruit quality and storability. Optical coherence tomography (OCT) is a non-destructive imaging method that enables acquisition of three-dimensional (3D) images of sub-surface structures of ...
      Read Full Article
    13. COmplex coronary Bifurcation lesions: RAndomized comparison of a strategy using a dedicated self-expanding biolimus-eluting stent versus a culotte strategy using everolimus-eluting stents: primary results of the COBRA trial

      COmplex coronary Bifurcation lesions: RAndomized comparison of a strategy using a dedicated self-expanding biolimus-eluting stent versus a culotte strategy using everolimus-eluting stents: primary results of the COBRA trial
      Aims: We aimed to compare healing responses with optical coherence tomography, and clinical and angiographic outcome after treatment of coronary bifurcation lesions with a dedicated stent versus aconventional culotte technique. Methods and results: Forty patients with true and complex coronary bifurcation lesions were randomly assigned to treatment with the Axxess bifurcation stent in the proximal main vessel (MV) and additional BioMatrix stents in the branches (Biosensors Europe SA, Morges, Switzerland ...
      Read Full Article
    14. OCT for bifurcation stenting: what have we learned?

      OCT for bifurcation stenting: what have we learned?
      Treatment of bifurcation lesions by percutaneous coronary intervention (PCI) shows major variation in complexity. Intravascular optical coherence tomography (OCT) provides high-resolution images of the pathoanatomy, thrombus, wires and stent positions during the procedure. This information may prove crucial in optimising PCI results and clinical outcomes after complex bifurcation treatment. Mounting evidence confirms the feasibility of OCT in bifurcations, and specific steps where OCT may be advantageous in guiding bifurcation PCI ...
      Read Full Article
    15. STACCATO (Assessment of Stent sTrut Apposition and Coverage in Coronary ArTeries with Optical coherence tomography in patients with STEMI, NSTEMI and stable/unstable angina undergoing everolimus vs. biolimus A9-eluting stent implantation): a randomised co

      STACCATO (Assessment of Stent sTrut Apposition and Coverage in Coronary ArTeries with Optical coherence tomography in patients with STEMI, NSTEMI and stable/unstable angina undergoing everolimus vs. biolimus A9-eluting stent implantation): a randomised co
      Aims: To compare tissue coverage in coronary lesions stented with durable fluoropolymer-coated everolimus-eluting stents (EES) vs. biodegradable polymer-coated biolimus A9-eluting stents (BES). Methods and results: Sixty-four patients (64 lesions) with de novo coronary artery lesions were randomised to percutaneous treatment with XIENCE EES (Abbott Vascular, Santa Clara, CA, USA) vs. BioMatrix BES (Biosensors, Morges, Switzerland). The primary endpoint was the percentage of uncovered struts, as assessed with OCT, at nine ...
      Read Full Article
    16. 1-15 of 52 1 2 3 4 »
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. About K. U. Leuven

    K. U. Leuven

    Catholic University of Leuven (Katholieke Universiteit Leuven ) is situated in the heart of Western Europe and has been a centre of learning for almost six centuries. Founded in 1425 by Pope Martin V, K. U.Leuven bears the double honour of being the oldest existent Catholic university in the world and the oldest university in the Low Countries.