1. Articles from g. de crecchio

    1-5 of 5
    1. Evaluation of Vascular Changes with Optical Coherence Tomography Angiography after Plaque Radiotherapy of Choroidal Melanoma

      Evaluation of Vascular Changes with Optical Coherence Tomography Angiography after Plaque Radiotherapy of Choroidal Melanoma

      Aim: The purpose of this paper was to evaluate whether optical coherence tomography angiography (OCT-A) can be used to quantify the vascular changes in radiation maculopathy, and changes in the tumor vasculature in eyes treated with plaque radiotherapy for choroidal melanoma. Methods: In this prospective study, we evaluated 39 Caucasian patients with choroidal melanoma (39 eyes) treated with ruthenium-106 plaque radiotherapy. The patients underwent complete ophthalmic examination, bulbar echography, and OCT-A before and 1 year after treatment. Results: At baseline, the mean best-corrected visual acuity (BCVA) in the affected eyes was 0.35 ± 0.40 logMAR, and the mean tumor ...

      Read Full Article
    2. Evaluation of choroidal tumors with optical coherence tomography: enhanced depth imaging and OCT-angiography features

      Evaluation of choroidal tumors with optical coherence tomography: enhanced depth imaging and OCT-angiography features

      Aim To describe the vascular features of choroidal tumors using enhanced depth imaging (EDI), optical coherence tomography (OCT), and OCT-angiography. Methods In this prospective study, we evaluated 116 Caucasian patients with choroidal tumors (60 eyes with choroidal nevi, 40 with choroidal melanoma, 6 with choroidal hemangioma, 2 with optic disc melanocytoma, 6 with choroidal osteoma, and 2 with retinal metastases). Patients underwent a complete ophthalmic examination including bulbar echography, EDI-OCT, OCT-angiography, and multicolor imaging. Sixteen patients also underwent fluorescein and indocyanine angiography. Results The left eye was more involved than the right eye. The mean tumor thickness was 1.23 ...

      Read Full Article
    3. Comparison of time domain Stratus OCT and spectral domain SLO/OCT for assessment of macular thickness and volume

      Purpose To compare retinal thickness and volume measurements obtained with Stratus time domain optical coherence tomography (OCT) and spectral domain scanning laser ophthalmoscope OCT (SD-SLO/OCT). Methods In a cross-sectional study, 52 eyes with a normal macula, 30 eyes with retinal oedema, and 10 eyes with a myopia higher than 6 D have been...
      Read Full Article
    4. En Face Optical Coherence Tomography of the Posterior Pole in High Myopia.

      PURPOSE: To evaluate a large series of patients affected by high myopia using multiplanar imaging provided by en face optical coherence tomography (OCT). DESIGN: Observational cross-sectional study. METHODS: En face OCT longitudinal cross-sectional B scans and coronal C scans were obtained in 200 eyes of 100 patients with myopia greater than -6 diopters and evidence of posterior staphyloma at fundus examination and at ultrasound B-scan evaluation. RESULTS: A macular hole was present in three eyes (1.5%). We detected posterior retinal detachment in 37 cases (18.5%). In 15 eyes (7.5%) detachment was associated with a macular hole. In ...
      Read Full Article
    5. Evaluation of peripapillary detachment in pathologic myopia with en face optical coherence tomography

      Background A newly recognized lesion in pathologic myopia is peripapillary detachment of the retinal pigment epithelium (RPE) and retina. Recently introduced en face optical coherence tomography (OCT) provides not only cross-sectional but also coronal scans of the retina, and allows lateral extent visualization and thickness measurement of lesions. Methods Three patients presenting bilateral peripapillary yellow-orange lobulated area in high myopia have been evaluated with fluorescein angiography (FA), indocyanine green angiography (ICGA), en face OCT (OCT/SLO; Ophthalmic Technologies Inc, Toronto, Canada), and Humphrey visual field analyzer. Results In all eyes, en face OCT has shown the presence of a peripapillary ...
      Read Full Article
    1-5 of 5
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (4 articles) University Federico II
    2. (2 articles) Optos
    3. (1 articles) Carl Zeiss Meditec
    4. (1 articles) University of Washington
    5. (1 articles) University of Lübeck
    6. (1 articles) Ruikang K. Wang
  3. Popular Articles

  4. Picture Gallery

    Evaluation of choroidal tumors with optical coherence tomography: enhanced depth imaging and OCT-angiography features Evaluation of Vascular Changes with Optical Coherence Tomography Angiography after Plaque Radiotherapy of Choroidal Melanoma Optical microangiography reveals temporal and depth-resolved hemodynamic change in mouse barrel cortex during whisker stimulation Optical coherence tomography for fast bedside imaging, assessment and monitoring of autoimmune inflammatory skin diseases? Monitoring fatigue damage in different CAD/CAM materials: A new approach with optical coherence tomography. Automatic diagnosis of macular diseases from OCT volume based on its two-dimensional feature map and convolutional neural network with attention mechanism. Characteristics of the Filtering Bleb and the Agreement between Glaucoma Specialist and Anterior Segment OCT Assessment. Using swept-source OCT and OCT angiography to image choroidal tumours Evaluation of Age-related Skin Changes and Instrument Reliability Using Clinical Probe Measurements and Imaging Modalities HP-OCT™ wins Victorian AEEA award – nominated for Sir William Hudson award Postdoctoral Scholar in High Resolution Retinal Imaging at The Ohio State University Cone Photoreceptor Integrity assessed with Adaptive Optics Imaging after Laser-Pointer-Induced Retinal Injury