1. Articles from Osman O. Ahsen

    1-21 of 21
    1. Tethered capsule en face optical coherence tomography for imaging Barrett’s oesophagus in unsedated patients

      Tethered capsule en face optical coherence tomography for imaging Barrett’s oesophagus in unsedated patients

      Objective Barrett’s oesophagus (BE) screening outside the endoscopy suite can identify patients for surveillance and reduce mortality. Tethered capsule optical coherence tomography (OCT) can volumetrically image oesophageal mucosa in unsedated patients and detect features of BE. We investigated ultrahigh-speed tethered capsule swept-source OCT (SS-OCT), improved device design, developed procedural techniques and measured capsule contact, longitudinal pullback non-uniformity and patient toleration. Design OCT was performed in 16 patients prior to endoscopic surveillance/treatment. Unsedated patients swallowed the capsule with sips of water and the tether was pulled back to image the oesophagus. SS-OCT at 1 000 000 A-scans/s enabled ...

      Read Full Article
    2. Tethered capsule en face optical coherence tomography for imaging Barrett’s esophagus in unsedated patients

      Tethered capsule en face optical coherence tomography for imaging Barrett’s esophagus in unsedated patients

      Objective Detection of Barrett’s esophagus (BE) at points of care outside the endoscopy suite may improve screening access and reduce esophageal adenocarcinoma mortality. Tethered capsule optical coherence tomography (OCT) can volumetrically image esophageal mucosa and detect BE in unsedated patients. We investigated ultrahigh-speed tethered capsule, swept-source OCT (SS-OCT) in unsedated patients, improved device design, developed procedural techniques, measured how capsule contact and longitudinal pullback non-uniformity affect coverage, and assessed patient toleration. Design OCT was performed in 16 patients prior to endoscopic surveillance/treatment. Unsedated patients swallowed the capsule with small sips of water and the esophagus imaged by retracting ...

      Read Full Article
    3. Feature Of The Week 10/08/2018: Clinical Utility of Ultrahigh-Speed Endoscopic Optical Coherence Tomography in Gastroenterology

      Feature Of The Week 10/08/2018: Clinical Utility of Ultrahigh-Speed Endoscopic Optical Coherence Tomography in Gastroenterology

      Barrett’s esophagus (BE) surveillance is limited by biopsy sampling error. Optical coherence tomography (OCT) enables microscopic resolution, high speed, volumetric imaging and is commercially available as volumetric laser endomicroscopy (VLE, NinePoint Medical). Studies investigated cross-sectional OCT dysplasia features, including a diagnostic algorithm (VLE-DA), however, many VLE studies used ex vivo specimens due to challenges in registering biopsy with OCT. We previously demonstrated ultrahigh-speed endoscopic OCT >10x faster than commercial instruments, enabling depth-resolved en face and cross-sectional imaging. This study investigated volumetric en face and cross-sectional OCT for identifying neoplasia. 74 OCT datasets with correlated biopsy/endoscopic mucosal resection histology ...

      Read Full Article
    4. Assessment of Barrett’s esophagus and dysplasia with ultrahigh-speed volumetric en face and cross-sectional optical coherence tomography

      Assessment of Barrett’s esophagus and dysplasia with ultrahigh-speed volumetric en face and cross-sectional optical coherence tomography

      Background  This study aimed to evaluate the use of ultrahigh-speed volumetric en face and cross-sectional optical coherence tomography (OCT) with micromotor catheters for the in vivo assessment of Barrett’s esophagus and dysplasia. Methods  74 OCT datasets with correlated biopsy/endoscopic mucosal resection histology (49 nondysplastic Barrett’s esophagus [NDBE], 25 neoplasia) were obtained from 14 patients with Barrett’s esophagus and a history of dysplasia and 30 with NDBE. The associations between irregular mucosal patterns on en face OCT, absence of mucosal layering, surface signal > subsurface, and > 5 atypical glands on cross-sectional OCT vs. histology and treatment history were ...

