1. Articles from Mansik Jeon

    1-24 of 55 1 2 3 »
    1. Integrated Quad-Scanner Strategy-Based Optical Coherence Tomography for the Whole-Directional Volumetric Imaging of a Sample

      Integrated Quad-Scanner Strategy-Based Optical Coherence Tomography for the Whole-Directional Volumetric Imaging of a Sample

      Whole-directional scanning methodology is required to observe distinctive features of an entire physical structure with a three dimensional (3D) visualization. However, the implementation of whole-directional scanning is challenging for conventional optical coherence tomography (OCT), which scans a limited portion of the sample by utilizing unidirectional and bidirectional scanning methods. Therefore, in this paper an integrated quad-scanner (QS) strategy-based OCT method was implemented to obtain the whole-directional volumetry of a sample by employing four scanning arms installed around the sample. The simultaneous and sequential image acquisition capabilities are the conceptual key points of the proposed QS-OCT method, and were implemented using ...

      Read Full Article
    2. Identification of Organs Inside Hard Tick Body Using Spectral-domain Optical Coherence Tomography

      Identification of Organs Inside Hard Tick Body Using Spectral-domain Optical Coherence Tomography

      Ixodidae tick, also known as a hard tick, is one of the major vectors of various tick-borne diseases. Studying its anatomy is the fundamental approach for diverse acarological studies and the key to understanding tick morphology. However, the conventional methods of observing internal organs rely primarily on dissection, which damages specimens irrecoverably. In this study, we developed an optical coherence tomography (OCT) system to non-invasively investigate the morphological characteristics of the hard tick. Herein, OCT imaging was conducted by the developed spectral-domain OCT (SD-OCT) system with two different objective lenses. The developed system provides an axial resolution (in the air ...

      Read Full Article
    3. A preliminary study of post-progressive nail-art effects on in vivo nail plate using optical coherence tomography-based intensity profiling assessment

      A preliminary study of post-progressive nail-art effects on in vivo nail plate using optical coherence tomography-based intensity profiling assessment

      Nail beautification is a widely applied gender independent practice. Excessive nail beautifications and nail-arts have a direct impact on the nail structure and can cause nail disorders. Therefore, the assessment of post-progressive nail-art effects on the nail is essential to maintain optimal nail health and to avoid any undesirable disorders. In this study, in vivo nails were examined in control stage, with a nail-art stage, and after removing the nail-art stage using a 1310 nm spectral-domain optical coherence tomography (SD-OCT) system. The acquired cross-sectional OCT images were analyzed by a laboratory customized signal processing algorithm to obtain scattered intensity profiling ...

      Read Full Article
    4. Optical Coherence Tomography for Quantifying Human Cutaneous Chronic Graft-versus-Host Disease: OCT for cGvHD

      Optical Coherence Tomography for Quantifying Human Cutaneous Chronic Graft-versus-Host Disease: OCT for cGvHD

      Chronic graft versus host disease (cGvHD) is the most common cause of non-relapse mortality after allogeneic hematopoietic cell transplant (alloHCT). Cutaneous cGvHD is characterized by thickening of the skin and connective tissues resulting in discomfort and limitations in mobility. Current assessments of these skin lesions are based on physical examination of their thickening, pinchability, and movability. Optical coherence tomography (OCT) is a non-invasive, high-resolution technique using near infra-red light to interrogate tissues and image the microstructure without the use of contrast agents. We determined the applicability of OCT to human cutaneous cGvHD. Seven patients with varying degrees of cutaneous GvHD ...

      Read Full Article
    5. Vision-Inspection-Synchronized Dual Optical Coherence Tomography for High-Resolution Real-Time Multidimensional Defect Tracking in Optical Thin Film Industry

      Vision-Inspection-Synchronized Dual Optical Coherence Tomography for High-Resolution Real-Time Multidimensional Defect Tracking in Optical Thin Film Industry

      Large-scale product inspection is an important aspect in thin film industry to identify defects with a high precision. Although vision line scan camera (VLSC)-based inspection has been frequently implemented, it is limited to surface inspections. Therefore, to overcome the conventional drawbacks, there is a need to extend inspection capabilities to internal structures. Considering that VLSC systems have access to rich information, such as color and texture, high-resolution real-time multimodal optical synchronization between VLSC and dual spectral domain optical coherence tomography (SD-OCT) systems was developed with a laboratory customized in-built automated defect-tracking algorithm for optical thin films (OTFs). Distinguishable differences ...

      Read Full Article
    6. Multi-directional Morphological Assessment of Single Bacterial Colonies Through Non-invasive Optical Imaging

      Multi-directional Morphological Assessment of Single Bacterial Colonies Through Non-invasive Optical Imaging

      A bacterium in bacterial colony is a basal component of bacterial studies and is therefore of considerable importance. The morphological characteristics of a single colony have been widely used as the standard to identify diverse bacterial species. However, the conventional methods for obtaining morphological information, such as microscopic techniques, cannot provide tomographic views. This study utilizes spectral-domain optical coherence tomography (SD-OCT) to observe both external and internal structures for single colonies. OCT imaging provided a clear top (projection) and lateral (cross-sectional) images, which can identify distinct features in the fifteen different bacterial species examined. Through the acquired OCT images, the ...

      Read Full Article
    7. Intra-operative Optical Coherence Imaging of In-vivo Chronic Otitis Media followed by Post-operative Audiogram Assessments

      Intra-operative Optical Coherence Imaging of In-vivo Chronic Otitis Media followed by Post-operative Audiogram Assessments

      The successful surgery of chronic otitis media (COM) is challenging; this depends on the surgeon's knowledge of the optical visibility of surgical microscopes. Herein, we reported the utilization of intra-surgical optical coherence tomography (OCT) system to effectively guide the surgery of COM based on augmented reality with cross-sectional images. The intra-surgical spectral-domain OCT system with a center wavelength of 846 nm was capable of obtaining non-invasive, high-resolution, and high-speed visualizations with an axial resolution of 8 μm, lateral resolution of 30 μm, and an extended working distance of 280 mm. Three patients with COM were involved in this research ...

      Read Full Article
    8. Fabrication of Dental Crown by Optical Coherence Tomography: A Pilot Study

      Fabrication of Dental Crown by Optical Coherence Tomography: A Pilot Study

      Digital impressions have been studied for better gingival retraction in including the under subgingival finish line condition. Here, we employed swept-source optical coherence tomography (SS-OCT) of 1310 nm wavelength, which is capable of noninvasive, high-resolution, and high-speed, to discern the utilization-possibility for supporting the fabrication of the dental crown. A three-dimensional (3D) abutment was used at the 0.5 mm of the subgingival finish line below the level of the gingiva. The SS-OCT system scanned a field of view of 10 mm × 10 mm using the 3D working model by the depth-directional three focal points. The obtained 1500 images of ...

      Read Full Article
    9. Non-invasive optical screening of Streptococcus Pneumonia based inflammatory changes of the tympanic membrane and mastoid mucosa in guinea pig otitis media using optical coherence tomography

      Non-invasive optical screening of Streptococcus Pneumonia based inflammatory changes of the tympanic membrane and mastoid mucosa in guinea pig otitis media using optical coherence tomography

      Abstract: The accurate screening of otitis media (OM) lies in clarifying the numerous confounding and quantitative factors that are discovered during primary inspections. Increased awareness about bacterial biofilms and inflammation has allowed researchers to develop a better understanding of the bacterial infections that occur in the middle ear. In this study, four live guinea pigs were inoculated with Streptococcus pneumonia to induce OM-related inflammatory changes. Since optical techniques have been effectively used for diagnosis in medicine, low-coherence interferometry-based optical coherence tomography (OCT) was employed for depth-resolved high-resolution data screening. Multiple locations of the tympanic membrane (TM), mastoid mucosa, and round ...

      Read Full Article
    10. Assessment of the Inner Surface Roughness of 3D Printed Dental Crowns via Optical Coherence Tomography Using a Roughness Quantification Algorithm

      Assessment of the Inner Surface Roughness of 3D Printed Dental Crowns via Optical Coherence Tomography Using a Roughness Quantification Algorithm

      Abstract: Dental crowns are used to restore decayed or chipped teeth, where their surfaces play a key role in this restoration process, as they affect the fitting and stable bonding of the prostheses. The surface texture of crowns can interfere with this restoration process, therefore the measurement of their inner surface roughness is very important but difficult to achieve using conventional imaging methods. In this study, the inner surfaces of dental crowns were three-dimensionally (3D) visualized using swept-source optical coherence tomography (SS-OCT) system. Nine crowns were fabricated with a commercial 3D printer using three different hatching methods (one-way, cross, and ...

      Read Full Article
    11. Dynamic compensation of path length difference in optical coherence tomography by an automatic temperature control system of optical fiber

      Dynamic compensation of path length difference in optical coherence tomography by an automatic temperature control system of optical fiber

      Optical fiber is widely used in optical coherence tomography (OCT) to propagate light precisely with low attenuation and low dispersion. However, the total optical path length within the optical fiber varies in accordance with changes of the temperature. This leads changes in the total optical travel path of the interfering signals and results in shifting of OCT image position to an unintended depth pixel value. In this paper, we presented the temperature-based automatic path length compensating method in OCT to limit the external temperature effect and control the image position in micro-scale without manual movement of optical components. By utilizing ...

      Read Full Article
    12. Optical Interferometric Fringe Pattern-Incorporated Spectrum Calibration Technique for Enhanced Sensitivity of Spectral Domain Optical Coherence Tomography

      Optical Interferometric Fringe Pattern-Incorporated Spectrum Calibration Technique for Enhanced Sensitivity of Spectral Domain Optical Coherence Tomography

      Depth-visualizing sensitivity can be degraded due to imperfect optical alignment and non-equidistant distribution of optical signals in the pixel array, which requires a measurement of the re-sampling process. To enhance this depth-visualizing sensitivity, reference and sample arm-channeled spectra corresponding to different depths using mirrors were obtained to calibrate the spectrum sampling prior to Fourier transformation. During the process, eight interferogram patterns corresponding to point spread function (PSF) signals at eight optical path length differences were acquired. To calibrate the spectrum, generated intensity points of the original interferogram were re-indexed towards a maximum intensity range, and these interferogram re-indexing points were ...

      Read Full Article
    13. Identification of multi-dimensional thread geometry using depth-resolved swept-source optical coherence tomography for assessment of dental implant fabrication

      Identification of multi-dimensional thread geometry using depth-resolved swept-source optical coherence tomography for assessment of dental implant fabrication

      The geometrical characteristics of dental implants, such as thread depth and width, facing angle, pitch, and surface roughness, are important to assess their stability and osseointegration after implant surgery. Herein, we demonstrate the potential use of depth-resolved swept-source optical coherence tomography (SS-OCT) to assess the structural quality of widely used dental implants. The implemented SS-OCT system was centered at a wavelength of 1300 nm with a 100 nm full-width at half-maximum. Four dental implants with different structural formations fabricated using either titanium or ceramic were visualized. Qualitative assessments were performed using boundary flattening with an amplitude-profiling algorithm to emphasize and ...

      Read Full Article
    14. Measurement of Vibrating Tympanic Membrane in an In Vivo Mouse Model Using Doppler Optical Coherence Tomography

      Measurement of Vibrating Tympanic Membrane in an In Vivo Mouse Model Using Doppler Optical Coherence Tomography

      Optical coherence tomography (OCT) has a micro-resolution with a penetration depth of about 2 mm and field of view of about 10 mm. This makes OCT well suited for analyzing the anatomical and internal structural assessment of the middle ear. To study the vibratory motion of the tympanic membrane (TM) and its internal structure, we developed a phase-resolved Doppler OCT system using Kasai’s autocorrelation algorithm. Doppler optical coherence tomography is a powerful imaging tool which can offer the micro-vibratory measurement of the tympanic membrane and obtain the micrometer-resolved cross-sectional images of the sample in real-time. To observe the relative ...

      Read Full Article
    15. An averaged intensity difference detection algorithm for identification of human gingival sulcus in optical coherence tomography images

      An averaged intensity difference detection algorithm for identification of human gingival sulcus in optical coherence tomography images

      In the past decade, there has been an increase in the development of sensitive, highresolution, non-invasive diagnostic methods for periodontic diseases. Optical coherence tomography (OCT) has attracted considerable attention in clinical settings. In this study, a reliable, robust algorithm for the detection of gingival sulcus in 2D OCT cross-sectional images is proposed. Previously, the measurement of gingival sulcus in OCT images has been performed by manual identification using two-dimensional (2D) cross-sectional images. The automated detection of gingival sulcus continuity in 2D OCT images may help medical practitioners to assess important features of gingival tissues. The Sobel and canny operators have ...

      Read Full Article
    16. A Comparison Study of Marginal and Internal Fit Assessment Methods for Fixed Dental Prostheses

      A Comparison Study of Marginal and Internal Fit Assessment Methods for Fixed Dental Prostheses

      Numerous studies have previously evaluated the marginal and internal fit of fixed prostheses; however, few reports have performed an objective comparison of the various methods used for their assessment. The purpose of this study was to compare five marginal and internal fit assessment methods for fixed prostheses. A specially designed sample was used to measure the marginal and internal fit of the prosthesis according to the cross-sectional method (CSM), silicone replica technique (SRT), triple scan method (TSM), micro-computed tomography (MCT), and optical coherence tomography (OCT). The five methods showed significant differences in the four regions that were assessed ( p < 0 ...

