1. Articles from arxiv.org

  2. 1-24 of 164 1 2 3 4 5 6 7 »
    1. Non-contact, in-vivo, functional, and structural ophthalmic imaging using multimodal photoacoustic remote sensing (PARS) microscopy and optical coherence tomography (OCT)

      Non-contact, in-vivo, functional, and structural ophthalmic imaging using multimodal photoacoustic remote sensing (PARS) microscopy and optical coherence tomography (OCT)

      Early diagnosis of ocular diseases improves the understanding of pathophysiology and helps with accurate monitoring and effective treatment. Advanced multimodal ocular imaging platforms play a crucial role in the visualization of the ocular components and provide clinicians with a valuable tool for evaluating different eye diseases. Here, for the first time, we present a non-contact, multimodal photoacoustic remote sensing (PARS) microscopy and swept-source optical coherence tomography (SS-OCT) for in-vivo functional and structural imaging of the eye. The system provides complementary imaging contrasts of optical absorption and optical scattering and is used for non-contact, in-vivo imaging of the murine eye. Results ...

      Read Full Article
    2. Speckle Statistics of Biological Tissues in Optical Coherence Tomography

      Speckle Statistics of Biological Tissues in Optical Coherence Tomography

      The speckle statistics of optical coherence tomography images of biological tissue have been studied using several historical probability density functions. A recent hypothesis implies that underlying power-law distributions in the medium structure, such as the fractal branching vasculature, will contribute to power-law probability distributions of speckle statistics. Specifically, these are the Burr type XII distribution for speckle amplitude, the Lomax distribution for intensity, and the generalized logistic distribution for log amplitude. In this study, these three distributions are fitted to histogram data from nine optical coherence tomography scans of various biological tissues and samples. The distributions are also compared with ...

      Read Full Article
    3. Manifestation of aberrations in full-field optical coherence tomography

      Manifestation of aberrations in full-field optical coherence tomography

      We report on a theoretical model for image formation in full-field optical coherence tomography (FFOCT). Because the spatial incoherence of the illumination acts as a virtual confocal pinhole in FFOCT, its imaging performance is equivalent to a scanning time-gated coherent confocal microscope. In agreement with optical experiments enabling a precise control of aberrations, FFOCT is shown to have nearly twice the resolution of standard imaging at moderate aberration level. Beyond a rigorous study on the sensitivity of FFOCT with respect to aberrations, this theoretical model paves the way towards an optimized design of adaptive optics schemes for high-resolution and deep ...

      Read Full Article
    4. Analyzing Epistemic and Aleatoric Uncertainty for Drusen Segmentation in Optical Coherence Tomography Images

      Analyzing Epistemic and Aleatoric Uncertainty for Drusen Segmentation in Optical Coherence Tomography Images

      Age-related macular degeneration (AMD) is one of the leading causes of permanent vision loss in people aged over 60 years. Accurate segmentation of biomarkers such as drusen that points to the early stages of AMD is crucial in preventing further vision impairment. However, segmenting drusen is extremely challenging due to their varied sizes and appearances, low contrast and noise resemblance. Most existing literature, therefore, have focused on size estimation of drusen using classification, leaving the challenge of accurate segmentation less tackled. Additionally, obtaining the pixel-wise annotations is extremely costly and such labels can often be noisy, suffering from inter-observer and ...

      Read Full Article
    5. Inverse spectroscopic optical coherence tomography (ISOCT) for characterization of particle size and concentration

      Inverse spectroscopic optical coherence tomography (ISOCT) for characterization of particle size and concentration

      Inverse spectroscopic optical coherence tomography (IS-OCT) methods apply inverse problem formulations to acquired spectra to estimate depth-resolved sample properties. In the current study, we modelled the time-frequency-distributions using Lambert-Beer law and implemented IS-OCT using backscattering spectra calculated from Mie theory, then demonstrated the algorithm on polystyrene microspheres under idealized conditions. The results are significant because the method is compatible with high concentrations and broad diameter distributions of scattering particles such as organelles in biological cells.

