1. Articles from Peter Fitzgerald

    1-3 of 3
    1. Comparative analysis method of permanent metallic stents (XIENCE) and bioresorbable poly-L-lactic (PLLA) scaffolds (Absorb) on optical coherence tomography at baseline and follow-up

      Comparative analysis method of permanent metallic stents (XIENCE) and bioresorbable poly-L-lactic (PLLA) scaffolds (Absorb) on optical coherence tomography at baseline and follow-up

      Aims: Fully bioresorbable Absorb poly-L-lactic-acid (PLLA) scaffolds (Abbott Vascular, Santa Clara, CA, USA) are a novel approach for the treatment of coronary narrowing. Due to the translucency of the material (PLLA), the optical coherence tomography (OCT) measurement methods used in the ABSORB trials were unique but not applicable for permanent metallic stents. When the Absorb scaffold and metallic stents are compared in the context of randomised trials, it is challenging to compare the two devices using the conventional methods. The primary purpose of this report is to explain the biases in conventional methodologies applied for metallic stents and for PLLA ...

      Read Full Article
    2. First-in-Human Evaluation of a Bioabsorbable Polymer–Coated Sirolimus-Eluting Stent: Imaging and Clinical Results of the DESSOLVE I Trial (DES With Sirolimus and a Bioabsorbable Polymer for the Treatment of Patients With De Novo Lesion in the Native Coro

      First-in-Human Evaluation of a Bioabsorbable Polymer–Coated Sirolimus-Eluting Stent: Imaging and Clinical Results of the DESSOLVE I Trial (DES With Sirolimus and a Bioabsorbable Polymer for the Treatment of Patients With De Novo Lesion in the Native Coro

      Objectives This first-in-human multicenter study sought to examine prospectively the safety and efficacy of a new, cobalt chromium thin-strut, coronary absorbable polymer–coated, sirolimus-eluting stent. Background Bioabsorbable polymers on drug-eluting stents may lower the long-term risks of inflammation, delayed healing, and adverse events. Methods We enrolled patients with symptomatic coronary artery disease with stable or unstable angina pectoris and >50% diameter stenosis, amenable to coverage with a ≤23-mm long stent in a vessel 2.5 to 3.5 mm in diameter. All patients received dual antiplatelet therapy after implantation. Patients, in groups of 10, underwent repeat angiography, intravascular ultrasound, and ...

      Read Full Article
    3. Consensus Standards for Acquisition, Measurement, and Reporting of Intravascular Optical Coherence Tomography Studies: A Report From the International Working Group for Intravascular Optical Coherence Tomography Standardization and Validation

      Consensus Standards for Acquisition, Measurement, and Reporting of Intravascular Optical Coherence Tomography Studies: A Report From the International Working Group for Intravascular Optical Coherence Tomography Standardization and Validation

      Objectives: The purpose of this document is to make the output of the International Working Group for Intravascular Optical Coherence Tomography (IWG-IVOCT) Standardization and Validation available to medical and scientific communities, through a peer-reviewed publication, in the interest of improving the diagnosis and treatment of patients with atherosclerosis, including coronary artery disease.Background: Intravascular optical coherence tomography (IVOCT) is a catheter-based modality that acquires images at a resolution of 10 μm, enabling visualization of blood vessel wall microstructure in vivo at an unprecedented level of detail. IVOCT devices are now commercially available worldwide, there is an active user base, and ...

      Read Full Article
    1-3 of 3
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (3 articles) Case Western Reserve University
    2. (3 articles) Peter J. Fitzgerald
    3. (2 articles) Academic Medical Center at the University of Amsterdam
    4. (2 articles) Erasmus University
    5. (2 articles) Leiden University
    6. (2 articles) Maria D. Radu
    7. (2 articles) Marco A. Costa
    8. (2 articles) Patrick W. Serruys
    9. (2 articles) Evelyn Regar
    10. (2 articles) Hiram G. Bezerra
  3. Popular Articles

  4. Picture Gallery

    Consensus Standards for Acquisition, Measurement, and Reporting of Intravascular Optical Coherence Tomography Studies: A Report From the International Working Group for Intravascular Optical Coherence Tomography Standardization and Validation First-in-Human Evaluation of a Bioabsorbable Polymer–Coated Sirolimus-Eluting Stent: Imaging and Clinical Results of the DESSOLVE I Trial (DES With Sirolimus and a Bioabsorbable Polymer for the Treatment of Patients With De Novo Lesion in the Native Coro Comparative analysis method of permanent metallic stents (XIENCE) and bioresorbable poly-L-lactic (PLLA) scaffolds (Absorb) on optical coherence tomography at baseline and follow-up Multimodality Imaging Approach for Combined Central Retinal Vein and Artery Occlusion: The Role of Optical Coherence Tomography Angiography Postdoctoral Position Opening in High Resolution OCT at Nanyang Technological University Correlation analysis of physical fitness and retinal microvasculature by OCT angiography in healthy adults Clinical Practice Settings vs Clinical Trials Is Artificial Intelligence the Answer? Prevalence of dengue-related fundus and macular optical coherence tomography findings among inpatients in a regional referral hospital The lesson of ‘the butler didn’t do it!’. Role of optical coherence tomography for going beyond appearance Identification of multi-dimensional thread geometry using depth-resolved swept-source optical coherence tomography for assessment of dental implant fabrication Assessing the Use of Incorrectly Scaled Optical Coherence Tomography Angiography Images in Peer-Reviewed Studies High-Resolution Optical Coherence Tomography (OCT) for Skin Imaging (Book Chapter)