1. Mentioned In 10 Articles

  2. Intravascular optical coherence tomography on a beating heart model

    Explore Article SPIE Digital Library (Aug 9 2010)

    Intravascular optical coherence tomography on a beating heart model ...023 (2010); doi:10.1117/1.3475960 Published 9 August 2010 ABSTRACT REFERENCES (21) Guy Lamouche and Marc Dufour Conseil National de Recherches Canada, Institut des Matériaux Industriels, 75 de Mortagne, Boucherv... (Read Full Article)

    Comment on Article Mentions:   Guy Lamouche   Marc L. Dufour   Sebastien Vergnole

  3. Durable coronary artery phantoms for optical coherence tomography

    Explore Article SPIE Digital Library (Feb 23 2009)

    ...e Lanthier National Research Council Canada (Canada) and Ecole Polytechnique de Montréal (Canada) Marc L. Dufour National Research Council Canada (Canada) Guy Lamouche National Research Council Canada (Canada) ... (Read Full Article)

    Comment on Article Mentions:   Ecole Polytechnique de Montréal   Guy Lamouche   Marc L. Dufour

  4. Ex vivo imaging of early dental caries within the interproximal space

    Explore Article SPIE Digital Library (Feb 18 2009)

    Lin-P'ing Choo-Smith, Mark D. Hewko, Marc L. Dufour et al. Optical coherence tomography (OCT) is emerging as a technology that can potentially be used... (Read Full Article)

    Comment on Article Mentions:   Guy Lamouche   Marc L. Dufour   Mark D. Hewko

  5. Method and apparatus for scanning optical delay line

    Explore Article uspto.gov (Sep 23 2008)

    The present invention relates in general to optical interferometric systems, and in particular to scanning optical delay lines of an interferometric system.Interferometric systems are deployed in a wide and growing number of applications. Typically, interferometric systems involve two arms, a beam splitter and a beam combiner. A beam of light incident the beam splitter is divided in two: one partof the beam is directed down each of the arms. The ... (Read Full Article)

    Comment on Article Mentions:   Guy Lamouche   Marc L. Dufour   National Research Council Canada

  6. Deformable and durable phantoms with controlled density of scatterers

    Explore Article Institute of Physics (Jun 16 2008)

    Author(s): Charles-Etienne Bisaillon, Guy Lamouche, Romain Maciejko, Marc Dufour and Jean-Pierre Monchalin. Affiliation(s): Industrial Materials Institute, National Research Counci... (Read Full Article)

    Comment on Article Mentions:   Ecole Polytechnique de Montréal   Romain Maciejko   National Research Council Canada

  7. Artifact removal in Fourier-domain optical coherence tomography with a piezoelectric fiber stretcher

    Explore Article opticsinfobase.org (Mar 28 2008)

    Sébastien Vergnole, Guy Lamouche, Marc L. Dufour. We describe an artifact removal setup swept-source optical coherence tomography (OCT) system that......ised Manuscript: February 15, 2008 Published: March 31, 2008 Citation S. Vergnole, G. Lamouche, and M. L. Dufour, "Artifact removal in Fourier-domain optical coherence tomography with a piezoelectric fiber stretc... (Read Full Article)

    Comment on Article Mentions:   Guy Lamouche   Sebastien Vergnole   Marc L. Dufour

  8. Particle size measurement in glass powder beds using optical coherence tomography

    Explore Article SPIE Digital Library (Mar 21 2008)

    Jocelyn Veilleux, Christian Moreau, Daniel Levesque et al. Optical coherence tomography was used to collect cross-sectional images of glass powder beds consisting of microspheres with diameters ranging from 8 to 175 [mu]m. Images were formed by a collection of individual interferogram envelopes that give the backscattered light amplitude as a function of t ... [Opt. Eng. 47, 033601 (2008)] published Fri Mar 21, 2008. (Read Full Article)

    Comment on Article Mentions:   Marc L. Dufour   National Research Council Canada

  9. Common path SS-OCT interferometer with artifact removal

    Explore Article SPIE Digital Library (Feb 18 2008)

    S. Vergnole, G. Lamouche, M. Dufour et al. We present here the implementation of a fiber-based common-path interferometer for Swept So... (Read Full Article)

    Comment on Article Mentions:   Guy Lamouche   Marc L. Dufour   Sebastien Vergnole

  10. Artifact removal in Fourier-domain OCT with a rotating probe

    Explore Article SPIE Digital Library (Feb 5 2008)

    Sebastien Vergnole, Guy Lamouche, Marc L. Dufour et al. This paper reports the study of a Swept Source Optical Coherence Tomography (SS-OCT) setup ... (Read Full Article)

    Comment on Article Mentions:   Guy Lamouche   Marc L. Dufour   Sebastien Vergnole

  11. Method and apparatus for three-dimensional compositional mapping of heterogeneous materials

    Explore Article uspto.gov (Mar 29 2005)

    Laser ablation combined with spectrometric analysis is a good tool for determining the composition of heterogeneous materials. By measuring the depth of an ablation crater at a target of a heterogeneous material, it is possible to generate a compositional profile as a function of the depth. It is also possible to generate a 3 dimensional profile by depth profiling of a plurality of craters. The depth measurement is conducted in ... (Read Full Article)

    Comment on Article Mentions:   National Research Council Canada   Marc L. Dufour

1-10 of 10