1. Articles from Yasutsugu Shiono

    1-24 of 32 1 2 »
    1. Optical coherence tomography detection of vulnerable plaques at high risk of developing acute coronary syndrome

      Optical coherence tomography detection of vulnerable plaques at high risk of developing acute coronary syndrome

      Aims: The ability of optical coherence tomography (OCT) to detect plaques at high risk of developing acute coronary syndrome (ACS) remains unclear. The aim of this study was to evaluate the association between non-culprit plaques characterized as both lipid-rich plaque (LRP) and thin-cap fibroatheroma (TCFA) by OCT and the risk of subsequent ACS events at the lesion level. Methods and results: In 1378 patients who underwent OCT, 3533 non-culprit plaques were analysed for the presence of LRP (maximum lipid arc > 180°) and TCFA (minimum fibrous cap thickness < 65 μm). The median follow-up period was 6 years [interquartile range (IQR): 5-9 ...

      Read Full Article
    2. Impact of Optical Coherence Tomography Imaging on Decision-Making During Percutaneous Coronary Intervention in Patients Presented With Acute Coronary Syndromes

      Impact of Optical Coherence Tomography Imaging on Decision-Making During Percutaneous Coronary Intervention in Patients Presented With Acute Coronary Syndromes

      Background: Optical coherence tomography (OCT) provides valuable information to guide percutaneous coronary intervention (PCI) in acute coronary syndrome (ACS) regarding lesion preparation, stent sizing, and optimization. The aim of the present study was to compare lumen expansion of stent-treated lesions immediately after the procedure for ACS between OCT-guided PCI and angiography-guided PCI.Methods and Results:This study investigated stent-treated lesions immediately after PCI for ACS by using quantitative coronary angiography in 390 patients; 260 patients with OCT-guided PCI and 130 patients with angiography-guided PCI. Before stenting, the frequency of pre-dilatation and thrombus aspiration were not different between the OCT-guided and ...

      Read Full Article
    3. Prevalence, Features, and Prognosis of Artery-to-Artery Embolic ST-Segment-Elevation Myocardial Infarction: An Optical Coherence Tomography Study

      Prevalence, Features, and Prognosis of Artery-to-Artery Embolic ST-Segment-Elevation Myocardial Infarction: An Optical Coherence Tomography Study

      Background The major underlying mechanisms contributing to acute coronary syndrome are plaque rupture, plaque erosion, and calcified nodule. Artery-to-artery embolic myocardial infarction (AAEMI) was defined as ST-segment-elevation myocardial infarction caused by migrating thrombus formed at the proximal ruptured plaque. The aim of this study was to investigate the prevalence and clinical features of AAEMI by using optical coherence tomography. Methods and Results This study retrospectively enrolled 297 patients with ST-segment-elevation myocardial infarction who underwent optical coherence tomography before percutaneous coronary intervention. Patients were divided into 4 groups consisting of plaque rupture, plaque erosion, calcified nodule, and AAEMI according to optical ...

      Read Full Article
    4. NIRS-IVUS for Differentiating Coronary Plaque Rupture, Erosion and Calcified Nodule in Acute Myocardial Infarction

      NIRS-IVUS for Differentiating Coronary Plaque Rupture, Erosion and Calcified Nodule in Acute Myocardial Infarction

      Objectives This study sought to investigate the ability of combined near-infrared spectroscopy and intravascular ultrasound (NIRS-IVUS) to differentiate plaque rupture (PR), plaque erosion (PE), or calcified nodule (CN) in acute myocardial infarction (AMI). Background Most acute coronary syndromes occur from coronary thrombosis based on PR, PE, or CN. In vivo differentiation among PR, PE, and CN is a major challenge for intravascular imaging. Methods The study enrolled 244 patients with AMI who had a de novo culprit lesion in a native coronary artery. The culprit lesions were assessed by both NIRS-IVUS and optical coherence tomography (OCT). Maximum lipid core burden ...

