    1. In Vivo Near Infrared Virtual Intraoperative Surgical Photoacoustic Optical Coherence Tomography

      In Vivo Near Infrared Virtual Intraoperative Surgical Photoacoustic Optical Coherence Tomography

      Since its first implementation in otolaryngological surgery nearly a century ago, the surgical microscope has improved the accuracy and the safety of microsurgeries. However, the microscope shows only a magnified surface view of the surgical region. To overcome this limitation, either optical coherence tomography (OCT) or photoacoustic microscopy (PAM) has been independently combined with conventional surgical microscope. Herein, we present a near-infrared virtual intraoperative photoacoustic optical coherence tomography (NIR-VISPAOCT) system that combines both PAM and OCT with a conventional surgical microscope. Using optical scattering and absorption, the NIR-VISPAOCT system simultaneously provides surgeons with real-time comprehensive biological information such as tumor ...

      Read Full Article
    2. Two-axis polydimethylsiloxane-based electromagnetic microelectromechanical system scanning mirror for optical coherence tomography

      Two-axis polydimethylsiloxane-based electromagnetic microelectromechanical system scanning mirror for optical coherence tomography

      Compact size and fast imaging abilities are key requirements for the clinical implementation of an optical coherence tomography (OCT) system. Among the various small-sized technology, a microelectromechanical system (MEMS) scanning mirror is widely used in a miniaturized OCT system. However, the complexities of conventional MEMS fabrication processes and relatively high costs have restricted fast clinical translation and commercialization of the OCT systems. To resolve these problems, we developed a two-axis polydimethylsiloxane (PDMS)-based MEMS (2A-PDMS-MEMS) scanning mirror through simple processes with low costs. It had a small size of 15 × 15 × 15    mm 3 15×15×15  mm3 , was fast ...

      Read Full Article
    3. A 2-axis Polydimethylsiloxane (PDMS) based electromagnetic MEMS scanning mirror for optical coherence tomography

      A 2-axis Polydimethylsiloxane (PDMS) based electromagnetic MEMS scanning mirror for optical coherence tomography

      Optical coherence tomography (OCT) is a noninvasive imaging tool for visualizing cross-sectional images of biological tissues on a microscale. Various microelectromechanical system (MEMS) techniques have been applied to OCT for endoscopic catheters and handheld probes. Despite having several advantages such as compact sizes and high speeds for real-time imaging, the complexities of the fabrication processes and relatively high costs were bottlenecks for fast clinical translation and commercialization of the earlier MEMS scanners. To overcome these issues, we developed a 2-axis polydimethylsiloxane (PDMS)-based electromagnetic MEMS scanning mirror based on flexible, cost-effective, and handleable PDMS. The size of this MEMS scanner ...

      Read Full Article
    4. Microscope System, And Method For Providing Augmented Reality Images Of Microscope System

      Microscope System, And Method For Providing Augmented Reality Images Of Microscope System

      Provided is a microscope system. The system comprises: an optical microscope unit for collecting a surface image of an object to be examined; an OCT unit for collecting an optical coherence tomography image of the object to be examined; a PA unit for collecting a photoacoustic image of the object to be examined; an image processing unit for generating an augmented reality image by superimposing the optical coherence tomography image and the photoacoustic image over the surface image; and an image observation unit for making the augmented reality image visible.

      Read Full Article
    5. Stimulated penetrating keratoplasty using real-time virtual intraoperative surgical optical coherence tomography

      Stimulated penetrating keratoplasty using real-time virtual intraoperative surgical optical coherence tomography

      An intraoperative surgical microscope is an essential tool in a neuro- or ophthalmological surgical environment. Yet, it has an inherent limitation to classify subsurface information because it only provides the surface images. To compensate for and assist in this problem, combining the surgical microscope with optical coherence tomography (OCT) has been adapted. We developed a real-time virtual intraoperative surgical OCT (VISOCT) system by adapting a spectral-domain OCT scanner with a commercial surgical microscope. Thanks to our custom-made beam splitting and image display subsystems, the OCT images and microscopic images are simultaneously visualized through an ocular lens or the eyepiece of ...

      Read Full Article
    6. Combined photoacoustic and optical coherence tomography using a single near-infrared supercontinuum laser source

      Combined photoacoustic and optical coherence tomography using a single near-infrared supercontinuum laser source

      . We developed an integrated dual-modal photoacoustic and optical coherence tomography (PA-OCT) system using a single near-infrared supercontinuum laser source to simultaneously provide both optical absorption and scattering contrasts. A pulsed broadband supercontinuum source was generated by a pulsed Nd:YAG laser and a photonic-crystal fiber. When we imaged two colored hairs, the black hair was visible in both PA and OCT images, whereas the white hair was only mapped in the OCT image. The single laser source will potentially allow us to implement relatively simple, cheap, and compact dual-modal PA-OCT systems, which are key criteria for fast clinical translation and ...

      Read Full Article
    7. Dual-modal photoacoustic and optical coherence tomography using a single near-infrared supercontinuum laser source

      Dual-modal photoacoustic and optical coherence tomography using a single near-infrared supercontinuum laser source

      We report the development of a combined dual-modal photoacoustic and optical coherence tomography (PA-OCT) system using a single near-infrared (NIR) supercontinuum laser source which can provide both optical absorption and scattering contrasts simultaneously. By using a small sized pulsed Nd:YAG microchip laser and a photonic crystal fiber, we fabricated a pulsed broadband supercontinuum source from 600 to 1700 nm. Under the same optical hardware system, intrinsically registered PA and OCT images are acquired in a single scanning. In order to demonstrate feasibility of our system, we successfully acquired the PA and OCT images of black and white hairs images ...

      Read Full Article
    1-7 of 7
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (7 articles) Jeehyun Kim
    2. (7 articles) Changho Lee
    3. (6 articles) Kyungpook National University
    4. (2 articles) State University of New York at Buffalo
    5. (2 articles) Mansik Jeon
    6. (1 articles) University of Ulsan
    7. (1 articles) Qifa Zhou
    8. (1 articles) Min Yong Jeon
    9. (1 articles) Harvard University
    10. (1 articles) Massachusetts General Hospital
    11. (1 articles) University of North Carolina
    12. (1 articles) Baylor College of Medicine
    13. (1 articles) Masamichi Takano
    14. (1 articles) Joel S. Schuman
    15. (1 articles) Ik-Kyung Jang
    16. (1 articles) Yoshiyasu Minami
    17. (1 articles) Donald L. Budenz
    18. (1 articles) Gadi Wollstein
  3. Popular Articles

  4. Picture Gallery

    Dual-modal photoacoustic and optical coherence tomography using a single near-infrared supercontinuum laser source Combined photoacoustic and optical coherence tomography using a single near-infrared supercontinuum laser source Stimulated penetrating keratoplasty using real-time virtual intraoperative surgical optical coherence tomography Microscope System, And Method For Providing Augmented Reality Images Of Microscope System A 2-axis Polydimethylsiloxane (PDMS) based electromagnetic MEMS scanning mirror for optical coherence tomography Two-axis polydimethylsiloxane-based electromagnetic microelectromechanical system scanning mirror for optical coherence tomography In Vivo Near Infrared Virtual Intraoperative Surgical Photoacoustic Optical Coherence Tomography High space-bandwidth in quantitative phase imaging using partially spatially coherent optical coherence microscopy and deep neural network Optical coherence tomography assessment of macrophages accumulation in non-ST-segment elevation acute coronary syndromes Early disability in ambulatory patients with multiple sclerosis: optical coherence tomography versus visual evoked potentials, a comparative study Dueling Deep Q-Network for Unsupervised Inter-frame Eye Movement Correction in Optical Coherence Tomography Volumes Atlas of Optical Coherence Tomography for Glaucoma (Textbook)