      Read Full Article
    5. Cycloid scanning for wide field optical coherence tomography endomicroscopy and angiography in vivo

      Cycloid scanning for wide field optical coherence tomography endomicroscopy and angiography in vivo

      Devices that perform wide field-of-view (FOV) precision optical scanning are important for endoscopic assessment and diagnosis of luminal organ disease such as in gastroenterology. Optical scanning for in vivo endoscopic imaging has traditionally relied on one or more proximal mechanical actuators, limiting scan accuracy and imaging speed. There is a need for rapid and precise two-dimensional (2D) microscanning technologies to enable the translation of benchtop scanning microscopies to in vivo endoscopic imaging. We demonstrate a new cycloid scanner in a tethered capsule for ultrahigh speed, side-viewing optical coherence tomography (OCT) endomicroscopy in vivo . The cycloid capsule incorporates two scanners: a ...

      Read Full Article
    6. Ultrahigh-speed endoscopic optical coherence tomography and angiography enables delineation of lateral margins of endoscopic mucosal resection: a case report

      Ultrahigh-speed endoscopic optical coherence tomography and angiography enables delineation of lateral margins of endoscopic mucosal resection: a case report

      Endoscopic mucosal resection (EMR) is a common technique for resecting dysplastic lesions in Barrett’s esophagus (BE), stomach, and colon, 1 but precise delineation of dysplastic margins before resection and verification of complete removal after resection remain challenging. 2 , 3 Endoscopic optical coherence tomography (OCT) enables three-dimensional visualization of tissue microstructure and is commercially available as Volumetric Laser Endomicroscopy (NinePoint Medical, Bedford, MA, USA). 4 , 5 We recently developed an ultrahigh-speed endoscopic OCT system which operates more than 10 times faster than commercial instruments, generating volumetric images with higher transverse resolution and voxel density. 6 , 7 This allows visualization of ...

      Read Full Article
    7. Endoscopic forward-viewing optical coherence tomography and angiography with MHz swept source

      Endoscopic forward-viewing optical coherence tomography and angiography with MHz swept source

      Endoscopic optical coherence tomography (OCT) instruments are mostly side viewing and rely on at least one proximal scan, thus limiting accuracy of volumetric imaging and en face visualization. Previous forward-viewing OCT devices had limited axial scan speeds. We report a forward-viewing fiber scanning 3D-OCT probe with 900 μm field of view and 5 μm transverse resolution, imaging at 1 MHz axial scan rate in the human gastrointestinal tract. The probe is 3.3 mm diameter and 20 mm rigid length, thus enabling passage through the endoscopic channel. The scanner has 1.8 kHz resonant frequency, and each volumetric acquisition takes ...

      Read Full Article
    8. Assessment of the radiofrequency ablation dynamics of esophageal tissue with optical coherence tomography

      Assessment of the radiofrequency ablation dynamics of esophageal tissue with optical coherence tomography

      Radiofrequency ablation (RFA) is widely used for the eradication of dysplasia and the treatment of early stage esophageal carcinoma in patients with Barrett’s esophagus (BE). However, there are several factors, such as variation of BE epithelium (EP) thickness among individual patients and varying RFA catheter-tissue contact, which may compromise RFA efficacy. We used a high-speed optical coherence tomography (OCT) system to identify and monitor changes in the esophageal tissue architecture from RFA. Two different OCT imaging/RFA application protocols were performed using an ex vivo swine esophagus model: (1) post-RFA volumetric OCT imaging for quantitative analysis of the coagulum ...

      Read Full Article
    9. Endoscopic optical coherence tomography angiography microvascular features associated with dysplasia in Barrett's esophagus: a pilot study (with video)

      Endoscopic optical coherence tomography angiography microvascular features associated with dysplasia in Barrett's esophagus: a pilot study (with video)

      Background and Aims Angiogenesis is associated with neoplastic progression of Barrett’s esophagus (BE). Volumetric optical coherence tomography angiography (OCTA) visualizes subsurface microvasculature without exogenous contrast agents. We investigated the association of OCTA microvascular features with low-grade dysplasia (LGD) and high-grade dysplasia (HGD). Methods Fifty-two patients undergoing BE surveillance or endoscopic eradication therapies for dysplasia were imaged using volumetric OCTA and corresponding histological diagnoses obtained, to yield 97 data sets (non-dysplastic BE (NDBE): N=74; LGD: N=10; HGD: N=13). After evaluating OCTA image quality, 54 datasets (NDBE: N=35; LGD: N=8; HGD: N=11) from 32 patients ...

      Read Full Article
    10. Volumetric Mapping of Barrett’s Esophagus and Dysplasia With en face Optical Coherence Tomography Tethered Capsule

      Volumetric Mapping of Barrett’s Esophagus and Dysplasia With en face Optical Coherence Tomography Tethered Capsule

      To the Editor: Dysplasia in Barrett’s Esophagus (BE) is patchy ( 1 ) and sometimes missed by random biopsies. Optical coherence tomography (OCT) can image large areas of the esophagus; however, slow imaging speeds in earlier studies limited visualization to cross-sections. Cross-sectional OCT detected high-grade dysplasia with sensitivity / specificity of ~80 % ( 2 , 3 ). Tethered OCT capsules were demonstrated for cross-sectional imaging in unsedated screening to detect BE ( 4 , 5 ). Our group recently developed ultrahigh-speed OCT for en face and angiographic imaging, using micromotor probes in patients ( 6 , 7 ) and large field-of-view tethered capsule devices in swine ( 8 ). Narrow-band imaging (NBI) visualizes ...

      Read Full Article
    11. Feature Of The Week 03/08/2015: Endoscopic Optical Coherence Angiography Enables Three Dimensional Visualization of Subsurface Microvasculature

      Feature Of The Week 03/08/2015: Endoscopic Optical Coherence Angiography Enables Three Dimensional Visualization of Subsurface Microvasculature

      Endoscopic imaging technologies such as confocal laser endomicroscopy (CLE) and narrowband imaging (NBI) have been used to investigate vascular changes as hallmarks of early cancer in the GI tract. However, the limited frame rate and field of view make CLE imaging sensitive to motion artifacts, whereas NBI has limited resolution and visualizes only the surface vascular pattern. Endoscopic optical coherence tomography (OCT) enables high speed volumetric imaging of subsurface features at near-microscopic resolution, and can image microvasculature without exogenous contrast agents such as fluorescein, which obliterates the image in areas of bleeding, or after biopsies and resections. OCT has been ...

      Read Full Article
    12. Endoscopic Optical Coherence Angiography Enables Three Dimensional Visualization of Subsurface Microvasculature

      Endoscopic Optical Coherence Angiography Enables Three Dimensional Visualization of Subsurface Microvasculature

      Endoscopic imaging technologies such as confocal laser endomicroscopy1 and narrow band imaging (NBI)2 have been used to investigate vascular changes as hallmarks of early cancer in the gastrointestinal tract. However, the limited frame rate and field of view make confocal laser endomicroscopy imaging sensitive to motion artifacts, whereas NBI has limited resolution and visualizes only the surface vascular pattern. Endoscopic optical coherence tomography (OCT) enables high-speed volumetric imaging of subsurface features at near-microscopic resolution,3, 4 and can image microvasculature without exogenous contrast agents,5 such as fluorescein, which obliterates the image in areas of bleeding, or after ...

      Read Full Article
    13. Ultrahigh speed endoscopic optical coherence tomography for gastroenterology

      Ultrahigh speed endoscopic optical coherence tomography for gastroenterology

      We describe an ultrahigh speed endoscopic swept source optical coherence tomography (OCT) system for clinical gastroenterology using a vertical-cavity surface-emitting laser (VCSEL) and micromotor imaging catheter. The system had a 600 kHz axial scan rate and 8 µm axial resolution in tissue. Imaging was performed with a 3.2 mm diameter imaging catheter at 400 frames per second with a 12 µm spot size. Three-dimensional OCT (3D-OCT) imaging was performed in patients with a cross section of pathologies undergoing upper and lower endoscopy. The use of distally actuated imaging catheters enabled OCT imaging with more flexibility, such as volumetric imaging ...

      Read Full Article
    14. Correction of rotational distortion for catheter-based en face OCT and OCT angiography

      Correction of rotational distortion for catheter-based en face OCT and OCT angiography

      We demonstrate a computationally efficient method for correcting the nonuniform rotational distortion (NURD) in catheter-based imaging systems to improve endoscopic en face optical coherence tomography (OCT) and OCT angiography. The method performs nonrigid registration using fiducial markers on the catheter to correct rotational speed variations. Algorithm performance is investigated with an ultrahigh-speed endoscopic OCT system and micromotor catheter. Scan nonuniformity is quantitatively characterized, and artifacts from rotational speed variations are significantly reduced. Furthermore, we present endoscopic en face OCT and OCT angiography images of human gastrointestinal tract in vivo to demonstrate the image quality improvement using the correction algorithm.