      Read Full Article
    5. Comparison of Optical Flow Ratio and Fractional Flow Ratio in Stent-Treated Arteries Immediately After Percutaneous Coronary Intervention

      Comparison of Optical Flow Ratio and Fractional Flow Ratio in Stent-Treated Arteries Immediately After Percutaneous Coronary Intervention

      Background: Optical flow ratio (OFR) is a recently developed method for functional assessment of coronary artery disease based on computational fluid dynamics of vascular anatomical data from intravascular optical coherence tomography (OCT). The purpose of this study was to investigate the relationship between OFR and fractional flow reserve (FFR) in stent-treated arteries immediately after percutaneous coronary intervention (PCI). Methods and Results: The OFR and FFR were measured in 103 coronary arteries immediately after successful PCI with a stent. An increase in the OFR and FFR values within the stent was defined as in-stent ∆OFR and ∆FFR, respectively. The values of ...

      Read Full Article
    6. Optical Coherence Tomography Comparison of Percutaneous Coronary Intervention Among Plaque Rupture, Erosion, and Calcified Nodule in Acute Myocardial Infarction

      Optical Coherence Tomography Comparison of Percutaneous Coronary Intervention Among Plaque Rupture, Erosion, and Calcified Nodule in Acute Myocardial Infarction

      Background: Acute myocardial infarction (AMI) is caused by coronary plaque rupture (PR), plaque erosion (PE), or calcified nodule (CN). We used optical coherence tomography (OCT) to compare stent expansion immediately after primary percutaneous coronary intervention (PCI) in patients with AMI caused by PR, PE, or CN. Methods and Results: In all, 288 AMI patients were assessed by OCT before and immediately after PCI, performed with OCT guidance according to OPINION criteria for stent sizing and optimization. The frequency of OCT-identified PR (OCT-PR), OCT-PE, and OCT-CN was 172 (60%), 82 (28%), and 34 (12%), respectively. Minimum stent area was smallest in ...

      Read Full Article
    7. Intracoronary pressure increase due to contrast injection for optical coherence tomography imaging

      Intracoronary pressure increase due to contrast injection for optical coherence tomography imaging

      Background Optical coherence tomography (OCT) requires intracoronary injection of contrast media to remove blood from the field of view during image acquisition. Contrast injection may cause a temporal increase in intracoronary pressure. The aim of this study was to compare the intracoronary pressure during contrast injection between OCT and coronary angiography . Methods We measured intracoronary pressure by using a pressure guidewire during contrast injection for OCT and angiography in 30 coronary arteries (mean fractional flow reserve = 0.90 ± 0.03). Contrast media was injected into coronary artery through the guiding catheter by using a mechanical injector pump. Results Intracoronary pressure ...

      Read Full Article
    8. Imaging assessment and accuracy in coronary artery autopsy: comparison of frequency-domain optical coherence tomography with intravascular ultrasound and histology

      Imaging assessment and accuracy in coronary artery autopsy: comparison of frequency-domain optical coherence tomography with intravascular ultrasound and histology

      ptical coherence tomography (OCT) is a coronary artery imaging technique with high resolution. Second-generation frequency-domain OCT (FD-OCT) technology allows safer and faster clinical application compared with first-generation time-domain OCT (TD-OCT). Only limited validation studies compare FD-OCT with other modes of analysis: histology, which is the current gold standard, and intravascular ultrasound (IVUS). This study therefore aims to demonstrate the accuracy of FD-OCT images compared with IVUS and histology. FD-OCT and IVUS images were acquired from 203 segments from 31 coronary arteries obtained at autopsy from 20 cadavers. Of these, 30 randomly-selected pairs were used to create three classifications of plaque ...

