1. Articles from arxiv.org

  2. 1-24 of 138 1 2 3 4 5 6 »
    1. Swept-source optical coherence tomography by off-axis Fresnel transform digital holography with an output throughput of 10 Giga voxels per second in real-time

      Swept-source optical coherence tomography by off-axis Fresnel transform digital holography with an output throughput of 10 Giga voxels per second in real-time

      We demonstrate swept-source optical coherence tomography in real-time by high throughput digital Fresnel hologram rendering from optically-acquired interferograms with a high-speed camera. The interferogram stream is spatially rescaled with respect to wavelength to compensate for fieldof-view dilation inherent to discrete Fresnel transformation. Holograms are calculated from an input stream of 16-bit, 1024-by-1024-pixel interferograms recorded at up to 512 frames per second with a digital camera. All calculations are performed by a NVIDIA TITAN Xp graphics card on single-precision floating-point complex-valued arrays (32-bit per quadrature). It allows sustained computation of 1024-by-1024-by-256-voxel volumes at 10 billion voxel/s, from which three perpendicular ...

      Read Full Article
    2. Resolution enhancement and realistic speckle recovery with generative adversarial modeling of micro-optical coherence tomography

      Resolution enhancement and realistic speckle recovery with generative adversarial modeling of micro-optical coherence tomography

      A resolution enhancement technique for optical coherence tomography (OCT), based on Generative Adversarial Networks (GANs), was developed and investigated. GANs have been previously used for resolution enhancement of photography and optical microscopy images. We have adapted and improved this technique for OCT image generation. Conditional GANs (cGANs) were trained on a novel set of ultrahigh resolution spectral domain OCT volumes, termed micro-OCT, as the high-resolution ground truth (∼1 µm isotropic resolution). The ground truth was paired with a low-resolution image obtained by synthetically degrading resolution 4x in one of (1-D) or both axial and lateral axes (2-D). Cross-sectional image (B-scan ...

      Read Full Article
    3. Coronary Artery Segmentation from Intravascular Optical Coherence Tomography Using Deep Capsules

      Coronary Artery Segmentation from Intravascular Optical Coherence Tomography Using Deep Capsules

      The segmentation and analysis of coronary arteries from intravascular optical coherence tomography (IVOCT) is an important aspect of diagnosing and managing coronary artery disease. However, automated, robust IVOCT image analysis tools are lacking. Current image processing methods are hindered by the time needed to generate these expert-labelled datasets and also the potential for bias during the analysis. Here we present a new deep learning method based on capsules to automatically produce lumen segmentations, built using a large IVOCT dataset of 12,011 images with ground-truth segmentations. This dataset contains images with both blood and light artefacts (22.8%), as well ...

      Read Full Article
    4. A Semi-Automatic Software for Segmentation and Feature Extraction from Optical Coherence Tomography Images (Semi SFE)

      A Semi-Automatic Software for Segmentation and Feature Extraction from Optical Coherence Tomography Images (Semi SFE)

      The Ophthalmology Science has recently witnessed marked progress due to the advent of divergent imaging techniques, especially Optical Coherence Tomography which has caught many physicians’ attention for being exact, rapid, non-invasive and low-cost. In this paper, we wish to solve the difficulties associated with OCT image segmentation by offering a handy software written in the MATLAB [1] App Designer environment which helps researchers and clinicians to easily segment the images, save the numerical outcomes and send them for proper analysis. Serving an unambiguous user interface along with a unified platform in which all necessary functions have been incorporated graphically has ...

      Read Full Article
    5. Optical Incoherence Tomography: a method to generate tomographic retinal cross-sections with non-interferometric imaging systems

      Optical Incoherence Tomography: a method to generate tomographic retinal cross-sections with non-interferometric imaging systems

      Optical tomographic cross-sectional images of biological samples were made possible by interferometric imaging techniques such as Optical Coherence Tomography (OCT) [1, 2, 3]. Owing to its unprecedented view of the sample, OCT has become a gold standard, namely for human retinal imaging in the clinical environment. In this Letter, we present Optical Incoherence Tomography (OIT): a completely digital method extending the possibility to generate tomographic retinal cross-sections to non-interferometric imaging systems such as en-face AO-ophthalmoscopes [4, 5]. We demonstrate that OIT can be applied to different imaging modalities using back-scattered and multiply-scattered light including systems without inherent optical sectioning. We ...