      Read Full Article
    15. Endoscopic Optical Coherence Angiography Enables 3-Dimensional Visualization of Subsurface Microvasculature

      Endoscopic Optical Coherence Angiography Enables 3-Dimensional Visualization of Subsurface Microvasculature

      Endoscopic imaging technologies such as confocal laser endomicroscopy 1 and narrow band imaging (NBI) 2 have been used to investigate vascular changes as hallmarks of early cancer in the gastrointestinal tract. However, the limited frame rate and field of view make confocal laser endomicroscopy imaging sensitive to motion artifacts, whereas NBI has limited resolution and visualizes only the surface vascular pattern. Endoscopic optical coherence tomography (OCT) enables high-speed volumetric imaging of subsurface features at near-microscopic resolution, 3,4 and can image microvasculature without exogenous contrast agents, 5 such as fluorescein, which obliterates the image in areas of bleeding, or after ...

      Read Full Article
    16. Ultrahigh speed endoscopic swept source optical coherence tomography using a VCSEL light source and micromotor catheter

      Ultrahigh speed endoscopic swept source optical coherence tomography using a VCSEL light source and micromotor catheter

      We developed an ultrahigh speed endoscopic swept source optical coherence tomography (OCT) system for clinical gastroenterology using a vertical-cavity surface-emitting laser (VCSEL) and micromotor based imaging catheter, which provided an imaging speed of 600 kHz axial scan rate and 8 μm axial resolution in tissue. The micromotor catheter was 3.2 mm in diameter and could be introduced through the 3.7 mm accessory port of an endoscope. Imaging was performed at 400 frames per second with an 8 μm spot size using a pullback to generate volumetric data over 16 mm with a pixel spacing of 5 μm in ...

      Read Full Article
    17. Compact piezoelectric transducer fiber scanning probe for optical coherence tomography

      Compact piezoelectric transducer fiber scanning probe for optical coherence tomography

      We developed a compact, optical fiber scanning piezoelectric transducer (PZT) probe for endoscopic and minimally invasive optical coherence tomography (OCT). Compared with previous forward-mount fiber designs, we present a reverse-mount design that achieves a shorter rigid length. The fiber was mounted at the proximal end of a quadruple PZT tube and scanned inside the hollow PZT tube to reduce the probe length. The fiber resonant frequency was 338 Hz using a 17-mm-long fiber. A 0.9 mm fiber deflection was achieved with a driving amplitude of 35 V. Using a GRIN lens-based optical design with a 1.3 × magnification, a ...

      Read Full Article
    18. Swept source optical coherence microscopy using a 1310 nm VCSEL light source

      Swept source optical coherence microscopy using a 1310 nm VCSEL light source

      We demonstrate high speed, swept source optical coherence microscopy (OCM) using a MEMS tunable vertical cavity surface-emitting laser (VCSEL) light source. The light source had a sweep rate of 280 kHz, providing a bidirectional axial scan rate of 560 kHz. The sweep bandwidth was 117 nm centered at 1310 nm, corresponding to an axial resolution of 13.1 µm in air, corresponding to 8.1 µm (9.6 µm spectrally shaped) in tissue. Dispersion mismatch from different objectives was compensated numerically, enabling magnification and field of view to be easily changed. OCM images were acquired with transverse resolutions between 0 ...

      Read Full Article
    19. Silencing Of The Drosophila Ortholog Of SOX5 In Heart Leads To Cardiac Dysfunction As Detected By Optical Coherence Tomography

      Silencing Of The Drosophila Ortholog Of SOX5 In Heart Leads To Cardiac Dysfunction As Detected By Optical Coherence Tomography

      The SRY-related HMG-box 5 (SOX5) gene encodes a member of the SOX family of transcription factors. Recently, genome-wide association studies have implicated SOX5 as a candidate gene for susceptibility to four cardiac-related endophenotypes: higher resting heart rate (RHR), the electrocardiographic PR interval, atrial fibrillation (AF) and left ventricular mass (LVM). We have determined that human SOX5 has a highly conserved Drosophila ortholog, Sox102F, and have employed transgenic Drosophila models to quantitatively measure cardiac function in adult flies. For this purpose, we have developed a high-speed and ultrahigh-resolution optical coherence tomography (OCT) imaging system, which enables rapid cross-sectional imaging of the ...