      Read Full Article
    9. Stabilization of High Risk Coronary Plaque on Optical Coherence Tomography and Near-Infrared Spectroscopy by Intensive Lipid-Lowering Therapy With Proprotein Convertase Subtilisin/Kexin Type 9 (PCSK9) Inhibitor

      Stabilization of High Risk Coronary Plaque on Optical Coherence Tomography and Near-Infrared Spectroscopy by Intensive Lipid-Lowering Therapy With Proprotein Convertase Subtilisin/Kexin Type 9 (PCSK9) Inhibitor

      A 70-year-old woman with hypertension and dyslipidemia underwent drug-eluting stent implantation in the mid-left anterior descending artery (LAD) due to acute coronary syndrome (ACS). Optical coherence tomography (OCT) during the index procedure showed lipid-rich plaque in non-culprit lesions of the proximal LAD and mid-right coronary artery (Figure B,E). Near-infrared spectroscopy-intravascular ultrasound (NIRS-IVUS) showed plaque with high lipid burden in both sites (Figure C,F). Intensive lipid-lowering therapy with combined strong statin and proprotein convertase subtilisin/kexin type 9 (PCSK9) inhibitor was started after the index procedure. Scheduled 10-month follow-up OCT and NIRS-IVUS showed increase in minimum fibrous cap thickness ...

      Read Full Article
    10. In vivo optical coherence tomography imaging and histopathology of healed coronary plaques

      In vivo optical coherence tomography imaging and histopathology of healed coronary plaques

      Background and aims The aims of this study were to assess agreement between optical coherence tomography (OCT) and histopathology for healed coronary plaques (HCPs) in human coronary arteries ex vivo , and to evaluate the prevalence and characteristics of HCPs in vivo . Methods Ex vivo OCT images were co-registered with histopathology in 144 cross-sections with ≥50% stenosis. Of these, 30 randomly selected pairs were employed to define morphological features of OCT for HCPs (OCT-derived HCPs); the remaining 114 pairs were used to evaluate the accuracy of OCT in detecting histologically-defined HCPs. In a clinical study, 60 target lesions from 60 patients ...

      Read Full Article
    11. Effect of Early Pitavastatin Therapy on Coronary Fibrous-Cap Thickness Assessed by Optical Coherence Tomography in Patients With Acute Coronary Syndrome : The ESCORT Study

      Effect of Early Pitavastatin Therapy on Coronary Fibrous-Cap Thickness Assessed by Optical Coherence Tomography in Patients With Acute Coronary Syndrome : The ESCORT Study

      Objectives The aim of the present study was to assess the effect of early statin therapy on fibrous-cap thickness in coronary plaques of patients with acute coronary syndrome (ACS) by using optical coherence tomography. Background Statins can contribute to the stabilization of coronary plaques. Methods This is a prospective, randomized, active-controlled, single-center study. Patients with ACS and untreated dyslipidemia were enrolled and randomly allocated (ratio 1:1) to either the early statin group (received pitavastatin 4 mg/day from baseline) or the late statin group (received pitavastatin 4 mg/day from 3 weeks after the baseline). Optical coherence tomography was ...

      Read Full Article
    12. Optical Coherence Tomography Predictors for Edge Restenosis After Everolimus-Eluting Stent Implantation

      Optical Coherence Tomography Predictors for Edge Restenosis After Everolimus-Eluting Stent Implantation

      Background— Stent edge restenosis (SER) remains a potential limitation of drug-eluting stents. The aim of this study was to determine optical coherence tomography (OCT) predictors for angiographic late SER after everolimus-eluting stent implantation. Methods and Results— We retrospectively analyzed 319 patients who underwent OCT immediately after everolimus-eluting stent implantation and scheduled 9- to 12-month follow-up angiography. The binary angiographic SER rate was 10% (32/319) in the patients, 8.4% (32/382) in lesions, and 4.4% (33/744) in stent edge segments. In the stent edge segments at post stenting, OCT-derived lipidic plaque (61% versus 20%; P <0.001 ...