      Read Full Article
    6. Dynamic contrast in scanning microscopic OCT

      Dynamic contrast in scanning microscopic OCT

      While optical coherence tomography (OCT) provides a resolution down to 1 micrometer it has difficulties to visualize cellular structures due to a lack of scattering contrast. By evaluating signal fluctuations, a significant contrast enhancement was demonstrated using time-domain full-field OCT (FF-OCT), which makes cellular and subcellular structures visible. The putative cause of the dynamic OCT signal is ATP-dependent motion of cellular structures in a sub-micrometer range, which provides histology-like contrast. Here we demonstrate dynamic contrast with a scanning frequency-domain OCT (FD-OCT). Given the inherent sectional imaging geometry, scanning FD-OCT provides depth-resolved images across tissue layers, a perspective known from histopathology ...

      Read Full Article
    7. Towards Label-Free 3D Segmentation of Optical Coherence Tomography Images of the Optic Nerve Head Using Deep Learning

      Towards Label-Free 3D Segmentation of Optical Coherence Tomography Images of the Optic Nerve Head Using Deep Learning

      Since the introduction of optical coherence tomography (OCT), it has been possible to study the complex 3D morphological changes of the optic nerve head (ONH) tissues that occur along with the progression of glaucoma. Although several deep learning (DL) techniques have been recently proposed for the automated extraction (segmentation) and quantification of these morphological changes, the device-specific nature and the difficulty in preparing manual segmentations (training data) limit their clinical adoption. With several new manufacturers and next-generation OCT devices entering the market, the complexity in deploying DL algorithms clinically is only increasing. To address this, we propose a DLbased 3D ...

      Read Full Article
    8. Automatic Segmentation and Visualization of Choroid in OCT with Knowledge Infused Deep Learning

      Automatic Segmentation and Visualization of Choroid in OCT with Knowledge Infused Deep Learning

      The choroid provides oxygen and nourishment to the outer retina thus is related to the pathology of various ocular diseases. Optical coherence tomography (OCT) is advantageous in visualizing and quantifying the choroid in vivo, because it does not suffer from the information contamination of the outer retina in fundus photography and scanning laser ophthalmoscopy and the resolution deficiency in ocular ultrasound. We propose a biomarker infused global-to-local network, for the choroid segmentation. It leverages the thickness of the choroid layer, which is a primary biomarker in clinic, as a constraint to improve the segmentation accuracy. We also design a global-to-local ...

      Read Full Article
    9. Reconstructing the Optical Parameters of a Layered Medium with Optical Coherence Elastography

      Reconstructing the Optical Parameters of a Layered Medium with Optical Coherence Elastography

      In this work we consider the inverse problem of reconstructing the optical properties of a layered medium from an elastography measurement where optical coherence tomography is used as the imaging method. We hereby model the sample as a linear dielectric medium so that the imaging parameter is given by its electric susceptibility, which is a frequencyand depth-dependent parameter. Additionally to the layered structure (assumed to be valid at least in the small illuminated region), we allow for small scatterers which we consider to be randomly distributed, a situation which seems more realistic compared to purely homogeneous layers. We then show ...

      Read Full Article
    10. Toward Autonomous Robotic Micro-Suturing using Optical Coherence Tomography Calibration and Path Planning

      Toward Autonomous Robotic Micro-Suturing using Optical Coherence Tomography Calibration and Path Planning

      Robotic automation has the potential to assist human surgeons in performing suturing tasks in microsurgery, and in order to do so a robot must be able to guide a needle with sub-millimeter precision through soft tissue. This paper presents a robotic suturing system that uses 3D optical coherence tomography (OCT) system for imaging feedback. Calibration of the robot-OCT and robot-needle transforms, wound detection, keypoint identification, and path planning are all performed automatically. The calibration method handles pose uncertainty when the needle is grasped using a variant of iterative closest points. The path planner uses the identified wound shape to calculate ...

