1. K. Kirk Shung

    0 Comments Leave a Comment

    1-15 of 27 1 2 »
    1. Mentioned In 27 Articles

    2. Integrated ultrasound, OCT, PA and/or florescence imaging endoscope for diagnosing cancers in gastrointestinal, respiratory, and urogenital tracts

      Integrated ultrasound, OCT, PA and/or florescence imaging endoscope for diagnosing cancers in gastrointestinal, respiratory, and urogenital tracts
      A multimodality imaging system including ultrasound, optical coherence tomography (OCT), photoacoustic (PA) imaging, florescence imaging and endoscopic catheter for imaging inside the gastrointestinal tract with real-time automatic image co-registration capability, including: an ultrasound subsystem for imaging; an optical coherence tomography (OCT) subsystem for imaging, a PA microscopy or tomography subsystem for imaging and a florescence imaging subsystem for imaging. An invasive interventional imaging device is included with an instrumentality to ...
      Read Full Article
    3. Miniature probe for mapping mechanical properties of vascular lesions using acoustic radiation force optical coherence elastography

      Miniature probe for mapping mechanical properties of vascular lesions using acoustic radiation force optical coherence elastography
      Cardiovascular diseases are the leading cause of fatalities in the United States. Atherosclerotic plaques are one of the primary complications that can lead to strokes and heart attacks if left untreated. It is essential to diagnose the disease early and distinguish vulnerable plaques from harmless ones. Many methods focus on the structural or molecular properties of plaques. Mechanical properties have been shown to change drastically when abnormalities develop in arterial ...
      Read Full Article
    4. Acoustic Radiation Force Optical Coherence Elastography of Corneal Tissue

      Acoustic Radiation Force Optical Coherence Elastography of Corneal Tissue
      We report on a real-time acoustic radiation force optical coherence elastography (ARF-OCE) system to map the relative elasticity of corneal tissue. A modulated ARF is used as excitation to vibrate the cornea, while OCE serves as detection of tissue response. To show feasibility of detecting mechanical contrast using this method, we performed tissue-equivalent agarose phantom studies with inclusions of a different stiffness. We obtained 3-D elastograms of a healthy cornea ...
      Read Full Article
    5. Two Imaging Catheters Unite to Better Detect Dangerous Plaques in Arteries

      Two Imaging Catheters Unite to Better Detect Dangerous Plaques in Arteries
      Collaboration between two National Institute of Biomedical Imaging and Bioengineering (NIBIB)-funded labs has revealed a promising new method for identifying atherosclerotic plaques, the encased deposits in arteries that restrict blood flow and can lead to heart attack or stroke. The technique combines two different types of imaging, allowing for an unprecedented combination of depth and detail. The hybrid technology will provide doctors with a better diagnostic tool for identifying ...
      Read Full Article
    6. Ultrafast optical-ultrasonic system and miniaturized catheter for imaging and characterizing atherosclerotic plaques in vivo

      Ultrafast optical-ultrasonic system and miniaturized catheter for imaging and characterizing atherosclerotic plaques in vivo
      Atherosclerotic coronary artery disease (CAD) is the number one cause of death worldwide. The majority of CAD-induced deaths are due to the rupture of vulnerable plaques. Accurate assessment of plaques is crucial to optimize treatment and prevent death in patients with CAD. Current diagnostic techniques are often limited by either spatial resolution or penetration depth. Several studies have proved that the combined use of optical and ultrasonic imaging techniques increase ...
      Read Full Article
    7. Imaging and characterizing shear wave and shear modulus under orthogonal acoustic radiation force excitation using OCT Doppler variance method

      Imaging and characterizing shear wave and shear modulus under orthogonal acoustic radiation force excitation using OCT Doppler variance method
      We report on a novel acoustic radiation force orthogonal excitation optical coherence elastography (ARFOE-OCE) technique for imaging shear wave and quantifying shear modulus under orthogonal acoustic radiation force (ARF) excitation using the optical coherence tomography (OCT) Doppler variance method. The ARF perpendicular to the OCT beam is produced by a remote ultrasonic transducer. A shear wave induced by ARF excitation propagates parallel to the OCT beam. The OCT Doppler variance ...
      Read Full Article
    8. Integrated Ultrasound, OCT, PA AND/OR Florescence Imaging Endoscope For Diagnosing Cancers In Gastrointestinal, Respiratory, And Urogenital Tracts

