1. Articles mentioning both Dresden University of Technology and Edmund Koch

    1-24 of 106 1 2 3 4 5 »
    1. Endoscopic Optical Coherence Tomography for Evaluation of Success of Tympanoplasty

      Endoscopic Optical Coherence Tomography for Evaluation of Success of Tympanoplasty
      Objective: After tympanoplasty , it is often challenging to differentiate between different causes of a remaining air bone gap (ABG). Optical coherence tomography (OCT) offers a new approach for combined morphologic and functional measurements of the tympanic membrane and adjacent parts of the middle ear. Thus, it provides valuable diagnostic information in patients with a reduced sound transfer after middle ear surgery. Patient and intervention: A patient with history of tympanoplasty ...
      Read Full Article
    2. Evaluation of middle ear reconstruction by endoscopic Optical Coherence Tomography

      Evaluation of middle ear reconstruction by endoscopic Optical Coherence Tomography
      Introduction Endoscopic Optical Coherence Tomography (eOCT) allows high-resolution 3-dimensional imaging of the tympanic membrane and the adjacent areas of the middle ear. Doppler-OCT enables oscillation measurement. Thus, the postoperative outcome of tympanoplasty can be evaluated. Material and Methods 5 Patients were examined after tympanoplasty using eOCT. The system utilizes a near infrared laser with a central wavelength of 1300 nm and a working range of 8 mm. The thickness of ...
      Read Full Article
    3. Device and system for doppler optical coherence tomography (OCT) of the human middle ear

      Device and system for doppler optical coherence tomography (OCT) of the human middle ear
      A device for Doppler optical coherence tomography (Doppler OCT), preferably of the human middle ear, is proposed. The device has an endoscope unit for at least partial insertion into the auditory canal. A sound source, a sound receiver, and OCT optics are integrated in the endoscope unit.
      Read Full Article
    4. Correlation between Lesion Progression and Depolarization Assessed by Polarization-Sensitive Optical Coherence Tomography

      Correlation between Lesion Progression and Depolarization Assessed by Polarization-Sensitive Optical Coherence Tomography
      The detection of early stages of caries is still one of the major challenges in preservative dentistry. Since it is known from polarized light microscopy (PLM) that intrinsic enamel birefringence is affected by demineralization, polarization-sensitive optical coherence tomography (PSOCT) could facilitate the noninvasive detection and assessment of early carious lesions. The present study aims to correlate enamel lesion progression and depolarization measurements based on PSOCT in an artificial demineralization model ...
      Read Full Article
    5. Depth-resolved birefringence imaging of collagen fiber organization in the human oral mucosa in vivo

      Depth-resolved birefringence imaging of collagen fiber organization in the human oral mucosa in vivo
      Stromal collagen organization has been identified as a potential prognostic indicator in a variety of cancers and other diseases accompanied by fibrosis. Changes in the connective tissue are increasingly considered for grading dysplasia and progress of oral squamous cell carcinoma, investigated mainly ex vivo by histopathology. In this study, polarization-sensitive optical coherence tomography (PS-OCT) with local phase retardation imaging is used for the first time to visualize depth-resolved (i.e ...
      Read Full Article
    6. Quality Assessment of Tympanoplasty by Means of Endoscopic Optical Coherence Tomography

      Quality Assessment of Tympanoplasty by Means of Endoscopic Optical Coherence Tomography
      Introduction: The endoscopic optical coherence tomography (eOCT) allows the direct, contactless representation and evaluation of the morphology and oscillation behaviour of the tympanic membrane and adjoining tympanic cavity content. After further development of the measuring technology, the eOCT will be able to be used in vivo for the assessment of tympanoplasty results. Materials and Methods: The eOCT was applied to 10 patients after a tympanoplasty with an intact ossicular chain ...
      Read Full Article
    7. Endoscopic Optical Coherence Tomography in Diagnostics of Otosclerosis

      Endoscopic Optical Coherence Tomography in Diagnostics of Otosclerosis
      Introduction: Endoscopic Optical Coherence Tomography (eOCT) enables both high-resolution contact-free 3D-imaging of the tympanic membrane and spatial and frequency-resolved oscillation measurement via Doppler-OCT. Thus it is possible to detect causes of conduction hearing loss. In case of otosclerosis, changes in oscillation amplitude at the umbo had been showed via Laser-Doppler-Vibrometry. Material and Methods: The eOCT system utilizes a swept source laser with a wave length around 1300nm. Field-of-view and working ...
      Read Full Article
    8. Endoscopic optical coherence tomography with wide field-of-view for the morphological and functional assessment of the human tympanic membrane

      Endoscopic optical coherence tomography with wide field-of-view for the morphological and functional assessment of the human tympanic membrane
      An endoscopic optical coherence tomography (OCT) system with a wide field-of-view of 8 mm is presented, which combines the image capability of endoscopic imaging at the middle ear with the advantages of functional OCT imaging, allowing a morphological and functional assessment of the human tympanic membrane. The endoscopic tube has a diameter of 3.5 mm and contains gradient-index optics for simultaneous forward-viewing OCT and video endoscopy. The endoscope allows ...
      Read Full Article
    9. Visualization of interfacial adhesive defects at dental restorations with spectral domain and polarization sensitive optical coherence tomography

      Visualization of interfacial adhesive defects at dental restorations with spectral domain and polarization sensitive optical coherence tomography
      Restoration loss based on interfacial adhesive defects and associated caries at the restoration margin are the main causes for invasive replacement of dental restorations. Assessment of the interfacial quality based on clinical inspection and radiographic examination is often difficult and not reliable. In this work, we present spectral domain optical coherence tomography (SDOCT) and polarization sensitive optical coherence tomography (PSOCT) for the evaluation of tooth-composite bond failure. Imaging of two ...
      Read Full Article
    10. Optical Coherence Tomography for NDE (Book Chapter)

      Optical Coherence Tomography for NDE (Book Chapter)
      Optical coherence tomography (OCT) is a noninvasive, high-resolution, interferometric imaging modality using near-infrared light to acquire cross sections and three-dimensional images of the subsurface microstructure of samples. Because of the rapid enhancement of OCT with respect to acquisition speed and axial resolution over the past years, OCT is becoming more and more attractive for applications in nondestructive testing and evaluation. In this chapter, a brief introduction to the technique and ...
      Read Full Article
    11. A System for Clinical Use of Endoscopic Optical Coherence Tomography

      A System for Clinical Use of Endoscopic Optical Coherence Tomography
      Introduction: Optical Coherence Tomography (OCT) allows non-invasive high-resolution imaging of tissues. With a penetration depth of a few millimeters it's possible to image the tympanic membrane and the close-by part of the tympanum, e.g. for diagnostics of otitis media and middle ear effusion. In the field of in vivo examination there are difficulties in access to the human tympanic membrane due to the narrow and curved external ear ...
      Read Full Article
    12. Multimodal imaging of lung tissue dynamics in mechanically ventilated rats with optical coherence tomography and intravital microscopy

      Multimodal imaging of lung tissue dynamics in mechanically ventilated rats with optical coherence tomography and intravital microscopy
      The understanding of alveolar mechanics is an essential step towards new and more protective ventilation strategies which are of dare need for the treatment of diseases of lung tissue and the airways. Such ailments become a major task for medical care and health care systems in modern industrial countries in the future. Besides the obvious importance as life-saving intervention, the mechanical strain and processes on the level of gas exchange ...
      Read Full Article
    13. 4D optical coherence tomography for imaging aortic valve dynamics ex vivo

      4D optical coherence tomography for imaging aortic valve dynamics ex vivo
      The mechanical components of the heart, especially the valves, are enormously stressed during lifetime and undergo different pathophysiological tissue transformations, which affect cardiac output and in consequence living comfort of affected patients. Calcific aortic valve stenosis (AVS) is the most common valve disease in modern industrial countries but the pathogenesis and progression of this disease is still unknown. Therefore, animal models, especially mouse models, are a powerfull tool to investigate ...
      Read Full Article
    14. In vivo imaging in the oral cavity by endoscopic optical coherence tomography

      In vivo imaging in the oral cavity by endoscopic optical coherence tomography
      The common way to diagnose hard and soft tissue irregularities in the oral cavity is initially the visual inspection by an experienced dentist followed by further medical examinations, such as radiological imaging and/or histopathological investigation. For the diagnosis of oral hard and soft tissues, the detection of early transformations is mostly hampered by poor visual access, low specificity of the diagnosis techniques, and/or limited feasibility of frequent screenings ...
      Read Full Article
    15. Detection of carious lesions utilizing depolarization imaging by polarization sensitive optical coherence tomography

      Detection of carious lesions utilizing depolarization imaging by polarization sensitive optical coherence tomography
      As dental caries is one of the most common diseases, the early and noninvasive detection of carious lesions plays an important role in public health care. Optical coherence tomography (OCT) with its ability of depth-resolved, high-resolution, noninvasive, fast imaging has been previously recognized as a promising tool in dentistry. Additionally, polarization sensitive imaging provides quantitative measures on the birefringent tissue properties and can be utilized for imaging dental tissue, especially ...
      Read Full Article
    16. In vivo imaging of human oral hard and soft tissues by polarization-sensitive optical coherence tomography

      In vivo imaging of human oral hard and soft tissues by polarization-sensitive optical coherence tomography
      Since optical coherence tomography (OCT) provides three-dimensional high-resolution images of biological tissue, the benefit of polarization contrast in the field of dentistry is highlighted in this study. Polarization-sensitive OCT (PS OCT) with phase-sensitive recording is used for imaging dental and mucosal tissues in the human oral cavity in vivo . An enhanced polarization contrast of oral structures is reached by analyzing the signals of the co- and crosspolarized channels of the ...
      Read Full Article
    17. Advanced analysis of domain walls in Mg doped LiNbO3 crystals with high resolution OCT

      Advanced analysis of domain walls in Mg doped LiNbO3 crystals with high resolution OCT
      The structure of domain walls (DW) in ferroelectric media is of great interest as this material is used for frequency doublers and other applications. We show that the structure of the DWs can nicely be visualized by high resolution optical coherence tomography (OCT). While the high group refractive index of lithium niobate allows a resolution much better than 1 m, the large dispersion can blur the image and has to ...
      Read Full Article
    18. Improved Imaging of Magnetically Labeled Cells Using Rotational Magnetomotive Optical Coherence Tomography

      Improved Imaging of Magnetically Labeled Cells Using Rotational Magnetomotive Optical Coherence Tomography
      Abstract In this paper, we present a reliable and robust method for magnetomotive optical coherence tomography (MM-OCT) imaging of single cells labeled with iron oxide particles. This method employs modulated longitudinal and transverse magnetic fields to evoke alignment and rotation of anisotropic magnetic structures in the sample volume. Experimental evidence suggests that magnetic particles assemble themselves in elongated chains when exposed to a permanent magnetic field. Magnetomotion in the intracellular ...
      Read Full Article
    19. Flow Measurement by Lateral Resonant Doppler Optical Coherence Tomography in the Spectral Domain

      Flow Measurement by Lateral Resonant Doppler Optical Coherence Tomography in the Spectral Domain
      In spectral domain optical coherence tomography (SD-OCT), any transverse motion component of a detected obliquely moving sample results in a nonlinear relationship between the Doppler phase shift and the axial sample velocity restricting phase-resolved Doppler OCT (PR-DOCT). The size of the deviation from the linear relation depends on the amount of the transverse velocity component, given by the Doppler angle, and the height of the absolute sample velocity. Especially for ...
      Read Full Article
    20. Optical Coherence Tomography (OCT) for Time-Resolved Imaging of Alveolar Dynamics in Mechanically Ventilated Rats

      Optical Coherence Tomography (OCT) for Time-Resolved Imaging of Alveolar Dynamics in Mechanically Ventilated Rats
      Though artificial ventilation is an essential life-saving treatment, the mechanical behavior of lung tissue at the alveolar level is still unknown. Therefore, we need to understand the tissue response during artificial ventilation at this microscale in order to develop new and more protective ventilation methods. Optical coherence tomography (OCT) combined with intravital microscopy (IVM) is a promising tool for visualizing lung tissue dynamics with a high spatial and temporal resolution ...
      Read Full Article
    21. Impact of a detector dead time in phase-resolved Doppler analysis using spectral domain optical coherence tomography

      Impact of a detector dead time in phase-resolved Doppler analysis using spectral domain optical coherence tomography
      For any oblique sample movement containing a transverse velocity component, the commonly used linear relationship between the phase shift and the axial velocity component is erroneous for spectrometer-based optical coherence tomography (spectral domain OCT, SD-OCT). We recently proposed a new Doppler model that assumes a continuous integration of the photocurrent. In this research, we extend the model for detectors with a shutter control by taking detector dead time into account ...
      Read Full Article
    22. Doppler optical coherence tomography as a promising tool for detecting fluid in the human middle ear

      Doppler optical coherence tomography as a promising tool for detecting fluid in the human middle ear
      The treatment of otitis media requires classifying the effusion in the tympanic cavity for choosing appropriate therapeutic strategies. Otoscopic examination of the middle ear depends on the expertise of the physician and is often hampered in case of inflammatory alterations of the tympanic membrane. In otologic research, optical coherence tomography is an innovative non-invasive imaging technique utilized for visualizing the tympanic membrane. This ex vivo study presents the possibility of ...
      Read Full Article
    23. Improved non-invasive Optical Coherence Tomography detection of different engineered nanoparticles in food-mimicking matrices

      Improved non-invasive Optical Coherence Tomography detection of different engineered nanoparticles in food-mimicking matrices
      Food industry and regulators require fast and reliable analytical methods for quality control. This especially counts for the detection of engineered nanomaterials (ENMs) in food products. Respective EU regulation is in force, but the development of appropriate methods is still underway. This paper updates the scope of Optical Coherence Tomography (OCT) for ENM/food matrix analysis. A range of nanomaterials and composites Au@SiO 2 , Ag, Ag@SiO 2 and ...
      Read Full Article
    24. 1-24 of 106 1 2 3 4 5 »
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Organizations in the News

    1. (3 articles) University of Toronto
    2. (2 articles) University of Lübeck
    3. (2 articles) RWTH Aachen University
    4. (1 articles) Medical University of Vienna
    5. (1 articles) National Institutes of Health
    6. (1 articles) Ludwig Maximilian University of Munich
    7. (1 articles) Nicolaus Copernicus University
    8. (1 articles) University of Freiburg
    9. (1 articles) University of Western Australia
  3. People in the News

    1. (45 articles) Julia Walther
    2. (33 articles) Sven Meissner
    3. (32 articles) Lars Kirsten
    4. (27 articles) Peter Cimalla
    5. (25 articles) Maria Gaertner
    6. (9 articles) Henning Morawietz
    7. (4 articles) Alexander Krüger
    8. (3 articles) Mikael Timo Erkkilä
    9. (1 articles) Karol Karnowski
    10. (1 articles) Martin L. Villiger
    11. (1 articles) David D. Sampson
    12. (1 articles) University of Leipzig
  4. OCT Companies in the News

    1. (1 articles) Physical Sciences Incorporated
    2. (1 articles) NKT Photonics