    1. Reproducibility and agreement of four anterior segment-optical coherence tomography devices for anterior chamber angle measurements

      Reproducibility and agreement of four anterior segment-optical coherence tomography devices for anterior chamber angle measurements

      Purpose To compare the reproducibility and agreement of anterior chamber angle (ACA) parameters and metrics obtained by four different anterior segment-optical coherence tomography (AS-OCT) devices. Methods In this prospective study, 30 eyes from 15 normal subjects underwent anterior segment angle scanning using the Spectralis, Cirrus, and Optovue spectral domain optical coherence tomography (SD-OCT), as well as the Visante time-domain optical coherence tomography (TD-OCT). For each eye, the scan line was performed perpendicularly on the inferior (270°) angle, and the inferior ACA image was acquired 2 times. Inter-instrument and intra-instrument, as well as inter-observer and intra-observer reproducibility of anterior chamber angle ...

      Read Full Article
    2. Reproducibility and Agreement Between 2 Spectral Domain Optical Coherence Tomography Devices for Anterior Chamber Angle Measurements

      Reproducibility and Agreement Between 2 Spectral Domain Optical Coherence Tomography Devices for Anterior Chamber Angle Measurements

      Purpose: To compare anterior chamber angle parameters based on the location of Schwalbe line (SL) from 2 spectral domain optical coherence tomography (SD-OCT) instruments and to measure their reproducibility. Methods: Forty-two eyes from 21 normal, healthy participants underwent imaging of the inferior irido-corneal angle with the Spectralis and Cirrus SD-OCT under tightly controlled low-light conditions. SL-angle opening distance (SL-AOD) and SL-trabecular iris space area (SL-TISA) were measured by masked, certified graders at the Doheny Imaging Reading Center using customized grading software. Interinstrument and intrainstrument, as well as interobserver and intraobserver reproducibility of SL-AOD and SL-TISA measurements were evaluated by intraclass ...

      Read Full Article
    3. Comparison of Physiologic versus Pharmacologic Mydriasis on Anterior Chamber Angle Measurements Using Spectral Domain Optical Coherence Tomography

      Comparison of Physiologic versus Pharmacologic Mydriasis on Anterior Chamber Angle Measurements Using Spectral Domain Optical Coherence Tomography

      Purpose. To compare the effects of physiologic versus pharmacologic pupil dilation on anterior chamber angle (ACA) measurements obtained with spectral domain optical coherence tomography (SD-OCT). Methods. Forty eyes from 20 healthy, phakic individuals with open angles underwent anterior segment OCT imaging under 3 pupillary states: (1) pupil constricted under standard room lighting, (2) physiologic mydriasis in a darkened room, and (3) postpharmacologic mydriasis. Inferior angle Schwalbe’s line-angle opening distance (SL-AOD) and SL-trabecular-iris-space area (SL-TISA) were computed for each eye and pupillary condition by masked, certified Reading Center graders using customized grading software. Results. SL-AOD and SL-TISA under pupillary constriction ...

      Read Full Article
    4. Effect of Angle of Incidence on Anterior Chamber Angle Metrics From Optical Coherence Tomography

      Effect of Angle of Incidence on Anterior Chamber Angle Metrics From Optical Coherence Tomography

      Purpose: To evaluate the local variability of anterior chamber angle (ACA) metrics obtained by time domain (TD) and spectral domain (SD) optical coherence tomography (OCT). Materials and Methods: Anterior-segment OCT imaging was performed on 30 normal eyes using Visante TD-OCT and 40 normal eyes using Cirrus SD-OCT. For Visante OCT, a single 16-mm line scan of the inferior angle with 3 slightly different rotations of 265, 270, and 275 degrees was performed. For Cirrus OCT, a 5-line raster of the inferior angle was performed, centering the third scan line at the 6 o'clock position, with 0.25 mm between ...

      Read Full Article
    5. Reproducibility of Anterior Segment Angle Metrics Measurements Derived From Cirrus Spectral Domain Optical Coherence Tomography

      Reproducibility of Anterior Segment Angle Metrics Measurements Derived From Cirrus Spectral Domain Optical Coherence Tomography

      Purpose: To investigate the reproducibility of anterior segment angle (ACA) metrics measurements in normal subjects on Cirrus spectral domain optical coherence tomography (SD-OCT). Methods: 40 eyes from 20 healthy, normal subjects underwent anterior segment imaging using a Cirrus SD-OCT. For each eye, 2 acquisitions of 5-line raster scans were performed perpendicularly on the inferior (270 degrees) angle. The Schwalbe's line-angle opening distance (SL-AOD) and Schwalbe's line-trabecular-iris space area (SL-TISA) measurements were performed by masked certified reading center graders using customized grading software. Intra-acquisition, intergrader, and intragrader reproducibility of SL-AOD and SL-TISA measurements were evaluated by intraclass correlation coefficients ...

      Read Full Article
    6. Reproducibility of Angle Metrics Using the Time-Domain Anterior Segment Optical Coherence Tomography: Intra-Observer and Inter-Observer Variability

      Reproducibility of Angle Metrics Using the Time-Domain Anterior Segment Optical Coherence Tomography: Intra-Observer and Inter-Observer Variability

      Purpose : To evaluate the reproducibility of anterior chamber angle measurements obtained by the Zeiss Visante anterior segment optical coherence tomography (AS-OCT). Methods : Twenty eyes from 20 normal subjects with open anterior chamber angles were studied. The anterior chamber angle was imaged using the Visante AS-OCT. The angle-opening distance (AOD 500, AOD 750), trabercular iris space area (TISA 500, TISA 750) and scleral spur angle (SS angle) at the inferior angle location were measured. All the subjects underwent imaging in a darkened room (1 foot candles measured at the eye). Images were graded in a masked fashion by certified Doheny Image ...

      Read Full Article
    1-6 of 6
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (6 articles) Srinivas R. Sadda
    2. (6 articles) Vikas Chopra
    3. (4 articles) UCLA
    4. (4 articles) Carl Zeiss Meditec
    5. (1 articles) UCSF
    6. (1 articles) University of Southern California
    7. (1 articles) Optovue
    8. (1 articles) Heidelberg Engineering
    9. (1 articles) British Columbia Cancer Agency
    10. (1 articles) Shanghai Jiao Tong University
    11. (1 articles) Singapore Eye Research Institute
    12. (1 articles) Simon Fraser University
    13. (1 articles) Columbia University
    14. (1 articles) Stephen Lam
    15. (1 articles) Pierre M. Lane
    16. (1 articles) Tien Yin Wong
    17. (1 articles) Giuseppe Querques
    18. (1 articles) Francesco Bandello
  3. Popular Articles

  4. Picture Gallery

    Reproducibility of Angle Metrics Using the Time-Domain Anterior Segment Optical Coherence Tomography: Intra-Observer and Inter-Observer Variability Reproducibility of Anterior Segment Angle Metrics Measurements Derived From Cirrus Spectral Domain Optical Coherence Tomography Effect of Angle of Incidence on Anterior Chamber Angle Metrics From Optical Coherence Tomography Comparison of Physiologic versus Pharmacologic Mydriasis on Anterior Chamber Angle Measurements Using Spectral Domain Optical Coherence Tomography Reproducibility and Agreement Between 2 Spectral Domain Optical Coherence Tomography Devices for Anterior Chamber Angle Measurements Reproducibility and agreement of four anterior segment-optical coherence tomography devices for anterior chamber angle measurements Line-field confocal optical coherence tomography-Practical applications in dermatology and comparison with established imaging methods Optical coherence tomography detection of changes in inner retinal and choroidal thicknesses in patients with early retinitis pigmentosa Feasibility of combined optical coherence tomography and autofluorescence imaging for visualization of needle biopsy placement Characterization of microvascular tortuosity in retinal vein occlusion utilizing optical coherence tomography angiography Evaluation of retinochoroidal tissues in third trimester pregnants: An optical coherence tomography angiography study Evaluation of retinal and choroidal variations in thyroid-associated ophthalmopathy using optical coherence tomography angiography