1. Articles from J. P. Rolland

    1-6 of 6
    1. Phase-resolved Doppler imaging with dual-detection full-range frequency domain optical coherence tomography

      Phase-resolved Doppler imaging with dual-detection full-range frequency domain optical coherence tomography

      We have reported a technique of full-range imaging so-called a Dual-Detection Frequency Domain Optical Coherence Tomography (DD-FD-OCT), in which two spectra, representing real and imaginary components of a complex spectral interference, are simultaneously acquired by two detection channels. In this paper, we will discuss in detail a mirror rejection performance of DD-FD-OCT. Furthermore, we present an implementation of DD-FD-OCT for phase-resolved Doppler imaging. The DD-FD-OCT signal is achieved without manipulation of the phase relation between consecutive axial lines and hence its phase information is almost identical to that acquired by the conventional FD-OCT. As a result, the full-range DD-FD-OCT is ...

      Read Full Article
    2. Full-range spectral domain Doppler optical coherence tomography

      Full-range spectral domain Doppler optical coherence tomography
      Spectral domain optical coherence tomography (SD-OCT) systems achieve higher sensitivities compared to time domain OCT systems. However, one of the main challenges in SD-OCT is the obscuring object structure called "ghost image" or "mirror image" that arises from the Fourier transform of a real function. We have designed and developed a phaseshifting- based full-range SD-OCT system that we refer to as the dual detection full range SD-OCT. The proposed technique simultaneously obtains the quadrature components of a complex spectral interference. Therefore, the technique enables full range imaging without any loss of speed and is intrinsically less sensitive to movements of ...
      Read Full Article
    3. Sub-cellular resolution imaging with Gabor domain optical coherence microscopy

      Sub-cellular resolution imaging with Gabor domain optical coherence microscopy
      Optical Coherence Microscopy (OCM) utilizes a high NA microscope objective in the sample arm to achieve an axially and laterally high resolution OCT image. An increase in NA, however, leads to a dramatically decreased depth of focus (DOF), and hence shortens the imaging depth range so that high lateral resolution is maintained only within a small depth region around the focal plane. One solution to increase the depth of imaging while keeping a high lateral resolution is dynamic-focusing. Utilizing the voltage controlled refocus capability of a liquid lens, we have recently presented a solution for invariant high resolution imaging using ...
      Read Full Article
    4. Gabor domain optical coherence microscopy

      Gabor domain optical coherence microscopy
      Optical Coherence Microscopy (OCM) utilizes a higher NA microscope objective in the sample arm of a low coherence interferometer than in Optical Coherence Tomography (OCT) to achieve axially and laterally high-resolution optical tomographic images. An increase in NA, however, leads to a dramatically decreased depth of focus (DOF), and hence shortens the imaging depth range so that high lateral resolution is maintained only within a small depth region around the focal plane. One solution to increase the depth of imaging while keeping a high lateral resolution is dynamic-focusing. Utilizing the voltage controlled refocus capability of a liquid lens, we have ...
      Read Full Article
    5. Detection of abnormalities in biological tissue using optical coherence tomography

      Detection of abnormalities in biological tissue using optical coherence tomography
      We studied the performance of an OCT imaging modality on the task of detecting an abnormality in biological tissue. Optical propagation in biological samples is dominated by scattering due to fluctuations in refractive index. We used the first order multiple scattering approximation to describe the ... [Proc. SPIE Int. Soc. Opt. Eng. 6849, 68490L (2008)] published Tue Feb 12, 2008.
      Read Full Article
    1-6 of 6
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (6 articles) Jannick P. Rolland
    2. (5 articles) University of Rochester
    3. (5 articles) Kye-Sung Lee
    4. (4 articles) University of Central Florida
    5. (4 articles) Panomsak Meemon
    6. (3 articles) Supraja Murali
    7. (2 articles) Kevin P. Thompson
    8. (2 articles) Optical Research Associates
    9. (1 articles) University of Arizona
    10. (1 articles) University Hospital Zurich
    11. (1 articles) Harvard University
    12. (1 articles) Massachusetts General Hospital
    13. (1 articles) University of Athens
    14. (1 articles) L V Prasad Eye Institute
    15. (1 articles) Leiden University
    16. (1 articles) Massachusetts Institute of Technology
    17. (1 articles) Gijs van Soest
    18. (1 articles) Brett E. Bouma
    19. (1 articles) Evelyn Regar
  3. Popular Articles

  4. Picture Gallery

    Invariant resolution dynamic focus OCM based on liquid crystal lens Detection of abnormalities in biological tissue using optical coherence tomography Full-range spectral domain Doppler optical coherence tomography Gabor domain optical coherence microscopy Sub-cellular resolution imaging with Gabor domain optical coherence microscopy Phase-resolved Doppler imaging with dual-detection full-range frequency domain optical coherence tomography Sequential imaging of a case of choroidal osteoma using swept-source OCT and optical coherence tomography angiography: A 4-year follow-up study Optical coherence tomography angiography–based analysis of intrinsic vasculature in juxtapapillary melanoma after ruthenium-106 plaque brachytherapy Understanding the structural changes following photodynamic and transpupillary thermotherapy for choroidal hemangioma using optical coherence tomography and optical coherence tomography angiography Swept-source optical coherence tomography features of regressed macular retinoblastoma Intravascular Polarimetry in Patients With Coronary Artery Disease AI More than Human in Healthcare