1. Articles from Jin Wang

    1-5 of 5
    1. A FBG-OCT Catheter to reconstruct vascular shape in intravascular optical coherence tomography

      A FBG-OCT Catheter to reconstruct vascular shape in intravascular optical coherence tomography

      We propose a novel Fiber Bragg Grating (FBG)-Optical Coherence Tomography (OCT) catheter to reconstruct vascular shape by intravascular OCT imaging of the actual curvature as well as the bending direction of the vascular in real-time. Compared with the traditional OCT catheter, the FBG-OCT catheter uses the FBG encapsulated with half-sectioned stainless-steel tube as a flexural sensitive component. With the 360-degree rotation of the catheter, the encapsulated FBG will produce maximum tension and maximum compression at the bend of the blood vessel, and then get the solution of the curvature and direction of the bending catheter as well as the ...

      Read Full Article
      Mentions: Tiegen Liu
    2. Scaffold and Edge Vascular Response Following Implantation of Everolimus-Eluting Bioresorbable Vascular Scaffold : A 3-Year Serial Optical Coherence Tomography Study

      Scaffold and Edge Vascular Response Following Implantation of Everolimus-Eluting Bioresorbable Vascular Scaffold : A 3-Year Serial Optical Coherence Tomography Study

      Objectives This study sought to investigate the in-scaffold vascular response (SVR) and edge vascular response (EVR) after implantation of an everolimus-eluting bioresorbable scaffold (BRS) using serial optical coherence tomography (OCT) imaging. Background Although studies using intravascular ultrasound have evaluated the EVR in metal stents and BRSs, there is a lack of OCT-based SVR and EVR assessment after BRS implantation. Methods In the ABSORB Cohort B (ABSORB Clinical Investigation, Cohort B) study, 23 patients (23 lesions) in Cohort B1 and 17 patients (18 lesions) in Cohort B2 underwent truly serial OCT examinations at 3 different time points (Cohort B1: post-procedure, 6 ...

      Read Full Article
    3. Effect of the Endothelial Shear Stress Patterns on Neointimal Proliferation Following Drug-Eluting Bioresorbable Vascular Scaffold Implantation : An Optical Coherence Tomography Study

      Effect of the Endothelial Shear Stress Patterns on Neointimal Proliferation Following Drug-Eluting Bioresorbable Vascular Scaffold Implantation : An Optical Coherence Tomography Study

      Objectives The goal of this study was to investigate the effect of endothelial shear stress (ESS) on neointimal formation following an Absorb bioresorbable vascular scaffold (BVS) (Abbott Vascular, Santa Clara, California) implantation. Background Cumulative evidence, derived from intravascular ultrasound–based studies, has demonstrated a strong association between local ESS patterns and neointimal formation in bare-metal stents, whereas in drug-eluting stents, there are contradictory data about the effect of ESS on the vessel wall healing process. The effect of ESS on neointimal development following a bioresorbable scaffold implantation remains unclear. Methods Twelve patients with an obstructive lesion in a relatively straight ...

      Read Full Article
    4. Fusion of optical coherence tomographic and angiographic data for more accurate evaluation of the endothelial shear stress patterns and neointimal distribution after bioresorbable scaffold implantation: comparison with intravascular ultrasound-derived rec

      Fusion of optical coherence tomographic and angiographic data for more accurate evaluation of the endothelial shear stress patterns and neointimal distribution after bioresorbable scaffold implantation: comparison with intravascular ultrasound-derived rec

      Intravascular ultrasound (IVUS)-based reconstructions have been traditionally used to examine the effect of endothelial shear stress (ESS) on neointimal formation. The aim of this analysis is to compare the association between ESS and neointimal thickness (NT) in models obtained by the fusion of optical coherence tomography (OCT) and coronary angiography and in the reconstructions derived by the integration of IVUS and coronary angiography. We analyzed data from six patients implanted with an Absorb bioresorbable vascular scaffold that had biplane angiography, IVUS and OCT investigation at baseline and 6 or 12 months follow-up. The IVUS and OCT follow-up data were ...

      Read Full Article
    5. Study on effective probe depth of optical coherence tomography system by Monte Carlo simulation

      Study on effective probe depth of optical coherence tomography system by Monte Carlo simulation

      The intensities of Class I and Class II signals at several different probing depths and different coherence lengths are analyzed using a Monte Carlo model with a pencil beam, and the result shows that the longitudinal resolution has influence on the effective probe depth. A Monte Carlo model for optical coherence tomography system with a focused Gaussian beam is proposed. The intensities of Class I and Class II signals at different probing depth for different radius and depth of focus of the beam are simulated using this model. We found that increasing of the depth of focus and decreasing of ...

      Read Full Article
    1-5 of 5
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (3 articles) Erasmus University
    2. (3 articles) Patrick W. Serruys
    3. (3 articles) Christos V. Bourantas
    4. (3 articles) Hector M. Garcia-Garcia
    5. (3 articles) Yoshinobu Onuma
    6. (2 articles) Harvard University
    7. (2 articles) University of Ioannina
    8. (2 articles) Brigham and Women’s Hospital
    9. (2 articles) Takashi Muramatsu
    10. (1 articles) Tianjin University
  3. Popular Articles

  4. Picture Gallery

    Study on effective probe depth of optical coherence tomography system by Monte Carlo simulation Fusion of optical coherence tomographic and angiographic data for more accurate evaluation of the endothelial shear stress patterns and neointimal distribution after bioresorbable scaffold implantation: comparison with intravascular ultrasound-derived rec Effect of the Endothelial Shear Stress Patterns on Neointimal Proliferation Following Drug-Eluting Bioresorbable Vascular Scaffold Implantation : An Optical Coherence Tomography Study Scaffold and Edge Vascular Response Following Implantation of Everolimus-Eluting Bioresorbable Vascular Scaffold : A 3-Year Serial Optical Coherence Tomography Study A FBG-OCT Catheter to reconstruct vascular shape in intravascular optical coherence tomography Postdoctoral Fellow / Research Fellow at The Australian National University, Canberra Stress, anxiety, harassment: huge survey reveals pressures of scientists’ working lives Use of optical coherence tomography deemed feasible after first-in-human analysis Widefield Swept Source OCTA in Retinitis Pigmentosa Anterior segment optical coherence tomographic characterisation of keratic precipitate Vascular changes with optical coherence tomography angiography during aura of migraine: A case report Numerical method for axial motion artifact correction in retinal spectral-domain optical coherence tomography