1. Articles from gesa palte

    1-4 of 4
    1. Chromatic polarization effects of swept waveforms in FDML lasers and fiber spools

      Chromatic polarization effects of swept waveforms in FDML lasers and fiber spools

      We present detailed investigations of chromatic polarization effects, caused by fiber spools used in FDML lasers and buffering spools for rapidly wavelength swept lasers. We introduce a novel wavelength swept FDML laser source, specially tailored for polarization sensitive optical coherence tomography (OCT) which switches between two different linear polarization states separated by 45°, i.e. 90° on the Poincaré sphere. The polarization maintaining laser cavity itself generates a stable linear polarization state and uses an external buffering technique in order to provide alternating polarization states for successive wavelength sweeps. The design of the setup is based on a comprehensive analysis ...

      Read Full Article
    2. Raman-pumped Fourier-domain mode-locked laser: analysis of operation and application for optical coherence tomography

      We demonstrate a Raman-pumped Fourier-domain mode-locked (FDML) fiber laser and optical coherence tomography imaging with this source. The wavelength sweep range of only 30 nm centered around 1550 nm results in limited axial resolution, hence a nonbiological sample is imaged. An output power of 1.9 ... [Opt. Lett. 33, 2815-2817 (2008)]
      Read Full Article
    3. Real time en face Fourier-domain optical coherence tomography with direct hardware frequency demodulation

      We demonstrate en face swept source optical coherence tomography (ss-OCT) without requiring a Fourier transformation step. The electronic optical coherence tomography (OCT) interference signal from a k-space linear Fourier domain mode-locked laser is mixed with an adjustable local oscillator, ... [Opt. Lett. 33, 2556-2558 (2008)]
      Read Full Article
    4. K-space linear Fourier domain mode locked laser and applications for optical coherence tomography

      We report on a Fourier Domain Mode Locked (FDML) wavelength swept laser source with a highly linear time-frequency sweep characteristic and demonstrate OCT imaging without k-space resampling prior to Fourier transformation. A detailed theoretical framework is provided and different strategies ... [Opt. Express 16, 8916-8937 (2008)]
      Read Full Article
    1-4 of 4
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (4 articles) Ludwig Maximilian University of Munich
    2. (4 articles) Robert A. Huber
    3. (4 articles) Benjamin R. Biedermann
    4. (4 articles) Christoph M. Eigenwillig
    5. (3 articles) Wolfgang Wieser
    6. (1 articles) Massachusetts Institute of Technology
    7. (1 articles) Vivek J. Srinivasan
    8. (1 articles) Desmond C. Adler
    9. (1 articles) James G. Fujimoto
    10. (1 articles) Thomas Klein
    11. (1 articles) Thomas Jefferson University
    12. (1 articles) Massachusetts General Hospital
    13. (1 articles) Polytechnique Montreal
    14. (1 articles) Wakayama Medical University
    15. (1 articles) Masamichi Takano
    16. (1 articles) Carol L. Shields
    17. (1 articles) Ik-Kyung Jang
    18. (1 articles) Theo Lasser
    19. (1 articles) Christoph Hauger
    20. (1 articles) Carl Zeiss Meditec
  3. Popular Articles

  4. Picture Gallery

    Chromatic polarization effects of swept waveforms in FDML lasers and fiber spools Residual thrombus following plaque disruption contributes to rapid plaque progression: in-vivo serial optical coherence tomography imaging Pigmented Iris Lesion on Anterior-Segment Swept-Source Optical Coherence Tomography Corneal epithelial thickness analysis of forme fruste keratoconus with optical coherence tomography Saline as an alternative to radio-contrast for optical coherence tomography guided percutaneous coronary intervention: A prospective comparison Soliton microcomb based spectral domain optical coherence tomography Myocardial infarction with non-obstructive coronary arteries (MINOCA): Intracoronary imaging-based diagnosis and management Optical coherence tomography-guided percutaneous coronary intervention: a review of current clinical applications Initial Study for the Determination of the Sequence of Intersecting Lines between Gel Pens and Seals by Optical Coherence Tomography Intraoperative optical coherence tomography-assisted displacement of prepapillary membrane in eyes with optic disc pit maculopathy Morphological Characteristics of Eroded Plaques with Noncritical Coronary Stenosis: An Optical Coherence Tomography Study Choriocapillaris flow impairment in type 3 macular neovascularization: a quantitative analysis using swept-source optical coherence tomography angiography