      Read Full Article
    11. Real-time, non-contact, cellular imaging and angiography of human cornea and limbus with common-path Full-field/SD OCT

      Real-time, non-contact, cellular imaging and angiography of human cornea and limbus with common-path Full-field/SD OCT

      In today’s clinics, a cellular-resolution view of the cornea can be achieved only with an in vivo confocal microscope (IVCM) in contact with the eye. Here, we present a common-path Full-field/Spectral-domain OCT microscope (FF/SD OCT), which, for the first time, enables cell-detail imaging of the entire ocular surface (central and peripheral cornea, limbus, sclera, tear film) without contact and in real time. The device, that has been successfully tested in human subjects, is now ready for direct implementation in clinical research. Real-time performance is achieved through rapid axial eye tracking and simultaneous defocusing correction. Images, extracted from ...

      Read Full Article
    12. Segmentation of Retinal Low-Cost Optical Coherence Tomography Images using Deep Learning

      Segmentation of Retinal Low-Cost Optical Coherence Tomography Images using Deep Learning

      The treatment of age-related macular degeneration (AMD) requires continuous eye exams using optical coherence tomography (OCT). The need for treatment is determined by the presence or change of disease-specific OCTbased biomarkers. Therefore, the monitoring frequency has a significant influence on the success of AMD therapy. However, the monitoring frequency of current treatment schemes is not individually adapted to the patient and therefore often insufficient. While a higher monitoring frequency would have a positive effect on the success of treatment, in practice it can only be achieved with a home monitoring solution. One of the key requirements of a home monitoring ...

      Read Full Article
    13. Curved-Full-Field OCT for high-resolution imaging of living human retina over a large field-of-view

      Curved-Full-Field OCT for high-resolution imaging of living human retina over a large field-of-view

      Allying high-resolution with a large field-of-view (FOV) is of great importance in the fields of biology and medicine [1, 2, 3], but particularly challenging when imaging non-flat living samples such as the human retina. Indeed, high-resolution is normally achieved with adaptive optics (AO) and scanning methods, which considerably reduce the useful FOV and increase the system complexity. An alternative technique is time-domain Full-Field Optical Coherence Tomography (FF-OCT) [4, 5], which has already shown its potential for in-vivo high-resolution retinal imaging [6]. Here, we introduce curved-field FF-OCT, capable of matching the coherence gate geometry to the sample curvature, thus achieving a ...

      Read Full Article
    14. HIGH-SPEED MARKERLESS TISSUE MOTION TRACKING USING VOLUMETRIC OPTICAL COHERENCE TOMOGRAPHY IMAGES

      HIGH-SPEED MARKERLESS TISSUE MOTION TRACKING USING VOLUMETRIC OPTICAL COHERENCE TOMOGRAPHY IMAGES

      Modern optical coherence tomography (OCT) devices provide volumetric images with micrometer-scale spatial resolution and a temporal resolution beyond video rate. In this work, we analyze an OCT-based prototypical tracking system which processes 831 volumes per second, estimates translational motion, and automatically adjusts the field-of-view, which has a size of few millimeters, to follow a sample even along larger distances. The adjustment is realized by two galvo mirrors and a motorized reference arm, such that no mechanical movement of the scanning setup is necessary. Without requiring a marker or any other knowledge about the sample, we demonstrate that reliable tracking of ...

