1. Jodhbir S. Mehta

    0 Comments Leave a Comment

    1-15 of 27 1 2 »
    1. Mentioned In 27 Articles

    2. Quantification of the Posterior Cornea Using Swept Source Optical Coherence Tomography

      Quantification of the Posterior Cornea Using Swept Source Optical Coherence Tomography
      Purpose : We define optical coherence tomography (OCT) measurement parameters of the corneal endothelium/Descemet's membrane (DM) complex and peripheral transition zone (TZ) and describe these measurements in an ethnically Chinese population. Methods : OCT images of the anterior segment and iridocorneal angle were obtained from 129 healthy Chinese subjects (129 eyes), aged 40 to 81 years. The scleral spur (SS) and Schwalbe's line (SL) were identified in each image ...
      Read Full Article
    3. Comparison of Optical Coherence Tomography Angiography to Indocyanine Green Angiography and Slit Lamp Photography for Corneal Vascularization in an Animal Model

      Comparison of Optical Coherence Tomography Angiography to Indocyanine Green Angiography and Slit Lamp Photography for Corneal Vascularization in an Animal Model
      Corneal neovascularization (CoNV) could be treated by novel anti-angiogenic therapies, though reliable and objective imaging tools to evaluate corneal vasculature and treatment efficacy is still lacking. Optical coherence tomography angiography (OCTA) currently designed as a retinal vascular imaging system has been recently adapted for anterior-segment and showed good potential for successful imaging of CoNV. However, further development requires an animal model where parameters can be studied more carefully with histological ...
      Read Full Article
    4. Novel application of In Vivo Micro-Optical Coherence Tomography to assess Cornea scarring in an Animal Model

      Novel application of In Vivo Micro-Optical Coherence Tomography to assess Cornea scarring in an Animal Model
      This pilot study uses a micro-optical coherence tomography (micro-OCT) system with ~1m axial resolution specifically to image the cornea and corneal scars in vivo . We used an established murine corneal scar model by irregular phototherapeutic keratectomy in ten C57BL/6 mice, with serial imaging using the micro-OCT and compared to anterior segment (AS-OCT) (RTvue, Optovue, Fremont, CA) before and after scar induction. Main outcome was agreement between the AS-OCT and ...
      Read Full Article
    5. Intraoperative Optical Coherence Tomography Vault Measurement in Posterior Chamber Phakic Intraocular Lens Implantation

      Intraoperative Optical Coherence Tomography Vault Measurement in Posterior Chamber Phakic Intraocular Lens Implantation
      PURPOSE: To describe the use of intraoperative optical coherence tomography (OCT) vault measurement in 5 cases of posterior chamber phakic intraocular lens (IOL) implantation. METHODS: This case series included 5 eyes in 3 consecutive patients undergoing phakic IOL implantation. RTVue OCT (Optovue, Inc., Fremont, CA) was used to obtain intraoperative vault measurements after pupil constriction. Visante OCT (Carl Zeiss Meditec, Jena, Germany) was used to obtain postoperative vault measurements. RESULTS ...
      Read Full Article
    6. Needle Depth and Big-Bubble Success in Deep Anterior Lamellar Keratoplasty: An Ex Vivo Microscope-Integrated OCT Study

      Needle Depth and Big-Bubble Success in Deep Anterior Lamellar Keratoplasty: An Ex Vivo Microscope-Integrated OCT Study
      Purpose: To examine big-bubble (BB) formation success rates in deep anterior lamellar keratoplasty (DALK) at various corneal depths using real-time guidance from swept-source, microscope-integrated optical coherence tomography (SS-MIOCT). Methods: The DALK procedure was performed ex vivo with 34 human donor corneoscleral buttons on pressurized artificial anterior chambers using the BB technique employed by Anwar and Teichmann. We inserted a needle under controlled ex vivo conditions to corneal depths ranging from ...
      Read Full Article
    7. Applications of Anterior Segment Optical Coherence Tomography in Cornea and Ocular Surface Diseases

      Applications of Anterior Segment Optical Coherence Tomography in Cornea and Ocular Surface Diseases
      Optical coherence tomography (OCT) is a noncontact technology that produces high-resolution cross-sectional images of ocular tissues. Anterior segment OCT (AS-OCT) enables the precise visualization of anterior segment structure; thus, it can be used in various corneal and ocular surface disorders. In this review, the authors will discuss the application of AS-OCT for diagnosis and management of various corneal and ocular surface disorders. Use of AS-OCT for anterior segment surgery and ...
      Read Full Article
    8. Enhancement of Corneal Visibility in Optical Coherence Tomography Images with Corneal Opacification

      Enhancement of Corneal Visibility in Optical Coherence Tomography Images with Corneal Opacification
      Purpose : To establish and to rank the performance of a corneal adaptive compensation (CAC) algorithm in enhancing corneal images with scars acquired from three commercially available anterior segment optical coherence tomography (ASOCT) devices. Methods : Horizontal B-scans of the cornea were acquired from 10 patients using three ASOCT devices (Spectralis, RTVue, and Cirrus). We compared ASOCT image quality (with and without CAC) by computing the intralayer contrast (a measure of shadow ...
      Read Full Article
    9. Evaluation of a Micro-Optical Coherence Tomography for the Corneal Endothelium in an Animal Model

      Evaluation of a Micro-Optical Coherence Tomography for the Corneal Endothelium in an Animal Model
      Recent developments in optical coherence tomography (OCT) systems for the cornea have limited resolution or acquisition speed. In this study we aim to evaluate the use of a micro-OCT (OCT ~1m axial resolution) compared to existing imaging modalities using animal models of corneal endothelial disease. We used established cryoinjury and bullous keratopathy models in Sprague Dawley rats comparing ex vivo OCT imaging in normal and diseased eyes to (1) histology ...
      Read Full Article
    10. Corneal graft evaluation based on optical coherence tomography image

      Corneal graft evaluation based on optical coherence tomography image
      An OCT image of an eye which has been subject to a DSAEK corneal transplant, in which a Descement's membrane in the cornea has been replaced by a graft, is processed to identify the outline of the graft. The process includes the steps of: computationally extracting the boundary of the cornea including the graft; computationally detecting the corners of the graft; computationally extracting points on the boundary between the ...
      Read Full Article
    11. Intraobserver repeatability and interobserver reproducibility of corneal measurements in normal eyes using an optical coherence tomography–Placido disk device

      Intraobserver repeatability and interobserver reproducibility of corneal measurements in normal eyes using an optical coherence tomography–Placido disk device
      ... , FRCS(Ed) , Hla Myint Htoon x Hla Myint Htoon Search for articles by this author , PhD , Jodhbir S. Mehta x Jodhbir S. Mehta Search for articles by this author Correspondence * Corresponding author: Jodhbir S. Meht...
      Read Full Article
    12. Use of Anterior Segment Optical Coherence Tomography to Predict Corneal Graft Rejection in Small Animal Models

      Use of Anterior Segment Optical Coherence Tomography to Predict Corneal Graft Rejection in Small Animal Models
      Purpose: To correlate the degree of anterior chamber (AC) inflammation and corneal thickness evaluated by anterior segment optical coherence tomography (ASOCT) with corneal graft rejection status and to explore the value of ASOCT in assisting the diagnosis or prediction of graft rejection using a rat penetrating keratoplasty (PK) model. Methods: A total of 40 PKs were performed using Fisher rats (allogeneic groups) and Lewis rats (syngeneic group) as donors and ...
      Read Full Article
    13. Intraoperative Anterior Segment Optical Coherence Tomography: A Novel Assessment Tool during Deep Anterior Lamellar Keratoplasty

      Intraoperative Anterior Segment Optical Coherence Tomography: A Novel Assessment Tool during Deep Anterior Lamellar Keratoplasty
      Purpose To describe the use of high-resolution anterior segment optical coherence tomography (AS-OCT) during deep anterior lamellar keratoplasty (DALK). Design Prospective case series. Methods We performed at the Singapore National Eye Centre sequential intraoperative AS-OCT scans using iVue 100-2 (Optovue, Fremont, CA) during different DALK techniques. Results In case 1 (corneal scarring) the OCT images helped guiding manual dissection, showed the depth of the needle track before air injection, and ...
      Read Full Article
    14. Comparison of Anterior Segment Optical Tomography Parameters Measured Using a Semi-Automatic Software to Standard Clinical Instruments

      Comparison of Anterior Segment Optical Tomography Parameters Measured Using a Semi-Automatic Software to Standard Clinical Instruments
      ...by Marcus Ang, Wesley Chong, Huiqi Huang, Wan Ting Tay, Tien Yin Wong, Ming-Guang He, Tin Aung, Jodhbir S. Mehta Objective To compare anterior segment parameters measured using a semi-automatic software (Zhongs...
      Read Full Article
    15. Reproducibility and age-related changes of ocular parametric measurements in rabbits

      Reproducibility and age-related changes of ocular parametric measurements in rabbits
      Background The rabbit is a common animal model for ophthalmic research, especially corneal research. Ocular structures grow rapidly during the early stages of life. It is unclear when the rabbit cornea becomes mature and stabilized. We investigated the changes of keratometry, refractive state and central corneal thickness (CCT) with age. In addition, we studied the intra- and inter-observer reproducibility of anterior chamber depth (ACD) and anterior chamber width (ACW) measurements ...
      Read Full Article
    16. Refractive lenticule extraction flap and stromal bed morphology assessment with anterior segment optical coherence tomography

      Refractive lenticule extraction flap and stromal bed morphology assessment with anterior segment optical coherence tomography
      ... FRCS(Gl), * Jodhbir S. Mehta, FRCS(Ed) Affiliations + Corresponding Author Information Corresponding author: Jodhbir S. Mehta, FRCS(Ed), Singapore National Eye Centre, 11 Third Hospital Avenue, 168751, Singapore. email ...
      Read Full Article
    17. 1-15 of 27 1 2 »
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. About Jodhbir S. Mehta

    Jodhbir S. Mehta

    Jodhbir S. Mehta is with the  Tissue Engineering and Stem Cell Group, Singapore Eye Research Institute, the Singapore National Eye Centre, Singapore, and the  Department of Clinical Sciences, Duke-NUS Graduate Medical School, Singapore.