1. Articles from Aleksandre Matiashvili

    1-8 of 8
    1. Volumetric assessment of lesion severity with optical coherence tomography: relationship with fractional flow reserve

      Volumetric assessment of lesion severity with optical coherence tomography: relationship with fractional flow reserve

      Aims: Frequency-domain optical coherence tomography (FD-OCT) provides a rapid tomographic scan of a coronary vessel, with an accurate reconstruction of its lumen profile. An FD-OCT-based metric that corresponds more closely with physiological significance of lesions may enable more precise guidance of interventional procedures. The aim of this feasibility study was to evaluate a new method for quantifying coronary lesion severity that estimates hyperaemic flow resistance of branched vessel segments imaged by FD-OCT. Methods and results: An analytical flow model was developed that relates fractional flow reserve (FFR) to the vascular resistance ratio (VRR), a measure of blood flow resistance derived ...

      Read Full Article
    2. Serial Assessment of Coronary Artery Response to Paclitaxel-Eluting Stents Using Optical Coherence Tomography

      Serial Assessment of Coronary Artery Response to Paclitaxel-Eluting Stents Using Optical Coherence Tomography

      Background—The paucity of longitudinal, serial high-resolution imaging studies has limited our understanding of in vivo arterial response to drug-eluting stents. We sought to investigate the human coronary response to paclitaxel-eluting stent implantation, using serial optical coherence tomography assessments. Methods and Results—Thirty patients with at least 2 significant coronary lesions in different vessels were treated with a paclitaxel-eluting stent. The most severe stenosis (lesion A) was treated at the initial procedure, and the second target vessel (lesion B) was stented 3 months later. Optical coherence tomography was performed at baseline, 3-, and 9-month follow-up for lesions A and baseline ...

      Read Full Article
    3. Examination of the In Vivo Mechanisms of Late Drug-Eluting Stent Thrombosis: Findings From Optical Coherence Tomography and Intravascular Ultrasound Imaging

      Examination of the In Vivo Mechanisms of Late Drug-Eluting Stent Thrombosis: Findings From Optical Coherence Tomography and Intravascular Ultrasound Imaging
      Objectives: This study investigated the role of uncovered stent struts on late stent thrombosis (LST) after drug-eluting stent (DES) implantation with optical coherence tomography (OCT). Background: Autopsy studies have identified delayed healing and lack of endothelialization of DES struts as the hallmarks of LST. DES strut coverage has not previously been examined in vivo in patients with LST. Methods: We studied 54 patients, including 18 with DES LST (median 615 days after implant) undergoing emergent percutaneous coronary interventions and 36 matched DES control subjects undergoing routine repeat OCT and intravascular ultrasound (IVUS) who did not experience LST for 3 years ...
      Read Full Article
    4. Impact of Drug Release Kinetics on Vascular Response to Different Zotarolimus-Eluting Stents Implanted in Patients With Long Coronary Stenoses: The LongOCT Study (Optical Coherence Tomography in Long Lesions)

      Impact of Drug Release Kinetics on Vascular Response to Different Zotarolimus-Eluting Stents Implanted in Patients With Long Coronary Stenoses: The LongOCT Study (Optical Coherence Tomography in Long Lesions)
      Objectives We assessed the in vivo vascular response to a new generation of zotarolimus-eluting stents (ZES) with prolonged drug release (Resolute ZES-SR, Medtronic Vascular, Santa Rosa, California) compared with ZES with faster kinetics (Endeavor ZES-FR, Medtronic Vascular) by optical coherence tomography. Background Local drug release kinetics has been implicated with antirestenosis efficacy of drug-eluting stents. However, the impact of different release kinetics on vascular response of diseased human coronary arteries remains to be investigated. Methods The study population consisted of 43 patients with long lesions in native coronary vessels treated with multiple overlapping ZES. Twenty-one patients treated with ZES-SR were ...
      Read Full Article
    5. Strut Coverage and Late Malapposition With Paclitaxel-Eluting Stents Compared With Bare Metal Stents in Acute Myocardial Infarction: OCT Substudy of the Harmonizing Outcomes With Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI)

      Strut Coverage and Late Malapposition With Paclitaxel-Eluting Stents Compared With Bare Metal Stents in Acute Myocardial Infarction: OCT Substudy of the Harmonizing Outcomes With Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI)
      Background— The safety of drug-eluting stents in ST-segment elevation myocardial infarction (STEMI) continues to be debated. Pathological studies have demonstrated an association between uncovered struts and subsequent stent thrombosis. Optical coherence tomography can detect stent strut coverage in vivo on a micron-scale level. We therefore used optical coherence tomography to examine strut coverage in patients with STEMI treated with paclitaxel-eluting stents (PES) and bare metal stents (BMS). Methods and Results— In the Harmonizing Outcomes With Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) trial, patients with STEMI were randomized 3:1 to PES or BMS implantation. In a formal substudy ...
      Read Full Article
    6. Strut Coverage and Vessel Wall Response to a New-Generation Paclitaxel-Eluting Stent With an Ultrathin Biodegradable Abluminal Polymer: Optical Coherence Tomography Drug-Eluting Stent Investigation (OCTDESI)

      Strut Coverage and Vessel Wall Response to a New-Generation Paclitaxel-Eluting Stent With an Ultrathin Biodegradable Abluminal Polymer: Optical Coherence Tomography Drug-Eluting Stent Investigation (OCTDESI)
      Background—Polymer-coated drug-eluting stents are effective in preventing restenosis but have been associated with delayed healing and incomplete strut coverage. It is unknown whether paclitaxel-eluting stents (PES) with minimal biodegradable abluminal coating enhances strut coverage while preventing neointimal hyperplasia. Using optical coherence tomography (OCT) as a primary imaging modality, we assessed the proportion of uncovered struts at 6-month follow-up in PES coated with durable versus ultrathin (<1 µ m) biodegradable abluminal polymers. Methods and Results—In this pilot trial, 60 patients with de novo lesions (25 mm) in native coronary vessels were randomly assigned to receive either TAXUS Liberté PES ...
      Read Full Article
    7. Strut Coverage and Vessel Wall Response to Zotarolimus-Eluting and Bare-Metal Stents Implanted in Patients With ST-Segment Elevation Myocardial Infarction: The Octami (Optical Coherence Tomography in Acute Myocardial Infarction) Study

      Strut Coverage and Vessel Wall Response to Zotarolimus-Eluting and Bare-Metal Stents Implanted in Patients With ST-Segment Elevation Myocardial Infarction: The Octami (Optical Coherence Tomography in Acute Myocardial Infarction) Study
      Objectives Using optical coherence tomography, we assessed the proportion of uncovered struts at 6-month follow-up in zotarolimus-eluting stents (ZES), specifically Endeavor (Medtronic CardioVascular, Santa Rosa, California) stents, and identical bare-metal stents (BMS) implanted in patients with ST-segment elevation myocardial infarction (STEMI). Background Sirolimus- and paclitaxel-eluting stents implanted in STEMI have been associated with delayed healing and incomplete strut coverage. ZES are associated with a more complete and uniform strut coverage in stable patients, but whether this holds true also after STEMI is unknown. Methods Forty-four patients with STEMI who underwent primary PCI were randomized to ZES or BMS (3:1 ...
      Read Full Article
    8. Optical Coherence Tomography Assessment of In Vivo Vascular Response After Implantation of Overlapping Bare-Metal and Drug-Eluting Stents

      Optical Coherence Tomography Assessment of In Vivo Vascular Response After Implantation of Overlapping Bare-Metal and Drug-Eluting Stents
      Objectives We designed a randomized trial exploiting optical coherence tomography (OCT) to assess coverage and apposition of overlapping bare-metal stents (BMS) and drug-eluting stents (DES) in human coronary arteries. Background Overlapping DES impair healing in animals. Optical coherence tomography allows accurate in vivo assessment of stent strut coverage and apposition. Methods Seventy-seven patients with long coronary stenoses were randomized to overlapping sirolimus-eluting stents (SES), paclitaxel-eluting stents (PES), zotarolimus-eluting stents (ZES), or BMS. The primary goal of the study was to determine the rate of uncovered/malapposed struts in overlap versus nonoverlap segments, according to stent type, at 6-month follow-up with ...
      Read Full Article
    1-8 of 8
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (8 articles) Ospedali Riuniti di Bergamo
    2. (7 articles) Case Western Reserve University
    3. (2 articles) Cardiovascular Research Foundation
    4. (2 articles) University of Catania
    5. (2 articles) Columbia University
    6. (2 articles) Abbott
    7. (1 articles) Beth Israel Deaconess Medical Center
    8. (1 articles) Boston Scientific
    9. (1 articles) Academic Medical Center at the University of Amsterdam
    10. (1 articles) University College London
    11. (1 articles) University of Cologne
  3. Popular Articles

  4. Picture Gallery

    Optical Coherence Tomography Assessment of In Vivo Vascular Response After Implantation of Overlapping Bare-Metal and Drug-Eluting Stents Strut Coverage and Vessel Wall Response to Zotarolimus-Eluting and Bare-Metal Stents Implanted in Patients With ST-Segment Elevation Myocardial Infarction: The Octami (Optical Coherence Tomography in Acute Myocardial Infarction) Study Strut Coverage and Vessel Wall Response to a New-Generation Paclitaxel-Eluting Stent With an Ultrathin Biodegradable Abluminal Polymer: Optical Coherence Tomography Drug-Eluting Stent Investigation (OCTDESI) Strut Coverage and Late Malapposition With Paclitaxel-Eluting Stents Compared With Bare Metal Stents in Acute Myocardial Infarction: OCT Substudy of the Harmonizing Outcomes With Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) Impact of Drug Release Kinetics on Vascular Response to Different Zotarolimus-Eluting Stents Implanted in Patients With Long Coronary Stenoses: The LongOCT Study (Optical Coherence Tomography in Long Lesions) Examination of the In Vivo Mechanisms of Late Drug-Eluting Stent Thrombosis: Findings From Optical Coherence Tomography and Intravascular Ultrasound Imaging Serial Assessment of Coronary Artery Response to Paclitaxel-Eluting Stents Using Optical Coherence Tomography Volumetric assessment of lesion severity with optical coherence tomography: relationship with fractional flow reserve A Deep Learning Framework for the Detection and Quantification of Reticular Pseudodrusen and Drusen on Optical Coherence Tomography Quantitative assessment of textural features in the early detection of diabetic retinopathy with optical coherence tomography angiography Line-field confocal optical coherence tomography of fibroepithelioma of Pinkus Assessment of demineralized tooth lesions using optical coherence tomography and other state-of-the-art technologies: a review