1. Articles from Lesya M. Shuba

    1-4 of 4
    1. Asymmetry analysis of macular optical coherence tomography angiography in patients with glaucoma and healthy subjects

      Asymmetry analysis of macular optical coherence tomography angiography in patients with glaucoma and healthy subjects

      Background/aims Quantitative analysis of optical coherence tomography angiography (OCT-A) images requires a reproducible approach that accounts for sectoral loss. The objective of this study was to determine whether an index that accounts for both global (perfusion density, PD) and asymmetric loss of perfusion, rather than PD alone, more reliably measures loss of perfusion in patients with glaucoma. Methods We analysed macular OCT-A scans of 95 glaucoma patients and 59 control subjects. Two-dimensional projection images corresponding to the superficial vascular plexus were exported and analyses performed to calculate global PD and image asymmetry. An unsigned perfusion asymmetry index (PAI) that ...

      Read Full Article
    2. Diagnostic Accuracy of Optical Coherence Tomography and Scanning Laser Tomography for Identifying Glaucoma in Myopic Eyes

      Diagnostic Accuracy of Optical Coherence Tomography and Scanning Laser Tomography for Identifying Glaucoma in Myopic Eyes

      Purpose Ruling out glaucoma in myopic eyes often poses a diagnostic challenge because of atypical optic disc morphology and visual field defects that can mimic glaucoma. We determined whether neuroretinal rim assessment based on Bruch's membrane opening (BMO), rather than conventional optic disc margin (DM)-based assessment or retinal nerve fiber layer (RNFL) thickness, yielded higher diagnostic accuracy in myopic patients with glaucoma. Design Case-control, cross-sectional study. Participants Myopic patients with glaucoma (n = 56) and myopic normal controls (n = 74). Methods Myopic subjects with refraction error greater than −2 diopters (D) (spherical equivalent) and typical myopic optic disc morphology ...

      Read Full Article
    3. Laminar Displacement and Prelaminar Tissue Thickness Change after Glaucoma Surgery Imaged with Optical Coherence Tomography

      Laminar Displacement and Prelaminar Tissue Thickness Change after Glaucoma Surgery Imaged with Optical Coherence Tomography

      Purpose: To study changes in lamina cribrosa position and prelaminar tissue thickness (PTT) after surgical intraocular pressure (IOP) reduction in glaucoma patients. Methods: Twenty-two patients (mean age, 71.4 years) were imaged with spectral domain optical coherence tomography (SD-OCT, 24 radial B-scans centered on the optic nerve head) before trabeculectomy or tube shunt implantation. Follow-up images were acquired 1 week, 1 month, 3 and 6 months post-surgery. Bruch's membrane opening (BMO), the internal limiting membrane (ILM) and the anterior laminar surface (ALS) were segmented with custom software. Surfaces were fitted to the ILM and ALS with the extracted 3D ...

      Read Full Article
    1-4 of 4
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (4 articles) Dalhousie University
    2. (4 articles) Balwantray C. Chauhan
    3. (4 articles) Marcelo T. Nicolela
    4. (3 articles) Glen P. Sharpe
    5. (1 articles) University of Toronto
    6. (1 articles) Alexandre S. C. Reis
    7. (1 articles) Carl Zeiss Meditec
  3. Popular Articles

  4. Picture Gallery

    Laminar Displacement and Prelaminar Tissue Thickness Change after Glaucoma Surgery Imaged with Optical Coherence Tomography Diagnostic Accuracy of Optical Coherence Tomography and Scanning Laser Tomography for Identifying Glaucoma in Myopic Eyes Asymmetry analysis of macular optical coherence tomography angiography in patients with glaucoma and healthy subjects Peripapillary Retinal Segmentation in Optical Coherence Tomography Angiography Non Exudative AMD Imaged With SS-OCT- Extension High space-bandwidth in quantitative phase imaging using partially spatially coherent optical coherence microscopy and deep neural network Optical coherence tomography assessment of macrophages accumulation in non-ST-segment elevation acute coronary syndromes Early disability in ambulatory patients with multiple sclerosis: optical coherence tomography versus visual evoked potentials, a comparative study Dueling Deep Q-Network for Unsupervised Inter-frame Eye Movement Correction in Optical Coherence Tomography Volumes Atlas of Optical Coherence Tomography for Glaucoma (Textbook) In-vivo analysis of iron-gold composite nanoparticles as potential exogenous contrast agents for Magnetomotive Optical Coherence Tomography (MMOCT) Automatic Classification of Volumetric Optical Coherence Tomography Images via Recurrent Neural Network