      Read Full Article
    20. Structural markers observed with endoscopic 3-dimensional optical coherence tomography correlating with Barrett's esophagus radiofrequency ablation treatment response (with videos)

      Structural markers observed with endoscopic 3-dimensional optical coherence tomography correlating with Barrett's esophagus radiofrequency ablation treatment response (with videos)

      Background Radiofrequency ablation (RFA) is effective for treating Barrett's esophagus (BE) but often involves multiple endoscopy sessions over several months to achieve complete response. Objective Identify structural markers that correlate with treatment response by using 3-dimensional (3-D) optical coherence tomography (OCT; 3-D OCT). Design Cross-sectional. Setting Single teaching hospital. Patients Thirty-three patients, 32 male and 1 female, with short-segment (<3 cm) BE undergoing RFA treatment. Intervention Patients were treated with focal RFA, and 3-D OCT was performed at the gastroesophageal junction before and immediately after the RFA treatment. Patients were re-examined with standard endoscopy 6 to 8 weeks later ...

      Read Full Article
    21. Comparison of Tissue Architectural Changes between Radiofrequency Ablation and Cryospray Ablation in Barrett’s Esophagus Using Endoscopic Three-Dimensional Optical Coherence Tomography

      Comparison of Tissue Architectural Changes between Radiofrequency Ablation and Cryospray Ablation in Barrett’s Esophagus Using Endoscopic Three-Dimensional Optical Coherence Tomography

      Two main nonsurgical endoscopic approaches for ablating dysplastic and early cancer lesions in the esophagus have gained popularity, namely, radiofrequency ablation (RFA) and cryospray ablation (CSA). We report a uniquely suited endoscopic and near-microscopic imaging modality, three-dimensional (3D) optical coherence tomography (OCT), to assess and compare the esophagus immediately after RFA and CSA. The maximum depths of architectural changes were measured and compared between the two treatment groups. RFA was observed to induce 230~260 

      Read Full Article
    1-21 of 21
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (21 articles) Osman O. Ahsen
    2. (20 articles) Massachusetts Institute of Technology
    3. (20 articles) James G. Fujimoto
    4. (18 articles) Hiroshi Mashimo
    5. (17 articles) Hsiang-Chieh Lee
    6. (16 articles) Benjamin M. Potsaid
    7. (16 articles) Thorlabs
    8. (12 articles) Tsung-Han Tsai
    9. (12 articles) Vijay Jayaraman
    10. (12 articles) Praevium Research
    11. (1 articles) UC Irvine
    12. (1 articles) University of Southern California
    13. (1 articles) The Chinese University of Hong Kong
    14. (1 articles) Qifa Zhou
    15. (1 articles) K. Kirk Shung
    16. (1 articles) Optovue
    17. (1 articles) Heidelberg Engineering
  3. Popular Articles

  4. Picture Gallery

    Comparison of Tissue Architectural Changes between Radiofrequency Ablation and Cryospray Ablation in Barrett’s Esophagus Using Endoscopic Three-Dimensional Optical Coherence Tomography Structural markers observed with endoscopic 3-dimensional optical coherence tomography correlating with Barrett's esophagus radiofrequency ablation treatment response (with videos) Silencing Of The Drosophila Ortholog Of SOX5 In Heart Leads To Cardiac Dysfunction As Detected By Optical Coherence Tomography Swept source optical coherence microscopy using a 1310 nm VCSEL light source Compact piezoelectric transducer fiber scanning probe for optical coherence tomography Ultrahigh speed endoscopic swept source optical coherence tomography using a VCSEL light source and micromotor catheter Correction of rotational distortion for catheter-based en face OCT and OCT angiography Ultrahigh speed endoscopic optical coherence tomography for gastroenterology Feature Of The Week 03/08/2015: Endoscopic Optical Coherence Angiography Enables Three Dimensional Visualization of Subsurface Microvasculature Endoscopic optical coherence tomography angiography microvascular features associated with dysplasia in Barrett's esophagus: a pilot study (with video) Optical imaging techniques could offer non-invasive method to measure swelling within the brain, new study finds Using Optical Coherence Tomography as a Surrogate of Measurements of Intracranial Pressure in Idiopathic Intracranial Hypertension