      Read Full Article
    6. In Vivo Quantitative Analysis of Anterior Chamber White Blood Cell Mixture Composition Using Spectroscopic Optical Coherence Tomography

      In Vivo Quantitative Analysis of Anterior Chamber White Blood Cell Mixture Composition Using Spectroscopic Optical Coherence Tomography

      Anterior uveitis is the most common form of intraocular inflammation, and one of its main signs is the presence of white blood cells (WBCs) in the anterior chamber (AC). Clinically, the true composition of cells can currently only be obtained using AC paracentesis, an invasive procedure to obtain AC fluid requiring needle insertion into the AC. We previously developed a spectroscopic optical coherence tomography (SOCT) analysis method to differentiate between populations of RBCs and subtypes of WBCs, including granulocytes, lymphocytes and monocytes, both in vitro and in ACs of excised porcine eyes. We have shown that different types of WBCs ...

      Read Full Article
    7. Maximum A Posteriori Signal Recovery for Optical Coherence Tomography Angiography Image Generation and Denoising

      Maximum A Posteriori Signal Recovery for Optical Coherence Tomography Angiography Image Generation and Denoising

      Optical coherence tomography angiography (OCTA) is a novel and clinically promising imaging modality to image retinal and sub-retinal vasculature. Based on repeated optical coherence tomography (OCT) scans, intensity changes are observed over time and used to compute OCTA image data. OCTA data are prone to noise and artifacts caused by variations in flow speed and patientmovement. We propose a novel iterativemaximuma posteriori signal recovery algorithm in order to generate OCTA volumes with reduced noise and increased image quality. This algorithm is based on previous work on probabilistic OCTA signal models and maximum likelihood estimates. Reconstruction results using total variation minimization ...

      Read Full Article
    8. Low Tensor Train- and Low Multilinear Rank Approximationsfor De-speckling and Compression of 3D Optical Coherence Tomography Images

      Low Tensor Train- and Low Multilinear Rank Approximationsfor De-speckling and Compression of 3D Optical Coherence Tomography Images

      This paper proposes low tensor-train (TT) rank and low multilinear (ML) rank approximations for de-speckling and compression of 3D optical coherence tomography (OCT) images for a given compression ratio (CR). To this end, we derive the alternating direction method of multipliers based algorithms for the related problems constrained with the low TT- and low ML rank. Rank constraints are implemented through the Schatten-p (Sp) norm, p e {0, 1/2, 2/3, 1}, of unfolded matrices. We provide the proofs of global convergence towards a stationary point for both algorithms. Rank adjusted 3D OCT image tensors are finally approximated through ...

      Read Full Article
    9. Self-supervised Denoising via Diffeomorphic Template Estimation: Application to Optical Coherence Tomography

      Self-supervised Denoising via Diffeomorphic Template Estimation: Application to Optical Coherence Tomography

      Optical Coherence Tomography (OCT) is pervasive in both the research and clinical practice of Ophthalmology. However, OCT images are strongly corrupted by noise, limiting their interpretation. Current OCT denoisers leverage assumptions on noise distributions or generate targets for training deep supervised denoisers via averaging of repeat acquisitions. However, recent self-supervised advances allow the training of deep denoising networks using only repeat acquisitions without clean targets as ground truth, reducing the burden of supervised learning. Despite the clear advantages of self-supervised methods, their use is precluded as OCT shows strong structural deformations even between sequential scans of the same subject due ...

      Read Full Article
    10. High space-bandwidth in quantitative phase imaging using partially spatially coherent optical coherence microscopy and deep neural network

      High space-bandwidth in quantitative phase imaging using partially spatially coherent optical coherence microscopy and deep neural network

      Quantitative phase microscopy (QPM) is a label-free technique that enables to monitor morphological changes at subcellular level. The performance of the QPM system in terms of spatial sensitivity and resolution depends on the coherence properties of the light source and the numerical aperture (NA) of objective lenses. Here, we propose high space-bandwidth QPM using partially spatially coherent optical coherence microscopy (PSC-OCM) assisted with deep neural network. The PSC source synthesized to improve the spatial sensitivity of the reconstructed phase map from the interferometric images. Further, compatible generative adversarial network (GAN) is used and trained with paired low-resolution (LR) and high-resolution ...

      Read Full Article
    11. Dueling Deep Q-Network for Unsupervised Inter-frame Eye Movement Correction in Optical Coherence Tomography Volumes

      Dueling Deep Q-Network for Unsupervised Inter-frame Eye Movement Correction in Optical Coherence Tomography Volumes

      In optical coherence tomography (OCT) volumes of retina, the sequential acquisition of the individual slices makes this modality prone to motion artifacts, misalignments between adjacent slices being the most noticeable. Any distortion in OCT volumes can bias structural analysis and influence the outcome of longitudinal studies. On the other hand, presence of speckle noise that is characteristic of this imaging modality, leads to inaccuracies when traditional registration techniques are employed. Also, the lack of a well-defined ground truth makes supervised deep-learning techniques ill-posed to tackle the problem. In this paper, we tackle these issues by using deep reinforcement learning to ...

      Read Full Article
    12. Noise-Powered Disentangled Representation for Unsupervised Speckle Reduction of Optical Coherence Tomography Images

      Noise-Powered Disentangled Representation for Unsupervised Speckle Reduction of Optical Coherence Tomography Images

      Due to its noninvasive character, optical coherence tomography (OCT) has become a popular diagnostic method in clinical settings. However, the low coherence interferometric imaging procedure is inevitably contaminated by heavy speckle noise, which impairs both visual quality and diagnosis of various ocular diseases. Although deep learning has been applied for image denoising and achieved promising results, the lack of well-registered clean and noisy image pairs makes it impractical for supervised learning-based approaches to achieve satisfactory OCT image denoising results. In this paper, we propose an unsupervised OCT image speckle reduction algorithm that does not rely on well-registered image pairs. Specifically ...

      Read Full Article
    13. Frequency-domain optical coherence tomography with undetected mid-infrared photons

      Frequency-domain optical coherence tomography with undetected mid-infrared photons

      Mid-infrared light scatters much less than shorter wavelengths, allowing greatly enhanced penetration depths for optical imaging techniques such as optical coherence tomography (OCT). However, both detection and broadband sources in the mid-IR are technologically challenging. Interfering entangled photons in a nonlinear interferometer enables sensing with undetected photons making mid-IR sources and detectors obsolete. Here we implement mid-infrared frequency-domain OCT based on ultra-broadband entangled photon pairs. We demonstrate 10 µm axial and 20 µm lateral resolution 2D and 3D imaging of strongly scattering ceramic and paint samples. Together with 106 times less noise scaled for the same amount of probe light ...

      Read Full Article
      Mentions: Bettina Heise
    14. AV-Net: Deep learning for fully automated artery-vein classification in optical coherence tomography angiography

      AV-Net: Deep learning for fully automated artery-vein classification in optical coherence tomography angiography

      This study is to demonstrate deep learning for automated artery-vein (AV) classification in optical coherence tomography angiography (OCTA). The AV-Net, a fully convolutional network (FCN) based on modified U-shaped CNN architecture, incorporates enface OCT and OCTA to differentiate arteries and veins. For the multi-modal training process, the enface OCT works as a near infrared fundus image to provide vessel intensity profiles, and the OCTA contains blood flow strength and vessel geometry features. A transfer learning process is also integrated to compensate for the limitation of available dataset size of OCTA, which is a relatively new imaging modality. By providing an ...

      Read Full Article
    15. Optical Coherence Tomography with an SU(1,1) interferometer in the high parametric gain regime

      Optical Coherence Tomography with an SU(1,1) interferometer in the high parametric gain regime

      Gerard J. Machado,1, a) Gaetano Frascella,2, 3 Juan P. Torres,1, 4 and Maria V. Chekhova

      We demonstrate optical coherence tomography based on an SU(1,1) nonlinear interferometer with high-gain parametric down-conversion. For imaging and sensing applications, this scheme promises to outperform previous experiments working at low parametric gain, since higher photon fluxes provide better sensitivity and lower integration times for obtaining high-quality images. Moreover, there is no need to use single-photon detectors and standard spectrometers can be used instead.

      Read Full Article
    16. Automated segmentation of retinal fluid volumes from structural and angiographic optical coherence tomography using deep learning

      Automated segmentation of retinal fluid volumes from structural and angiographic optical coherence tomography using deep learning

      Purpose: We proposed a deep convolutional neural network (CNN), named Retinal Fluid Segmentation Network (ReF-Net) to segment volumetric retinal fluid on optical coherence tomography (OCT) volume. Methods: 3 × 3-mm OCT scans were acquired on one eye by a 70-kHz OCT commercial AngioVue system (RTVue-XR; Optovue, Inc.) from 51 participants in a clinical diabetic retinopathy (DR) study (45 with retinal edema and 6 healthy controls). A CNN with U-Net-like architecture was constructed to detect and segment the retinal fluid. Cross-sectional OCT and angiography (OCTA) scans were used for training and testing ReF-Net. The effect of including OCTA data for retinal fluid ...

      Read Full Article
    17. Quantum Optical Coherence Tomography using two photon joint spectrum detection (JS-Q-OCT)

      Quantum Optical Coherence Tomography using two photon joint spectrum detection (JS-Q-OCT)

      Quantum Optical Coherence Tomography (Q-OCT) is the non-classical counterpart of Optical Coherence Tomography (OCT) - a high-resolution 3D imaging technique based on white-light interferometry. Because Q-OCT uses a source of frequency-entangled photon pairs, not only is the axial resolution not affected by dispersion mismatch in the interferometer, but is also inherently improved by a factor of square root of two. Unfortunately, practical applications of QOCT are hindered by image-scrambling artefacts and slow acquisition times. Here, we present a theoretical analysis of a novel approach that is free of these problems: Q-OCT with joint spectrum detection (JS-Q-OCT). Based on a photon pair ...

      Read Full Article
    18. Nanosensitive optical coherence tomography to assess wound healing within the cornea

      Nanosensitive optical coherence tomography to assess wound healing within the cornea

      Optical Coherence Tomography (OCT) is a non-invasive depth resolved optical imaging modality, that enables high resolution, cross-sectional imaging in biological tissues and materials at clinically relevant depths. Though OCT offers high resolution imaging, the best ultra-high-resolution OCT systems are limited to imaging structural changes with a resolution of one micron on a single B-scan within very limited depth. Nanosensitive OCT (nsOCT) is a recently developed technique that is capable of providing enhanced sensitivity of OCT to structural changes. Improving the sensitivity of OCT to detect structural changes at the nanoscale level, to a depth typical for conventional OCT, could potentially ...

      Read Full Article
    19. Tethered capsule en face optical coherence tomography for imaging Barrett’s esophagus in unsedated patients

      Tethered capsule en face optical coherence tomography for imaging Barrett’s esophagus in unsedated patients

      Objective Detection of Barrett’s esophagus (BE) at points of care outside the endoscopy suite may improve screening access and reduce esophageal adenocarcinoma mortality. Tethered capsule optical coherence tomography (OCT) can volumetrically image esophageal mucosa and detect BE in unsedated patients. We investigated ultrahigh-speed tethered capsule, swept-source OCT (SS-OCT) in unsedated patients, improved device design, developed procedural techniques, measured how capsule contact and longitudinal pullback non-uniformity affect coverage, and assessed patient toleration. Design OCT was performed in 16 patients prior to endoscopic surveillance/treatment. Unsedated patients swallowed the capsule with small sips of water and the esophagus imaged by retracting ...

