    1. Reproducibility of Retinal Thickness Measurements across Spectral-Domain Optical Coherence Tomography Devices using Iowa Reference Algorithm

      Reproducibility of Retinal Thickness Measurements across Spectral-Domain Optical Coherence Tomography Devices using Iowa Reference Algorithm

      PURPOSE: Establishing and obtaining consistent quantitative indices of retinal thickness from a variety of clinically used Spectral-Domain Optical Coherence Tomography scanners. DESIGN: Retinal images from five Spectral-Domain Optical Coherence Tomography scanners were used to determine total retinal thickness with scanner-specific correction factors establishing consistency of thickness measurement across devices. PARTICIPANTS: 55 Fovea-centered Spectral-Domain Optical Coherence Tomography volumes from eleven subjects were analyzed, obtained from Cirrus HD-OCT, RS-3000, Heidelberg Spectralis, RTVue and Topcon2000, seven subjects with retinal diseases and four normal controls. METHOD: The Iowa Reference Algorithm measured total retinal thickness. Nonlinear model of total retinal thickness measurement comparisons was derived ...

      Read Full Article
    2. Collaborative effects of wavefront shaping and optical clearing agent in optical coherence tomography

      Collaborative effects of wavefront shaping and optical clearing agent in optical coherence tomography

      Developing a deep-tissue imaging tool with good optical resolution is one of the important goals of biophotonics because medical diagnosis usually requires imaging of fine details of whole tissue structures. Optical coherence tomography (OCT) is an extensively developed imaging tool for biological tissues. Based on low-coherence interferometry, OCT provides micrometer scale resolution and enables non-invasive high-speed imaging1 . OCT is widely used in ophthalmology because it can fully access retina, choroid and sclera layers of human eyes in vivo. 2, 3 OCT has a higher penetration depth of 12 mm compared to other optical imaging modalities such as multi-photon microscopy ...

      Read Full Article
    3. A signal separation technique for sub-cellular imaging using dynamic optical coherence tomography

      A signal separation technique for sub-cellular imaging using dynamic optical coherence tomography

      This paper aims at imaging the dynamics of metabolic activity of cells. Using dynamic optical coherence tomography, we introduce a new multiparticle dynamical model to simulate the movements of the collagen and the cell metabolic activity and develop an efficient signal separation technique for sub-cellular imaging. We perform a singular-value decomposition of the dynamic optical images to isolate the intensity of the metabolic activity. We prove that the largest eigenvalue of the associated Casorati matrix corresponds to the collagen. We present several numerical simulations to illustrate and validate our approach.

      Read Full Article
    4. Optical teardown of a Kindle Paperwhite display by OCT.

      Optical teardown of a Kindle Paperwhite display by OCT.

      An optical teardown, or reverse engineering, of an Amazon Kindle Paperwhite electrophoretic display was performed by Optical Coherence Tomography at 1060 nm. The display incorporates an optical diffuser, lightguide and scattering layers for white light illumination, capacitive touch sensing, and an electrophoretic display. All these layers can be imaged by OCT as well as the thin film transistor array on the back side for driving the pixels. Phase sensitive OCT is used to measure motion of the pigment particles as the display changes between black and white.

      Read Full Article
    5. Classical realization of dispersion-canceled, artifact-free, and background-free optical coherence tomography

      Classical realization of dispersion-canceled, artifact-free, and background-free optical coherence tomography

      Quantum-optical coherence tomography (Q-OCT) provides a dispersion-canceled axial-imaging method, but its practical use is limited by the weakness of the light source and by artifacts in the images. A recent study using chirped-pulse interferometry (CPI) has demonstrated dispersion-canceled and artifact-free OCT with a classical system; however, unwanted background signals still remain after removing the artifacts. Here, we propose a classical optical method that realizes dispersion-canceled, artifact-free, and background-free OCT. We employ a time-reversed system for Q-OCT with transform-limited input laser pulses to achieve dispersion-canceled OCT with a classical system. We have also introduced a subtraction method to remove artifacts and ...

      Read Full Article
    6. Inverse Problems of Combined Photoacoustic and Optical Coherence Tomography

      Inverse Problems of Combined Photoacoustic and Optical Coherence Tomography

      Optical coherence tomography (OCT) and photoacoustic tomography (PAT) are emerging non-invasive biological and medical imaging techniques. It is a recent trend in experimental science to design experiments that perform PAT and OCT imaging at once. In this paper we present a mathematical model describing the dual experiment. Since OCT is mathematically modelled by Maxwell's equations or some simplifications of it, whereas the light propagation in quantitative photoacoustics is modelled by (simplifications of) the radiative transfer equation, the first step in the derivation of a mathematical model of the dual experiment is to obtain a unified mathematical description, which in ...