      Read Full Article
    17. Non-Invasive Morphological Characterization of Rice Leaf Bulliform and Aerenchyma Cellular Regions Using Low Coherence Interferometry

      Non-Invasive Morphological Characterization of Rice Leaf Bulliform and Aerenchyma Cellular Regions Using Low Coherence Interferometry

      Non-invasive investigation of rice leaf specimens to characterize the morphological formation and particular structural information that is beneficial for agricultural perspective was demonstrated using a low coherence interferometric method called swept source optical coherence tomography (SS-OCT). The acquired results non-invasively revealed morphological properties of rice leaf, such as bulliform cells; aerenchyma, parenchyma, and collenchyma layer; and vascular bundle. Beside aforementioned morphologic characteristics, several leaf characteristics associated with cytological mechanisms of leaf rolling (leaf inclination) were examined for the pre-identification of inevitable necrosis and atrophy of leaf tissues by evaluating acute angle information, such as angular characteristics of the external bi-directional ...

      Read Full Article
    18. Analysis of Enamel Loss by Prophylaxis and Etching Treatment in Human Tooth Using Optical Coherence Tomography: An In Vitro Study

      Analysis of Enamel Loss by Prophylaxis and Etching Treatment in Human Tooth Using Optical Coherence Tomography: An In Vitro Study

      Bonding of braces is an essential part in contemporary orthodontic treatment. For the proper strength of bracket bonding, enamel conditioning or surface treatment on tooth surface is required. Treatment on the tooth surface such as prophylaxis smoothing with pumice and enamel etching results in considerable damages to the enamel surface of the tooth. In this study, we have proposed optical coherence tomography as a noninvasive imaging technique for the evaluation of damage induced during such treatment procedures. Using depth intensity analysis of the obtained cross-sectional images, the damage resulting to the enamel surface was studied after prophylaxis smoothening and etching ...

      Read Full Article
    19. 3-Dimensional characterization of cortical bone microdamage following placement of orthodontic microimplants using Optical Coherence Tomography

      3-Dimensional characterization of cortical bone microdamage following placement of orthodontic microimplants using Optical Coherence Tomography

      Microimplants are being used extensively in clinical practice to achieve absolute anchorage. Success of microimplant mainly depend on its primary stability onto the cortical bone surface and the associated Microdamage of the cortical bone during insertion procedure leads to many a microimplants to fail and dislodge from the cortical bone leading to its failure. Even though, previous studies showed occurrence of microdamage in the cortical bone, they were mainly 2-dimension studies or studies that were invasive to the host. In the present study, we used a non-invasive, non-ionizing imaging technique- Optical Coherence Tomography (OCT), to image and analyze the presence ...

      Read Full Article
    20. Clinical Utility of Intraoperative Tympanomastoidectomy Assessment Using a Surgical Microscope Integrated with an Optical Coherence Tomography

      Clinical Utility of Intraoperative Tympanomastoidectomy Assessment Using a Surgical Microscope Integrated with an Optical Coherence Tomography

      Significant technical and optical advances are required for intraoperative optical coherence tomography (OCT) to be utilized during otological surgeries. Integrating OCT with surgical microscopy makes it possible to evaluate soft tissue in real-time and at a high resolution. Herein, we describe an augmented-reality, intraoperative OCT/microscope system with an extended working distance of 280 mm, providing more space for surgical manipulation than conventional techniques. We initially performed ex vivo experiments to evaluate system performance. In addition, we validated the system by performing preliminary clinical assessments of tympanomastoidectomy outcomes in six patients with chronic otitis media. The system evaluated residual inflammation ...

      Read Full Article
    21. Non-destructive identification of weld-boundary and porosity formation during laser transmission welding by using optical coherence tomography

      Non-destructive identification of weld-boundary and porosity formation during laser transmission welding by using optical coherence tomography

      Laser transmission welding offers significant benefits over conventional welding techniques enabling single-stage rapid plastic joining. The quality of laser transmission welded products are commonly assessed by measuring the weld penetration depth, hardened weld boundary, and inspecting the formation of porosity. However, existing methods of verification are inevitably accompanied by destruction of the specimen. Thus, non-destructive quality assessment methods for laser transmission welding have gained attention recently. Here, we demonstrated an extended industrial application of 860 nm wavelength based spectral domain optical coherence tomography for the non-destructive inspection of the aforementioned quality parameters of laser transmission welded industrial plastic materials, i ...

      Read Full Article
    22. Assessment of cortical bone microdamage following insertion of microimplants using optical coherence tomography: a preliminary study

      Assessment of cortical bone microdamage following insertion of microimplants using optical coherence tomography: a preliminary study

      Objectives: The study was done to evaluate the efficacy of optical coherence tomography (OCT), to detect and analyze the microdamage occurring around the microimplant immediately following its placement, and to compare the findings with micro-computed tomography (μCT) images of the samples to validate the result of the present study. Methods: microimplant s were inserted into bovine bone samples. Images of the samples were obtained using OCT and μCT. Visual comparisons of the images were made to evaluate whether anatomical details and microdamage induced by microimplant insertion were accurately revealed by OCT. Results: The surface of the cortical bone with its ...

      Read Full Article
    23. Biophotonic approach for the characterization of initial bitter-rot progression on apple specimens using optical coherence tomography assessments

      Biophotonic approach for the characterization of initial bitter-rot progression on apple specimens using optical coherence tomography assessments

      The tremendous advances achieved in the biophotonics technologies have intensified the necessity for non-invasive modalities that can characterize diverse biological materials with increased sensitivity and resolution. Optical coherence tomography (OCT) is one of the techniques that has been applied for biological applications in medicine and agriculture to identify structural properties. Herein, we report the successful incorporation of OCT for the identification of morphological changes that occur as a result of the bitter rot disease, through continuous detection of structural changes. Detailed inner morphological structural changes occurring in fruit specimens were precisely analyzed as a function of the disease incubation period ...

      Read Full Article
    24. Numerical-Sampling-Functionalized Real-Time Index Regulation for Direct k-Domain Calibration in Spectral Domain Optical Coherence Tomography

      Numerical-Sampling-Functionalized Real-Time Index Regulation for Direct k-Domain Calibration in Spectral Domain Optical Coherence Tomography

      An index-regulation technique functionalized by numerical sampling for direct calibration of the non-linear wavenumber ( k )-domain to a linear domain in spectral domain optical coherence tomography (SD-OCT) is proposed. The objective of the developed method is to facilitate high-resolution identification of microstructures in biomedical imaging. Subjective optical alignments caused by nonlinear sampling of interferograms in the k -domain tend to hinder depth-dependent signal-to-noise ratios (SNR) and axial resolution in SD-OCT. Moreover, the optical-laser-dependent k -domain requires constant recalibrated in accordance with each laser transition, thereby necessitating either hardware or heavy software compensations. As the key feature of the proposed method ...

      Read Full Article
    1-24 of 55 1 2 3 »
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (55 articles) Mansik Jeon
    2. (53 articles) Kyungpook National University
    3. (51 articles) Jeehyun Kim
    4. (36 articles) Ruchire Eranga Wijesinghe
    5. (17 articles) Naresh Kumar Ravichandran
    6. (7 articles) Changho Lee
    7. (5 articles) Ajou University
    8. (5 articles) Jeong Hun Jang
    9. (3 articles) University of Illinois at Urbana-Champaign
    10. (3 articles) Stephen A. Boppart
    11. (2 articles) Optovue
    12. (1 articles) University of Houston
    13. (1 articles) Sun Yat-Sen University
    14. (1 articles) University of Wisconsin
    15. (1 articles) Manabu Kashiwagi
    16. (1 articles) Yasushi Ino
    17. (1 articles) Takashi Akasaka
    18. (1 articles) Salavat Aglyamov
    19. (1 articles) Manmohan Singh
    20. (1 articles) Kirill V. Larin
  3. Popular Articles

  4. Picture Gallery

    Handheld Optical Coherence Tomography Scanner for Primary Care Diagnostics Full-range k-domain linearization in spectral-domain optical coherence tomography Pulse Analyzing System Using Optical Coherence Tomography for Oriental Medical Application Dual-modal photoacoustic and optical coherence tomography using a single near-infrared supercontinuum laser source Combined photoacoustic and optical coherence tomography using a single near-infrared supercontinuum laser source Fast Industrial Inspection of Optical Thin Film Using Optical Coherence Tomography Optical sensing method to analyze germination rate of Capsicum annum seeds treated with growth-promoting chemical compounds using optical coherence tomography In vivo 3D imaging of the human tympanic membrane using a wide-field diagonal-scanning optical coherence tomography probe Application of wearable optical coherence tomography (OCT) and Loop-mediated isothermal amplification (LAMP) techniques for In situ real-time field inspection of apple Marssonina blotch disease Feature Of The Week 09/17/2017: Non-Destructive Analysis of the Internal Anatomical Structures of Mosquito Specimens Using Optical Coherence Tomography Imaging Hyperreflective Foci as an Inflammatory Biomarker after Anti-VEGF Treatment in Neovascular Age-Related Macular Degeneration Patients with Optical Coherence Tomography Angiography Radiation-Induced Optical Coherence Tomography Angiography Retinal Alterations in Patients With Nasopharyngeal Carcinoma