      Read Full Article
    15. Deep OCT Angiography Image Generation for Motion Artifact Suppression

      Deep OCT Angiography Image Generation for Motion Artifact Suppression

      Eye movements, blinking and other motion during the acquisition of optical coherence tomography (OCT) can lead to artifacts, when processed to OCT angiography (OCTA) images. Affected scans emerge as high intensity (white) or missing (black) regions, resulting in lost information. The aim of this research is to fill these gaps using a deep generative model for OCT to OCTA image translation relying on a single intact OCT scan. Therefore, a U-Net is trained to extract the angiographic information from OCT patches. At inference, a detection algorithm finds outlier OCTA scans based on their surroundings, which are then replaced by the ...

      Read Full Article
    16. Beyond Fourier transform: break the axial resolution limit in optical coherence tomography

      Beyond Fourier transform: break the axial resolution limit in optical coherence tomography

      Optical coherence tomography (OCT) is a volumetric imaging modality that empowers the clinicians and scientists to noninvasively visualize and examine the microscopic cross-sectional architectures of biological samples. By taking advantages of the coherence gating, OCT could achieve micrometer-level axial sectioning with high sensitivity. In the past decade, substantial efforts have been made to push the axial resolution of Fourier-domain OCT (FD-OCT) further into the sub-micron regime via physically extending the system’s spectral bandwidth. Here, we would like to offer a new perspective on this problem. We argue that the coupling between the axial resolution and the spectral bandwidth in ...

      Read Full Article
    17. Automated and Network Structure Preserving Segmentation of Optical Coherence Tomography Angiograms

      Automated and Network Structure Preserving Segmentation of Optical Coherence Tomography Angiograms

      Optical coherence tomography angiography (OCTA) is a novel non-invasive imaging modality for the visualisation of microvasculature in vivo. OCTA has encountered broad adoption in retinal research. OCTA potential in the assessment of pathological conditions and the reproducibility of studies relies on the quality of the image analysis. However, automated segmentation of parafoveal OCTA images is still an open problem in the field. In this study, we generate the first open dataset of retinal parafoveal OCTA images with associated ground truth manual segmentations. Furthermore, we establish a standard for OCTA image segmentation by surveying a broad range of state-of-the-art vessel enhancement ...

      Read Full Article
    18. BIONET: INFUSING BIOMARKER PRIOR INTO GLOBAL-TO-LOCAL NETWORK FOR CHOROID SEGMENTATION IN OPTICAL COHERENCE TOMOGRAPHY IMAGES

      BIONET: INFUSING BIOMARKER PRIOR INTO GLOBAL-TO-LOCAL NETWORK FOR CHOROID SEGMENTATION IN OPTICAL COHERENCE TOMOGRAPHY IMAGES

      Choroid is the vascular layer of the eye, which is directly related to the incidence and severity of many ocular diseases. Optical Coherence Tomography (OCT) is capable of imaging both the cross-sectional view of retina and choroid, but the segmentation of the choroid region is challenging because of the fuzzy choroid-sclera interface (CSI). In this paper, we propose a biomarker infused global-to-local network (BioNet) for choroid segmentation, which segments the choroid with higher credibility and robustness. Firstly, our method trains a biomarker prediction network to learn the features of the biomarker. Then a global multi-layers segmentation module is applied to ...

      Read Full Article
    19. Computational aberration correction in spatiotemporal optical coherence (STOC) imaging

      Computational aberration correction in spatiotemporal optical coherence (STOC) imaging

      Spatiotemporal optical coherence (STOC) imaging is a new technique for suppressing coherent crosstalk noise in Fourier-domain full-field optical coherence tomography (FD-FF-OCT). In STOC imaging, the timevarying inhomogeneous phase masks modulate the incident light to alter the interferometric signal. Resulting interference images are then processed as in standard FDFF-OCT and averaged incoherently or coherently to produce crosstalk-free volumetric OCT images of the sample. Here, we show that coherent averaging is suitable when phase modulation is performed for both interferometer arms simultaneously. We explain the advantages of coherent over incoherent averaging. Specifically, we show that modulated signal, after coherent averaging, preserves lateral ...

      Read Full Article
    20. Cascaded Deep Neural Networks for Retinal Layer Segmentation of Optical Coherence Tomography with Fluid Presence

      Cascaded Deep Neural Networks for Retinal Layer Segmentation of Optical Coherence Tomography with Fluid Presence

      Optical coherence tomography (OCT) is a non-invasive imaging technology which can provide micrometer-resolution cross-sectional images of the inner structures of the eye. It is widely used for the diagnosis of ophthalmic diseases with retinal alteration, such as layer deformation and fluid accumulation. In this paper, a novel framework was proposed to segment retinal layers with fluid presence. The main contribution of this study is two folds: 1) we developed a cascaded network framework to incorporate the prior structural knowledge; 2) we proposed a novel deep neural network based on U-Net and fully convolutional network, termed LF-UNet. Cross validation experiments proved ...

      Read Full Article
    21. Dynamic full-field optical coherence tomography: 3D live-imaging of retinal organoids

      Dynamic full-field optical coherence tomography: 3D live-imaging of retinal organoids

      Optical coherence tomography offers astounding opportunities to image the complex structure of living tissue, but lacks functional information. We present dynamic full-field optical coherence tomography to image living human induced pluripotent stem cell-derived retinal organoids non-invasively. Colored images with an endogenous contrast linked to organelle motility are generated, with sub-micrometer spatial resolution and millisecond temporal resolution, opening an avenue to identify specific cell types in living tissue via their function.

      Read Full Article
    22. Remote scanning for ultra-large field of view in wide-field microscopy and full-field OCT

      Remote scanning for ultra-large field of view in wide-field microscopy and full-field OCT

      Imaging specimens over large scales and with a sub-micron resolution is instrumental to biomedical research. Yet, the number of pixels to form such an image usually exceeds the number of pixels provided by conventional cameras. While most microscopes are equipped with a motorized stage to displace the specimen and acquire the image tile-by-tile, we propose an alternative strategy that does not require any moving part in the sample plane. We propose to add a scanning mechanism in the detection unit of the microscope to collect sequentially different sub-areas of the field of view. Our approach, called remote scanning, is compatible ...

      Read Full Article
    23. PERCEPTUAL-ASSISTED ADVERSARIAL ADAPTATION FOR CHOROID SEGMENTATION IN OPTICAL COHERENCE TOMOGRAPHY

      PERCEPTUAL-ASSISTED ADVERSARIAL ADAPTATION FOR CHOROID SEGMENTATION IN OPTICAL COHERENCE TOMOGRAPHY

      Accurate choroid segmentation in optical coherence tomography (OCT) image is vital because the choroid thickness is a major quantitative biomarker of many ocular diseases. Deep learning has shown its superiority in the segmentation of the choroid region but subjects to the performance degeneration caused by the domain discrepancies (e.g., noise level and distribution) among datasets obtained from the OCT devices of different manufacturers. In this paper, we present an unsupervised perceptual-assisted adversarial adaptation (PAAA) framework for efficiently segmenting the choroid area by narrowing the domain discrepancies between different domains. The adversarial adaptation module in the proposed framework encourages the ...

      Read Full Article
    24. Highly-stable, multi-megahertz circular-ranging optical coherence tomography at 1.3 µm based on a chirped fiber Bragg grating

      Highly-stable, multi-megahertz circular-ranging optical coherence tomography at 1.3 µm based on a chirped fiber Bragg grating

      In Fourier-domain optical coherence tomography (OCT), the finite bandwidth of the acquisition electronics constrains the depth range and speed of the system. Circular-ranging (CR) OCT methods use optical-domain compression to surpass this limit. However, the CR-OCT system architectures of prior reports were limited by poor stability and were confined to the 1.55 µm wavelength range. In this work, we describe a novel CR-OCT architecture that is free from these limitations. To ensure stable operation, temperature sensitive optical modules within the system were replaced; the kilometer-length fiber spools used in the stretched-pulse mode-locked (SPML) laser was eliminated in favor of ...

      Read Full Article
    1-24 of 138 1 2 3 4 5 6 »
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks