1. Articles from arxiv.org

  2. 1-24 of 178 1 2 3 4 5 6 7 8 »
    1. Spectrally Extended Line Field Optical Coherence Tomography Angiography

      Spectrally Extended Line Field Optical Coherence Tomography Angiography

      Optical coherence tomography angiography (OCTA) has been established as a powerful tool for investigating vascular diseases and is expected to become a standard of care technology. However, its widespread clinical usage is hindered by technical gaps such as limited field of view (FOV), lack of quantitative flow information, and suboptimal motion correction. Here we report a new imaging platform, termed spectrally extended line field (SELF) OCTA that provides advanced solutions to the above-mentioned challenges. SELF-OCTA breaks the speed limitations and achieves two-fold gain in FOV without sacrificing signal strength through parallel image acquisition. Towards quantitative angiography, the ‘frequency flow’ imaging ...

      Read Full Article
    2. Detection of subtle cartilage and bone tissue degeneration in the equine joint using polarisation-sensitive optical coherence tomography

      Detection of subtle cartilage and bone tissue degeneration in the equine joint using polarisation-sensitive optical coherence tomography

      Objective: To explore the ability of polarisation-sensitive optical coherence tomography (PS-OCT) to rapidly identify subtle signs of tissue degeneration in the equine joint. Design: Polarisation-sensitive optical coherence tomography (PS-OCT) images were systematically acquired in four locations along the medial and lateral condyles of the third metacarpal bone in 5 equine specimens. Intensity and retardation PS-OCT images, and anomalies observed therein, were then compared and validated with high resolution images of the tissue sections obtained using Differential Interference contrast (DIC) optical light microscopy. Results: The PS-OCT system was capable of imaging the entire equine osteochondral unit, and allowed delineation of the ...

      Read Full Article
    3. Spatio-Temporal Optical Coherence Tomography provides advanced imaging of the human retina and choroid

      Spatio-Temporal Optical Coherence Tomography  provides advanced imaging of the human retina and choroid

      One of the greatest needs in modern ophthalmology is access to the eye’s choroid in vivo. Without it, it is difficult to introduce new therapies and to understand most of the pathological changes in the eye, because 85% of the total blood flow in the eye i s caused by the choroidal circulation. It is entirely responsible for the metabolism of photoreceptors, which each of us feels every day and senses when its deficits begin. Optical selection of choroid and choriocapillaris by currently used imaging techniq ues such as indocyanine angiography, scanning laser ophthalmoscopy or optical coherence tomography (OCT ...

      Read Full Article
    4. Elastic deformation of optical coherence tomography images of diabetic macular edema for deep-learning models training: how far to go?

      Elastic deformation of optical coherence tomography images of diabetic macular edema for deep-learning models training: how far to go?

      Purpose : To explore the clinical validity of elastic deformation of optical coherence tomography (OCT) images for data augmentation in the development of deep - learning model for detection of diabetic macular edema (DME). Design: Prospective evaluation of OCT image s of DME (n=320) subject to elastic transformation, with the deformation intensity represented by (σ). Methods : Three sets of images, each comprising 100 pairs of scans (100 original & 100 modified), were grouped accordin g to the range of (σ), including low - , medium - and high - degree of augmentation; (σ =1 - 6), (σ =7 - 12), and (σ =13 - 18), respectively. I mages subject to extremely high augmentation ( σ =19 ...

      Read Full Article
    5. Domain Adaptation via CycleGAN for Retina Segmentation in Optical Coherence Tomography

      Domain Adaptation via CycleGAN for Retina Segmentation in Optical Coherence Tomography

      With the FDA approval of Artificial Intelligence (AI) for point-of-care clinical diagnoses, model generalizability is of the utmost importance as clinical decision-making must be domain-agnostic. A method of tackling the problem is to increase the dataset to include images from a multitude of domains; while this technique is ideal, the security requirements of medical data is a major limitation. Additionally, researchers with developed tools benefit from the addition of open-sourced data, but are limited by the difference in domains. Herewith, we investigated the implementation of a Cycle-Consistent Generative Adversarial Networks (CycleGAN) for the domain adaptation of Optical Coherence Tomography (OCT ...

      Read Full Article
    6. Non invasive live imaging of a novel RPE stress model with Dynamic Full-Field OCT

      Non invasive live imaging of a novel RPE stress model with Dynamic Full-Field OCT

      Retinal degenerative diseases lead to the blindness of millions of people around the world. In case of age-related macular degeneration (AMD), the atrophy of retinal pigment epithelium (RPE) precedes neural dystrophy. But as crucial as understanding both healthy and pathological RPE cell physiology is for those diseases, no current technique allows subcellular in vivo or in vitro live observation of this critical cell layer. To fill this gap, we propose dynamic full-field OCT (D-FFOCT) as a candidate for live observation of in vitro RPE phenotype. In this way, we monitored primary porcine and human stem cell-derived RPE cells in stress ...

      Read Full Article
    7. Pointwise visual field estimation from optical coherence tomography in glaucoma: a structure-function analysis using deep learning

      Pointwise visual field estimation from optical coherence tomography in glaucoma: a structure-function analysis using deep learning

      Background /Aims : Standard Automated Perimetry (SAP) is the gold standard to monitor visual field (VF) loss in glaucoma management, but is prone to intra - subject variability. We developed and validated a deep learning (DL) regression model that estimates pointwise and overall VF loss from unsegmented optical coherence tomography (OCT) scans. Methods : Eight DL regression models were trained with various retinal imaging modalities: circumpapillar y OCT at 3.5mm, 4.1mm, 4.7mm diameter, and scanning laser ophthalmoscopy (SLO) en face images to estimate mean deviation (MD) and 52 threshold values. This retrospective study used data from patients who underwent a ...

      Read Full Article
    8. Measurement of two-point coherence functions of electromagnetic optical fields and applications of optical coherence

      Measurement of two-point coherence functions of electromagnetic optical fields and applications of optical coherence

      For stationary light fields , manifestation of statistical properties such as coherence and polarization are attributed to the same physical phenomena, i.e. correlations in fluctuations of optical fields. In order to explain various properties associated with electromagnetic optical fields, both coherence and polarization need to be placed at same footings. This leads to two - point (space or time) generalization of single - point properties such as Stokes parameters and elements of coherency matrix. This paper reviews the basic aspects concerning vectorial optical fields and experimental methods developed during last couple of decades for the measurement of two - point correlation functions of ...

      Read Full Article
    9. Delineating corneal elastic anisotropy in a porcine model using non-contact optical coherence elastography and ex vivo mechanical tests

      Delineating corneal elastic anisotropy in a porcine model using non-contact optical coherence elastography and ex vivo mechanical tests

      Objective : To compare non - contact acoustic micro - tapping optical coherence elastography ( AμT - OCE ) with destructive mechanical tests to confirm corneal elastic anisotropy. Design : Ex vivo, laboratory study with non - contact AμT - OCE followed by mechanical rheometry and extensometry . Subjects: Infl ated cornea of whole - globe porcine eyes ( n =9). Methods: A non - contact AμT transducer was used to launch propagating mechanical waves in the cornea that were imaged with phase - sensitive OCT at physiologically relevant controlled pressures . Reconstruction o f both Young’s modulus ( E ) and out - of - plane shear modulus ( G ) in the cornea from experimental ...

      Read Full Article
    10. Time-encoded mid-infrared Fourier-domain optical coherence tomography

      Time-encoded mid-infrared Fourier-domain optical coherence tomography

      In this contribution, we report on a technically simple approach to high-resolution and sensitive spectral-domain OCT imaging in the mid-infrared range. The proposed OCT system employs an InF 3 supercontinuum source; for detection, a time-encoded spectrometer based on a single InAsSb point detector is used. The developed spectrometer enables structural imaging in the spectral range from around 3140 nm to 4190 nm with a characterised sensitivity above 80 dB and an axial resolution below 8 μm. The capabilities of the system are exhibited for imaging of porous ceramic samples and transition-stage green parts fabricated using an emerging method of lithography-based ...

      Read Full Article
      Mentions: RECENDT
    11. Corneal Pachymetry by AS-OCT after Descemet's Membrane Endothelial Keratoplasty

      Corneal Pachymetry by AS-OCT after Descemet's Membrane Endothelial Keratoplasty

      Corneal thickness (pachymetry) maps can be used to monitor restoration of corneal endothelial function, for example after Descemet's membrane endothelial keratoplasty (DMEK). Automated delineation of the corneal interfaces in anterior segment optical coherence tomography (AS-OCT) can be challenging for corneas that are irregularly shaped due to pathology, or as a consequence of surgery, leading to incorrect thickness measurements.

      Read Full Article
    12. Motion Estimation for Optical Coherence Elastography Using Signal Phase and Intensity

      Motion Estimation for Optical Coherence Elastography Using Signal Phase and Intensity

      Abstract —Displacement estimation in optical coherence tomog- raphy (OCT) imaging is relevant for several potential applica- tions, e.g. for optical coherence elastography (OCE) for corneal biomechanical characterization. Larger displacements may be resolved using correlation-based block matching techniques, which however are prone to signal de-correlation and imprecise at commonly desired sub-pixel resolutions. Phase-based tracking methods can estimate tiny sub-wavelength motion, but are not suitable for motion magnitudes larger than half the wavelength due to phase wrapping and the difficulty of any unwrapping due to noise. In this paper a robust OCT displacement estimation method is introduced by formulating tracking as ...

      Read Full Article
    13. Three-Dimensional Virtual Histology in Unprocessed Resected Tissues with Photoacoustic Remote Sensing (PARS) Microscopy and Optical Coherence Tomography

      Three-Dimensional Virtual Histology in Unprocessed Resected Tissues with Photoacoustic Remote Sensing (PARS) Microscopy and Optical Coherence Tomography

      Histological images are critical in the diagnosis and treatment of cancers. Unfortunately, the current method for capturing these microscopy images require resource intensive tissue preparation that delays diagnosis for many days to a few weeks. To streamline this process, clinicians are limited to assessing small macroscopically representative subsets of tissues. Here, we present a combined photoacoustic remote sensing (PARS) microscope and swept source optical coherence tomography (SS-OCT) system designed to circumvent these diagnostic limitations. The proposed multimodal microscope provides label-free three-dimensional depth resolved virtual histology visualizations, capturing nuclear and extranuclear tissue morphology directly on thick unprocessed specimens. The capabilities of ...

      Read Full Article
    14. Automated segmentation of choroidal layers from 3-dimensional macular optical coherence tomography scans

      Automated segmentation of choroidal layers from 3-dimensional macular optical coherence tomography scans

      Background: Changes in choroidal thickness are associated with various ocular diseases and the choroid can be imaged using spectral-domain optical coherence tomography (SDOCT) and enhanced depth imaging OCT (EDIOCT). New Method: Eighty macular SDOCT volumes from 80 patients were obtained using the Zeiss Cirrus machine. Eleven additional control subjects had two Cirrus scans done in one visit along with EDIOCT using the Heidelberg Spectralis machine. To automatically segment choroidal layers from the OCT volumes, our graph-theoretic approach was utilized. The segmentation results were compared with reference standards from two graders, and the accuracy of automated segmentation was calculated using unsigned ...

      Read Full Article
    15. Non-contact, in-vivo, functional, and structural ophthalmic imaging using multimodal photoacoustic remote sensing (PARS) microscopy and optical coherence tomography (OCT)

      Non-contact, in-vivo, functional, and structural ophthalmic imaging using multimodal photoacoustic remote sensing (PARS) microscopy and optical coherence tomography (OCT)

      Early diagnosis of ocular diseases improves the understanding of pathophysiology and helps with accurate monitoring and effective treatment. Advanced multimodal ocular imaging platforms play a crucial role in the visualization of the ocular components and provide clinicians with a valuable tool for evaluating different eye diseases. Here, for the first time, we present a non-contact, multimodal photoacoustic remote sensing (PARS) microscopy and swept-source optical coherence tomography (SS-OCT) for in-vivo functional and structural imaging of the eye. The system provides complementary imaging contrasts of optical absorption and optical scattering and is used for non-contact, in-vivo imaging of the murine eye. Results ...

      Read Full Article
    16. Speckle Statistics of Biological Tissues in Optical Coherence Tomography

      Speckle Statistics of Biological Tissues in Optical Coherence Tomography

      The speckle statistics of optical coherence tomography images of biological tissue have been studied using several historical probability density functions. A recent hypothesis implies that underlying power-law distributions in the medium structure, such as the fractal branching vasculature, will contribute to power-law probability distributions of speckle statistics. Specifically, these are the Burr type XII distribution for speckle amplitude, the Lomax distribution for intensity, and the generalized logistic distribution for log amplitude. In this study, these three distributions are fitted to histogram data from nine optical coherence tomography scans of various biological tissues and samples. The distributions are also compared with ...

      Read Full Article
    17. Manifestation of aberrations in full-field optical coherence tomography

      Manifestation of aberrations in full-field optical coherence tomography

      We report on a theoretical model for image formation in full-field optical coherence tomography (FFOCT). Because the spatial incoherence of the illumination acts as a virtual confocal pinhole in FFOCT, its imaging performance is equivalent to a scanning time-gated coherent confocal microscope. In agreement with optical experiments enabling a precise control of aberrations, FFOCT is shown to have nearly twice the resolution of standard imaging at moderate aberration level. Beyond a rigorous study on the sensitivity of FFOCT with respect to aberrations, this theoretical model paves the way towards an optimized design of adaptive optics schemes for high-resolution and deep ...

      Read Full Article
    18. Analyzing Epistemic and Aleatoric Uncertainty for Drusen Segmentation in Optical Coherence Tomography Images

      Analyzing Epistemic and Aleatoric Uncertainty for Drusen Segmentation in Optical Coherence Tomography Images

      Age-related macular degeneration (AMD) is one of the leading causes of permanent vision loss in people aged over 60 years. Accurate segmentation of biomarkers such as drusen that points to the early stages of AMD is crucial in preventing further vision impairment. However, segmenting drusen is extremely challenging due to their varied sizes and appearances, low contrast and noise resemblance. Most existing literature, therefore, have focused on size estimation of drusen using classification, leaving the challenge of accurate segmentation less tackled. Additionally, obtaining the pixel-wise annotations is extremely costly and such labels can often be noisy, suffering from inter-observer and ...

      Read Full Article
    19. Inverse spectroscopic optical coherence tomography (ISOCT) for characterization of particle size and concentration

      Inverse spectroscopic optical coherence tomography (ISOCT) for characterization of particle size and concentration

      Inverse spectroscopic optical coherence tomography (IS-OCT) methods apply inverse problem formulations to acquired spectra to estimate depth-resolved sample properties. In the current study, we modelled the time-frequency-distributions using Lambert-Beer law and implemented IS-OCT using backscattering spectra calculated from Mie theory, then demonstrated the algorithm on polystyrene microspheres under idealized conditions. The results are significant because the method is compatible with high concentrations and broad diameter distributions of scattering particles such as organelles in biological cells.

      Read Full Article
    20. In Vivo Quantitative Analysis of Anterior Chamber White Blood Cell Mixture Composition Using Spectroscopic Optical Coherence Tomography

      In Vivo Quantitative Analysis of Anterior Chamber White Blood Cell Mixture Composition Using Spectroscopic Optical Coherence Tomography

      Anterior uveitis is the most common form of intraocular inflammation, and one of its main signs is the presence of white blood cells (WBCs) in the anterior chamber (AC). Clinically, the true composition of cells can currently only be obtained using AC paracentesis, an invasive procedure to obtain AC fluid requiring needle insertion into the AC. We previously developed a spectroscopic optical coherence tomography (SOCT) analysis method to differentiate between populations of RBCs and subtypes of WBCs, including granulocytes, lymphocytes and monocytes, both in vitro and in ACs of excised porcine eyes. We have shown that different types of WBCs ...

      Read Full Article
      Mentions: Duke University
    21. Maximum A Posteriori Signal Recovery for Optical Coherence Tomography Angiography Image Generation and Denoising

      Maximum A Posteriori Signal Recovery for Optical Coherence Tomography Angiography Image Generation and Denoising

      Optical coherence tomography angiography (OCTA) is a novel and clinically promising imaging modality to image retinal and sub-retinal vasculature. Based on repeated optical coherence tomography (OCT) scans, intensity changes are observed over time and used to compute OCTA image data. OCTA data are prone to noise and artifacts caused by variations in flow speed and patientmovement. We propose a novel iterativemaximuma posteriori signal recovery algorithm in order to generate OCTA volumes with reduced noise and increased image quality. This algorithm is based on previous work on probabilistic OCTA signal models and maximum likelihood estimates. Reconstruction results using total variation minimization ...

      Read Full Article
    22. Low Tensor Train- and Low Multilinear Rank Approximationsfor De-speckling and Compression of 3D Optical Coherence Tomography Images

      Low Tensor Train- and Low Multilinear Rank Approximationsfor De-speckling and Compression of 3D Optical Coherence Tomography Images

      This paper proposes low tensor-train (TT) rank and low multilinear (ML) rank approximations for de-speckling and compression of 3D optical coherence tomography (OCT) images for a given compression ratio (CR). To this end, we derive the alternating direction method of multipliers based algorithms for the related problems constrained with the low TT- and low ML rank. Rank constraints are implemented through the Schatten-p (Sp) norm, p e {0, 1/2, 2/3, 1}, of unfolded matrices. We provide the proofs of global convergence towards a stationary point for both algorithms. Rank adjusted 3D OCT image tensors are finally approximated through ...

      Read Full Article
    23. Self-supervised Denoising via Diffeomorphic Template Estimation: Application to Optical Coherence Tomography

      Self-supervised Denoising via Diffeomorphic Template Estimation: Application to Optical Coherence Tomography

      Optical Coherence Tomography (OCT) is pervasive in both the research and clinical practice of Ophthalmology. However, OCT images are strongly corrupted by noise, limiting their interpretation. Current OCT denoisers leverage assumptions on noise distributions or generate targets for training deep supervised denoisers via averaging of repeat acquisitions. However, recent self-supervised advances allow the training of deep denoising networks using only repeat acquisitions without clean targets as ground truth, reducing the burden of supervised learning. Despite the clear advantages of self-supervised methods, their use is precluded as OCT shows strong structural deformations even between sequential scans of the same subject due ...

      Read Full Article
    24. High space-bandwidth in quantitative phase imaging using partially spatially coherent optical coherence microscopy and deep neural network

      High space-bandwidth in quantitative phase imaging using partially spatially coherent optical coherence microscopy and deep neural network

      Quantitative phase microscopy (QPM) is a label-free technique that enables to monitor morphological changes at subcellular level. The performance of the QPM system in terms of spatial sensitivity and resolution depends on the coherence properties of the light source and the numerical aperture (NA) of objective lenses. Here, we propose high space-bandwidth QPM using partially spatially coherent optical coherence microscopy (PSC-OCM) assisted with deep neural network. The PSC source synthesized to improve the spatial sensitivity of the reconstructed phase map from the interferometric images. Further, compatible generative adversarial network (GAN) is used and trained with paired low-resolution (LR) and high-resolution ...

      Read Full Article
    1-24 of 178 1 2 3 4 5 6 7 8 »
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks