    1. Cataract quantification using swept-source optical coherence tomography

      Cataract quantification using swept-source optical coherence tomography

      Purpose To develop and evaluate a cataract quantification method using a swept-source optical coherence tomography (SS-OCT) device (IOLMaster 700). Setting Hanusch Hospital, Vienna, Austria. Design Prospective multicenter case series. Methods This study included patients with cataract in at least 1 eye. Two independent examiners performed Lens Opacities Classification System II (LOCS II) grading at the slitlamp independently. Corrected distance visual acuity, contrast sensitivity, and SS-OCT measurements were also performed. In addition, the phacoemulsification energy and time were recorded. To develop an objective SS-OCT-based cataract quantification system, all SS-OCT scans were segmented and the local pixel intensity unit of the lens ...

      Read Full Article
      Mentions: Oliver Findl
    2. Intraoperative optical coherence tomography measurements of aphakic eyes to predict postoperative position of 2 intraocular lens designs

      Intraoperative optical coherence tomography measurements of aphakic eyes to predict postoperative position of 2 intraocular lens designs

      Purpose To evaluate intraoperative anterior chamber depth (ACD) measurements of the aphakic eye to predict the postoperative ACD and compare 2 intraocular lens (IOL) designs. Setting Hanusch Hospital, Vienna, Austria. Design Prospective study. Methods In this prospective study, patients scheduled for cataract surgery received a plate-haptic IOL (Asphina, Carl Zeiss Meditec AG) or an open-loop haptic IOL (ZCB00, Johnson & Johnson). Preoperatively, optical biometry (IOLMaster 700, CZM, or Lenstar, Haag-Streit) was performed. Intraoperatively, a prototype setup was used to perform time-domain OCT scans of the anterior eye segment (Visante connected to OPMI Lumera 200, both CZM). The intraoperative ACD was measured ...

      Read Full Article
      Mentions: Oliver Findl
    3. Prediction of postoperative intraocular lens tilt using swept-source optical coherence tomography

      Prediction of postoperative intraocular lens tilt using swept-source optical coherence tomography

      Purpose To compare crystalline lens tilt in eyes before and intraocular lens (IOL) tilt in eyes after cataract surgery using swept-source optical coherence tomography (SS-OCT) (IOLMaster 700). Setting Hanusch Hospital, Vienna, Austria. Design Prospective case series. Methods Patients' eyes were scanned 1 week before and 2 months after cataract surgery with IOL implantation using an SS-OCT device. This device performs B-scans along 6 meridians (0, 30, 60, 90, 120, and 150 degrees) to determine lens and IOL tilt. Results Sixty-two eyes (62 patients) were included in the analysis. The mean magnitude and direction of tilt showed mirror symmetry between both ...

      Read Full Article
    4. Using continuous intraoperative optical coherence tomography to classify swirling lens fragments during cataract surgery and to predict their impact on corneal endothelial cell damage

      Using continuous intraoperative optical coherence tomography to classify swirling lens fragments during cataract surgery and to predict their impact on corneal endothelial cell damage

      Purpose To quantify and classify swirling lens fragments during cataract surgery and record their impact on the corneal endothelium using continuous intraoperative optical coherence tomography (OCT). Setting Vienna Institute for Ocular Surgery, Hanusch Hospital, Vienna, Austria. Design Prospective case series. Methods Patients scheduled for cataract surgery without other ophthalmologic comorbidities were included. During surgery, continuous OCT recordings were performed to measure and score swirling lens fragments that came into contact with the corneal endothelium. Endothelial cell density (ECD) was measured preoperatively and 1 month postoperatively. In addition, the central corneal thickness and aqueous flare were measured preoperatively and 1 hour ...

      Read Full Article
    5. Macular disease detection with a swept-source optical coherence tomography-based biometry device in patients scheduled for cataract surgery

      Macular disease detection with a swept-source optical coherence tomography-based biometry device in patients scheduled for cataract surgery

      Purpose To assess the sensitivity and specificity for detecting macular disease with a new optical biometry device with swept-source optical coherence tomography (SS-OCT) used before cataract surgery. Setting Hanusch Hospital, Vienna, Austria. Design Consecutive case series. Methods This study included patients with or without macular disease. All patients were scanned using the new biometry device (IOLMaster 700), which allows a 1.0 mm central retinal scan using SS-OCT technology. Also, all eyes were assessed using a dedicated retinal OCT device (RTVue) on the same day. Two experienced examiners and 1 ophthalmology resident graded all scans individually. Sensitivity and specificity for ...

      Read Full Article
    6. Visualizing Macular Structures During Membrane Peeling Surgery With an Intraoperative Spectral-Domain Optical Coherence Tomography Device

      Visualizing Macular Structures During Membrane Peeling Surgery With an Intraoperative Spectral-Domain Optical Coherence Tomography Device

      BACKGROUND AND OBJECTIVE: The aim of this study was to examine the quality of intraoperative visualization of the posterior hyaloid, epiretinal membrane (ERM), inner limiting membrane (ILM), and hyporeflective subfoveal zone with a commercially available, microscope-integrated spectral-domain OCT setup (mi-SD-OCT) (Rescan 700; Carl Zeiss Meditec AG, Germany). PATIENTS AND METHODS: Twenty patients prospectively scheduled for pars plana vitrectomy with membrane peeling due to an idiopathic ERM were included. Standard 23-gauge, three-port pars plana vitrectomy with membrane peeling and staining of the ERM with a trypan blue-based chromovitrectomy dye was performed in all cases. Intraoperative SD-OCT was performed before and after ...

      Read Full Article
    7. Macular disease detection with a swept-source optical coherence tomography-based biometry device in patients scheduled for cataract surgery

      Macular disease detection with a swept-source optical coherence tomography-based biometry device in patients scheduled for cataract surgery

      Purpose To assess the sensitivity and specificity for detecting macular disease with a new optical biometry device with swept-source optical coherence tomography (SS-OCT) used before cataract surgery. Setting Hanusch Hospital, Vienna, Austria. Design Consecutive case series. Methods This study included patients with or without macular disease. All patients were scanned using the new biometry device (IOLMaster 700), which allows a 1.0 mm central retinal scan using SS-OCT technology. Also, all eyes were assessed using a dedicated retinal OCT device (RTVue) on the same day. Two experienced examiners and 1 ophthalmology resident graded all scans individually. Sensitivity and specificity for ...

      Read Full Article
    8. Prediction of Residual Astigmatism After Cataract Surgery Using Swept Source Fourier Domain Optical Coherence Tomography

      Prediction of Residual Astigmatism After Cataract Surgery Using Swept Source Fourier Domain Optical Coherence Tomography

      Purpose : To compare corneal measurements obtained by a swept source fourier domain OCT (CASIA SS-1000), an autokeratometer (Haag-Streit Lenstar), a hybrid topographer (Tomey TMS-5), a Placido topographer (Tomey TMS-5 in Placido mode) and a Scheimpflug tomographer (Oculus Pentacam) to manifest subjective refraction. Methods : One hundred and four pseudophacic patients with non-toric IOLs were measured at least 6 months after surgery . Corneal astigmatism as measured on the anterior corneal surface as well as total corneal astigmatism including posterior surface data was compared to manifest refractive cylinder (cross-cylinder strategy) by computing difference vectors and correlation analysis of power vectors. Results : The OCT ...

      Read Full Article
    9. Using continuous intraoperative optical coherence tomography measurements of the aphakic eye for intraocular lens power calculation

      Using continuous intraoperative optical coherence tomography measurements of the aphakic eye for intraocular lens power calculation

      Background/aims To include intraoperative measurements of the anterior lens capsule of the aphakic eye into the intraocular lens power calculation (IPC) process and to compare the refractive outcome with conventional IPC formulae. Methods In this prospective study, a prototype operating microscope with an integrated continuous optical coherence tomography (OCT) device (Visante attached to OPMI VISU 200, Carl Zeiss Meditec AG, Germany) was used to measure the anterior lens capsule position after implanting a capsular tension ring (CTR). Optical biometry (intraocular lens (IOL) Master 500) and ACMaster measurements (Carl Zeiss Meditec AG, Germany) were performed before surgery. Autorefraction and subjective ...

      Read Full Article
    10. Predicting the Postoperative Intraocular Lens Position Using Continuous Intraoperative Optical Coherence Tomography Measurements

      Predicting the Postoperative Intraocular Lens Position Using Continuous Intraoperative Optical Coherence Tomography Measurements

      Purpose. The aim of this study was to assess, if measuring the position of the lens capsule intraoperatively with a continuous intraoperative optical coherence tomography (OCT) device could be useful to improve the prediction of the intraocular lens (IOL) position. Methods. This prospective study included patients who were scheduled for cataract surgery. A prototype operating microscope with an integrated continuous OCT device was used to measure the anterior and posterior lens capsule position at different time points during cataract surgery. In all cases, a capsular tension ring (CTR) was used to tauten the lens capsule. Partial coherence interferometry was used ...

      Read Full Article
      Mentions: Oliver Findl
    11. Predicting the post-operative intraocular lens position using continuous intra-operative optical coherence tomography measurements

      Predicting the post-operative intraocular lens position using continuous intra-operative optical coherence tomography measurements

      Purpose: Aim of this study was to assess, if measuring the position of the lens capsule intra-operatively with a continuous intra-operative optical coherence tomography (OCT) device could be useful to improve the prediction of the IOL position. Methods: This prospective study included patients who were scheduled for cataract surgery. A prototype operating microscope with an integrated continuous OCT device (Visante attached to OPMI VISU 200, Carl Zeiss Meditec AG, Germany) was used to measure the anterior and posterior lens capsule position at different time points during cataract surgery. In all cases a capsular tension ring (CTR) was used to tauten ...

      Read Full Article
    1-11 of 11
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (9 articles) Oliver Findl
    2. (4 articles) Carl Zeiss Meditec
    3. (2 articles) Optovue RTVue-100
    4. (1 articles) Klaus Hoffmann
    5. (1 articles) Tomey Corporation
    6. (1 articles) Haag-Streit
    7. (1 articles) Duke University
    8. (1 articles) Sina Farsiu
    9. (1 articles) PhotoniCare
  3. Popular Articles

  4. Picture Gallery

    Predicting the post-operative intraocular lens position using continuous intra-operative optical coherence tomography measurements Predicting the Postoperative Intraocular Lens Position Using Continuous Intraoperative Optical Coherence Tomography Measurements Using continuous intraoperative optical coherence tomography measurements of the aphakic eye for intraocular lens power calculation Prediction of Residual Astigmatism After Cataract Surgery Using Swept Source Fourier Domain Optical Coherence Tomography Visualizing Macular Structures During Membrane Peeling Surgery With an Intraoperative Spectral-Domain Optical Coherence Tomography Device Macular disease detection with a swept-source optical coherence tomography-based biometry device in patients scheduled for cataract surgery Macular disease detection with a swept-source optical coherence tomography-based biometry device in patients scheduled for cataract surgery Using continuous intraoperative optical coherence tomography to classify swirling lens fragments during cataract surgery and to predict their impact on corneal endothelial cell damage Prediction of postoperative intraocular lens tilt using swept-source optical coherence tomography Intraoperative optical coherence tomography measurements of aphakic eyes to predict postoperative position of 2 intraocular lens designs Duke University Engineering Professor Sina Farsiu Elected Fellow of the IEEE PhotoniCare Takes First Place at the 2019 HealthTECH Startup Competition