1. Articles from Giulia Paoletti

    1-7 of 7
    1. Reproducibility of serial optical coherence tomography measurements for lumen area and plaque components in humans (The CLI-VAR [Centro per la Lotta Contro l’Infarto-variability] II study)

      Reproducibility of serial optical coherence tomography measurements for lumen area and plaque components in humans (The CLI-VAR [Centro per la Lotta Contro l’Infarto-variability] II study)

      Frequency-domain optical coherence tomography (FD-OCT) is a promising intracoronary imaging technique to study atherosclerosis. Indeed, its unprecedented spatial resolution allows the assessment of fibrous cap thickness, lipid pool and features of plaque vulnerability. Aim of this study was to determine the reproducibility of the in vivo FD-OCT measurements of lumen area and plaque components in serial studies. Twenty-six patients undergoing FD-OCT assessment of intermediate lesion during coronary angiography were included in this study. FD-OCT pullbacks were acquired twice from the same coronary segment at interval of 5 min without additional intervention and analyzed off-line at an independent imaging core laboratory ...

      Read Full Article
      Mentions: Francesco Prati
    2. Clinical Impact of OCT Findings During PCI: The CLI-OPCI II Study

      Clinical Impact of OCT Findings During PCI: The CLI-OPCI II Study

      Objectives The goal of this study was to assess the clinical impact of optical coherence tomography (OCT) findings during percutaneous coronary intervention (PCI). Background OCT provides unprecedented high-definition visualization of plaque/stent structures during PCI; however, the impact of OCT findings on outcome remains undefined. Methods In the context of the multicenter CLI-OPCI (Centro per la Lotta contro l’Infarto–Optimisation of Percutaneous Coronary Intervention) registry, we retrospectively analyzed patients undergoing end-procedural OCT assessment and compared the findings with clinical outcomes. Results A total of 1,002 lesions (832 patients) were assessed. Appropriate OCT assessment was obtained in 98.2 ...

      Read Full Article
    3. Comparison between intermediate and severe coronary stenoses and clinical outcomes of an OCT-guided PCI strategy

      Comparison between intermediate and severe coronary stenoses and clinical outcomes of an OCT-guided PCI strategy

      Aims: We compared optical coherence tomography (OCT) features of intermediate and severe coronary stenoses in patients with stable angina and acute coronary syndrome (ACS), and tested the clinical impact of an OCT-based strategy for treating intermediate stenoses. Methods: The study enrolled 135 consecutive patients with either ACS or stable angina and a single de-novo coronary stenosis. Patients were divided into two groups: intermediate stenosis defined as quantitative coronary angiography percentage narrowing less than 70%, or presence of angiographic vessel haziness and severe stenosis with percentage narrowing more than 70%. OCT was performed to assess features of plaque vulnerability and to ...

      Read Full Article
      Mentions: Francesco Prati
    4. Reproducibility of the Carpet View system: a novel technical solution for display and off line analysis of OCT images

      Reproducibility of the Carpet View system: a novel technical solution for display and off line analysis of OCT images

      The optical coherence tomography (OCT) evaluation of the stent anatomy requires the inspection of sequential cross section (CS). However stent coils cannot be appreciated in the conventional format as the OCT CS simply display stent struts, that are poorly representative of the stent architecture. The aim of the present study was to validate a new software ( Carpet View ), which unfolds the stented segment, reconstructing it as an open structure and displaying the stent meshwork. 21 patients were studied with frequency domain OCT after the deployment of different stents: seven bio-absorbable scaffolds (Dream), seven bare metal stent (Vision/Multilink8), seven drug ...

      Read Full Article
      Mentions: Francesco Prati
    5. Optical coherence tomography guided in-stent thrombus removal in patients with acute coronary syndromes

      Optical coherence tomography guided in-stent thrombus removal in patients with acute coronary syndromes

      The persistence of thrombus inside stent struts is a frequent event in patients with acute coronary syndromes (ACS) undergoing percutaneous coronary intervention (PCI), and this phenomenon might be associated with an increased risk of stent thrombosis. We sought to quantify by means of optical coherence tomography (OCT) the presence of in-stent thrombus after achievement of an optimal angiographic result in patients with ACS undergoing PCI. In addition, we evaluated the feasibility and safety of an OCT-guided strategy of in-stent thrombus removal. Eighty consecutive patients with ACS undergoing PCI were treated with two different strategies equally divided into two groups: angio-guided ...

      Read Full Article
    6. Reproducibility of Coronary Optical Coherence Tomography for Lumen and Length Measurements in Humans (The CLI-VAR [Centro per la Lotta contro l'Infarto-VARiability] Study)

      Reproducibility of Coronary Optical Coherence Tomography for Lumen and Length Measurements in Humans (The CLI-VAR [Centro per la Lotta contro l'Infarto-VARiability] Study)

      Frequency-domain optical coherence tomography (FD-OCT) is becoming a useful diagnostic tool for coronary imaging for quantitative coronary analysis. Second-generation FD-OCT produces detailed coronary lumen images. However, the reproducibility of coronary measurements using FD-OCT in humans has not been thoroughly explored. Our goal was to determine the intraobserver, interobserver, and interpullback reproducibility of the in vivo FD-OCT measurements of the lumen area and/or lesion length. Twenty-five patients undergoing coronary angioplasty were included. In all subjects, FD-OCT pullbacks (20 mm/s) were acquired twice from the same coronary segment different from the target lesion, at an interval of 5 minutes, with ...

      Read Full Article
    7. Reproducibility of Coronary Optical Coherence Tomography for Lumen and Length Measurements in Humans (The CLI-VAR [Centro per la Lotta contro l'Infarto-VARiability] Study)

      Reproducibility of Coronary Optical Coherence Tomography for Lumen and Length Measurements in Humans (The CLI-VAR [Centro per la Lotta contro l'Infarto-VARiability] Study)

      Frequency-domain optical coherence tomography (FD-OCT) is becoming a useful diagnostic tool for coronary imaging for quantitative coronary analysis. Second-generation FD-OCT produces detailed coronary lumen images. However, the reproducibility of coronary measurements using FD-OCT in humans has not been thoroughly explored. Our goal was to determine the intraobserver, interobserver, and interpullback reproducibility of the in vivo FD-OCT measurements of the lumen area and/or lesion length. Twenty-five patients undergoing coronary angioplasty were included. In all subjects, FD-OCT pullbacks (20 mm/s) were acquired twice from the same coronary segment different from the target lesion, at an interval of 5 minutes, with ...

      Read Full Article
    1-7 of 7
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (7 articles) Francesco Prati
    2. (4 articles) Massachusetts General Hospital
    3. (3 articles) Giuseppe Biondi-Zoccai
    4. (2 articles) Corrado Tamburino
    5. (1 articles) University of Catania
    6. (1 articles) Cardiovascular Research Foundation
    7. (1 articles) European Society of Cardiology
    8. (1 articles) Sapienza University of Rome
    9. (1 articles) Gary S. Mintz
    10. (1 articles) Stanford University
    11. (1 articles) Harvard University
    12. (1 articles) Kawasaki Medical School
    13. (1 articles) University of Washington
    14. (1 articles) Brigham and Women’s Hospital
    15. (1 articles) L V Prasad Eye Institute
    16. (1 articles) Ruikang K. Wang
    17. (1 articles) Sirisha Senthil
    18. (1 articles) Canon Medical Systems
  3. Popular Articles

  4. Picture Gallery

    Reproducibility of Coronary Optical Coherence Tomography for Lumen and Length Measurements in Humans (The CLI-VAR [Centro per la Lotta contro l'Infarto-VARiability] Study) Reproducibility of Coronary Optical Coherence Tomography for Lumen and Length Measurements in Humans (The CLI-VAR [Centro per la Lotta contro l'Infarto-VARiability] Study) Optical coherence tomography guided in-stent thrombus removal in patients with acute coronary syndromes Reproducibility of the Carpet View system: a novel technical solution for display and off line analysis of OCT images Comparison between intermediate and severe coronary stenoses and clinical outcomes of an OCT-guided PCI strategy Clinical Impact of OCT Findings During PCI: The CLI-OPCI II Study Reproducibility of serial optical coherence tomography measurements for lumen area and plaque components in humans (The CLI-VAR [Centro per la Lotta Contro l’Infarto-variability] II study) Image contrast correction method in full-field optical coherence tomography Evaluation of posterior vitreous detachment using ultrasonography and optical coherence tomography Optical coherence tomography angiography characteristics of acute retinal arterial occlusion Computed Tomography–Mediated Registration of Trapeziometacarpal Articular Cartilage Using Intraarticular Optical Coherence Tomography and Cryomicrotome Imaging: A Cadaver Study Successful Treatment of Genital Warts with Ingenol Mebutate Monitored with Optical Coherence Tomography and Reflectance Confocal Microscopy