1. Articles from arxiv.org

  2. 1-24 of 52 1 2 3 »
    1. Eckhaus Instability in the Fourier-Domain Mode Locked Fiber Laser Cavity

      Eckhaus Instability in the Fourier-Domain Mode Locked Fiber Laser Cavity

      High frequency fluctuation in the optical signal generated in Fourier-Domain Mode Locked fiber laser (FDML-FL), which is the major problem and degrades the laser performance, is not yet fully analyzed or studied. The basic theory which is causing this high frequency fluctuation is required to clearly understand its dynamics and to control it for various applications. In this letter, by analyzing the signal and system dynamics of FDML-FL, we theoretically demonstrate that the high frequency fluctuation is induced by the intrinsic instability of frequency offset of the signal in cavity with nonlinear gain and spectral filter. Unlike the instabilities observed ...

      Read Full Article
    2. Optical sectioning in induced coherence tomography with frequency-entangled photons

      Optical sectioning in induced coherence tomography with frequency-entangled photons

      We demonstrate an experimental configuration to perform optical sectioning of a sample based on the concept of induced coherence [Zou et al., Phys. Rev. Lett. 67, 3187 (1991)]. This can be viewed as a new type of optical coherence tomography scheme, where different reflectivities of the sample under study translates into changes of the degree of first-order coherence between two beams. The induced coherence tomography scheme proposed here uses frequency-entangled photons embedded in a nonlinear interferometer. As practical advantage the scheme allows probing the sample with one wavelength and measuring light with another wavelength. In a bio-imaging scenario, this would ...

      Read Full Article
    3. A Deep Learning Approach to Digitally Stain Optical Coherence Tomography Images of the Optic Nerve Head

      A Deep Learning Approach to Digitally Stain Optical Coherence Tomography Images of the Optic Nerve Head

      Purpose. To develop a deep learning approach to digitally-stain optical coherence tomography (OCT) images of the optic nerve head (ONH). Methods. A horizontal B-scan was acquired through the center of the ONH using OCT (Spectralis) for 1 eye of each of 100 subjects (40 normal & 60 glaucoma). All images were enhanced using adaptive compensation. A custom deep learning network was then designed and trained with the compensated images to digitally stain (i.e. highlight) 6 tissue layers of the ONH. The accuracy of our algorithm was assessed (against manual segmentations) using the Dice coefficient, sensitivity, and specificity. We further studied ...

      Read Full Article
    4. Universal in vivo Textural Model for Human Skin based on Optical Coherence Tomograms

      Universal in vivo Textural Model for Human Skin based on Optical Coherence Tomograms

      Currently, diagnosis of skin diseases is based primarily on visual pattern recognition skills and expertise of the physician observing the lesion. Even though dermatologists are trained to recognize patterns of morphology, it is still a subjective visual assessment. Tools for automated pattern recognition can provide objective information to support clinical decision-making. Noninvasive skin imaging techniques provide complementary information to the clinician. In recent years, optical coherence tomography has become a powerful skin imaging technique. According to specific functional needs, skin architecture varies across different parts of the body, as do the textural characteristics in OCT images. There is, therefore, a ...

      Read Full Article
    5. Blood capillaries and vessels segmentation in optical coherence tomography angiogram using fuzzy C-means and Curvelet transform

      Blood capillaries and vessels segmentation in optical coherence tomography angiogram using fuzzy C-means and Curvelet transform

      Blood capillaries density and vessels structure in vivo brain provide information about diseases and hemodynamic in the brain network. Capillary density in animal brain is one of the indexes that determines if it has diabetes. Capillary density in the animal brain subjected to diabetes diminishes over time. Variation in physical structure and diameter of the vessels as a function of time gives us information about hemodynamic in the brain network as well. Capillaries and vessels segmentation is a process that can help us in predicting some of diseases such as diabetes as well as monitoring certain area of the brain ...

      Read Full Article
    6. Fast subsurface fingerprint imaging with full-field optical coherence tomography system equipped with a silicon camera

      Fast subsurface fingerprint imaging with full-field optical coherence tomography system equipped with a silicon camera

      Images recorded below the surface of a finger can have more details and be of higher quality than conventional surface fingerprint images. This is particularly true when the quality of the surface fingerprints is compromised by, for example, moisture or surface damage. However, there is an unmet need for a cost effective fingerprint sensor that could record high-quality images at sufficient depth below the surface and in short-enough time. To this end, we report on a relatively inexpensive full-field optical coherent tomography (FF-OCT) system comprised of a novel silicon camera and a LED source emitting at 850 nm. The system ...

      Read Full Article
    7. The inverse scattering problem for orthotropic media in Polarization-sensitive Optical Coherence Tomography

      The inverse scattering problem for orthotropic media in Polarization-sensitive Optical Coherence Tomography

      In this paper we provide a mathematical model for imaging an anisotropic, orthotropic medium with Polarization-Sensitive Optical Coherence Tomography (PS-OCT). The imaging problem is formulated as an inverse scattering problem in three dimensions for reconstructing the electrical susceptibility of the medium using Maxwell’s equations. Our reconstruction method is based on the second-order Born-approximation of the electric field.

      Read Full Article
    8. ReLayNet: Retinal Layer and Fluid Segmentation of Macular Optical Coherence Tomography using Fully Convolutional Network

      ReLayNet: Retinal Layer and Fluid Segmentation of Macular Optical Coherence Tomography using Fully Convolutional Network

      Optical coherence tomography (OCT) is extensively used for diagnosis of diabetic macular edema due to its non-invasive imaging based assessment of the retinal layers. In this paper, we propose a new fully convolutional deep learning architecture, termed ReLayNet, for segmentation of retinal layers and fluid masses in eye OCT scans. ReLayNet uses a contracting path of convolutional blocks (encoders) to learn a heirarchy of contextual features, followed by an expansive path of convolutional blocks (decoders) for semantic segmentation. Additionally, skip connections relaying encoder outputs to matched decoder inputs are introduced to recover spatial information lost during downsampling. ReLayNet is trained ...

      Read Full Article
    9. Intraoperative margin assessment of human breast tissue in optical coherence tomography images using deep neural networks

      Intraoperative margin assessment of human breast tissue in optical coherence tomography images using deep neural networks

      Objective: In this work, we perform margin assessment of human breast tissue from optical coherence tomography (OCT) images using deep neural networks (DNNs). This work simulates an intraoperative setting for breast cancer lumpectomy. Methods: To train the DNNs, we use both the state-of-the-art methods (Weight Decay and DropOut) and a newly introduced regularization method based on function norms. Commonly used methods can fail when only a small database is available. The use of a function norm introduces a direct control over the complexity of the function with the aim of diminishing the risk of overfitting. Results: As neither the code ...

      Read Full Article
    10. QuaSI: Quantile Sparse Image Prior for Spatio-Temporal Denoising of Retinal OCT Data

      QuaSI: Quantile Sparse Image Prior for Spatio-Temporal Denoising of Retinal OCT Data

      Optical coherence tomography (OCT) enables high-resolution and non-invasive 3D imaging of the human retina but is inherently impaired by speckle noise. This paper introduces a spatio-temporal denoising algorithm for OCT data on a B-scan level using a novel quantile sparse image (QuaSI) prior. To remove speckle noise while preserving image structures of diagnostic relevance, we implement our QuaSI prior via median filter regularization coupled with a Huber data fidelity model in a variational approach. For efficient energy minimization, we develop an alternating direction method of multipliers (ADMM) scheme using a linearization of median filtering. Our spatio-temporal method can handle both ...

      Read Full Article
    11. Reproducibility of Retinal Thickness Measurements across Spectral-Domain Optical Coherence Tomography Devices using Iowa Reference Algorithm

      Reproducibility of Retinal Thickness Measurements across Spectral-Domain Optical Coherence Tomography Devices using Iowa Reference Algorithm

      PURPOSE: Establishing and obtaining consistent quantitative indices of retinal thickness from a variety of clinically used Spectral-Domain Optical Coherence Tomography scanners. DESIGN: Retinal images from five Spectral-Domain Optical Coherence Tomography scanners were used to determine total retinal thickness with scanner-specific correction factors establishing consistency of thickness measurement across devices. PARTICIPANTS: 55 Fovea-centered Spectral-Domain Optical Coherence Tomography volumes from eleven subjects were analyzed, obtained from Cirrus HD-OCT, RS-3000, Heidelberg Spectralis, RTVue and Topcon2000, seven subjects with retinal diseases and four normal controls. METHOD: The Iowa Reference Algorithm measured total retinal thickness. Nonlinear model of total retinal thickness measurement comparisons was derived ...

      Read Full Article
    12. Collaborative effects of wavefront shaping and optical clearing agent in optical coherence tomography

      Collaborative effects of wavefront shaping and optical clearing agent in optical coherence tomography

      Developing a deep-tissue imaging tool with good optical resolution is one of the important goals of biophotonics because medical diagnosis usually requires imaging of fine details of whole tissue structures. Optical coherence tomography (OCT) is an extensively developed imaging tool for biological tissues. Based on low-coherence interferometry, OCT provides micrometer scale resolution and enables non-invasive high-speed imaging1 . OCT is widely used in ophthalmology because it can fully access retina, choroid and sclera layers of human eyes in vivo. 2, 3 OCT has a higher penetration depth of 12 mm compared to other optical imaging modalities such as multi-photon microscopy ...

      Read Full Article
    13. A signal separation technique for sub-cellular imaging using dynamic optical coherence tomography

      A signal separation technique for sub-cellular imaging using dynamic optical coherence tomography

      This paper aims at imaging the dynamics of metabolic activity of cells. Using dynamic optical coherence tomography, we introduce a new multiparticle dynamical model to simulate the movements of the collagen and the cell metabolic activity and develop an efficient signal separation technique for sub-cellular imaging. We perform a singular-value decomposition of the dynamic optical images to isolate the intensity of the metabolic activity. We prove that the largest eigenvalue of the associated Casorati matrix corresponds to the collagen. We present several numerical simulations to illustrate and validate our approach.

      Read Full Article
    14. Optical teardown of a Kindle Paperwhite display by OCT.

      Optical teardown of a Kindle Paperwhite display by OCT.

      An optical teardown, or reverse engineering, of an Amazon Kindle Paperwhite electrophoretic display was performed by Optical Coherence Tomography at 1060 nm. The display incorporates an optical diffuser, lightguide and scattering layers for white light illumination, capacitive touch sensing, and an electrophoretic display. All these layers can be imaged by OCT as well as the thin film transistor array on the back side for driving the pixels. Phase sensitive OCT is used to measure motion of the pigment particles as the display changes between black and white.

      Read Full Article
    15. Classical realization of dispersion-canceled, artifact-free, and background-free optical coherence tomography

      Classical realization of dispersion-canceled, artifact-free, and background-free optical coherence tomography

      Quantum-optical coherence tomography (Q-OCT) provides a dispersion-canceled axial-imaging method, but its practical use is limited by the weakness of the light source and by artifacts in the images. A recent study using chirped-pulse interferometry (CPI) has demonstrated dispersion-canceled and artifact-free OCT with a classical system; however, unwanted background signals still remain after removing the artifacts. Here, we propose a classical optical method that realizes dispersion-canceled, artifact-free, and background-free OCT. We employ a time-reversed system for Q-OCT with transform-limited input laser pulses to achieve dispersion-canceled OCT with a classical system. We have also introduced a subtraction method to remove artifacts and ...

      Read Full Article
    16. Inverse Problems of Combined Photoacoustic and Optical Coherence Tomography

      Inverse Problems of Combined Photoacoustic and Optical Coherence Tomography

      Optical coherence tomography (OCT) and photoacoustic tomography (PAT) are emerging non-invasive biological and medical imaging techniques. It is a recent trend in experimental science to design experiments that perform PAT and OCT imaging at once. In this paper we present a mathematical model describing the dual experiment. Since OCT is mathematically modelled by Maxwell's equations or some simplifications of it, whereas the light propagation in quantitative photoacoustics is modelled by (simplifications of) the radiative transfer equation, the first step in the derivation of a mathematical model of the dual experiment is to obtain a unified mathematical description, which in ...

      Read Full Article
    17. Dynamic full field optical coherence tomography: subcellular metabolic contrast revealed in tissues by temporal analysis of interferometric signals

      Dynamic full field optical coherence tomography: subcellular metabolic contrast revealed in tissues by temporal analysis of interferometric signals

      We developed a new endogenous approach to reveal subcellular metabolic contrast in fresh ex vivo tissues taking advantage of the time dependence of the full field optical coherence tomography interferometric signals. This method reveals signals linked with local activity of the endogenous scattering elements which can reveal cells where other imaging techniques fail or need exogenous contrast agents. We benefit from the micrometric transverse resolution of full field OCT to image intracellular features. We used this time dependence to identify different dynamics at the millisecond scale on a wide range of organs in normal or pathological conditions.

      Read Full Article
    18. Smart optical coherence tomography for ultra-deep imaging through highly scattering media

      Smart optical coherence tomography for ultra-deep imaging through highly scattering media

      Multiple scattering of waves in disordered media is a nightmare whether it be for detection or imaging purposes. The best approach so far to get rid of multiple scattering is optical coherence tomography. It basically combines confocal microscopy and coherence time-gating to discriminate ballistic photons from a predominant multiple scattering background. Nevertheless, the imaging depth range remains limited to 1 mm at best in human soft tissues. Here we propose a matrix approach of optical imaging to push back this fundamental limit. By combining a matrix discrimination of ballistic waves and iterative time-reversal, we show both theoretically and experimentally an ...

      Read Full Article
    19. In vivo deep tissue imaging using wavefront shaping optical coherence tomography

      In vivo deep tissue imaging using wavefront shaping optical coherence tomography

      Multiple light scattering in tissue limits the penetration of optical coherence tomography (OCT) imaging. Here, we present in-vivo OCT imaging of a live mouse using wavefront shaping to enhance the penetration depth. A digital micro-mirror device (DMD) was used in a spectral-domain OCT system for complex wavefront shaping of an incident beam which resulted in the optimal delivery of light energy into deep tissue. Ex-vivo imaging of chicken breasts and mouse ear tissues showed enhancements in the strength of the image signals and the penetration depth, and in-vivo imaging of the tail of a live mouse provided a multilayered structure ...

      Read Full Article
    20. High-speed optical correlation-domain reflectometry without using acousto-optic modulator

      High-speed optical correlation-domain reflectometry without using acousto-optic modulator

      To achieve a distributed reflectivity measurement along an optical fiber, we develop a simplified cost-effective configuration of optical correlation- (or coherence-) domain reflectometry based on a synthesized optical coherence function by sinusoidal modulation. By excluding conventional optical heterodyne detection (practically, without using an acoustooptic modulator) and by exploiting the foot of the Fresnel reflection spectrum, the electrical bandwidth required for signal processing is lowered down to several megahertz. We evaluate the basic system performance and demonstrate its high-speed operation (10 ms for one scan) by tracking a moving reflection point in real time.

      Read Full Article
    21. 3D Automatic Segmentation Method for Retinal Optical Coherence Tomography Volume Data Using Boundary Surface Enhancement

      3D Automatic Segmentation Method for Retinal Optical Coherence Tomography Volume Data Using Boundary Surface Enhancement

      With the introduction of spectral-domain optical coherence tomography (SDOCT), much larger image datasets are routinely acquired compared to what was possible using the previous generation of time-domain OCT. Thus, there is a critical need for the development of 3D segmentation methods for processing these data. We present here a novel 3D automatic segmentation method for retinal OCT volume data. Briefly, to segment a boundary surface, two OCT volume datasets are obtained by using a 3D smoothing filter and a 3D differential filter. Their linear combination is then calculated to generate new volume data with an enhanced boundary surface, where pixel ...

      Read Full Article
    22. Low-spatial-coherence broadband fiber source for speckle free imaging

      Low-spatial-coherence broadband fiber source for speckle free imaging

      We designed and demonstrate a fiber-based amplified spontaneous emission (ASE) source with low spatial coherence, low temporal coherence, and high power per mode. ASE is produced by optically pumping a large gain core multimode fiber while minimizing optical feedback to avoid lasing. The fiber ASE source provides 270 mW of continuous wave emission, centered at λ=1055 nm with a full-width half-maximum bandwidth of 74 nm. The emission is distributed among as many as ~70 spatial modes, enabling efficient speckle suppression when combined with spectral compounding. Finally, we demonstrate speckle-free full field imaging using the fiber ASE source. The fiber ASE ...

      Read Full Article
      Mentions: Michael A. Choma
    23. Depth Compensated Spectral Domain Optical Coherence Tomography via Digital Compensation

      Depth Compensated Spectral Domain Optical Coherence Tomography via Digital Compensation

      Spectral Domain Optical Coherence Tomography (SD-OCT) is a well-known imaging modality which allows for \textit{in-vivo} visualization of the morphology of different biological tissues at cellular level resolutions. The overall SD-OCT imaging quality in terms of axial resolution and Signal-to-Noise Ratio (SNR) degrades with imaging depth, while the lateral resolution degrades with distance from the focal plane. This image quality degradation is due both to the design of the SD-OCT imaging system and the optical properties of the imaged object. Here, we present a novel Depth Compensated SD-OCT (DC-OCT) system that integrates a Depth Compensating Digital Signal Processing (DC-DSP) module ...

      Read Full Article
    24. Experimental Demonstration of Spectral Intensity Optical Coherence Tomography

      Experimental Demonstration of Spectral Intensity Optical Coherence Tomography

      We demonstrate experimentally quantum-inspired, spectral-domain intensity optical coherence tomography. We show that the technique allows for both axial resolution improvement and dispersion cancellation compared to conventional optical coherence tomography. The method does not involve scanning and it works with classical light sources and standard photodetectors. The measurements are in excellent agreement with the theoretical predictions. We also propose an approach that enables the elimination of potential artifacts arising from multiple interfaces

      Read Full Article
    1-24 of 52 1 2 3 »
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks