    1. Neoatherosclerosis in Patients With Coronary Stent Thrombosis: Findings From Optical Coherence Tomography Imaging (A Report of the PRESTIGE Consortium)

      Neoatherosclerosis in Patients With Coronary Stent Thrombosis: Findings From Optical Coherence Tomography Imaging (A Report of the PRESTIGE Consortium)

      Objectives The purpose of this study was to assess neoatherosclerosis in a registry of prospectively enrolled patients presenting with stent thrombosis using optical coherence tomography . Background In-stent neoatherosclerosis was recently identified as a novel disease manifestation of atherosclerosis after coronary stent implantation. Methods Angiography and intravascular optical coherence tomography were used to investigate etiologic factors of neoatherosclerosis in patients presenting with stent thrombosis >1 year after implantation (very late stent thrombosis [VLST]). Clinical data were collected according to a standardized protocol. Optical coherence tomographic acquisitions were analyzed in a core laboratory. Cox regression analysis was performed to identify factors associated ...

      Read Full Article
    2. Randomised comparison of vascular response to biodegradable polymer sirolimus eluting and permanent polymer everolimus eluting stents: An optical coherence tomography study

      Randomised comparison of vascular response to biodegradable polymer sirolimus eluting and permanent polymer everolimus eluting stents: An optical coherence tomography study

      Background Drug-eluting stents with biodegradable polymer coatings have shown promising outcomes in randomised studies. Methods We compared neointimal healing patterns including strut coverage and assessed neointimal maturity using a novel algorithm in coronary lesions treated with sirolimus-eluting stents with biodegradable polymer coating (BP-SES) or everolimus eluting stents with permanent polymer coating (PP-EES) using optical coherence tomography after 6 months. Results A total of 39 patients were randomised to BP-SES ( n = 19) or PP-EES ( n = 20) for the treatment of coronary lesions. Of those, 29 patients (14 BP-SES and 15 PP-EES) underwent optical coherence tomography (OCT) and angiography at 6-month follow-up ...

      Read Full Article
    3. Optical Coherence Tomography Findings in Patients with Coronary Stent Thrombosis: A Report of the PREvention of Late Stent Thrombosis by an Interdisciplinary Global European Effort (PRESTIGE) Consortium

      Optical Coherence Tomography Findings in Patients with Coronary Stent Thrombosis: A Report of the PREvention of Late Stent Thrombosis by an Interdisciplinary Global European Effort (PRESTIGE) Consortium

      Background —Stent thrombosis (ST) is a serious complication following coronary stenting. Intravascular optical coherence tomography (OCT) may provide insights into mechanistic processes leading to ST. We performed a prospective, multicenter study to evaluate OCT findings in patients with ST. Methods —Consecutive patients presenting with ST were prospectively enrolled in a registry using a centralized telephone registration system. After angiographic confirmation of ST, OCT imaging of the culprit vessel was performed with frequency domain OCT. Clinical data were collected according to a standardized protocol. OCT acquisitions were analyzed at a core laboratory. Dominant and contributing findings were adjudicated by an imaging ...

      Read Full Article
    4. Randomized comparison of biolimus-eluting stents with biodegradable polymer versus everolimus-eluting stents with permanent polymer coatings assessed by optical coherence tomography

      Randomized comparison of biolimus-eluting stents with biodegradable polymer versus everolimus-eluting stents with permanent polymer coatings assessed by optical coherence tomography

      We sought to compare the healing patterns of biolimus-eluting stents with biodegradable polymer (BP-BES, Nobori) versus everolimus-eluting stents with permanent polymer (PP-EES, Xience) using intravascular optical coherence tomography (OCT). A total of 34 patients undergoing treatment of de novo coronary lesions were randomly assigned to receive BP-BES (n = 15) or PP-EES (n = 19). Stent tissue coverage and apposition as well as the incidence of peri-strut low intensity area (PLIA) were assessed by OCT at 6–8 months. Generalized linear mixed models were used to account for clustered data. OCT imaging was available for 17 lesions with 2,805 struts in ...

      Read Full Article
    5. Tissue Characterization After Drug-Eluting Stent Implantation Using Optical Coherence Tomography

      Tissue Characterization After Drug-Eluting Stent Implantation Using Optical Coherence Tomography

      Objective— To validate optical coherence tomography (OCT) imaging for assessment of vascular healing in a preclinical animal model and human autopsy cases and to translate the findings to the assessment of vascular healing after drug-eluting stent implantation in clinical practice. Approach and Results— Drug-eluting stent and bare metal stents were imaged 28 and 42 days after implantation in atherosclerotic rabbits using OCT and simultaneously evaluated by histology. After coregistration with histology, gray-scale signal intensity (GSI) was measured for identified mature or immature neointimal tissue. Autopsy specimens were imaged with OCT and GSI values correlated with histology. Finally, prospective OCT imaging ...

      Read Full Article
    6. Early vascular healing with rapid breakdown biodegradable polymer sirolimus-eluting versus durable polymer everolimus-eluting stents assessed by optical coherence tomography

      Early vascular healing with rapid breakdown biodegradable polymer sirolimus-eluting versus durable polymer everolimus-eluting stents assessed by optical coherence tomography

      Background Differences in early arterial healing patterns after stent implantation between biodegradable and durable polymer based new generation drug-eluting stents are not well understood. The aim of this study was to compare the healing patterns of a novel rapid breakdown (≤ 8 weeks) biodegradable polymer sirolimus-eluting stent (BP-SES) with a durable polymer everolimus-eluting stent (EES) using intravascular optical coherence tomography (OCT) at 4 months. Methods A total of 20 patients were randomly assigned to stenting with BP-SES (n = 11) or EES (n = 9). Overall intravascular imaging was available for 15 (75%) patients. The primary endpoint was the difference in rate of ...

      Read Full Article
    1-6 of 6
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (4 articles) Technical University of Munich
    2. (3 articles) K. U. Leuven
    3. (3 articles) Ludwig Maximilian University of Munich
    4. (2 articles) Azienda Ospedaliera San Paolo
    5. (1 articles) Ospedali Riuniti di Bergamo
    6. (1 articles) Wakayama Medical University
  3. Popular Articles

  4. Picture Gallery

    Early vascular healing with rapid breakdown biodegradable polymer sirolimus-eluting versus durable polymer everolimus-eluting stents assessed by optical coherence tomography Tissue Characterization After Drug-Eluting Stent Implantation Using Optical Coherence Tomography Randomized comparison of biolimus-eluting stents with biodegradable polymer versus everolimus-eluting stents with permanent polymer coatings assessed by optical coherence tomography Optical Coherence Tomography Findings in Patients with Coronary Stent Thrombosis: A Report of the PREvention of Late Stent Thrombosis by an Interdisciplinary Global European Effort (PRESTIGE) Consortium Randomised comparison of vascular response to biodegradable polymer sirolimus eluting and permanent polymer everolimus eluting stents: An optical coherence tomography study Neoatherosclerosis in Patients With Coronary Stent Thrombosis: Findings From Optical Coherence Tomography Imaging (A Report of the PRESTIGE Consortium) The truth about invisible posterior vitreous structures Increased Macrophage-like Cell Density in Retinal Vein Occlusion as Characterized by en Face Optical Coherence Tomography The Influence of Eyelid Position and Environmental Conditions on the Corneal Changes in Early Postmortem Interval: A Prospective, Multicentric OCT Study The Use of Optical Coherence Tomography for Gross Examination and Sampling of Fixed Breast Specimens: A Pilot Study The Role of Widefield and Ultra Widefield Optical Coherence Tomography in the Diagnosis and Management of Vitreoretinal Diseases Acute Idiopathic Blind Spot Enlargement Syndrome-New Perspectives in the OCT Era