    1. Early vascular responses to everolimus-eluting cobalt–chromium stent in the culprit lesions of st-elevation myocardial infarction: results from a multicenter prospective optical coherence tomography study (MECHANISM-AMI 2-week follow-up study)

      Early vascular responses to everolimus-eluting cobalt–chromium stent in the culprit lesions of st-elevation myocardial infarction: results from a multicenter prospective optical coherence tomography study (MECHANISM-AMI 2-week follow-up study)

      The use of cobalt–chromium everolimus-eluting stents (CoCr-EES) for ST-segment elevation myocardial infarction (STEMI) reduces the incidence of stent thrombosis compared with bare metal stents, and a substantial difference is apparent in the initial 2 weeks. However, vascular behavior during this early period remains unclear. This was a prospective study (MECHANISM-AMI-2W) to investigate early vascular responses in STEMI patients immediately after CoCr-EES implantation and at 2-week follow-up using frequency domain-optical coherence tomography (FD-OCT). The study enrolled 52 patients (age 63.7 ± 11.7 years, male 85.0%), of whom 44 patients were available for complete serial FD-OCT analyses. Both % uncovered ...

      Read Full Article
    2. Two-year vascular responses to drug-eluting stents with biodegradable polymer versus durable polymer: An optical coherence tomography sub-study of the NEXT

      Two-year vascular responses to drug-eluting stents with biodegradable polymer versus durable polymer: An optical coherence tomography sub-study of the NEXT

      Background This study aimed to compare very late vascular response after stent implantation between everolimus-eluting stent (EES) with a thin, non-adhesive, durable, biocompatible fluorinated polymer and biolimus-eluting stent (BES) with a biodegradable polymer by optical coherence tomography (OCT). Methods and results In the NOBORI-BES Versus XIENCE V/PROMUS-EES Trial (NEXT), a formal OCT substudy investigated 48 patients (27 EES-treated lesions in 23 patients and 28 BES-treated lesions in 25 patients) with 2-year (18–30 months) follow-up imaging at 18 centers. The percentage of uncovered strut by neointima was significantly lower in EES compared with BES (2.1 ± 4.7% vs ...

      Read Full Article
    3. Is quantitative coronary angiography reliable in assessing the late lumen loss of the everolimus eluting bioresorbable polylactide scaffold in comparison with the cobalt chromium metallic stent?

      Is quantitative coronary angiography reliable in assessing the late lumen loss of the everolimus eluting bioresorbable polylactide scaffold in comparison with the cobalt chromium metallic stent?

      Aims: Immediately after stent/scaffold implantation, quantitative coronary angiography (QCA) with respect to optical coherence tomography (OCT) more severely underestimates the lumen diameter (LD) in Absorb than in XIENCE. This OCT-QCA discrepancy has not been evaluated at long-term follow-up. The present study aimed to assess the accuracy of QCA with reference to OCT in Absorb as compared to XIENCE.

       

       

      Read Full Article
    4. Fate of post-procedural malapposition of everolimus-eluting polymeric bioresorbable scaffold and everolimus-eluting cobalt chromium metallic stent in human coronary arteries: sequential assessment with optical coherence tomography in ABSORB Japan trial

      Fate of post-procedural malapposition of everolimus-eluting polymeric bioresorbable scaffold and everolimus-eluting cobalt chromium metallic stent in human coronary arteries: sequential assessment with optical coherence tomography in ABSORB Japan trial

      Aims The natural course of post-procedural incomplete strut apposition (ISA) after the implantation of bioresorbable scaffolds (BVS) remains unknown. The purpose of the present study was to evaluate the fate of post-procedural ISA after everolimus-eluting Absorb BVS in comparison with the second-generation everolimus-eluting cobalt chromium stent (CoCr-EES). Methods and results Fate of post-procedural ISA was evaluated by serial optical coherence tomography (OCT) in the ABSORB Japan randomized trial [OCT-1 subgroup: 110 paired lesions of post-procedure and 2-year follow-up (BVS 73 lesions vs. CoCr-EES 37 lesions)] with respect to ISA distance. Post-procedure ISA struts were categorized into either ‘resolved’ or ‘persistent ...

      Read Full Article
    5. Two-year clinical, angiographic, and serial optical coherence tomographic follow-up after implantation of an everolimus-eluting bioresorbable scaffold and an everolimus-eluting metallic stent: insights from the randomised ABSORB Japan trial

      Two-year clinical, angiographic, and serial optical coherence tomographic follow-up after implantation of an everolimus-eluting bioresorbable scaffold and an everolimus-eluting metallic stent: insights from the randomised ABSORB Japan trial

      Aims: We sought to investigate two-year clinical and serial optical coherence tomography (OCT) outcomes after implantation of a fully bioresorbable vascular scaffold (BVS) or a cobalt-chromium everolimus-eluting stent (CoCr-EES). Methods and results: In the ABSORB Japan trial, 400 patients were randomised in a 2:1 ratio to BVS (N=266) or CoCr-EES (N=134). A pre-specified OCT subgroup (N=125, OCT-1 group) underwent angiography and OCT post procedure and at two years. Overall, the two-year TLF rates were 7.3% and 3.8% in the BVS and CoCr-EES arms (p=0.18), respectively. Very late scaffold thrombosis (VLST) beyond one ...

      Read Full Article
    6. Comparative analysis method of permanent metallic stents (XIENCE) and bioresorbable poly-L-lactic (PLLA) scaffolds (Absorb) on optical coherence tomography at baseline and follow-up

      Comparative analysis method of permanent metallic stents (XIENCE) and bioresorbable poly-L-lactic (PLLA) scaffolds (Absorb) on optical coherence tomography at baseline and follow-up

      Aims: Fully bioresorbable Absorb poly-L-lactic-acid (PLLA) scaffolds (Abbott Vascular, Santa Clara, CA, USA) are a novel approach for the treatment of coronary narrowing. Due to the translucency of the material (PLLA), the optical coherence tomography (OCT) measurement methods used in the ABSORB trials were unique but not applicable for permanent metallic stents. When the Absorb scaffold and metallic stents are compared in the context of randomised trials, it is challenging to compare the two devices using the conventional methods. The primary purpose of this report is to explain the biases in conventional methodologies applied for metallic stents and for PLLA ...

      Read Full Article
    7. Comparison of neointimal coverage between everolimus-eluting stents and sirolimus-eluting stents: an optical coherence tomography substudy of the RESET (Randomized Evaluation of Sirolimus-eluting versus Everolimus-eluting stent Trial)

      Comparison of neointimal coverage between everolimus-eluting stents and sirolimus-eluting stents: an optical coherence tomography substudy of the RESET (Randomized Evaluation of Sirolimus-eluting versus Everolimus-eluting stent Trial)

      Aims: The aim of the present study was to compare vascular healing response between the first-generation sirolimus-eluting stent (SES) and the second-generation everolimus-eluting stent (EES) by using optical coherence tomography (OCT). Methods and results: The RESET was a prospective, multicentre, randomised, open-label trial comparing EES and SES. Of the 3,197 patients enrolled in the RESET, nine-month follow-up OCT after stent implantation was performed in 100 patients (48 EES-treated lesions in 44 patients and 62 SES-treated lesions in 56 patients), thus constituting the OCT substudy population. The percentage of uncovered struts per lesion (8±15% vs. 14±19%, p=0 ...

      Read Full Article
    8. Early Phase Arterial Reaction Following Drug-Eluting and Bare-Metal Stent Implantation in Patients With ST-Segment Elevation Myocardial Infarction Optical Coherence Tomography Assessment at 2 Weeks

      Early Phase Arterial Reaction Following Drug-Eluting and Bare-Metal Stent Implantation in Patients With ST-Segment Elevation Myocardial Infarction Optical Coherence Tomography Assessment at 2 Weeks

      The early phase arterial reaction after implantation of second-generation drug-eluting stents (2nd DES) and baremetal stents (BMS) in patients with ST-segment elevation myocardial infarction (STEMI) remains unclear. The MECHANISM pilot study is a multi-center prospective registry that enrolled 24 STEMI patients (from 11 centers) who had undergone implantation of everolimus-eluting ( n = 6), biolimus A9-eluting ( n = 6) or zotarolimus-eluting stents ( n = 6), or BMS ( n = 6). Scheduled optical coherence tomography (OCT) was performed 2 weeks after implantation, and images were independently analyzed at a core laboratory in a blinded fashion. Intra-stent thrombus was quantitatively analyzed in terms of the maximal area ...

      Read Full Article
    9. Outcomes of everolimus-eluting stent incomplete stent apposition: a serial optical coherence tomography analysis

      Outcomes of everolimus-eluting stent incomplete stent apposition: a serial optical coherence tomography analysis

      Aim The aim of the present study was to evaluate the natural course of acute incomplete stent apposition (ISA) after second-generation everolimus-eluting stent (EES) when compared with first-generation sirolimus-eluting stent (SES) by using optical coherence tomography (OCT). Methods and results From the OCT substudy of the RESET trial, we identified 77 patients (EES = 38 and SES = 39) who successfully underwent serial OCT examination at post-stenting and 8–12-month follow-up. The presence of ISA was assessed in the OCT images, and ISA distance was measured from the centre of the strut blooming to the adjacent lumen border. Incomplete stent apposition was ...

      Read Full Article
    10. Vascular Response to Drug-Eluting Stent With Biodegradable vs. Durable Polymer

      Vascular Response to Drug-Eluting Stent With Biodegradable vs. Durable Polymer

      Background: The aim of the present study was to compare vascular healing response between everolimus-eluting stent (EES) and biolimus-eluting stent (BES) using optical coherence tomography (OCT). Methods and Results: In the NOBORI Biolimus-Eluting Versus XIENCE V/PROMUS Everolimus-Eluting Stent Trial (NEXT), a formal OCT substudy investigated 91 patients (55 EES-treated lesions in 48 patients and 51 BES-treated lesions in 43 patients) with 8–12 months follow-up imaging at 18 centers. A total of 980 frames with 8,996 struts in EES and 907 frames with 8,745 struts in BES were analyzed. Mean neointima thickness in EES and BES was ...

      Read Full Article
    1-10 of 10
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (5 articles) Toshiro Shinke
    2. (5 articles) Takashi Akasaka
    3. (4 articles) Erasmus University
    4. (4 articles) Kazushige Kadota
    5. (4 articles) Patrick W. Serruys
    6. (4 articles) Yasushi Ino
    7. (4 articles) Yoshinobu Onuma
    8. (4 articles) Takashi Kubo
    9. (3 articles) Kyoto University Graduate School of Medicine
    10. (3 articles) Kobe University Graduate School of Medicine
    11. (1 articles) Washington University in St. Louis
    12. (1 articles) UCLA
    13. (1 articles) Srinivas R. Sadda
    14. (1 articles) Quing Zhu
  3. Popular Articles

  4. Picture Gallery

    Vascular Response to Drug-Eluting Stent With Biodegradable vs. Durable Polymer Outcomes of everolimus-eluting stent incomplete stent apposition: a serial optical coherence tomography analysis Early Phase Arterial Reaction Following Drug-Eluting and Bare-Metal Stent Implantation in Patients With ST-Segment Elevation Myocardial Infarction Optical Coherence Tomography Assessment at 2 Weeks Comparison of neointimal coverage between everolimus-eluting stents and sirolimus-eluting stents: an optical coherence tomography substudy of the RESET (Randomized Evaluation of Sirolimus-eluting versus Everolimus-eluting stent Trial) Comparative analysis method of permanent metallic stents (XIENCE) and bioresorbable poly-L-lactic (PLLA) scaffolds (Absorb) on optical coherence tomography at baseline and follow-up Two-year clinical, angiographic, and serial optical coherence tomographic follow-up after implantation of an everolimus-eluting bioresorbable scaffold and an everolimus-eluting metallic stent: insights from the randomised ABSORB Japan trial Fate of post-procedural malapposition of everolimus-eluting polymeric bioresorbable scaffold and everolimus-eluting cobalt chromium metallic stent in human coronary arteries: sequential assessment with optical coherence tomography in ABSORB Japan trial Is quantitative coronary angiography reliable in assessing the late lumen loss of the everolimus eluting bioresorbable polylactide scaffold in comparison with the cobalt chromium metallic stent? Two-year vascular responses to drug-eluting stents with biodegradable polymer versus durable polymer: An optical coherence tomography sub-study of the NEXT Early vascular responses to everolimus-eluting cobalt–chromium stent in the culprit lesions of st-elevation myocardial infarction: results from a multicenter prospective optical coherence tomography study (MECHANISM-AMI 2-week follow-up study) Close Assessment and Testing for Chronic Graft Versus Host Disease, CATCH Study GaAs-Based InPBi Quantum Dots for High Efficiency Super-Luminescence Diodes