1. Articles from Jeff Goshe

    1-3 of 3
    1. The DISCOVER Study 3-Year Results

      The DISCOVER Study 3-Year Results

      Purpose To report the 3-year assessment of feasibility and usefulness of microscope-integrated intraoperative OCT (iOCT) during ophthalmic surgery. Design Prospective, consecutive case series. Participants Adult participants undergoing incisional ophthalmic surgery with iOCT imaging who consented to be enrolled in the Determination of Feasibility of Intraoperative Spectral-Domain Microscope Combined/Integrated OCT Visualization during En Face Retinal and Ophthalmic Surgery (DISCOVER) study. Methods The DISCOVER study is a single-site, multisurgeon, institutional review board-approved investigational device prospective study. Participants included patients undergoing anterior or posterior segment surgery who underwent iOCT imaging with 1 of 3 prototype microscope-integrated iOCT systems (i.e., Zeiss Rescan ...

      Read Full Article
    2. Determination of Feasibility and Utility of Microscope-Integrated Optical Coherence Tomography During Ophthalmic Surgery The DISCOVER Study RESCAN Results

      Determination of Feasibility and Utility of Microscope-Integrated Optical Coherence Tomography During Ophthalmic Surgery The DISCOVER Study RESCAN Results

      Importance Optical coherence tomography (OCT) has transformed the clinical management of a myriad of ophthalmic conditions. Applying OCT to ophthalmic surgery may have implications for surgical decision making and patient outcomes. Objective To assess the feasibility and effect on surgical decision making of a microscope-integrated intraoperative OCT (iOCT) system. Design, Setting, and Participants Report highlighting the 1-year results (March 2014–February 2015) of the RESCAN 700 portion of the DISCOVER (Determination of Feasibility of Intraoperative Spectral Domain Microscope Combined/Integrated OCT Visualization During En Face Retinal and Ophthalmic Surgery) study, a single-site, multisurgeon, prospective consecutive case series regarding this investigational ...

      Read Full Article
      Mentions: Cleveland Clinic
    3. The Prospective Intraoperative and Perioperative Ophthalmic ImagiNg with Optical CoherEncE TomogRaphy (PIONEER) Study: 2-year Results

      The Prospective Intraoperative and Perioperative Ophthalmic ImagiNg with Optical CoherEncE TomogRaphy (PIONEER) Study: 2-year Results

      Purpose To evaluate the feasibility, safety, and utility of intraoperative optical coherence tomography (OCT) for use during ophthalmic surgery. Design Prospective, consecutive, case series Methods A prospective, single-center, consecutive, case series was initiated to assess intraoperative OCT in ophthalmic surgery. Intraoperative scanning was performed with a microscope mounted spectral domain OCT system. Disease specific or procedure-specific imaging protocols (e.g., scan type, pattern, size, orientation, density) were utilized for anterior and posterior segment applications. A surgeon feedback form was recorded as part of the study protocol to answer specific questions regarding intraoperative OCT utility immediately after the surgical procedure was ...

      Read Full Article
      Mentions: Cleveland Clinic
    1-3 of 3
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (3 articles) Cleveland Clinic
    2. (1 articles) Leica
    3. (1 articles) Columbia University
    4. (1 articles) University of Rochester
    5. (1 articles) Stanford University
    6. (1 articles) Johns Hopkins University
    7. (1 articles) National University of Singapore
  3. Popular Articles

  4. Picture Gallery

    The Prospective Intraoperative and Perioperative Ophthalmic ImagiNg with Optical CoherEncE TomogRaphy (PIONEER) Study: 2-year Results Determination of Feasibility and Utility of Microscope-Integrated Optical Coherence Tomography During Ophthalmic Surgery The DISCOVER Study RESCAN Results The DISCOVER Study 3-Year Results Optical coherence tomography findings in patients with transfusion-dependent β-thalassemia Higher-order regression three-dimensional motion-compensation method for real-time optical coherence tomography volumetric imaging of the cornea Optical coherence tomography image based eye disease detection using deep convolutional neural network Optical Coherence Tomography Biomarkers in Predicting Treatment Outcomes of Diabetic Macular Edema After Dexamethasone Implants Macular and Optic Disc Parameters in Children with Amblyopic and Nonamblyopic Eyes under Optical Coherence Tomography Fundus Images Optical coherence tomography assessment of the enamel surface after debonding the ceramic brackets using three different techniques Schizophrenia in Translation: Why the Eye? Advances in OCT Imaging in Myopia and Pathologic Myopia Decision Trees for Glaucoma Screening Based on the Asymmetry of the Retinal Nerve Fiber Layer in Optical Coherence Tomography