      Read Full Article
    13. Reduction of in-stent thrombus immediately after percutaneous coronary intervention by pretreatment with prasugrel compared with clopidogrel: An optical coherence tomography study

      Reduction of in-stent thrombus immediately after percutaneous coronary intervention by pretreatment with prasugrel compared with clopidogrel: An optical coherence tomography study

      Background Prasugrel is a new-generation thienopyridine antiplatelet agent that provides more consistent and prompt platelet inhibition than clopidogrel. The aim of this study was to compare in-stent thrombus inhibition effect of pretreatment with prasugrel and clopidogrel by using optical coherence tomography (OCT) immediately after percutaneous coronary intervention (PCI) for acute coronary syndrome (ACS). Methods We performed OCT immediately after PCI in 108 ACS patients pretreated with either prasugrel ( n = 51) or clopidogrel ( n = 57). OCT detected thrombus/plaque protrusion in all stented segments. Results Although stent volume (190.4 ± 119.1 mm 3 vs. 189.4 ± 95.8 mm 3 ...

      Read Full Article
    14. Optical coherence tomography assessment of efficacy of thrombus aspiration in patients undergoing a primary percutaneous coronary intervention for acute ST-elevation myocardial infarction

      Optical coherence tomography assessment of efficacy of thrombus aspiration in patients undergoing a primary percutaneous coronary intervention for acute ST-elevation myocardial infarction

      Objective: We used optical coherence tomography (OCT) to assess the impact of thrombus aspiration before angioplasty on poststenting tissue protrusions in patients undergoing a primary percutaneous coronary intervention (PCI) for ST-segment elevation myocardial infarction (STEMI). Methods and results: A total of 188 patients with STEMI who underwent thrombus-aspiration PCI ( n =113) or standard PCI ( n =75) were examined in this study. OCT was performed immediately after primary PCI to assess lesion morphology in the stented segment. The minimum stent area was similar between the thrombus-aspiration PCI group and the standard PCI group [7.4 interquartile range (IQR): 5.8–9 ...

      Read Full Article
    15. Optical coherence tomography assessment of efficacy of thrombus aspiration in patients undergoing a primary percutaneous coronary intervention for acute ST-elevation myocardial infarction

      Optical coherence tomography assessment of efficacy of thrombus aspiration in patients undergoing a primary percutaneous coronary intervention for acute ST-elevation myocardial infarction

      Objective: We used optical coherence tomography (OCT) to assess the impact of thrombus aspiration before angioplasty on poststenting tissue protrusions in patients undergoing a primary percutaneous coronary intervention (PCI) for ST-segment elevation myocardial infarction (STEMI). Methods and results: A total of 188 patients with STEMI who underwent thrombus-aspiration PCI ( n =113) or standard PCI ( n =75) were examined in this study. OCT was performed immediately after primary PCI to assess lesion morphology in the stented segment. The minimum stent area was similar between the thrombus-aspiration PCI group and the standard PCI group [7.4 interquartile range (IQR): 5.8–9 ...

      Read Full Article
    16. Optical coherence tomography assessment of efficacy of thrombus aspiration in patients undergoing a primary percutaneous coronary intervention for acute ST-elevation myocardial infarction

      Optical coherence tomography assessment of efficacy of thrombus aspiration in patients undergoing a primary percutaneous coronary intervention for acute ST-elevation myocardial infarction

      Objective: We used optical coherence tomography (OCT) to assess the impact of thrombus aspiration before angioplasty on poststenting tissue protrusions in patients undergoing a primary percutaneous coronary intervention (PCI) for ST-segment elevation myocardial infarction (STEMI). Methods and results: A total of 188 patients with STEMI who underwent thrombus-aspiration PCI (n=113) or standard PCI (n=75) were examined in this study. OCT was performed immediately after primary PCI to assess lesion morphology in the stented segment. The minimum stent area was similar between the thrombus-aspiration PCI group and the standard PCI group [7.4 interquartile range (IQR): 5.8-9.4 ...

      Read Full Article
    17. Vasa Vasorum Restructuring in Human Atherosclerotic Plaque Vulnerability

      Vasa Vasorum Restructuring in Human Atherosclerotic Plaque Vulnerability

      Background Previous studies have suggested that vasa vasorum (VV) is associated with plaque progression and vulnerability. Objectives The aim of this study was to investigate the relationship between coronary neovascularization structures and plaque characteristics. Methods We included 53 patients who underwent optical coherence tomography to observe the proximal left anterior descending coronary artery. Patients were classified into 5 groups according to lesion characteristics: normal; fibrous plaque (FP); fibroatheroma (FA); plaque rupture (PR); and fibrocalcific plaque (FC). We defined signal-poor tubuloluminal structures recognized in cross-sectional and longitudinal profiles located in adventitial layer as VV, and within plaque as intraplaque neovessels. Two ...

      Read Full Article
    18. Successful Stenting With Optical Frequency Domain Imaging Guidance For Spontaneous Coronary Artery Dissection

      Successful Stenting With Optical Frequency Domain Imaging Guidance For Spontaneous Coronary Artery Dissection

      A 51-year-old woman was urgently admitted because of chest pain. Emergent coronary angiography revealed diffuse stenosis from the proximal to distal portion of the right coronary artery (RCA) with Thrombolysis In Myocardial Infarction (TIMI) flow grade 2 (Figure 1 ). No stenosis was seen in the left coronary artery. Intravascular ultrasound (IVUS) images revealed an intracoronary hematoma from the posterior descending artery (PDA) to the ostium of the RCA, but could not demonstrate the entry point of the hematoma (Figure 1 ). Optical frequency domain imaging (OFDI; Terumo, Tokyo, Japan) images clearly demonstrated, not only intracoronary hematoma from the PDA to the ...

      Read Full Article
    19. Feasibility of Optical Coronary Tomography in Quantitative Measurement of Coronary Arteries With Lipid-Rich Plaque

      Feasibility of Optical Coronary Tomography in Quantitative Measurement of Coronary Arteries With Lipid-Rich Plaque

      Background: The aim of the present study was to evaluate the feasibility of optical coherence tomography (OCT) for measurement of vessel area in coronary arteries with lipid-rich plaque as compared with intravascular ultrasound (IVUS). Methods and Results: We investigated 80 coronary artery segments with lipid-rich plaque on OCT and non-attenuated plaque on IVUS. According to the lipid arc on OCT, the plaques were classified into 4 groups: group 1, lipid arc ≤90°; group 2, 90°<lipid arc≤180°; group 3, 180°<lipid arc≤270°; group 4, lipid arc >270°. Vessel circular arcs that could not be identified due to OCT ...

      Read Full Article
    20. Comparison of vascular response between everolimus-eluting stent and bare metal stent implantation in ST-segment elevation myocardial infarction assessed by optical coherence tomography

      Comparison of vascular response between everolimus-eluting stent and bare metal stent implantation in ST-segment elevation myocardial infarction assessed by optical coherence tomography

      Aims The long-term safety of second-generation everolimus-eluting stents (EESs) in ST-segment elevation myocardial infarction (STEMI) remains unclear. The aim of this study was to evaluate the late vascular response after stent implantation in STEMI between EES and bare-metal stent (BMS) by using optical coherence tomography (OCT). Methods and results A prospective OCT examination was performed in 102 patients at 10 months after stent implantation for treatment of STEMI. A total of 1253 frames with 12 772 struts in 61 EESs and 776 frames with 8594 struts in 41 BMSs were analysed. There were no significant differences in the percentage of ...

      Read Full Article
    21. Effect of Atorvastatin Therapy on Fibrous Cap Thickness in Coronary Atherosclerotic Plaque as Assessed by Optical Coherence Tomography The EASY-FIT Study

      Effect of Atorvastatin Therapy on Fibrous Cap Thickness in Coronary Atherosclerotic Plaque as Assessed by Optical Coherence Tomography The EASY-FIT Study

      Background The detailed mechanism of plaque stabilization by statin therapy is not fully understood. Objectives The aim of this study was to assess the effect of lipid-lowering therapy with 20 mg/day of atorvastatin versus 5 mg/day of atorvastatin on fibrous cap thickness in coronary atherosclerotic plaques by using optical coherence tomography (OCT). Methods Seventy patients with unstable angina pectoris and untreated dyslipidemia were randomized to either 20 mg/day or 5 mg/day of atorvastatin therapy. OCT was performed to assess intermediate nonculprit lesions at baseline and 12-month follow-up. Results Serum low-density lipoprotein cholesterol level was significantly lower ...