      Read Full Article
    7. Dynamic full field optical coherence tomography: subcellular metabolic contrast revealed in tissues by temporal analysis of interferometric signals

      Dynamic full field optical coherence tomography: subcellular metabolic contrast revealed in tissues by temporal analysis of interferometric signals

      We developed a new endogenous approach to reveal subcellular metabolic contrast in fresh ex vivo tissues taking advantage of the time dependence of the full field optical coherence tomography interferometric signals. This method reveals signals linked with local activity of the endogenous scattering elements which can reveal cells where other imaging techniques fail or need exogenous contrast agents. We benefit from the micrometric transverse resolution of full field OCT to image intracellular features. We used this time dependence to identify different dynamics at the millisecond scale on a wide range of organs in normal or pathological conditions.

      Read Full Article
    8. Smart optical coherence tomography for ultra-deep imaging through highly scattering media

      Smart optical coherence tomography for ultra-deep imaging through highly scattering media

      Multiple scattering of waves in disordered media is a nightmare whether it be for detection or imaging purposes. The best approach so far to get rid of multiple scattering is optical coherence tomography. It basically combines confocal microscopy and coherence time-gating to discriminate ballistic photons from a predominant multiple scattering background. Nevertheless, the imaging depth range remains limited to 1 mm at best in human soft tissues. Here we propose a matrix approach of optical imaging to push back this fundamental limit. By combining a matrix discrimination of ballistic waves and iterative time-reversal, we show both theoretically and experimentally an ...

      Read Full Article
    9. In vivo deep tissue imaging using wavefront shaping optical coherence tomography

      In vivo deep tissue imaging using wavefront shaping optical coherence tomography

      Multiple light scattering in tissue limits the penetration of optical coherence tomography (OCT) imaging. Here, we present in-vivo OCT imaging of a live mouse using wavefront shaping to enhance the penetration depth. A digital micro-mirror device (DMD) was used in a spectral-domain OCT system for complex wavefront shaping of an incident beam which resulted in the optimal delivery of light energy into deep tissue. Ex-vivo imaging of chicken breasts and mouse ear tissues showed enhancements in the strength of the image signals and the penetration depth, and in-vivo imaging of the tail of a live mouse provided a multilayered structure ...

      Read Full Article
    10. High-speed optical correlation-domain reflectometry without using acousto-optic modulator

      High-speed optical correlation-domain reflectometry without using acousto-optic modulator

      To achieve a distributed reflectivity measurement along an optical fiber, we develop a simplified cost-effective configuration of optical correlation- (or coherence-) domain reflectometry based on a synthesized optical coherence function by sinusoidal modulation. By excluding conventional optical heterodyne detection (practically, without using an acoustooptic modulator) and by exploiting the foot of the Fresnel reflection spectrum, the electrical bandwidth required for signal processing is lowered down to several megahertz. We evaluate the basic system performance and demonstrate its high-speed operation (10 ms for one scan) by tracking a moving reflection point in real time.

      Read Full Article
    11. 3D Automatic Segmentation Method for Retinal Optical Coherence Tomography Volume Data Using Boundary Surface Enhancement

      3D Automatic Segmentation Method for Retinal Optical Coherence Tomography Volume Data Using Boundary Surface Enhancement

      With the introduction of spectral-domain optical coherence tomography (SDOCT), much larger image datasets are routinely acquired compared to what was possible using the previous generation of time-domain OCT. Thus, there is a critical need for the development of 3D segmentation methods for processing these data. We present here a novel 3D automatic segmentation method for retinal OCT volume data. Briefly, to segment a boundary surface, two OCT volume datasets are obtained by using a 3D smoothing filter and a 3D differential filter. Their linear combination is then calculated to generate new volume data with an enhanced boundary surface, where pixel ...

      Read Full Article
    12. Low-spatial-coherence broadband fiber source for speckle free imaging

      Low-spatial-coherence broadband fiber source for speckle free imaging

      We designed and demonstrate a fiber-based amplified spontaneous emission (ASE) source with low spatial coherence, low temporal coherence, and high power per mode. ASE is produced by optically pumping a large gain core multimode fiber while minimizing optical feedback to avoid lasing. The fiber ASE source provides 270 mW of continuous wave emission, centered at λ=1055 nm with a full-width half-maximum bandwidth of 74 nm. The emission is distributed among as many as ~70 spatial modes, enabling efficient speckle suppression when combined with spectral compounding. Finally, we demonstrate speckle-free full field imaging using the fiber ASE source. The fiber ASE ...

      Read Full Article
      Mentions: Michael A. Choma
    13. Depth Compensated Spectral Domain Optical Coherence Tomography via Digital Compensation

      Depth Compensated Spectral Domain Optical Coherence Tomography via Digital Compensation

      Spectral Domain Optical Coherence Tomography (SD-OCT) is a well-known imaging modality which allows for \textit{in-vivo} visualization of the morphology of different biological tissues at cellular level resolutions. The overall SD-OCT imaging quality in terms of axial resolution and Signal-to-Noise Ratio (SNR) degrades with imaging depth, while the lateral resolution degrades with distance from the focal plane. This image quality degradation is due both to the design of the SD-OCT imaging system and the optical properties of the imaged object. Here, we present a novel Depth Compensated SD-OCT (DC-OCT) system that integrates a Depth Compensating Digital Signal Processing (DC-DSP) module ...

      Read Full Article
    14. Experimental Demonstration of Spectral Intensity Optical Coherence Tomography

      Experimental Demonstration of Spectral Intensity Optical Coherence Tomography

      We demonstrate experimentally quantum-inspired, spectral-domain intensity optical coherence tomography. We show that the technique allows for both axial resolution improvement and dispersion cancellation compared to conventional optical coherence tomography. The method does not involve scanning and it works with classical light sources and standard photodetectors. The measurements are in excellent agreement with the theoretical predictions. We also propose an approach that enables the elimination of potential artifacts arising from multiple interfaces

      Read Full Article
    15. Analysis of a spinning polygon wavelength swept laser

      Analysis of a spinning polygon wavelength swept laser

      It has been known for quite some time that spinning polygon, and similar, swept lasers used in OCT favor the short to long wavelength sweep direction because of four wave mixing in the gain medium. Here we have reformulated the problem in the time domain and show experimentally and through numerical simulation that these lasers are pulsed. The emitted pulses modulate the gain medium refractive index to red shift the light. Instead of new wavelengths being built up slowly from spontaneous emission, each pulse hops to a longer wavelength by nonlinear means, tracking the tunable filter. This allows high speed ...

      Read Full Article
    16. SPARSE AND LOW RANK DECOMPOSITION BASED BATCH IMAGE ALIGNMENT FOR SPECKLE REDUCTION OF RETINAL OCT IMAGES

      SPARSE AND LOW RANK DECOMPOSITION BASED BATCH IMAGE ALIGNMENT FOR SPECKLE REDUCTION OF RETINAL OCT IMAGES

      Optical Coherence Tomography (OCT) in an emerging technique in the field of biomedical imaging, with applications in ophthalmology, dermatology, coronary imaging etc. Due to the underlying physics, OCT images usually suffer from a granular pattern, called speckle noise, which restricts the process of interpretation. Here, a sparse and low rank decomposition based method is used for speckle reduction in retinal OCT images. In this technique, at first, several OCT images of the same location (to some extent) are acquired and stacked together. The next step is the batch alignment of the images using a sparse and low-rank decomposition based technique ...

      Read Full Article
    17. Simultaneous measurement of localized diffusion and flow using optical coherence tomography

      Simultaneous measurement of localized diffusion and flow using optical coherence tomography

      We report on the simultaneous and localized measurements of the diffusion coefficient and flow velocity based on the normalized autocorrelation function using optical coherence tomography (OCT). Our results on a flowing solution of polystyrene spheres show that the flow velocity and the diffusion coefficient can be reliably estimated in a regime determined by the sample diffusivity, the local flow velocity, and the Gaussian beam waist. We experimentally show that a smaller beam waist results in an improvement of the velocity sensitivity at cost of the precision and accuracy of the estimation of the diffusion coefficient. Further, we show that the ...

      Read Full Article
    18. Hybrid M-mode-like OCT imaging of 3D microvasculature in vivo using reference-free processing of complex-valued B-scans

      Hybrid M-mode-like OCT imaging of 3D  microvasculature in vivo using reference-free  processing of complex-valued B-scans

      We propose a novel OCT-based method for visualizing microvasculature in 3D using reference-free processing of individual complex-valued B-scans with highly overlapped A-scans. In the lateral direction of such a B-scan, the amplitude and phase of speckles corresponding to vessel regions exhibit faster variability, and thus can be detected without comparison with other B-scans recorded in the same plane. This method combines elements of several existing OCT angiographic approaches, and exhibits: (i) enhanced robustness with respect to bulk tissue motion with frequencies up to tens of Hz; (ii) resolution of microcirculation images equal to that of structural images and (iii) possibility ...

      Read Full Article
    19. State-of-the-Art in Retinal Optical Coherence Tomography Image Analysis

      State-of-the-Art in Retinal Optical Coherence Tomography Image Analysis

      Optical Coherence Tomography (OCT) is one of the most emerging imaging modalities that has been used widely in the eld of biomedical imaging. From its emergence in 1990's, plenty of hardware and software improvements have been made. Its applications range from ophthalmology to dermatology to coronary imaging etc. Here, the focus is on applications of OCT in ophthalmology and retinal imaging. OCT is able to non- invasively produce cross-sectional volume images of the tissues which are further used for analysis of the tissue structure and its properties. Due to the underlying physics, OCT images usually su er from a ...

      Read Full Article
    20. Low-spatial coherence electrically-pumped semiconductor laser for speckle-free full-field imaging

      Low-spatial coherence electrically-pumped semiconductor laser for speckle-free full-field imaging

      The spatial coherence of laser sources has limited their application to parallel imaging and projection due to coherent artifacts, such as speckle. In contrast, traditional incoherent light sources, such as thermal sources or light emitting diodes (LEDs), provide relatively low power per independent spatial mode. Here, we present a chip-scale, electrically-pumped semiconductor laser based on a novel design, demonstrating high power per mode with much lower spatial coherence than conventional laser sources. The laser resonator was fabricated with a chaotic, D-shaped cavity optimized to achieve highly multimode lasing. Lasing occurs simultaneously and independently in ~1000 modes, and hence the total ...

      Read Full Article
    21. Mathematical modeling in full-field optical coherence elastography

      Mathematical modeling in full-field optical coherence elastography

      We provide a mathematical analysis of and a numerical framework for full- field optical coherence elastography, which has unique features including micron-scale resolution, real-time processing, and non-invasive imaging. We develop a novel al- gorithm for transforming volumetric optical images before and after the mechanical solicitation of a sample with sub-cellular resolution into quantitative shear modulus distributions. This has the potential to improve sensitivities and specificity in the biological and clinical applications of optical coherence tomography.

      Read Full Article
    22. Mathematical Modelling of Optical Coherence Tomography

      Mathematical Modelling of Optical Coherence Tomography

      In this chapter a general mathematical model of Optical Coherence Tomography (OCT) is presented on the basis of the electromagnetic theory. OCT produces high resolution images of the inner structure of biological tissues. Images are obtained by measuring the time delay and the intensity of the backscattered light from the sample considering also the coherence properties of light. The scattering problem is considered for a weakly scattering medium located far enough from the detector. The inverse problem is to reconstruct the susceptibility of the medium given the measurements for di erent positions of the mirror. Di erent approaches are addressed ...

      Read Full Article
    23. A Quantum Field Approach for Advancing Optical Coherence Tomography Part I: First Order Correlations, Single Photon Interference, And Quantum Noise

      A Quantum Field Approach for Advancing Optical Coherence Tomography Part I: First Order Correlations, Single Photon Interference, And Quantum Noise

      Optical coherence tomography has become an important imaging technology in cardiology and ophthalmology, with other applications under investigations. Major advances in optical coherence tomography (OCT) imaging are likely to occur through a quantum field approach to the technology. In this paper, which is the first part in a series on the topic, the quantum basis of OCT first order correlations is expressed in terms of full field quantization. Specifically first order correlations are treated as the linear sum of single photon interferences along indistinguishable paths. Photons and the electromagnetic (EM) field are described in terms of quantum harmonic oscillators. While ...

      Read Full Article
    24. Thickness Mapping of Eleven Retinal Layers in Normal Eyes Using Spectral Domain Optical Coherence Tomography

      Thickness Mapping of Eleven Retinal Layers in Normal Eyes Using Spectral Domain Optical Coherence Tomography

      Purpose. This study was conducted to determine the thickness map of eleven retinal layers in normal subjects by spectral domain optical coherence tomography (SD-OCT) and evaluate their association with sex and age. Methods. Mean regional retinal thickness of 11 retinal layers were obtained by automatic three-dimensional diffusion-map-based method in 112 normal eyes of 76 Iranian subjects. Results. The thickness map of central foveal area in layer 1, 3, and 4 displayed the minimum thickness (P<0.005 for all). Maximum thickness was observed in nasal to the fovea of layer 1 (P<0.001) and in a circular pattern in ...

      Read Full Article
    1-24 of 42 1 2 »
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks