1. Articles from arxiv.org

  2. 1-24 of 116 1 2 3 4 5 »
    1. Remote scanning for ultra-large field of view in wide-field microscopy and full-field OCT

      Remote scanning for ultra-large field of view in wide-field microscopy and full-field OCT

      Imaging specimens over large scales and with a sub-micron resolution is instrumental to biomedical research. Yet, the number of pixels to form such an image usually exceeds the number of pixels provided by conventional cameras. While most microscopes are equipped with a motorized stage to displace the specimen and acquire the image tile-by-tile, we propose an alternative strategy that does not require any moving part in the sample plane. We propose to add a scanning mechanism in the detection unit of the microscope to collect sequentially different sub-areas of the field of view. Our approach, called remote scanning, is compatible ...

      Read Full Article
    2. PERCEPTUAL-ASSISTED ADVERSARIAL ADAPTATION FOR CHOROID SEGMENTATION IN OPTICAL COHERENCE TOMOGRAPHY

      PERCEPTUAL-ASSISTED ADVERSARIAL ADAPTATION FOR CHOROID SEGMENTATION IN OPTICAL COHERENCE TOMOGRAPHY

      Accurate choroid segmentation in optical coherence tomography (OCT) image is vital because the choroid thickness is a major quantitative biomarker of many ocular diseases. Deep learning has shown its superiority in the segmentation of the choroid region but subjects to the performance degeneration caused by the domain discrepancies (e.g., noise level and distribution) among datasets obtained from the OCT devices of different manufacturers. In this paper, we present an unsupervised perceptual-assisted adversarial adaptation (PAAA) framework for efficiently segmenting the choroid area by narrowing the domain discrepancies between different domains. The adversarial adaptation module in the proposed framework encourages the ...

      Read Full Article
    3. Highly-stable, multi-megahertz circular-ranging optical coherence tomography at 1.3 µm based on a chirped fiber Bragg grating

      Highly-stable, multi-megahertz circular-ranging optical coherence tomography at 1.3 µm based on a chirped fiber Bragg grating

      In Fourier-domain optical coherence tomography (OCT), the finite bandwidth of the acquisition electronics constrains the depth range and speed of the system. Circular-ranging (CR) OCT methods use optical-domain compression to surpass this limit. However, the CR-OCT system architectures of prior reports were limited by poor stability and were confined to the 1.55 µm wavelength range. In this work, we describe a novel CR-OCT architecture that is free from these limitations. To ensure stable operation, temperature sensitive optical modules within the system were replaced; the kilometer-length fiber spools used in the stretched-pulse mode-locked (SPML) laser was eliminated in favor of ...

      Read Full Article
    4. Distortion matrix concept for deep imaging in optical coherence microscopy

      Distortion matrix concept for deep imaging in optical coherence microscopy

      In optical imaging, light propagation is affected by the inhomogeneities of the medium. Sample-induced aberrations and multiple scattering can strongly degrade the image resolution and contrast. Based on a dynamic correction of the incident and/or reflected wave-fronts, adaptive optics has been employed to compensate for those aberrations. However, it mainly applies to spatiallyinvariant aberrations or to thin aberrating layers. Here, we propose a global and non-invasive approach based on the distortion matrix concept. This matrix basically connects any focusing point of the image with the distorted part of its wave-front in reflection. A time-reversal and entropy analysis of the ...

      Read Full Article
    5. Optic-Net: A Novel Convolutional Neural Network for Diagnosis of Retinal Diseases from Optical Tomography Images

      Optic-Net: A Novel Convolutional Neural Network for Diagnosis of Retinal Diseases from Optical Tomography Images

      Diagnosing different retinal diseases from Spectral Domain Optical Coherence Tomography (SD-OCT) images is a challenging task. Different automated approaches such as image processing, machine learning and deep learning algorithms have been used for early detection and diagnosis of retinal diseases. Unfortunately, these are prone to error and computational inefficiency, which requires further intervention from human experts. In this paper, we propose a novel convolution neural network architecture to successfully distinguish between different degeneration of retinal layers and their underlying causes. The proposed novel architecture outperforms other classification models while addressing the issue of gradient explosion. Our approach reaches near perfect ...

      Read Full Article
    6. High signal-to-noise ratio reconstruction of low bit-depth optical coherence tomography using deep learning

      High signal-to-noise ratio reconstruction of low bit-depth optical coherence tomography using deep learning

      Reducing the bit-depth is an effective approach to lower the cost of optical coherence tomography (OCT) systems and increase the transmission efficiency in data acquisition and telemedicine. However, a low bit-depth will lead to the degeneration of the detection sensitivity thus reduce the signal-to-noise ratio (SNR) of OCT images. In this paper, we propose to use deep learning for the reconstruction of the high SNR OCT images from the low bit-depth acquisition. Its feasibility was preliminarily evaluated by applying the proposed method to the quantized 3 ∼ 8-bit data from native 12-bit interference fringes. We employed a pixel-to-pixel generative adversarial network ...