      Read Full Article
    22. Impact of Eicosapentaenoic Acid Treatment on the Fibrous Cap Thickness in Patients with Coronary Atherosclerotic Plaque: An Optical Coherence Tomography Study

      Impact of Eicosapentaenoic Acid Treatment on the Fibrous Cap Thickness in Patients with Coronary Atherosclerotic Plaque: An Optical Coherence Tomography Study

      Aim : Previous clinical trials have demonstrated the effectiveness of eicosapentaenoic acid (EPA) in preventing cardiovascular events. The aim of the present study was to investigate the effects of EPA treatment on the accumulation of coronary atherosclerotic plaque using optical coherence tomography (OCT). Methods : A total of 46 acute coronary syndrome (ACS) patients without dyslipidemia were divided into two groups: those who received 1,800 mg/day of EPA ( n =15) or the control group ( n =31). Serial OCT examinations were performed at baseline and after eight months of follow-up. The target for the OCT analysis was non-culprit plaque with a ...

      Read Full Article
    1-24 of 32 1 2 »
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (32 articles) Takashi Kubo
    2. (31 articles) Wakayama Medical University
    3. (31 articles) Takashi Akasaka
    4. (30 articles) Yasushi Ino
    5. (26 articles) Atsushi Tanaka
    6. (22 articles) Yoshiki Matsuo
    7. (18 articles) Hironori Kitabata
    8. (15 articles) Takashi Tanimoto
    9. (10 articles) Toshio Imanishi
    10. (10 articles) Yuichi Ozaki
    11. (1 articles) Cardiovascular Research Foundation
    12. (1 articles) University of Tsukuba
    13. (1 articles) Wakayama Medical University
    14. (1 articles) Georgetown University
    15. (1 articles) Takashi Tanimoto
    16. (1 articles) Gary S. Mintz
    17. (1 articles) Atsushi Tanaka
    18. (1 articles) Takashi Akasaka
    19. (1 articles) Hector M. Garcia-Garcia
    20. (1 articles) Takashi Kubo
  3. Popular Articles

  4. Picture Gallery

    Optical Coherence Tomography Analysis of Clinical and Subclinical Optical Coherence Tomography-Derived Anatomical Criteria for Functionally Significant Coronary Stenosis Assessed by Fractional Flow Reserve Difference in neointimal appearance between early and late restenosis after sirolimus-eluting stent implantation assessed by optical coherence tomography Inter-Scan Reproducibility of Geometric Coronary Artery Measurements Using Frequency-Domain Optical Coherence Tomography Comparison of longitudinal geometric measurement in human coronary arteries between frequency-domain optical coherence tomography and intravascular ultrasound Association between P-selectin Glycoprotein Ligand-1 and Pathogenesis in Acute Coronary Syndrome Assessed by Optical Coherence Tomography Difference of Ruptured Plaque Morphology between Asymptomatic Coronary Artery Disease and Non-ST Elevation Acute Coronary Syndrome Patients: an Optical Coherence Tomography Study Impact of Eicosapentaenoic Acid Treatment on the Fibrous Cap Thickness in Patients with Coronary Atherosclerotic Plaque: An Optical Coherence Tomography Study Successful Stenting With Optical Frequency Domain Imaging Guidance For Spontaneous Coronary Artery Dissection Optical coherence tomography assessment of efficacy of thrombus aspiration in patients undergoing a primary percutaneous coronary intervention for acute ST-elevation myocardial infarction Deep learning differentiates between healthy and diabetic mouse ears from optical coherence tomography angiography images Spectral-Domain Optical Coherence Tomography For Evaluating Palisades of Vogt in Ocular Surface Disorders With Limbal Involvement