1. Articles from Dries De Cock

    1-8 of 8
    1. Optical Coherence Tomography Findings in Patients with Coronary Stent Thrombosis: A Report of the PREvention of Late Stent Thrombosis by an Interdisciplinary Global European Effort (PRESTIGE) Consortium

      Optical Coherence Tomography Findings in Patients with Coronary Stent Thrombosis: A Report of the PREvention of Late Stent Thrombosis by an Interdisciplinary Global European Effort (PRESTIGE) Consortium

      Background —Stent thrombosis (ST) is a serious complication following coronary stenting. Intravascular optical coherence tomography (OCT) may provide insights into mechanistic processes leading to ST. We performed a prospective, multicenter study to evaluate OCT findings in patients with ST. Methods —Consecutive patients presenting with ST were prospectively enrolled in a registry using a centralized telephone registration system. After angiographic confirmation of ST, OCT imaging of the culprit vessel was performed with frequency domain OCT. Clinical data were collected according to a standardized protocol. OCT acquisitions were analyzed at a core laboratory. Dominant and contributing findings were adjudicated by an imaging ...

      Read Full Article
    2. COmplex coronary Bifurcation lesions: RAndomized comparison of a strategy using a dedicated self-expanding biolimus-eluting stent versus a culotte strategy using everolimus-eluting stents: primary results of the COBRA trial

      COmplex coronary Bifurcation lesions: RAndomized comparison of a strategy using a dedicated self-expanding biolimus-eluting stent versus a culotte strategy using everolimus-eluting stents: primary results of the COBRA trial

      Aims: We aimed to compare healing responses with optical coherence tomography, and clinical and angiographic outcome after treatment of coronary bifurcation lesions with a dedicated stent versus aconventional culotte technique. Methods and results: Forty patients with true and complex coronary bifurcation lesions were randomly assigned to treatment with the Axxess™ bifurcation stent in the proximal main vessel (MV) and additional BioMatrix™ stents in the branches (Biosensors Europe SA, Morges, Switzerland), versus a culotte technique using XIENCE™ stents (Abbott Vascular, Santa Clara, CA, USA). The primary endpoint of percentage of uncovered struts at nine months was similar with the dedicated strategy ...

      Read Full Article
      Mentions: K. U. Leuven
    3. STACCATO (Assessment of Stent sTrut Apposition and Coverage in Coronary ArTeries with Optical coherence tomography in patients with STEMI, NSTEMI and stable/unstable angina undergoing everolimus vs. biolimus A9-eluting stent implantation): a randomised co

      STACCATO (Assessment of Stent sTrut Apposition and Coverage in Coronary ArTeries with Optical coherence tomography in patients with STEMI, NSTEMI and stable/unstable angina undergoing everolimus vs. biolimus A9-eluting stent implantation): a randomised co

      Aims: To compare tissue coverage in coronary lesions stented with durable fluoropolymer-coated everolimus-eluting stents (EES) vs. biodegradable polymer-coated biolimus A9-eluting stents (BES). Methods and results: Sixty-four patients (64 lesions) with de novo coronary artery lesions were randomised to percutaneous treatment with XIENCE® EES (Abbott Vascular, Santa Clara, CA, USA) vs. BioMatrix™ BES (Biosensors, Morges, Switzerland). The primary endpoint was the percentage of uncovered struts, as assessed with OCT, at nine months. The average percentage of uncovered struts was significantly lower with EES (4.3±4.8% vs. 8.7±7.8% with BES, p=0.019). There was no difference ...

      Read Full Article
      Mentions: K. U. Leuven
    4. Automated detection and quantification of clusters of malapposed and uncovered intracoronary stent struts assessed with optical coherence tomography

      Automated detection and quantification of clusters of malapposed and uncovered intracoronary stent struts assessed with optical coherence tomography

      To date, accurate quantification and localization of malapposed and uncovered struts needs manual and time consuming analysis of large datasets. To develop an algorithm for automated detection and quantification of clusters of malapposed and uncovered struts in optical coherence tomography (OCT) pullbacks, including comprehensive information about their three-dimensional spatial distribution. 64 lesions in 64 patients treated with drug-eluting stent underwent assessment with OCT immediately after implantation and at 9-month follow-up (55 patients). An automated algorithm was used to detect and quantify stent strut malapposition at baseline and coverage at follow-up on an individual strut level. We subsequently applied an algorithm ...

      Read Full Article
      Mentions: K. U. Leuven
    5. Healing course of acute vessel wall injury after drug-eluting stent implantation assessed by optical coherence tomography

      Healing course of acute vessel wall injury after drug-eluting stent implantation assessed by optical coherence tomography

      BACKGROUND: Vessel wall injury after drug-eluting stent (DES) implantation can be characterized in detail by optical coherence tomography (OCT). Little is known about the healing course of these phenomena. METHODS AND RESULTS: In 62 lesions (62 patients), the incidence of acute vessel trauma was assessed in the stented region and the edge segments immediately after DES implantation. The healing course of these injuries was assessed at 9-month OCT follow-up using a software algorithm allowing for reliable spatial comparison of baseline and follow-up cross-sectional images. Tissue prolapse (TP) and tissue protrusions were detected in 81 and 35% of lesions, respectively. A ...

      Read Full Article
      Mentions: K. U. Leuven
    6. Detailed in vivo visualization of stent fracture causing focal restenosis using 3D reconstruction software for high-resolution optical coherence tomography images

      Detailed in vivo visualization of stent fracture causing focal restenosis using 3D reconstruction software for high-resolution optical coherence tomography images

      A 55-year-old female underwent repeat coronary angiography for recurrent angina, 9 months after percutaneous coronary intervention (PCI) of a mid-right coronary artery (RCA) chronic total occlusion with implantation of two overlapping Orsiro™ sirolimus-eluting stents (3.0 × 30 mm at 20 atm; 2.5 × 30 mm at 16 atm) (see Supplementary data online, Video S1). The distal part of the stented segment showed a focal in-stent restenosis (ISR) with the abnormal motion pattern (see Supplementary data online, Video S2). Optical coherence tomography (OCT) with 3D reconstruction confirmed suspected stent

      Read Full Article
      Mentions: K. U. Leuven
    1-8 of 8
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (7 articles) K. U. Leuven
    2. (1 articles) Technical University of Munich
    3. (1 articles) Academic Medical Center at the University of Amsterdam
    4. (1 articles) Azienda Ospedaliera San Paolo
    5. (1 articles) Ludwig Maximilian University of Munich
  3. Popular Articles

  4. Picture Gallery

    Detailed in vivo visualization of stent fracture causing focal restenosis using 3D reconstruction software for high-resolution optical coherence tomography images Healing course of acute vessel wall injury after drug-eluting stent implantation assessed by optical coherence tomography Automated detection and quantification of clusters of malapposed and uncovered intracoronary stent struts assessed with optical coherence tomography Unusual stent fracture: diagnosis with optical coherence tomography STACCATO (Assessment of Stent sTrut Apposition and Coverage in Coronary ArTeries with Optical coherence tomography in patients with STEMI, NSTEMI and stable/unstable angina undergoing everolimus vs. biolimus A9-eluting stent implantation): a randomised co COmplex coronary Bifurcation lesions: RAndomized comparison of a strategy using a dedicated self-expanding biolimus-eluting stent versus a culotte strategy using everolimus-eluting stents: primary results of the COBRA trial Unusual stent fracture: diagnosis with optical coherence tomography Optical Coherence Tomography Findings in Patients with Coronary Stent Thrombosis: A Report of the PREvention of Late Stent Thrombosis by an Interdisciplinary Global European Effort (PRESTIGE) Consortium The truth about invisible posterior vitreous structures Increased Macrophage-like Cell Density in Retinal Vein Occlusion as Characterized by en Face Optical Coherence Tomography The Influence of Eyelid Position and Environmental Conditions on the Corneal Changes in Early Postmortem Interval: A Prospective, Multicentric OCT Study The Use of Optical Coherence Tomography for Gross Examination and Sampling of Fixed Breast Specimens: A Pilot Study