1. Articles from Tien-Yin Wong

    1-5 of 5
    1. Detailed Phenotyping and Characterization of Choroidal Morphological and Vascular Features in Young Men with High Myopia Using Spectral-Domain Optical Coherence Tomography

      Detailed Phenotyping and Characterization of Choroidal Morphological and Vascular Features in Young Men with High Myopia Using Spectral-Domain Optical Coherence Tomography

      Purpose To describe detailed morphological and vascular features of the choroid in eyes with high myopia. Design Cross-sectional study. Methods 515 eyes of young men (mean age 21.59±1.15) years) with high myopia (defined as -6.0 D or worse, mean spherical equivalent -8.66±2.00 D) and 88 controls with emmetropia in both eyes underwent choroidal imaging using spectral domain optical coherence tomography with enhanced depth imaging (EDI-OCT). Raw OCT images were loaded on a custom-written application on MATLAB that enabled delineation for detailed morphological and vascular analyses, including the distance of thickest point from the ...

      Read Full Article
    2. Relationship of ocular and systemic factors to the visibility of choroidal–scleral interface using spectral domain optical coherence tomography

      Relationship of ocular and systemic factors to the visibility of choroidal–scleral interface using spectral domain optical coherence tomography

      Purpose To assess the visibility of the choroidal–scleral interface (CSI) from spectral domain optical coherence tomography (SD-OCT) and evaluate the ocular and systemic factors influencing the visibility of CSI in healthy eyes from population-based Malay sample. Methods Participants were consecutively recruited from the population-based Singapore Malay Eye Study-2 (SiMES-2). SD-OCT images were obtained by Spectralis OCT with enhanced depth imaging (EDI) mode. Visibility of CSI was assessed by a grading system ranging from 0 to 2 scores. The reliability of choroidal thickness measurement in different grades of CSI visibility was assessed using intraclass correlation coefficient. Ordinal regression analyses were ...

      Read Full Article
    3. A Simplified Method to Measure Choroidal Thickness Using Adaptive Compensation in Enhanced Depth Imaging Optical Coherence Tomography

      A Simplified Method to Measure Choroidal Thickness Using Adaptive Compensation in Enhanced Depth Imaging Optical Coherence Tomography

      Purpose To evaluate a simplified method to measure choroidal thickness (CT) using commercially available enhanced depth imaging (EDI) spectral domain optical coherence tomography (SD-OCT). Methods We measured CT in 31 subjects without ocular diseases using Spectralis EDI SD-OCT. The choroid-scleral interface of the acquired images was first enhanced using a post-processing compensation algorithm. The enhanced images were then analysed using Photoshop. Two graders independently graded the images to assess inter-grader reliability. One grader re-graded the images after 2 weeks to determine intra-grader reliability. Statistical analysis was performed using intra-class correlation coefficient (ICC) and Bland-Altman plot analyses. Results Using adaptive compensation ...

      Read Full Article
    4. Association of Narrow Angles With Anterior Chamber Area and Volume Measured With Anterior-Segment Optical Coherence Tomography]

      Association of Narrow Angles With Anterior Chamber Area and Volume Measured With Anterior-Segment Optical Coherence Tomography]
      Objectives To describe the measurement of anterior chamber area and anterior chamber volume by anterior-segment optical coherence tomography and to investigate the association of these parameters with the presence of narrow angles. Methods This was a cross-sectional study of subjects aged at least 50 years without ophthalmic symptoms recruited from a community clinic. All participants underwent standardized ocular examination and anterior-segment optical coherence tomography. Customized software was used to measure anterior chamber area (cross-sectional area bounded by the corneal endothelium, anterior surface of iris, and lens within the pupil) and anterior chamber volume (calculated by rotating the anterior chamber area ...
      Read Full Article
    5. Screening for Narrow Angles in the Singapore Population: Evaluation of New Noncontact Screening Methods

      Purpose: To assess the screening effectiveness of 3 new noncontact devices, the scanning peripheral anterior chamber depth analyzer (SPAC) (Takagi, Nagano, Japan), which measures peripheral anterior chamber depth (ACD); IOLMaster (Carl Zeiss Meditec, Jena, Germany), which measures central ACD; and Visante anterior segment optical coherence tomography (AS-OCT) (Visante, Carl Zeiss Meditec, Dublin, CA), which images the angles, and to compare these instruments with gonioscopy in identifying people with narrow angles (NAs).Design: Cross-sectional, observational, community-based study.Participants: Phakic subjects aged ≥50 years without ophthalmic symptoms who were recruited from a community polyclinic in Singapore.Methods: All subjects underwent examination with ...

      Read Full Article
    1-5 of 5
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (4 articles) Singapore Eye Research Institute
    2. (4 articles) National University of Singapore
    3. (2 articles) Johns Hopkins University
    4. (2 articles) Boston University
    5. (2 articles) Massachusetts General Hospital
    6. (1 articles) Sun Yat-Sen University
    7. (1 articles) Carl Zeiss Meditec
    8. (1 articles) Nara Medical University
    9. (1 articles) University of Maryland
    10. (1 articles) University of Ulsan
    11. (1 articles) FDA
    12. (1 articles) Duke University
    13. (1 articles) University of Queensland
    14. (1 articles) Cleveland Clinic
    15. (1 articles) Kobe University Graduate School of Medicine
  3. Popular Articles

  4. Picture Gallery

    Association of Narrow Angles With Anterior Chamber Area and Volume Measured With Anterior-Segment Optical Coherence Tomography] A Simplified Method to Measure Choroidal Thickness Using Adaptive Compensation in Enhanced Depth Imaging Optical Coherence Tomography Relationship of ocular and systemic factors to the visibility of choroidal–scleral interface using spectral domain optical coherence tomography Detailed Phenotyping and Characterization of Choroidal Morphological and Vascular Features in Young Men with High Myopia Using Spectral-Domain Optical Coherence Tomography A novel algorithm for multiplicative speckle noise reduction in ex vivo human brain OCT images Volumetric characterization of microvasculature in ex vivo human brain samples by serial sectioning optical coherence tomography Depth of focus extension in optical coherence tomography using ultrahigh chromatic dispersion of zinc selenide Retinal changes in bipolar disorder as an endophenotype candidate: Comparison of OCT-detected retinal changes in patients, siblings, and healthy controls Intraoperative optical coherence tomography guided 25G micro-amount trajectory vitrectomy for the treatment of penetrating ocular injury caused by a foreign body in the right eye: A case study Optical coherence tomography angiography reveals paradoxically decreasing choroidal thickness & increasing blood flow in remitting Vogt Koyanagi Harada syndrome A comparison of macular ganglion cell and retinal nerve fibre layer optical coherence tomographic parameters as predictors of visual outcomes of surgery for pituitary tumours Fundus Changes Evaluated by OCTA in Patients With Cerebral Small Vessel Disease and Their Correlations: A Cross-Sectional Study