1. Articles mentioning both Joseph A. Izatt and Duke University

    25-48 of 213 « 1 2 3 4 5 6 7 8 9 »
    1. Four-dimensional microscope- integrated optical coherence tomography to enhance visualization in glaucoma surgeries

      Four-dimensional microscope- integrated optical coherence tomography to enhance visualization in glaucoma surgeries
      ..., USA 2 Department of Biomedical Engineering, Duke University, Durham, NC, USA 3 Department of Ophthalmology, Duke University School of Medicine; Department of Biomedical Engineering, Duke University, Durham, NC, USA Cor...
      Read Full Article
    2. Review of intraoperative optical coherence tomography: technology and applications [Invited]

      Review of intraoperative optical coherence tomography: technology and applications [Invited]
      During microsurgery, en face imaging of the surgical field through the operating microscope limits the surgeons depth perception and visualization of instruments and sub-surface anatomy. Surgical procedures outside microsurgery, such as breast tumor resections, may also benefit from visualization of the sub-surface tissue structures. The widespread clinical adoption of optical coherence tomography (OCT) in ophthalmology and its growing prominence in other fields, such as cancer imaging, has motivated the development ...
      Read Full Article
    3. Four-dimensional Microscope-Integrated Optical Coherence Tomography to Visualize Suture Depth in Strabismus Surgery

      Four-dimensional Microscope-Integrated Optical Coherence Tomography to Visualize Suture Depth in Strabismus Surgery
      The authors report the use of swept-source microscope-integrated optical coherence tomography (SS-MIOCT), capable of live four-dimensional (three-dimensional across time) intraoperative imaging, to directly visualize suture depth during lateral rectus resection. Key surgical steps visualized in this report included needle depth during partial and full-thickness muscle passes along with scleral passes.
      Read Full Article
    4. Wireless, Web-Based Interactive Control of Optical Coherence Tomography with Mobile Devices

      Wireless, Web-Based Interactive Control of Optical Coherence Tomography with Mobile Devices
      Purpose : Optical coherence tomography (OCT) is widely used in ophthalmology clinics and has potential for more general medical settings and remote diagnostics. In anticipation of remote applications, we developed wireless interactive control of an OCT system using mobile devices. Methods : A web-based user interface (WebUI) was developed to interact with a handheld OCT system. The WebUI consisted of key OCT displays and controls ported to a webpage using HTML and ...
      Read Full Article
    5. Enhanced visualization of peripheral retinal vasculature with wavefront sensorless adaptive optics optical coherence tomography angiography in diabetic patients

      Enhanced visualization of peripheral retinal vasculature with wavefront sensorless adaptive optics optical coherence tomography angiography in diabetic patients
      Optical coherence tomography angiography (OCTA) is a promising technique for non-invasive visualization of vessel networks in the human eye. We debut a system capable of acquiring wide field-of-view ( 70 70 ) OCT angiograms without mosaicking. Additionally, we report on enhancing the visualization of peripheral microvasculature using wavefront sensorless adaptive optics (WSAO). We employed a fast WSAO algorithm that enabled wavefront correction in 2 s 2s by iterating the mirror shape at ...
      Read Full Article
    6. Wide-field retinal optical coherence tomography with wavefront sensorless adaptive optics for enhanced imaging of targeted regions

      Wide-field retinal optical coherence tomography with wavefront sensorless adaptive optics for enhanced imaging of targeted regions
      The peripheral retina of the human eye offers a unique opportunity for assessment and monitoring of ocular diseases. We have developed a novel wide-field (70) optical coherence tomography system (WF-OCT) equipped with wavefront sensorless adaptive optics (WSAO) for enhancing the visualization of smaller (25) targeted regions in the peripheral retina. We iterated the WSAO algorithm at the speed of individual OCT B-scans (~20 ms) by using raw spectral interferograms to ...
      Read Full Article
    7. Needle Depth and Big-Bubble Success in Deep Anterior Lamellar Keratoplasty: An Ex Vivo Microscope-Integrated OCT Study

