Related Entities
Optovue Receives FDA Clearance for Cornea/Anterior Module for RTVue
46 articles also mentioned Optovue
Optovue Fastest Growing Ophthalmic Device Company in Eye Care
24 articles also mentioned Carl Zeiss Meditec
Spectral-domain optical coherence tomography represents step forward, physician says
13 articles also mentioned Zeiss Stratus OCT
The Evolution of Spectral Domain OCT
12 articles also mentioned Zeiss Cirrus HD-OCT
Take a new look at existing devices, surgeon suggests
11 articles also mentioned Heidelberg Engineering
A Pilot Study of Fourier-Domain Optical Coherence Tomography of Retinal Dystrophy Patients
9 articles also mentioned David Huang
-
Mentioned In 47 Articles
-
Macular and Peripapillary Retinal Nerve Fiber Layer Measurements by Spectral Domain Optical Coherence Tomography in Normal-Tension Glaucoma
Explore Article iovs.org (Feb 26 2010) Ophthalmology
...tinal nerve fiber layer (pRNFL) thickness measured by spectral-domain optical coherence tomography (RTVue-100; Optovue Inc, Fremont, CA) in patients with normal-tension glaucoma (NTG). Methods. Sixty-five ... (Read Full Article)
Comment on Article Mentions: Optovue University of Ulsan Optovue RTVue-100
-
Spectral-domain Optical Coherence Tomography Measurement of Macular Volume for Diagnosing Glaucoma
Explore Article LWW Online (Feb 17 2010) Ophthalmology
... Fifty eyes with open-angle glaucoma and 35 normal partipants were included for this study. SD-OCT (RTVue-100), and time-domain (TD)-OCT were used to measure total retinal, GCC (SD-OCT only), and circumpapilla... (Read Full Article)
Comment on Article Mentions: Optovue RTVue-100 Nagahisa Yoshimura Optovue
-
Anterior-segment imaging for assessment of glaucoma
Explore Article Expert Reviews (Feb 1 2010) Ophthalmology
This article summarizes the physics, technology and clinical application of ultrasound biomicroscopy (UBM) and optical coherence tomography (OCT) for assessment of the anterior segment in glaucoma. UBM systems use frequencies ranging from approximately 35 to 80 MHz, as compared with typical 10-MHz systems used for general-purpose ophthalmic imaging. OCT systems use low-coherence, near-infrared light to provide detailed images of anterior segment structures at resolutions exceeding that of UBM. Both technologies ...
(Read Full Article)
Comment on Article Mentions: Roxana Ursea OTI Ophthalmic Technologies Inc. Optovue
-
Artifacts In Automatic Retinal Segmentation Using Different Optical Coherence Tomography Instruments
Explore Article LWW Online (Jan 23 2010) Ophthalmology
...ther OCT systems, and this was statistically significant for all devices (P <= 0.005) except the Optovue RTvue-100 (P = 0.165). Conclusion: Spectral-domain OCT instruments reduce, but do not eliminate, errors in... (Read Full Article)
Comment on Article Mentions: Optovue Harvard University Carl Zeiss Meditec
-
Reproducibility of Retinal Nerve Fiber Layer and Macular Thickness Measurement with the RTVue-100 Optical Coherence Tomography
Explore Article OphSource (Jan 14 2010) Ophthalmology
...inal nerve fiber layer thickness (RNFLT) and ganglion cell complex (GCC) measurements made with the RTVue-100 Fourier-domain optical coherence tomography (OCT) device (Optovue, Inc., Fremont, CA) and to determ... (Read Full Article)
Comment on Article Mentions: Optovue Optovue RTVue-100
-
Identifying early recurrence of choroidal neovascularization during treatment with ranibizumab using C-scan
Explore Article eur-j-ophthalmol.com (Jan 4 2010) Ophthalmology
...ered monthly for 3 months and their progress was monitored at 1 week and then at monthly intervals. RTVue spectral domain optical coherence tomography (OCT) was performed in all patients monthly using summ... (Read Full Article)
Comment on Article Mentions: Optovue Optovue RTVue-100
-
COMPARISON OF SPECTRAL/FOURIER DOMAIN OPTICAL COHERENCE TOMOGRAPHY INSTRUMENTS FOR ASSESSMENT OF NORMAL MACULAR THICKNESS
Explore Article LWW Online (Dec 3 2009) Ophthalmology
...rcially available spectral/Fourier domain OCT instruments (Cirrus HD-OCT, Carl Zeiss Meditec, Inc.; RTVue-100, Optovue, Inc., Fremont, CA; 3D OCT-1000, Topcon, Inc., Paramus, NJ). Methods: Forty randomly se......s values ranging 84.8% to 94.9% for Stratus OCT; 92.6% to 97.3% for Cirrus Cube; 76.4% to 93.7% for RTVue MM5; 61.1% to 96.8% for MM6; 93.1% to 97.9% for 3D OCT-1000 radial; and 31.5% to 97.5% for 3D macul... (Read Full Article)
Comment on Article Mentions: University of Pittsburgh Massachusetts Institute of Technology James G. Fujimoto
-
Evaluation of optic nerve head and retinal nerve fiber layer in early and advance glaucoma using frequency-domain optical coherence tomography
Explore Article SpringerLink Home (Nov 25 2009) Ophthalmology
...tool which has contributed to earlier and more accurate diagnosis of glaucoma over the past decade. RTVue OCT was the first frequency-domain OCT (FD-OCT) device to offer comprehensive glaucoma analysis inc... (Read Full Article)
Comment on Article Mentions: Optovue RTVue-100 Capital Medical University Optovue
-
Optovues Symposium at Ascrs 2008 David Huang, MD, PhD. pt3 (Video)
Explore Article YouTube (Nov 19 2009)
...ptovue's symposium at ASCRS 2008, Dr. David Huang talks about anterior segment imaging with the RTVue Fourier-Domain Optical Coherence Tomography (OCT). Optovues Symposium at ASCRS 2008 David Huang, M... (Read Full Article)
Comment on Article Mentions: Optovue David Huang Optovue RTVue-100
-
Optovues Symposium at Ascrs 2008 David Huang, MD, PhD. Pt2 (Video)
Explore Article YouTube (Nov 19 2009) Ophthalmology
...ptovue's symposium at ASCRS 2008, Dr. David Huang talks about anterior segment imaging with the RTVue Fourier-Domain Optical Coherence Tomography (OCT). Optovues Symposium at ASCRS 2008 David Huang, M... (Read Full Article)
Comment on Article Mentions: Optovue David Huang Optovue RTVue-100
-
Optovues Symposium at ASCRS 2008 David Huang, MD, PhD. pt1 (Video)
Explore Article YouTube (Nov 19 2009) Ophthalmology
...ptovue's symposium at ASCRS 2008, Dr. David Huang talks about anterior segment imaging with the RTVue Fourier-Domain Optical Coherence Tomography (OCT). Optovues Symposium at ASCRS 2008 David Huang, MD... (Read Full Article)
Comment on Article Mentions: Optovue David Huang Optovue RTVue-100
-
Optovues Symposium at Ascrs 2008 Advanced Imaging with Fourier-Domain OCT pt1 (Video)
Explore Article YouTube (Nov 19 2009) Ophthalmology
Located in Fremont California, Optovue Corporation is an ophthalmic device company. Our goal is to lead the commercialization of new imaging modalities that improve diagnosis and therapy of ocular diseases. In this video, a part of Optovue's symposium at ASCRS 2008, Dr. Vikas Chopra of Doheny Eye Institue talks about advanced imaging with Fourier-Domain OCT in glaucoma. (Read Full Article)
Comment on Article Mentions: Optovue Optovue RTVue-100 Vikas Chopra
-
Retinal Nerve Fiber Layer Thickness Measurement by Fourier-domain Optical Coherence Tomography: A Comparison Between Cirrus-HD OCT and RTVue in Healthy Eyes
Explore Article LWW Online (Oct 23 2009) Ophthalmology
... measurements by 2 Fourier-domain optical coherence tomography (OCT) instruments: Cirrus-HD OCT and RTVue. Materials and Methods: Twenty-three eyes of 23 healthy participants underwent RNFL thickness meas... (Read Full Article)
Comment on Article Mentions: Optovue RTVue-100 Optovue Carl Zeiss Meditec
-
Diagnostic Comparison between Macular and Peripapillary Retinal Nerve Fiber Layer Measurements by Spectral Domain Optical Coherence Tomography in Normal-Tension Glaucoma
Explore Article iovs.org (Oct 16 2009) Ophthalmology
...tinal nerve fiber layer (pRNFL) thickness measured by spectral-domain optical coherence tomography (RTVue-100) in normal-tension glaucoma (NTG) patients. Methods: Sixty-five healthy and 102 NTG subjects we... (Read Full Article)
Comment on Article Mentions: University of Ulsan Optovue RTVue-100 Sung Yong Kang
-
Reproducibility of Tear Meniscus Measurement by Fourier-Domain Optical Coherence Tomography: A Pilot Study
Explore Article Ophthalmic Surgery, Lasers and Imaging (Sep 24 2009) Ophthalmology
...aged by vertical scans centered on the inferior cornea and the lower eyelid using an FD-OCT system (RTVue; Optovue, Inc., Fremont, CA) with a corneal adaptor. The system performs 26,000 axial scans per sec... (Read Full Article)
Comment on Article Mentions: David Huang Keck School of Medicine Center for Ophthalmic Optics and Lasers







Recent Comments
Eric Swanson » Jim Fujimoto video: Biophotonics and optical coherence tomography
Great video Jim!
dariemihaela » Gary S. Mintz
Dear Prof. Dr. Gary S. Mintz, You are an extraordinary expert in imaging, an intelligence ...
See all recent comments