1. Articles from Yao-Jun Zhang

    1-11 of 11
    1. Optical coherence tomography enables more accurate detection of functionally significant intermediate non-left main coronary artery stenoses than intravascular ultrasound: A meta-analysis of 6919 patients and 7537 lesions

      Optical coherence tomography enables more accurate detection of functionally significant intermediate non-left main coronary artery stenoses than intravascular ultrasound: A meta-analysis of 6919 patients and 7537 lesions

      Objective Fractional flow reserve (FFR) is regarded as the gold standard for the physiological assessment of intermediate coronary artery stenoses. However, FFR does not allow assessment of plaque morphology and lesion geometry. Intracoronary imaging techniques such as intravascular ultrasound (IVUS) and optical coherence tomography (OCT) can help treatment planning by optimising stent implantation, which can improve patient outcomes. The aim of this meta-analysis is to compare the efficacy of IVUS and OCT-derived metrics in detecting flow limiting stenoses in non-left main stem lesions. Methods A systematic review of PubMed, Medline, and Cochrane databases was performed and identified studies examining the ...

      Read Full Article
    2. Optical coherence tomography assessment of a complex bifurcation lesion treated with double kissing Crush technique: A case report

      Optical coherence tomography assessment of a complex bifurcation lesion treated with double kissing Crush technique: A case report

      The DEFINITION (Impact of the complexity of bifurcation lesions treated with drug-eluting stents) study has provided a novel classification to evaluate the complexity of coronary bifurcation lesion according to coronary angiography, but angiographic imaging due to its low resolution and inherited limitation may result in an inaccurate adjudication. We used optical coherence tomography (OCT) to further evaluate the coronary characteristics in a patient with “simple” bifurcation lesion which was classified by the DEFINITION criteria. However, a “complex” bifurcation lesion was defined and confirmed according to the OCT results. A double kissing Crush stenting approach was adopted to treat this “complex ...

      Read Full Article
    3. Evaluation of vascular healing of polymer-free sirolimus-eluting stents in native coronary artery stenosis: a serial follow-up at three and six months with optical coherence tomography imaging

      Evaluation of vascular healing of polymer-free sirolimus-eluting stents in native coronary artery stenosis: a serial follow-up at three and six months with optical coherence tomography imaging

      Aims: Our aim was to assess vascular response after polymer-free sirolimus-eluting stent (SES) implantation by using an optical coherence tomography (OCT)-derived vascular healing score (HS), quantifying the deficiency of healing. Methods and results: In a prospective, multicentre, single-arm, open-label study, OCT examinations were performed at three months in 45 patients (47 lesions). Per protocol, 24 lesions which had not reached adequate vascular healing according to study criteria were scheduled for OCT examination at six months. The HS was calculated at two time points. Serial OCT imaging demonstrated that the proportion of covered stent struts increased from a median of ...

      Read Full Article
    4. Bioresorbable vascular scaffold treatment induces the formation of neointimal cap that seals the underlying plaque without compromising the luminal dimensions: a concept based on serial optical coherence tomography data

      Bioresorbable vascular scaffold treatment induces the formation of neointimal cap that seals the underlying plaque without compromising the luminal dimensions: a concept based on serial optical coherence tomography data

      Aims: To evaluate the implications of an Absorb bioresorbable vascular scaffold (Absorb BVS) on the morphology of the superficial plaques. Methods and results: Forty-six patients who underwent Absorb BVS implantation and 20 patients implanted with bare metal stents (BMS) who had serial optical coherence tomographic examination at baseline and follow-up were included in this analysis. The thin-capped fibroatheromas (TCFA) were identified in the device implantation regions and in the adjacent native coronary segments. Within all regions, circumferential locations of TCFA and calcific tissues were identified, and the neointimal thickness was measured at follow-up. At six to 12-month follow-up, only 8 ...

      Read Full Article
    5. Comparison of long-term in-stent vascular response between abluminal groove-filled biodegradable polymer sirolimus-eluting stent and durable polymer everolimus-eluting stent: 3-year OCT follow-up from the TARGET I trial

      Comparison of long-term in-stent vascular response between abluminal groove-filled biodegradable polymer sirolimus-eluting stent and durable polymer everolimus-eluting stent: 3-year OCT follow-up from the TARGET I trial

      The study sought to compare long-term optical coherence tomography (OCT)-based in-stent vascular response between the abluminal groove-filled biodegradable polymer sirolimus-eluting stent (SES) and the durable polymer everolimus-eluting stent (EES) in the TARGET I trial. The TARGET I trial was a prospective, multicenter, randomized clinical trial which enrolled 458 patients with single de novo lesions treated by abluminal groove-filled biodegradable polymer SES and EES. A subset of 43 patients underwent angiography and OCT examinations at 3 years. All OCT images were analyzed at 0.4 mm intervals. A similar increase in angiographic late lumen loss was observed in SES and ...

      Read Full Article
    6. Short-term effects of Nano+™ polymer-free sirolimus-eluting stents on native coronary vessels: an optical coherence tomography imaging study

      Short-term effects of Nano+™ polymer-free sirolimus-eluting stents on native coronary vessels: an optical coherence tomography imaging study

      Aims: Newly developed drug-eluting stents (DES) aim to promote early endothelialisation and prevent stent thrombosis. We sought to evaluate the extent of neointima growth by optical coherence tomography (OCT) three months after implantation of a polymer-free stent with a nano-sized-pore surface eluting sirolimus. Methods and results: In this prospective, multicentre, open-label study, patients were enrolled with documented stable angina or silent ischaemia and planned intervention for up to two de novo coronary lesions (in different vessels), with lesion length of ≤18 mm. The primary OCT endpoint was the percentage of in-stent neointimal volume obstruction at three months. The secondary endpoints ...

      Read Full Article
    7. Scaffold and Edge Vascular Response Following Implantation of Everolimus-Eluting Bioresorbable Vascular Scaffold : A 3-Year Serial Optical Coherence Tomography Study

      Scaffold and Edge Vascular Response Following Implantation of Everolimus-Eluting Bioresorbable Vascular Scaffold : A 3-Year Serial Optical Coherence Tomography Study

      Objectives This study sought to investigate the in-scaffold vascular response (SVR) and edge vascular response (EVR) after implantation of an everolimus-eluting bioresorbable scaffold (BRS) using serial optical coherence tomography (OCT) imaging. Background Although studies using intravascular ultrasound have evaluated the EVR in metal stents and BRSs, there is a lack of OCT-based SVR and EVR assessment after BRS implantation. Methods In the ABSORB Cohort B (ABSORB Clinical Investigation, Cohort B) study, 23 patients (23 lesions) in Cohort B1 and 17 patients (18 lesions) in Cohort B2 underwent truly serial OCT examinations at 3 different time points (Cohort B1: post-procedure, 6 ...

      Read Full Article
    8. Bioresorbable vascular scaffold treatment induces the formation of neointimal cap that seals the underlying plaque without compromising the luminal dimensions: a concept based on serial optical coherence tomography data

      Bioresorbable vascular scaffold treatment induces the formation of neointimal cap that seals the underlying plaque without compromising the luminal dimensions: a concept based on serial optical coherence tomography data

      Aims: To evaluate the implications of an Absorb bioresorbable vascular scaffold (Absorb BVS) on the morphology of the superficial plaques. Methods and results: Forty-six patients who underwent Absorb BVS implantation and 20 patients implanted with bare metal stents (BMS) who had serial optical coherence tomographic examination at baseline and follow-up were included in this analysis. The thin-capped fibroatheromas (TCFA) were identified in the device implantation regions and in the adjacent native coronary segments. Within all regions, circumferential locations of TCFA and calcific tissues were identified, and the neointimal thickness was measured at follow-up. At six to 12-month follow-up, only 8 ...

      Read Full Article
    9. Optical coherence tomography assessment of a PLGA-polymer with electro-grafting base layer versus a PLA-polymer sirolimus-eluting stent at three-month follow-up: the BuMA-OCT randomised trial

      Optical coherence tomography assessment of a PLGA-polymer with electro-grafting base layer versus a PLA-polymer sirolimus-eluting stent at three-month follow-up: the BuMA-OCT randomised trial

      Aims: To compare stent strut coverage using optical coherence tomography (OCT) at three-month follow-up between a PLGA-polymer with electro-grafting base layer sirolimus-eluting stent (SES) (BuMA) and a PLA-polymer SES (EXCEL). Methods and results: This prospective, single-centre, non-inferiority randomised BuMA-OCT trial enrolled patients with de novo coronary artery lesions, treated with either the BuMA or the EXCEL stent. The study primary endpoint was OCT-evaluated stent strut coverage at three months. Secondary endpoints were neointimal thickness of stent struts, and incomplete stent apposition evaluated with OCT. A total of 80 patients were randomly assigned to receive the BuMA (n=40) or the ...

      Read Full Article
    10. Effect of the Endothelial Shear Stress Patterns on Neointimal Proliferation Following Drug-Eluting Bioresorbable Vascular Scaffold Implantation : An Optical Coherence Tomography Study

      Effect of the Endothelial Shear Stress Patterns on Neointimal Proliferation Following Drug-Eluting Bioresorbable Vascular Scaffold Implantation : An Optical Coherence Tomography Study

      Objectives The goal of this study was to investigate the effect of endothelial shear stress (ESS) on neointimal formation following an Absorb bioresorbable vascular scaffold (BVS) (Abbott Vascular, Santa Clara, California) implantation. Background Cumulative evidence, derived from intravascular ultrasound–based studies, has demonstrated a strong association between local ESS patterns and neointimal formation in bare-metal stents, whereas in drug-eluting stents, there are contradictory data about the effect of ESS on the vessel wall healing process. The effect of ESS on neointimal development following a bioresorbable scaffold implantation remains unclear. Methods Twelve patients with an obstructive lesion in a relatively straight ...

      Read Full Article
    11. Fusion of optical coherence tomographic and angiographic data for more accurate evaluation of the endothelial shear stress patterns and neointimal distribution after bioresorbable scaffold implantation: comparison with intravascular ultrasound-derived rec

      Fusion of optical coherence tomographic and angiographic data for more accurate evaluation of the endothelial shear stress patterns and neointimal distribution after bioresorbable scaffold implantation: comparison with intravascular ultrasound-derived rec

      Intravascular ultrasound (IVUS)-based reconstructions have been traditionally used to examine the effect of endothelial shear stress (ESS) on neointimal formation. The aim of this analysis is to compare the association between ESS and neointimal thickness (NT) in models obtained by the fusion of optical coherence tomography (OCT) and coronary angiography and in the reconstructions derived by the integration of IVUS and coronary angiography. We analyzed data from six patients implanted with an Absorb bioresorbable vascular scaffold that had biplane angiography, IVUS and OCT investigation at baseline and 6 or 12 months follow-up. The IVUS and OCT follow-up data were ...

      Read Full Article
    1-11 of 11
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (9 articles) Erasmus University
    2. (8 articles) Patrick W. Serruys
    3. (8 articles) Yoshinobu Onuma
    4. (7 articles) Christos V. Bourantas
    5. (7 articles) Hector M. Garcia-Garcia
    6. (3 articles) Roberto Diletti
    7. (3 articles) Vasim Farooq
    8. (3 articles) Robert-Jan van Geuns
    9. (3 articles) Richard Rapoza
    10. (2 articles) Brigham and Women’s Hospital
  3. Popular Articles

  4. Picture Gallery

    Fusion of optical coherence tomographic and angiographic data for more accurate evaluation of the endothelial shear stress patterns and neointimal distribution after bioresorbable scaffold implantation: comparison with intravascular ultrasound-derived rec Effect of the Endothelial Shear Stress Patterns on Neointimal Proliferation Following Drug-Eluting Bioresorbable Vascular Scaffold Implantation : An Optical Coherence Tomography Study Optical coherence tomography assessment of a PLGA-polymer with electro-grafting base layer versus a PLA-polymer sirolimus-eluting stent at three-month follow-up: the BuMA-OCT randomised trial Bioresorbable vascular scaffold treatment induces the formation of neointimal cap that seals the underlying plaque without compromising the luminal dimensions: a concept based on serial optical coherence tomography data Scaffold and Edge Vascular Response Following Implantation of Everolimus-Eluting Bioresorbable Vascular Scaffold : A 3-Year Serial Optical Coherence Tomography Study Short-term effects of Nano+™ polymer-free sirolimus-eluting stents on native coronary vessels: an optical coherence tomography imaging study Comparison of long-term in-stent vascular response between abluminal groove-filled biodegradable polymer sirolimus-eluting stent and durable polymer everolimus-eluting stent: 3-year OCT follow-up from the TARGET I trial Bioresorbable vascular scaffold treatment induces the formation of neointimal cap that seals the underlying plaque without compromising the luminal dimensions: a concept based on serial optical coherence tomography data Evaluation of vascular healing of polymer-free sirolimus-eluting stents in native coronary artery stenosis: a serial follow-up at three and six months with optical coherence tomography imaging Optical coherence tomography assessment of a complex bifurcation lesion treated with double kissing Crush technique: A case report Retinal Vascular Features in Ocular Blunt Trauma by Optical Coherence Tomography Angiography Non-invasive imaging of a choroidal macrovessel