      Needle Depth and Big-Bubble Success in Deep Anterior Lamellar Keratoplasty: An Ex Vivo Microscope-Integrated OCT Study
      Purpose: To examine big-bubble (BB) formation success rates in deep anterior lamellar keratoplasty (DALK) at various corneal depths using real-time guidance from swept-source, microscope-integrated optical coherence tomography (SS-MIOCT). Methods: The DALK procedure was performed ex vivo with 34 human donor corneoscleral buttons on pressurized artificial anterior chambers using the BB technique employed by Anwar and Teichmann. We inserted a needle under controlled ex vivo conditions to corneal depths ranging from ...
      Read Full Article
    8. Live volumetric (4D) visualization and guidance of in vivo human ophthalmic surgery with intraoperative optical coherence tomography

      Live volumetric (4D) visualization and guidance of in vivo human ophthalmic surgery with intraoperative optical coherence tomography
      Minimally-invasive microsurgery has resulted in improved outcomes for patients. However, operating through a microscope limits depth perception and fixes the visual perspective, which result in a steep learning curve to achieve microsurgical proficiency. We introduce a surgical imaging system employing four-dimensional (live volumetric imaging through time) microscope-integrated optical coherence tomography (4D MIOCT) capable of imaging at up to 10 volumes per second to visualize human microsurgery. A custom stereoscopic heads-up ...
      Read Full Article
    9. Method for single illumination source combined optical coherence tomography and fluorescence imaging of fluorescently labeled ocular structures in transgenic mice

      Method for single illumination source combined optical coherence tomography and fluorescence imaging of fluorescently labeled ocular structures in transgenic mice
      In vivo imaging permits longitudinal study of ocular disease processes in the same animal over time. Two different in vivo optical imaging modalities optical coherence tomography (OCT) and fluorescence provide important structural and cellular data respectively about disease processes. In this Methods in Eye Research article, we describe and demonstrate the combination of these two modalities producing a truly simultaneous OCT and fluorescence imaging system for imaging of fluorescently labeled ...
      Read Full Article
    10. Length-adaptive graph search for automatic segmentation of pathological features in optical coherence tomography images

      Length-adaptive graph search for automatic segmentation of pathological features in optical coherence tomography images
      We introduce a metric in graph search and demonstrate its application for segmenting retinal optical coherence tomography (OCT) images of macular pathology. Our proposed adjusted mean arc length (AMAL) metric is an adaptation of the lowest mean arc length search technique for automated OCT segmentation. We compare this method to Dijkstras shortest path algorithm, which we utilized previously in our popular graph theory and dynamic programming segmentation technique. As an ...
      Read Full Article
    11. Spectral domain optical coherence tomography (SD-OCT) Imaging of the Vascular-Avascular junction in the nursery in infants with retinopathy of prematurity

      Spectral domain optical coherence tomography (SD-OCT) Imaging of the Vascular-Avascular junction in the nursery in infants with retinopathy of prematurity
      Since the publication of Foos, there has been little additional microanatomic data on the vascular-avascular junction in retinopathy of prematurity (ROP) in infants. We hypothesize that one could view retinal development across the vascular-avascular (V-AV) junction in infants with ROP using portable bedside SDOCT imaging and novel image analysis.
      Read Full Article
    12. Impact of Microscope-Integrated OCT on Ophthalmology Resident Performance of Anterior Segment Surgical Maneuvers in Model Eyes

      Impact of Microscope-Integrated OCT on Ophthalmology Resident Performance of Anterior Segment Surgical Maneuvers in Model Eyes
      Purpose : The integration of swept-source optical coherence tomography (SS-OCT) into the operating microscope enables real-time, tissue-level three-dimensional (3D) imaging to aid in ophthalmic microsurgery. In this prospective randomized controlled study, we evaluated the impact of SS microscope-integrated OCT (MI-OCT) on ophthalmology residents' performance of ophthalmic microsurgical maneuvers. Methods : Fourteen ophthalmology residents from a single institution were stratified by year of training and randomized to perform four anterior segment surgical maneuvers ...
      Read Full Article
    13. Posterior Eye Shape Measurement With Retinal OCT Compared to MRI