      Read Full Article
    7. DeshadowGAN: A Deep Learning Approach to Remove Shadows from Optical Coherence Tomography Images

      DeshadowGAN: A Deep Learning Approach to Remove Shadows from Optical Coherence Tomography Images

      Purpose: To remove retinal shadows from optical coherence tomography (OCT) images of the optic nerve head (ONH). Methods: 2328 OCT images acquired through the center of the ONH using a Spectralis OCT machine for both eyes of 13 subjects were used to train a generative adversarial network (GAN) using a custom loss function.Image quality was assessed qualitatively (for artifacts) and quantitatively using the intralayer contrast € a measure of shadow visibility ranging from 0 (shadow-free) to 1 (strong shadow) and compared to compensated images. Œis was computed in the Retinal Nerve Fiber Layer (RNFL), the Inner Plexiform Layer (IPL), the ...

      Read Full Article
    8. Transfer Learning for Automated OCTA Detection of Diabetic Retinopathy

      Transfer Learning for Automated OCTA Detection of Diabetic Retinopathy

      Purpose: To test the feasibility of using deep learning for optical coherence tomography angiography (OCTA) detection of diabetic retinopathy (DR). Methods: A deep learning convolutional neural network (CNN) architecture VGG16 was employed for this study. A transfer learning process was implemented to re-train the CNN for robust OCTA classification. In order to demonstrate the feasibility of using this method for artificial intelligence (AI) screening of DR in clinical environments, the re-trained CNN was incorporated into a custom developed GUI platform which can be readily operated by ophthalmic personnel. Results: With last nine layers re-trained, CNN architecture achieved the best performance ...

      Read Full Article
      Mentions: Xincheng Yao
    9. Resolution enhancement in low transverse sampling optical coherence tomography angiography using deep learning

      Resolution enhancement in low transverse sampling optical coherence tomography angiography using deep learning

      Optical coherence tomography angiography (OCTA) requires high transverse sampling rates for visualizing retinal and choroidal capillaries, which impedes the popularization of the OCTA technique due to the high cost of speedy acquisition systems. On the other hand, current wide-field OCTA using low transverse sampling causes the underestimation of vascular biomarkers in quantitative analysis. In this paper, we propose to use deep learning to repair the resolution degeneration induced by the low transverse sampling. We conducted preliminary experiments on converting the centrally cropped 3 × 3 mm2 field of view (FOV) of the 8 × 8 mm2 foveal OCTA images (a sampling rate ...

      Read Full Article
    10. An amplified-target loss approach for photoreceptor layer segmentation in pathological OCT scans

      An amplified-target loss approach for photoreceptor layer segmentation in pathological OCT scans

      Segmenting anatomical structures such as the photoreceptor layer in retinal optical coherence tomography (OCT) scans is challenging in pathological scenarios. Supervised deep learning models trained with standard loss functions are usually able to characterize only the most common disease appeareance from a training set, resulting in suboptimal performance and poor generalization when dealing with unseen lesions. In this paper we propose to overcome this limitation by means of an augmented target loss function framework. We introduce a novel amplified-target loss that explicitly penalizes errors within the central area of the input images, based on the observation that most of the ...

      Read Full Article
    11. Inference of visual field test performance from OCT volumes using deep learning

      Inference of visual field test performance from OCT volumes using deep learning

      Visual field tests (VFT) are pivotal for glaucoma diagnosis and conducted regularly to monitor disease progression. Here we address the question to what degree aggregate VFT measurements such as Visual Field Index (VFI) and Mean Deviation (MD) can be inferred from Optical Coherence Tomography (OCT) scans of the Optic Nerve Head (ONH) or the macula. Accurate inference of VFT measurements from OCT could reduce examination time and cost. We propose a novel 3D Convolutional Neural Network (CNN) for this task and compare its accuracy with classical machine learning (ML) algorithms trained on common, segmentation-based OCT, features employed for glaucoma diagnostics ...

      Read Full Article
    12. A model for full-field optical coherence tomography in scattering media

      A model for full-field optical coherence tomography in scattering media

      We develop a model of full-field optical coherence tomography (FF-OCT) that includes a description of partial temporal and spatial coherence, together with a mean-field scattering theory going beyond the Born approximation. Based on explicit expressions of the FF-OCT signal, we discuss essential features of FF-OCT imaging, such as the influence of partial coherence on the optical transfer function, and on the decay of the signal with depth that is captured by the model. We derive the conditions under which the spatially averaged signal exhibits a pure exponential decay with depth, providing a clear frame for the use of the Beer-Lambert ...

      Read Full Article
    13. Unifying Structure Analysis and Surrogate-driven Function Regression for Glaucoma OCT Image Screening

      Unifying Structure Analysis and Surrogate-driven Function Regression for Glaucoma OCT Image Screening

      Optical Coherence Tomography (OCT) imaging plays an important role in glaucoma diagnosis in clinical practice. Early detection and timely treatment can prevent glaucoma patients from permanent vision loss. However, only a dearth of automated methods has been developed based on OCT images for glaucoma study. In this paper, we present a novel framework to effectively classify glaucoma OCT images from normal ones. A semi-supervised learning strategy with smoothness assumption is applied for surrogate assignment of missing function regression labels. Besides, the proposed multi-task learning network is capable of exploring the structure and function relationship from the OCT image and visual ...

      Read Full Article
    14. Investigation of longitudinal spatial coherence for electromagnetic optical fields

      Investigation of longitudinal spatial coherence for electromagnetic optical fields

      For light fields, the coherence in longitudinal direction is governed by both the frequency spectra and angular spectra they possess. In this work, we develop and report a theoretical formulation to demonstrate the effect of the angular spectra of electromagnetic light fields in quantifying their longitudinal spatial coherence. The experimental results obtained by measuring the electromagnetic longitudinal spatial coherence and degree of cross-polarization of uniformly polarized light fields for different angular spectra validate the theoretical findings.

      Read Full Article
    15. Disease classification of macular Optical Coherence Tomography scans using deep learning software: validation on independent, multi-centre data

      Disease classification of macular Optical Coherence Tomography scans using deep learning software: validation on independent, multi-centre data

      Purpose: To evaluate Pegasus-OCT, a clinical decision support software for the identification of features of retinal disease from macula OCT scans, across heterogenous populations involving varying patient demographics, device manufacturers, acquisition sites and operators. Methods: 5,588 normal and anomalous macular OCT volumes (162,721 B-scans), acquired at independent centres in five countries, were processed using the software. Results were evaluated against ground truth provided by the dataset owners. Results: Pegasus-OCT performed with AUROCs of at least 98% for all datasets in the detection of general macular anomalies. For scans of sufficient quality, the AUROCs for general AMD and DME ...

      Read Full Article
    16. Multiclass segmentation as multitask learning for drusen segmentation in retinal optical coherence tomography

      Multiclass segmentation as multitask learning for drusen segmentation in retinal optical coherence tomography

      Automated drusen segmentation in retinal optical coherence tomography (OCT) scans is relevant for understanding age-related macular degeneration (AMD) risk and progression. This task is usually performed by segmenting the top/bottom anatomical interfaces that define drusen, the outer boundary of the retinal pigment epithelium (OBRPE) and the Bruch's membrane (BM), respectively. In this paper we propose a novel multi-decoder architecture that tackles drusen segmentation as a multitask problem. Instead of training a multiclass model for OBRPE/BM segmentation, we use one decoder per target class and an extra one aiming for the area between the layers. We also introduce ...

      Read Full Article
    17. Chalcogenide-glass polarization-maintaining photonic crystal fiber for mid-infrared supercontinuum generation

      Chalcogenide-glass polarization-maintaining photonic crystal fiber for mid-infrared supercontinuum generation

      In this paper, we report the design and fabrication of a highly birefringent polarization-maintaining photonic crystal fiber (PM-PCF) made from chalcogenide glass, and its application to linearly-polarized supercontinuum (SC) generation in the mid-infrared region. The fiber was drawn using the casting method from As38Se62 glass which features a transmission window from 2 to 10 µm and a high nonlinear index of 1.13×10-17 m2 /W. It has a zero-dispersion wavelength around 4.5 µm and, at this wavelength, a large birefringence of 6×10-4 and consequently strong polarization maintaining properties are expected. Using this fiber, we experimentally demonstrate supercontinuum ...

      Read Full Article
    18. Supervised machine learning based multi-task artificial intelligence classification of retinopathies

      Supervised machine learning based multi-task artificial intelligence classification of retinopathies

      Artificial intelligence (AI) classification holds promise as a novel and affordable screening tool for clinical management of ocular diseases. Rural and underserved areas, which suffer from lack of access to experienced ophthalmologists may particularly benefit from this technology. Quantitative optical coherence tomography angiography (OCTA) imaging provides excellent capability to identify subtle vascular distortions, which are useful for classifying retinovascular diseases. However, application of AI for differentiation and classification of multiple eye diseases is not yet established. In this study, we demonstrate supervised machine learning based multi-task OCTA classification. We sought 1) to differentiate normal from diseased ocular conditions, 2) to ...

      Read Full Article
      Mentions: Xincheng Yao
    19. Influence of laser spot size at diffuser plane on the longitudinal spatial coherence function of optical coherence microscopy system

      Influence of laser spot size at diffuser plane on the longitudinal spatial coherence function of optical coherence microscopy system

      Coherence properties and wavelength of light sources are indispensable for optical coherence microscopy/tomography (OCM/T) as they greatly influence the signal to noise ratio, axial resolution, and penetration depth of the system. In the present letter, we investigated the longitudinal spatial coherence properties of pseudo/thermal light source (PTS) as a function of spot size at the diffuser plane, which is controlled by translating microscope objective lens towards or away from the diffuser plane. The axial resolution of PTS is found to be maximum ~ 13 µm for the beam spot size of 3.5 mm at the diffuser plane ...

      Read Full Article
    20. Refractive index measurements of multicellular tumour spheroids using optical coherence tomography: dependence on growth phase and size

      Refractive index measurements of multicellular tumour spheroids using optical coherence tomography: dependence on growth phase and size

      Knowledge of optical properties, such as the refractive index (RI), of biological tissues is important in optical imaging, as they influence the distribution and propagation of light in tissue. To accurately study the response of cancerous cells to drugs, optimised imaging protocols are required. This study uses a simple custom-built spectral domain optical coherence tomography (OCT) system to conduct RI measurements of multicellular spheroids, three-dimensional in-vitro culture systems, of the cell line HCT116. The spheroid RIs are compared to study the effect of growth time. To improve confocal microscopy imaging protocols, two immersion media (glycerol and ScaleView-A2) matching the spheroid ...

      Read Full Article
    21. Semantic denoising autoencoders for retinal optical coherence tomography

      Semantic denoising autoencoders for retinal optical coherence tomography

      Noise in speckle-prone optical coherence tomography tends to obfuscate important details necessary for medical diagnosis. In this paper, a denoising approach that preserves disease characteristics on retinal optical coherence tomography images in ophthalmology is presented. By combining a deep convolutional autoencoder with a priorly trained ResNet image classifier as regularizer, the perceptibility of delicate details is encouraged and only information-less background noise is filtered out. With our approach, higher peak signal-to-noise ratios with PSNR = 31.2 dB and higher classification accuracy of ACC = 85.0 % can be achieved for denoised images compared to state-of-the-art denoising with PSNR = 29.4 dB ...

      Read Full Article
    22. A non-invasive investigation of Egyptian faience using a long wavelength optical coherence tomography (OCT) at 2um

      A non-invasive investigation of Egyptian faience using a long wavelength optical coherence tomography (OCT) at 2um

      Egyptian faience is a non-clay ceramic semi-transparent material, formed of a quartz core and alkalilime glaze with some cases exhibiting an interaction layer between them. Several possible glazing methods have been identified. Previous investigations have tried to identify the glazing technique by using the microstructure images obtained from polished sections using scanning electron microscope (SEM). Such techniques require sampling which is not feasible on museum collections. Optical Coherence Tomography (OCT) is a non-invasive 3D imaging technique, that produces virtual crosssections of transparent and semi-transparent materials. Liang et al. (2012a) investigated the feasibility of using OCT to non-invasively investigate microstructures of ...

      Read Full Article
      Mentions: Haida Liang
    23. A RESNET-BASED UNIVERSAL METHOD FOR SPECKLE REDUCTION IN OPTICAL COHERENCE TOMOGRAPHY IMAGES

      A RESNET-BASED UNIVERSAL METHOD FOR SPECKLE REDUCTION IN OPTICAL COHERENCE TOMOGRAPHY IMAGES

      In this work we propose a ResNet-based universal method for speckle reduction in optical coherence tomography (OCT) images. The proposed model contains 3 main modules: Convolution-BN-ReLU, Branch and Residual module. Unlike traditional algorithms, the model can learn from training data instead of selecting parameters manually such as noise level. Application of this proposed method to the OCT images shows a more than 22 dB signal-to-noise ratio improvement in speckle noise reduction with minimal structure blurring. The proposed method provides strong generalization ability and can process noisy other types of OCT images without retraining. It outperforms other filtering methods in suppressing ...

      Read Full Article
    24. Are nuclei in stratified squamous epithelium high scattering or low scattering?

      Are nuclei in stratified squamous epithelium high scattering or low scattering?

      Imaging nuclei of keratinocytes in the stratified squamous epithelium has been a subject of intense research since nucleus associated cellular atypia is the key criteria for the screening and diagnosis of epithelial cancers and their precursors. However, keratinocyte nuclei have been reported to be either low scattering or high scattering, so that these inconsistent reports might have led to misinterpretations of optical images, and more importantly, hindered the establishment of optical diagnostic criteria. We disclose that they are generally low scattering in the core using Micro-optical coherence tomography (µOCT) of 1.28-µm axial resolution in vivo; those previously reported ...

      Read Full Article
    1-24 of 116 1 2 3 4 5 »
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks