1. Articles mentioning both Praevium Research and Harvard University

    1-6 of 6
    1. Feature Of The Week 10/08/2018: Clinical Utility of Ultrahigh-Speed Endoscopic Optical Coherence Tomography in Gastroenterology

      Feature Of The Week 10/08/2018: Clinical Utility of Ultrahigh-Speed Endoscopic Optical Coherence Tomography in Gastroenterology
      Barretts esophagus (BE) surveillance is limited by biopsy sampling error. Optical coherence tomography (OCT) enables microscopic resolution, high speed, volumetric imaging and is commercially available as volumetric laser endomicroscopy (VLE, NinePoint Medical). Studies investigated cross-sectional OCT dysplasia features, including a diagnostic algorithm (VLE-DA), however, many VLE studies used ex vivo specimens due to challenges in registering biopsy with OCT. We previously demonstrated ultrahigh-speed endoscopic OCT 10x faster than commercial instruments ...
      Read Full Article
    2. Cycloid scanning for wide field optical coherence tomography endomicroscopy and angiography in vivo

      Cycloid scanning for wide field optical coherence tomography endomicroscopy and angiography in vivo
      Devices that perform wide field-of-view (FOV) precision optical scanning are important for endoscopic assessment and diagnosis of luminal organ disease such as in gastroenterology. Optical scanning for in vivo endoscopic imaging has traditionally relied on one or more proximal mechanical actuators, limiting scan accuracy and imaging speed. There is a need for rapid and precise two-dimensional (2D) microscanning technologies to enable the translation of benchtop scanning microscopies to in vivo ...
      Read Full Article
    3. Endoscopic forward-viewing optical coherence tomography and angiography with MHz swept source

      Endoscopic forward-viewing optical coherence tomography and angiography with MHz swept source
      Endoscopic optical coherence tomography (OCT) instruments are mostly side viewing and rely on at least one proximal scan, thus limiting accuracy of volumetric imaging and en face visualization. Previous forward-viewing OCT devices had limited axial scan speeds. We report a forward-viewing fiber scanning 3D-OCT probe with 900 m field of view and 5 m transverse resolution, imaging at 1 MHz axial scan rate in the human gastrointestinal tract. The probe ...
      Read Full Article
    4. Circumferential optical coherence tomography angiography imaging of the swine esophagus using a micromotor balloon catheter

      Circumferential optical coherence tomography angiography imaging of the swine esophagus using a micromotor balloon catheter
      We demonstrate a micromotor balloon imaging catheter for ultrahigh speed endoscopic optical coherence tomography (OCT) which provides wide area, circumferential structural and angiographic imaging of the esophagus without contrast agents. Using a 1310 nm MEMS tunable wavelength swept VCSEL light source, the system has a 1.2 MHz A-scan rate and ~8.5 m axial resolution in tissue. The micromotor balloon catheter enables circumferential imaging of the esophagus at 240 ...
      Read Full Article
    5. Feature Of The Week 03/08/2015: Endoscopic Optical Coherence Angiography Enables Three Dimensional Visualization of Subsurface Microvasculature

      Feature Of The Week 03/08/2015: Endoscopic Optical Coherence Angiography Enables Three Dimensional Visualization of Subsurface Microvasculature
      Endoscopic imaging technologies such as confocal laser endomicroscopy (CLE) and narrowband imaging (NBI) have been used to investigate vascular changes as hallmarks of early cancer in the GI tract. However, the limited frame rate and field of view make CLE imaging sensitive to motion artifacts, whereas NBI has limited resolution and visualizes only the surface vascular pattern. Endoscopic optical coherence tomography (OCT) enables high speed volumetric imaging of subsurface features ...
      Read Full Article
    6. Ultrahigh speed endoscopic optical coherence tomography for gastroenterology

      Ultrahigh speed endoscopic optical coherence tomography for gastroenterology
      We describe an ultrahigh speed endoscopic swept source optical coherence tomography (OCT) system for clinical gastroenterology using a vertical-cavity surface-emitting laser (VCSEL) and micromotor imaging catheter. The system had a 600 kHz axial scan rate and 8 m axial resolution in tissue. Imaging was performed with a 3.2 mm diameter imaging catheter at 400 frames per second with a 12 m spot size. Three-dimensional OCT (3D-OCT) imaging was performed ...
      Read Full Article
    7. 1-6 of 6
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Organizations in the News

    1. (6 articles) Massachusetts Institute of Technology
    2. (1 articles) Brigham and Women’s Hospital
    3. (1 articles) Johns Hopkins University
  3. OCT Companies in the News

    1. (6 articles) Thorlabs
    2. (1 articles) NinePoint Medical