1. Articles from Ming-Che Chan

    1-4 of 4
    1. Ultrahigh-resolution optical coherence tomography/angiography with an economic and compact supercontinuum laser

      Ultrahigh-resolution optical coherence tomography/angiography with an economic and compact supercontinuum laser

      In this study, a Q-switch pumped supercontinuum laser (QS-SCL) is used as a light source for in vivo imaging via ultrahigh-resolution optical coherence tomography and angiography (UHR-OCT/OCTA). For this purpose, an OCT system based on a spectral-domain detection scheme is constructed, and a spectrometer with a spectral range of 635 − 875 nm is designed. The effective full-width at half maximum of spectrum covers 150 nm, and the corresponding axial and transverse resolutions are 2 and 10 µm in air, respectively. The relative intensity noise of the QS-SCL and mode-locked SCL is quantitatively compared. Furthermore, a special processing algorithm is ...

      Read Full Article
    2. Optical coherence tomography-guided laser microsurgery for blood coagulation with continuous-wave laser diode

      Optical coherence tomography-guided laser microsurgery for blood coagulation with continuous-wave laser diode

      Blood coagulation is the clotting and subsequent dissolution of the clot following repair to the damaged tissue. However, inducing blood coagulation is difficult for some patients with homeostasis dysfunction or during surgery. In this study, we proposed a method to develop an integrated system that combines optical coherence tomography (OCT) and laser microsurgery for blood coagulation. Also, an algorithm for positioning of the treatment location from OCT images was developed. With OCT scanning, 2D/3D OCT images and angiography of tissue can be obtained simultaneously, enabling to noninvasively reconstruct the morphological and microvascular structures for real-time monitoring of changes in ...

      Read Full Article
    3. Simultaneous 0.8, 1.0, and 1.3um multispectral and common-path broadband source for optical coherence tomography

      Simultaneous 0.8, 1.0, and 1.3um multispectral and common-path broadband source for optical coherence tomography

      Simultaneous multispectral generation in 0.8, 1.0, and 1.3 μm wavelength ranges by efficient energy conversions of 1.0 μm wavelength femtosecond pulses through a nonlinear fiber was reported. The output spectral range of this multispectral light source was composed of 0.6–0.9 μm blue-shifted Cherenkov radiation (CR), 1.0 μm residual pump, and 1.1–1.7 μm red-shifted soliton self-frequency shift (SSFS) with more than 1     mW / nm power-spectral densities. Output characteristics of the multispectral light source were then quantitatively analyzed and the central wavelengths of CR and SSFS emissions can be further easily ...

      Read Full Article
    4. Ultrahigh-Resolution Optical Coherence Tomography with LED-Phosphor-Based Broadband Light Source

      Ultrahigh-Resolution Optical Coherence Tomography with LED-Phosphor-Based Broadband Light Source

      This study proposed and demonstrated the potential use of LED phosphors as a simple light source for ultrahigh-resolution spectral-domain optical coherence tomography (SD-OCT) in the visible regime. Excited by a 405 nm diode laser, broadband spontaneous emission from three different LED phosphors was generated. The best axial resolution was 1.7 µm in air, and finally, corresponding three-dimensional (3D) ultrahigh-resolution SD-OCT imaging was performed with the proposed broadband light source.

      Read Full Article
    1-4 of 4
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (4 articles) Chang Gung University
    2. (1 articles) National Taiwan University
    3. (1 articles) Capital Medical University
  3. Popular Articles

  4. Picture Gallery

    Ultrahigh-Resolution Optical Coherence Tomography with LED-Phosphor-Based Broadband Light Source Simultaneous 0.8, 1.0, and 1.3um multispectral and common-path broadband source for optical coherence tomography Optical coherence tomography-guided laser microsurgery for blood coagulation with continuous-wave laser diode Ultrahigh-resolution optical coherence tomography/angiography with an economic and compact supercontinuum laser Trojan-Horse Diameter-Reducible Nanotheranostics for Macroscopic/Microscopic Imaging-Monitored Chemo-Antiangiogenic Therapy Thickness of retinal pigment epithelium–Bruch’s membrane complex in adult Chinese using optical coherence tomography Interocular symmetry of optical coherence tomography parameters in healthy children and adolescents Fluorescein Leakage and Optical Coherence Tomography Angiography Features of Microaneurysms in Diabetic Retinopathy Cross-free in both lateral and axial directions Fourier-domain full-field optical coherence tomography Microperimetry, Humphrey field analyzer, and optical coherence tomography in detecting glaucoma: a comparative performance study Scanning optimization of an electrothermally-actuated MEMS mirror for applications in optical coherence tomography endoscopy Near-infrared active superparamagnetic iron oxide nanoparticles for magnetomotive optical coherence tomography imaging and magnetic hyperthermia therapeutic applications