      Integrated Ultrasound, OCT, PA AND/OR Florescence Imaging Endoscope For Diagnosing Cancers In Gastrointestinal, Respiratory, And Urogenital Tracts
      A multimodality imaging system including ultrasound, optical coherence tomography (OCT), photoacoustic (PA) imaging, florescence imaging and endoscopic catheter for imaging inside the gastrointestinal tract with real-time automatic image co-registration capability, including: an ultrasound subsystem for imaging; an optical coherence tomography (OCT) subsystem for imaging, a PA microscopy or tomography subsystem for imaging and a florescence imaging subsystem for imaging. An invasive interventional imaging device is included with an instrumentality to ...
      Read Full Article
    9. Trimodality imaging system and intravascular endoscopic probe: combined optical coherence tomography, fluorescence imaging and ultrasound imaging

      Trimodality imaging system and intravascular endoscopic probe: combined optical coherence tomography, fluorescence imaging and ultrasound imaging
      ...imultaneously. © 2014 Optical Society of America Shanshan Liang, Teng Ma, Joseph Jing, Xiang Li, Jiawen Li, K. Kirk Shung, Qifa Zhou, Jun Zhang, and Zhongping Chen, "Trimodality imaging system and intravascular endosco...
      Read Full Article
    10. Ultrasound guided optical coherence tomography, photoacoustic probe for biomedical imaging

      Ultrasound guided optical coherence tomography, photoacoustic probe for biomedical imaging
      An imaging probe for a biological sample includes an OCT probe and an ultrasound probe combined with the OCT probe in an integral probe package capable of providing by a single scanning operation images from the OCT probe and ultrasound probe to simultaneously provide integrated optical coherence tomography (OCT) and ultrasound imaging of the same biological sample. A method to provide high resolution imaging of biomedical tissue includes the steps ...
      Read Full Article
    11. Integrated IVUS-OCT for Real-Time Imaging of Coronary Atherosclerosis

      Integrated IVUS-OCT for Real-Time Imaging of Coronary Atherosclerosis
      Accurate assessment of atherosclerotic plaque characteristics and the subsequent tailoring of optimal therapy holds great promise for preventing acute coronary syndromes (ACS) and life-threatening sequelae 1 . Combined use of optical coherence tomography (OCT) and intravascular ultrasound (IVUS) was proposed as a potential method for accurate assessment of plaque characteristics and vulnerability ( 2 , ). However, significant challenges remain in trying to adapt an integrated OCT-IVUS system for clinical applications. We report here ...
      Read Full Article
    12. Feature Of The Week 11/24/13 : Miniature OCT/IVUS probe for automatically co-registered three-dimensional intracoronary imaging with real-time display

      Feature Of The Week 11/24/13 : Miniature OCT/IVUS probe for automatically co-registered three-dimensional intracoronary imaging with real-time display
      Combined use of intravascular ultrasound (IVUS) and optical coherence tomography (OCT) holds the potential of combining the strengths of both imaging modalities and improving the diagnostic accuracy of atherosclerotic plaque vulnerability. In this manuscript, we reported a co-registered intracoronary OCT-IVUS system and catheter with real-time imaging and polar-coordinate displaying capability, well-suited for clinical utilization in guiding interventional cardiologists. With an eventual goal of clinical use in humans, this novel catheter ...
      Read Full Article
    13. Miniature optical coherence tomography-ultrasound probe for automatically coregistered three-dimensional intracoronary imaging with real-time display

      Miniature optical coherence tomography-ultrasound probe for automatically coregistered three-dimensional intracoronary imaging with real-time display
      We have developed a novel miniature integrated optical coherence tomography (OCT)-intravascular ultrasound (IVUS) probe, with a 1.5-mm-long rigid part and 0.9-mm outer diameter, for real-time intracoronary imaging of atherosclerotic plaques and guiding of interventional procedures. By placing the OCT ball lens and IVUS transducer back-to-back at the same axial position, this probe can provide automatically coregistered, coaxial OCT-IVUS imaging. To demonstrate its real-time capability, three-dimensional OCT-IVUS imaging ...
      Read Full Article
    14. 1-15 of 27 1 2 »
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. About K. Kirk Shung

    K. Kirk Shung

    K. Kirk Shung professor of biomedical engineering at the University of Southern California.  Professor Shung currently conducts research primarily in the area of high frequency ultrasonic imaging and transducer development supported by an NIH National Resource grant on transducer technology. Its thrust is on developing high frequency ultrasonic transducers and arrays which with improved spatial resolution are and can be used for dermatological, ophthalmological and intravascular imaging and small animal imaging.