1. Articles from Maarten J. Suttorp

    1-3 of 3
    1. Optical coherence tomography findings: insights from the “randomised multicentre trial investigating angiographic outcomes of hybrid sirolimus-eluting stents with biodegradable polymer compared with everolimus-eluting stents with durable polymer in chroni

      Optical coherence tomography findings: insights from the “randomised multicentre trial investigating angiographic outcomes of hybrid sirolimus-eluting stents with biodegradable polymer compared with everolimus-eluting stents with durable polymer in chroni

      Aims: The PRISON IV trial investigated the next-generation sirolimus-eluting stent (SES) with ultra-thin struts and biodegradable polymer against the second-generation everolimus-eluting stent (EES) with thin struts and durable polymer in patients with successfully recanalised chronic total occlusions (CTO). In this study, we examined the secondary optical coherence tomography endpoints. Methods and results: The main PRISON IV trial randomised 330 patients to either SES or EES. At nine months, 281 (85%) patients underwent repeat angiography. Of these, 60 consecutive patients received optical coherence tomography divided over both stent groups. The mean number of struts analysed was 750±337 and 633±358 ...

      Read Full Article
    2. Optical coherence tomography findings: insights from the “randomised multicentre trial investigating angiographic outcomes of hybrid sirolimus-eluting stents with biodegradable polymer compared with everolimus-eluting stents with durable polymer in chroni

      Optical coherence tomography findings: insights from the “randomised multicentre trial investigating angiographic outcomes of hybrid sirolimus-eluting stents with biodegradable polymer compared with everolimus-eluting stents with durable polymer in chroni

      Aims: The PRISON IV trial investigated the next-generation sirolimus-eluting stent (SES) with ultra-thin struts and biodegradable polymer against the second-generation everolimus-eluting stent (EES) with thin struts and durable polymer in patients with successfully recanalised chronic total occlusions (CTO). In this study, we examined the secondary optical coherence tomography endpoints. Methods and results: The main PRISON IV trial randomised 330 patients to either SES or EES. At nine months, 281 (85%) patients underwent repeat angiography. Of these, 60 consecutive patients received optical coherence tomography divided over both stent groups. The mean number of struts analysed was 750±337 and 633±358 ...

      Read Full Article
    3. A randomized multicenter comparison of hybrid sirolimus-eluting stents with bioresorbable polymer versus everolimus-eluting stents with durable polymer in total coronary occlusion: rationale and design of the Primary Stenting of Occluded Native Coronary A

      A randomized multicenter comparison of hybrid sirolimus-eluting stents with bioresorbable polymer versus everolimus-eluting stents with durable polymer in total coronary occlusion: rationale and design of the Primary Stenting of Occluded Native Coronary A

      Background Percutaneous recanalization of total coronary occlusion (TCO) was historically hampered by high rates of restenosis and reocclusions. The PRISON II trial demonstrated a significant restenosis reduction in patients treated with sirolimus-eluting stents compared with bare metal stents for TCO. Similar reductions in restenosis were observed with the second-generation zotarolimus-eluting stent and everolimus-eluting stent. Despite favorable anti-restenotic efficacy, safety concerns evolved after identifying an increased rate of very late stent thrombosis (VLST) with drug-eluting stents (DES) for the treatment of TCO. Late malapposition caused by hypersensitivity reactions and chronic inflammation was suggested as a probable cause of these VLST. New ...

      Read Full Article
      Mentions: Tom Adriaenssens
    1-3 of 3
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (3 articles) Tom Adriaenssens
    2. (2 articles) Academic Medical Center at the University of Amsterdam
    3. (2 articles) K. U. Leuven
    4. (2 articles) Walter Desmet
    5. (2 articles) Giovanni J. Ughi
    6. (2 articles) Carl Zeiss Meditec
    7. (1 articles) Arnaud Dubois
    8. (1 articles) University of Missouri
    9. (1 articles) Johns Hopkins University
    10. (1 articles) Technical University of Munich
    11. (1 articles) UCSD
    12. (1 articles) University of Cambridge
    13. (1 articles) University of Rochester
    14. (1 articles) Gang Yao
    15. (1 articles) Taiji Sakamoto
    16. (1 articles) Heidelberg Engineering
  3. Popular Articles

  4. Picture Gallery

    A randomized multicenter comparison of hybrid sirolimus-eluting stents with bioresorbable polymer versus everolimus-eluting stents with durable polymer in total coronary occlusion: rationale and design of the Primary Stenting of Occluded Native Coronary A Optical coherence tomography findings: insights from the “randomised multicentre trial investigating angiographic outcomes of hybrid sirolimus-eluting stents with biodegradable polymer compared with everolimus-eluting stents with durable polymer in chroni Optical coherence tomography findings: insights from the “randomised multicentre trial investigating angiographic outcomes of hybrid sirolimus-eluting stents with biodegradable polymer compared with everolimus-eluting stents with durable polymer in chroni MULTIMODAL IMAGING CORRELATION OF THE CONCENTRIC MACULAR RINGS SIGN IN FOVEAL HYPOPLASIA Temporal dynamics of muscle optical properties during degeneration and regeneration in a canine muscle xenograft model Anterior Segment Optical Coherence Tomography in Ocular Argyrosis Automatic intraoperative optical coherence tomography positioning Anatomical features and clinical outcome of a honeycomb-like structure in the coronary artery: reports from 16 consecutive patients 3D-printed corals could improve bioenergy and help coral reefs Photonics Europe Digital Forum: silicon photonics to make waves beyond telecoms Indiana University Receives NIH Grant for Imaging Spatial and Temporal Dynamics of Retinal Ganglion Cells University of Houston Receives NIH Grant for Structural and Molecular Phenotyping of Embryonic Development Through Multi-Modal Optical Imaging.