1. Articles from Viquar U. Begum

    1-4 of 4
    1. Comparing Spectral-Domain Optical Coherence Tomography and Standard Automated Perimetry to Diagnose Glaucomatous Optic Neuropathy

      Comparing Spectral-Domain Optical Coherence Tomography and Standard Automated Perimetry to Diagnose Glaucomatous Optic Neuropathy

      Purpose: To compare the abilities of standard automated perimetry (SAP) and spectral-domain optical coherence tomography (SDOCT) in diagnosing eyes with glaucomatous optic neuropathy (GON). Methods: In a cross-sectional study, 280 eyes of 175 subjects referred to tertiary eye care center by general ophthalmologists for a glaucoma evaluation underwent retinal nerve fiber layer (RNFL) and ganglion cell complex (GCC) imaging with SDOCT. All subjects had at least 2 reliable and repeatable SAP. Two glaucoma experts masked to clinical and SAP results classified the optic nerves into GON and nonglaucomatous groups based on digital optic disc photographs. Ability of SDOCT parameters and ...

      Read Full Article
    2. Ganglion Cell-Inner Plexiform Layer Thickness of High Definition Optical Coherence Tomography in Perimetric and Preperimetric Glaucoma

      Ganglion Cell-Inner Plexiform Layer Thickness of High Definition Optical Coherence Tomography in Perimetric and Preperimetric Glaucoma

      Purpose. We determined the diagnostic performance of ganglion cell-inner plexiform layer (GCIPL) parameters of high definition optical coherence tomography (HD-OCT) in perimetric and preperimetric glaucoma, and compared it to optic nerve head (ONH) and peripapillary retinal nerve fiber layer (RNFL) parameters. Methods. In a cross-sectional study, 53 eyes of normal subjects and 83 eyes of glaucoma patients (62 perimetric and 21 preperimetric) from the Longitudinal Glaucoma Evaluation Study (LOGES) underwent HD-OCT imaging with Optic Disc and Macular Cube protocols. Diagnostic abilities of GCIPL, ONH, and RNFL parameters were determined using area under receiver operating characteristic curves (AUC) and likelihood ratios ...

      Read Full Article
    3. The ISNT rule in glaucoma: revisiting with spectral domain optical coherence tomography

      The ISNT rule in glaucoma: revisiting with spectral domain optical coherence tomography

      Purpose To evaluate the ability of the neuroretinal rim (NRR) rules determined using spectral domain optical coherence tomography (SDOCT) in diagnosing glaucoma and to study the effect of optic disc size and disease severity on the diagnostic ability of these rules. Methods In a cross-sectional study, 125 eyes of 96 glaucoma patients and 96 eyes of 72 control subjects underwent optic nerve head (ONH) imaging with SDOCT. Inferior (I), superior (S), nasal (N) and temporal (T) NRR areas were automatically determined by the sdoct software. Diagnostic abilities of ISNT (I > S > N > T), IT (I > T) and ST (S > T ...

      Read Full Article
    4. Reference Standard Test and the Diagnostic Ability of Spectral Domain Optical Coherence Tomography in Glaucoma

      Reference Standard Test and the Diagnostic Ability of Spectral Domain Optical Coherence Tomography in Glaucoma

      Purpose: To evaluate the relationship between the reference standard used to diagnose glaucoma and the diagnostic ability of spectral domain optical coherence tomograph (SDOCT). Methods: In a cross-sectional study, 280 eyes of 175 consecutive subjects, referred to a tertiary eye care center for glaucoma evaluation, underwent optic disc photography, visual field (VF) examination, and SDOCT examination. The cohort was divided into glaucoma and control groups based on 3 reference standards for glaucoma diagnosis: first based on the optic disc classification (179 glaucoma and 101 control eyes), second on VF classification (glaucoma hemifield test outside normal limits and pattern SD with ...

      Read Full Article
    1-4 of 4
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (4 articles) Ravi K. Yadav
    2. (4 articles) Uday K. Addepalli
    3. (4 articles) Sirisha Senthil
    4. (4 articles) Harsha L. Rao
    5. (3 articles) Nikhil S. Choudhari
    6. (2 articles) L V Prasad Eye Institute
    7. (1 articles) Optovue
    8. (1 articles) Alcon
    9. (1 articles) Fudan University
    10. (1 articles) UCLA
    11. (1 articles) University of Miami
    12. (1 articles) Capital Medical University
    13. (1 articles) VU University Amsterdam
    14. (1 articles) Srinivas R. Sadda
    15. (1 articles) Johannes F. de Boer
    16. (1 articles) Frank D. Verbraak
    17. (1 articles) Apollo Medical Optics
    18. (1 articles) Heidelberg Engineering
  3. Popular Articles

  4. Picture Gallery

    Reference Standard Test and the Diagnostic Ability of Spectral Domain Optical Coherence Tomography in Glaucoma The ISNT rule in glaucoma: revisiting with spectral domain optical coherence tomography Comparing Spectral-Domain Optical Coherence Tomography and Standard Automated Perimetry to Diagnose Glaucomatous Optic Neuropathy Ganglion Cell-Inner Plexiform Layer Thickness of High Definition Optical Coherence Tomography in Perimetric and Preperimetric Glaucoma Optical Coherence Tomography: Critical Tool to Manage Expectations after Cataract Extraction Improving the characterization of ex vivo human brain optical properties using high numerical aperture optical coherence tomography by spatially constraining the confocal parameters Choroidal, macular and ganglion cell layer thickness assessment in Caucasian children measured with spectral domain optical coherence tomography Examination of retinal vascular density changes via optical coherence tomography angiography in patients with glaucoma 3D reconstruction of coronary artery bifurcations from coronary angiography and optical coherence tomography: feasibility, validation, and reproducibility Age- and refraction-related changes in anterior segment anatomical structures measured by swept-source anterior segment OCT The evaluation of juvenile ocular hypertension by optical coherence tomography angiography Superficial capillary perfusion on optical coherence tomography angiography differentiates moderate and severe nonproliferative diabetic retinopathy