      Posterior Eye Shape Measurement With Retinal OCT Compared to MRI
      Purpose : Posterior eye shape assessment by magnetic resonance imaging (MRI) is used to study myopia. We tested the hypothesis that optical coherence tomography (OCT), as an alternative, could measure posterior eye shape similarly to MRI. Methods : Macular spectral-domain OCT and brain MRI images previously acquired as part of the Singapore Epidemiology of Eye Diseases study were analyzed. The right eye in the MRI and OCT images was automatically segmented. Optical ...
      Read Full Article
    14. Optical Coherence Tomography for Retinal Surgery: Perioperative Analysis to Real-Time Four-Dimensional Image-Guided Surgery

      Optical Coherence Tomography for Retinal Surgery: Perioperative Analysis to Real-Time Four-Dimensional Image-Guided Surgery
      Magnification of the surgical field using the operating microscope facilitated profound innovations in retinal surgery in the 1970s, such as pars plana vitrectomy. Although surgical instrumentation and illumination techniques are continually developing, the operating microscope for vitreoretinal procedures has remained essentially unchanged and currently limits the surgeon's depth perception and assessment of subtle microanatomy. Optical coherence tomography (OCT) has revolutionized clinical management of retinal pathology, and its introduction into ...
      Read Full Article
    15. Methods and computer program products for quantitative three-dimensional image correction and clinical parameter computation in optical coherence tomography

      Methods and computer program products for quantitative three-dimensional image correction and clinical parameter computation in optical coherence tomography
      Methods and computer program products for quantitative three-dimensional ("3D") image correction in optical coherence tomography. Using the methods and computer program products, index interface (refracting) surfaces from the raw optical coherence tomography ("OCT") dataset from an OCT system can be segmented. Normal vectors or partial derivatives of the curvature at a refracting surface can be calculated to obtain a refracted image voxel. A new position of each desired refracted image ...
      Read Full Article
    16. 25-48 of 213 « 1 2 3 4 5 6 7 8 9 »
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Organizations in the News

    1. (17 articles) National Institutes of Health
    2. (7 articles) Case Western Reserve University
    3. (6 articles) Vanderbilt University
    4. (6 articles) Cleveland Clinic
    5. (5 articles) FDA
    6. (5 articles) Medical University of Vienna
    7. (4 articles) Center for Ophthalmic Optics and Lasers
    8. (4 articles) University of Illinois at Urbana-Champaign
    9. (4 articles) University of Kent
    10. (4 articles) University of Southern California
    11. (4 articles) Harvard University
    12. (4 articles) National Eye Institute
  3. People in the News

    1. (69 articles) Cynthia A. Toth
    2. (53 articles) Sina Farsiu
    3. (43 articles) Anthony N. Kuo
    4. (31 articles) Oscar Carrasco-Zevallos
    5. (17 articles) Yuankai K. Tao
    6. (15 articles) Stephanie J. Chiu
    7. (11 articles) Eric L. Buckland
    8. (11 articles) Al-Hafeez Dhalla
    9. (9 articles) Melissa C. Skala
    10. (9 articles) Paul V. Hahn
    11. (9 articles) Mingtao Zhao
    12. (7 articles) Ramiro S. Maldonado
  4. OCT Companies in the News

    1. (21 articles) Bioptigen
    2. (3 articles) Carl Zeiss Meditec
    3. (3 articles) Axsun Technologies
    4. (3 articles) Thorlabs
    5. (3 articles) St. Jude Medical
    6. (2 articles) Cambridge Technology
    7. (2 articles) Oncoscope
    8. (2 articles) Santec
    9. (2 articles) Physical Sciences Incorporated
    10. (2 articles) Leica
    11. (2 articles) Heidelberg Engineering
    12. (1 articles) Tomophase Corporation