      Read Full Article
    20. IMPROVING ROBUSTNESS USING JOINT ATTENTION NETWORK FOR DETECTING RETINAL DEGENERATION FROM OPTICAL COHERENCE TOMOGRAPHY IMAGES

      IMPROVING ROBUSTNESS USING JOINT ATTENTION NETWORK FOR DETECTING RETINAL DEGENERATION FROM OPTICAL COHERENCE TOMOGRAPHY IMAGES

      Noisy data and the similarity in the ocular appearances caused by different ophthalmic pathologies pose significant challenges for an automated expert system to accurately detect retinal diseases. In addition, the lack of knowledge transferability and the need for unreasonably large datasets limit clinical application of current machine learning systems. To increase robustness, a better understanding of how the retinal subspace deformations lead to various levels of disease severity needs to be utilized for prioritizing disease-specific model details. In this paper we propose the use of disease-specific feature representation as a novel architecture comprised of two joint networks – one for supervised ...

      Read Full Article
    21. AGE Challenge: Angle Closure Glaucoma Evaluation in Anterior Segment Optical Coherence Tomography

      AGE Challenge: Angle Closure Glaucoma Evaluation in Anterior Segment Optical Coherence Tomography

      Angle closure glaucoma (ACG) is a more aggressive disease than open-angle glaucoma, where the abnormal anatomical structures of the anterior chamber angle (ACA) may cause an elevated intraocular pressure and gradually leads to glaucomatous optic neuropathy and eventually to visual impairment and blindness. Anterior Segment Optical Coherence Tomography (AS-OCT) imaging provides a fast and contactless way to discriminate angle closure from open angle. Although many medical image analysis algorithms have been developed for glaucoma diagnosis, only a few studies have focused on AS-OCT imaging. In particular, there is no public AS-OCT dataset available for evaluating the existing methods in a ...

      Read Full Article
    22. Optical coherence tomography imaging of evoked neural activity in sciatic nerve of rat

      Optical coherence tomography imaging of evoked neural activity in sciatic nerve of rat

      Significance: Imaging neural activity in myelinated tissue using optical coherence tomography (OCT) creates exciting possibilities for functional imaging in the peripheral and central nervous systems. Aim: To investigate changes in OCT images in response to evoked neural activity in sciatic nerve of rat in vitro. Approach: M-scans were obtained on peripheral nerves of rat using a swept source polarisation sensitive OCT system, while a nerve cuff acquired electrical neural recordings. From a total of 10 subjects: 3 had no stimulation (controls), 3 had paw stimulation, and 4 had nerve stimulation. Changes in the OCT signal intensity, phase retardation, phase, and ...

      Read Full Article
    23. Pseudo-real-time retinal layer segmentation for high-resolution adaptive optics optical coherence tomography

      Pseudo-real-time retinal layer segmentation for high-resolution adaptive optics optical coherence tomography

      We present a pseudo-real-time retinal layer segmentation for high-resolution Sensorless Adaptive Optics-Optical Coherence Tomography (SAO-OCT). Our pseudo-real-time segmentation method is based on Dijkstra’s algorithm that uses the intensity of pixels and the vertical gradient of the image to find the minimum cost in a geometric graph formulation within a limited search region. It segments six retinal layer boundaries in an iterative process according to their order of prominence. The segmentation time is strongly correlated to the number of retinal layers to be segmented. Our program permits en face images to be extracted during data acquisition to guide the depth ...

      Read Full Article
    24. Curved-field optical coherence tomography: large-field imaging of human corneal cells and nerves

      Curved-field optical coherence tomography: large-field imaging of human corneal cells and nerves

      High-resolution optical imaging methods, such as confocal microscopy and full-field optical coherence tomography, capture flat optical sections of the sample. If the sample is curved, the optical field sections through several sample layers and the view of each layer is reduced. Here we present curved-field optical coherence tomography, capable of capturing optical sections of arbitrary curvature. We test the device on a challenging task of imaging the human cornea in vivo and achieve 10× larger viewing area comparing to the clinical state-of-theart. This enables more precise cell and nerve counts, opening a path to improved diagnosis of corneal and general ...

      Read Full Article
    1-24 of 164 1 2 3 4 5 6 7 »
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks