1. Articles from Sujin Hoshi

    1-8 of 8
    1. Quantitative Evaluation of Phase Retardation in Filtering Blebs Using Polarization-Sensitive Optical Coherence Tomography

      Quantitative Evaluation of Phase Retardation in Filtering Blebs Using Polarization-Sensitive Optical Coherence Tomography

      Purpose : Polarization-sensitive optical coherence tomography (PS-OCT) can detect and evaluate scar fibrosis of the filtering blebs after glaucoma surgery. Although the change in phase retardation reportedly reflects bleb function, quantitative assessment of phase retardation in ocular tissues has not been conducted. We aimed to establish quantitative methods to investigate changes in phase retardation in the blebs after surgery using PS-OCT. Methods : Twenty-two blebs of 22 patients who had undergone glaucoma filtration surgery were consecutively examined for 4 months. Phase retardation was measured by PS-OCT and quantitatively analyzed to evaluate its relationship with bleb function based on intraocular pressure and medication ...

      Read Full Article
    2. Objective Evaluation of Functionality of Filtering Bleb Based on Polarization-Sensitive Optical Coherence Tomography

      Objective Evaluation of Functionality of Filtering Bleb Based on Polarization-Sensitive Optical Coherence Tomography

      Purpose : The fibrosis score is a new diagnostic score that we have developed to evaluate the function of bleb structures after glaucoma filtration surgery using polarization-sensitive optical coherence tomography (PS-OCT). This study aims to assess the efficacy of the fibrosis score in discriminating nonfunctional from the functional blebs. Methods : A total of 20 patients who had undergone glaucoma filtration surgery were imaged at different time periods after surgery using PS-OCT. Birefringence tomography of blebs was obtained from PS-OCT, and the fibrosis score was computed for each patient. The fibrosis score is defined as the area of occupation of high birefringence ...

      Read Full Article
    3. Repeatability of Corneal Phase Retardation Measurements by Polarization-Sensitive Optical Coherence Tomography

      Repeatability of Corneal Phase Retardation Measurements by Polarization-Sensitive Optical Coherence Tomography

      Purpose. Polarization-sensitive optical coherence tomography (PS-OCT) can evaluate internal tissue structures of the cornea, such as collagen fibers, by phase retardation measurement. In this study, we assessed the repeatability of corneal phase retardation measurements using anterior segment PS-OCT. Methods. A total of 173 eyes of 173 patients were measured using PS-OCT. In total, 58 eyes of young subjects with normal corneas, 28 eyes of old subjects with normal corneas, 26 eyes with corneal dystrophy or degeneration, 37 eyes with corneal transplantation, and 24 eyes with keratoconus were evaluated. The 3-mm diameter average of en face phase retardation of the posterior ...

      Read Full Article
    4. Noninvasive Evaluation of Phase Retardation in Blebs after Glaucoma Surgery Using Anterior Segment Polarization-Sensitive Optical Coherence Tomography

      Noninvasive Evaluation of Phase Retardation in Blebs after Glaucoma Surgery Using Anterior Segment Polarization-Sensitive Optical Coherence Tomography

      Purpose: Evaluation of bleb morphology using anterior segment optical coherence tomography (OCT) can offer important information regarding bleb function after glaucoma surgery. However, analysis of tissue properties, such as scar fibrosis of blebs, is difficult with conventional OCT. The birefringence of the blebs as susceptible measure of fibrosis scar was evaluated using polarization-sensitive OCT (PS-OCT) and its relation with bleb function was assessed. Methods: One hundred and fifty-three blebs of 122 patients that had undergone trabeculectomy or an Ex-Press tube shunt were examined. Also, in 14 blebs of 12 patients, consecutive measurements were performed for 2 months after surgery. The ...

      Read Full Article
    5. Three-dimensional volumetric human meibomian gland investigation using polarization-sensitive optical coherence tomography

      Three-dimensional volumetric human meibomian gland investigation using polarization-sensitive optical coherence tomography

      In this study, polarization-sensitive optical coherence tomography (PS-OCT) capable of providing polarization contrasts such as phase retardation and degree of polarization uniformity (DOPU) was used for visualizing human meibomian glands (MGs) and investigating morphological characteristics of them. Especially, with the help of the DOPU contrast, MGs were exclusively extracted from the volumetric OCT image. In vivo PS-OCT measurements were performed on the upper eyelids of different age groups. From these measurements, different age-dependent aspects of the MG structure were also observed. Based on these observations, it can be inferred that the PS-OCT system has the potential for clinical diagnosis and ...

      Read Full Article
    6. Comparison of three-dimensional optical coherence tomography and combining a rotating Scheimpflug camera with a Placido topography system for forme fruste keratoconus diagnosis

      Comparison of three-dimensional optical coherence tomography and combining a rotating Scheimpflug camera with a Placido topography system for forme fruste keratoconus diagnosis

      Objective To evaluate the ability of parameters measured by three-dimensional (3D) corneal and anterior segment optical coherence tomography (CAS-OCT) and a rotating Scheimpflug camera combined with a Placido topography system (Scheimpflug camera with topography) to discriminate between normal eyes and forme fruste keratoconus. Methods Forty-eight eyes of 48 patients with keratoconus, 25 eyes of 25 patients with forme fruste keratoconus and 128 eyes of 128 normal subjects were evaluated. Anterior and posterior keratometric parameters (steep K, flat K, average K), elevation, topographic parameters, regular and irregular astigmatism (spherical, asymmetry, regular and higher-order astigmatism) and five pachymetric parameters (minimum, minimum–median ...

      Read Full Article
    7. Comparison of three-dimensional optical coherence tomography and combining a rotating Scheimpflug camera with a Placido topography system for forme fruste keratoconus diagnosis

      Comparison of three-dimensional optical coherence tomography and combining a rotating Scheimpflug camera with a Placido topography system for forme fruste keratoconus diagnosis

      Objective To evaluate the ability of parameters measured by three-dimensional (3D) corneal and anterior segment optical coherence tomography (CAS-OCT) and a rotating Scheimpflug camera combined with a Placido topography system (Scheimpflug camera with topography) to discriminate between normal eyes and forme fruste keratoconus. Methods Forty-eight eyes of 48 patients with keratoconus, 25 eyes of 25 patients with forme fruste keratoconus and 128 eyes of 128 normal subjects were evaluated. Anterior and posterior keratometric parameters (steep K, flat K, average K), elevation, topographic parameters, regular and irregular astigmatism (spherical, asymmetry, regular and higher-order astigmatism) and five pachymetric parameters (minimum, minimum–median ...

      Read Full Article
    8. Keratoconus diagnosis using anterior segment polarization-sensitive optical coherence tomography

      Keratoconus diagnosis using anterior segment polarization-sensitive optical coherence tomography

      Purpose: To investigate the tissue properties of keratoconic corneas and normal control in vivo by using polarization-sensitive optical coherence tomography (PS-OCT) and evaluate early keratoconus by the area under the receiver-operating curve and Mahalanobis distances analysis. Methods: Thirty one eyes of 20 patients with keratoconus, seven eyes of four patients with keratoconus suspect, and 25 eyes of 25 normal subjects were investigated by PS-OCT and corneal and anterior segment (CAS)-OCT. Average of en face phase retardation of the posterior surface of the cornea, curvature, videokeratographic parameters, regular and irregular astigmatism, pachymetry map, and elevation were measured. The AROC of ...

      Read Full Article
    1-8 of 8
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (8 articles) University of Tsukuba
    2. (8 articles) Yoshiaki Yasuno
    3. (4 articles) Deepa K. Kasaragod
    4. (3 articles) Masahiro Yamanari
    5. (2 articles) Columbia University
    6. (2 articles) Christine P. Hendon
    7. (2 articles) Canon Medical Systems
    8. (1 articles) Institute of Applied Physics
    9. (1 articles) University of British Columbia
    10. (1 articles) Gwangju Institute of Science and Technology
    11. (1 articles) Byeong Ha Lee
    12. (1 articles) Tomey Corporation
    13. (1 articles) Tomey SS-1000 CASIA
    14. (1 articles) University of Houston
    15. (1 articles) Kyoto University Graduate School of Medicine
    16. (1 articles) Dmitry A. Terpelov
    17. (1 articles) David D. Sampson
    18. (1 articles) Eric A. Swanson
    19. (1 articles) Akitaka Tsujikawa
    20. (1 articles) Kirill V. Larin
  3. Popular Articles

  4. Picture Gallery

    Keratoconus diagnosis using anterior segment polarization-sensitive optical coherence tomography Comparison of three-dimensional optical coherence tomography and combining a rotating Scheimpflug camera with a Placido topography system for forme fruste keratoconus diagnosis Comparison of three-dimensional optical coherence tomography and combining a rotating Scheimpflug camera with a Placido topography system for forme fruste keratoconus diagnosis Three-dimensional volumetric human meibomian gland investigation using polarization-sensitive optical coherence tomography Noninvasive Evaluation of Phase Retardation in Blebs after Glaucoma Surgery Using Anterior Segment Polarization-Sensitive Optical Coherence Tomography Repeatability of Corneal Phase Retardation Measurements by Polarization-Sensitive Optical Coherence Tomography Objective Evaluation of Functionality of Filtering Bleb Based on Polarization-Sensitive Optical Coherence Tomography Quantitative Evaluation of Phase Retardation in Filtering Blebs Using Polarization-Sensitive Optical Coherence Tomography Miniaturizing medical imaging, sensing technology On-chip tunable photonic delay line Canon Xephilio OCT-A1 Optical Coherence Tomography Device Receives FDA 510(k) Clearance Subintimal Versus Intraplaque Recanalization of Coronary Chronic Total Occlusions: Mid-Term Angiographic and OCT Findings From the ISAR-OCT-CTO Registry