    1. Chromatic polarization effects of swept waveforms in FDML lasers and fiber spools

      Chromatic polarization effects of swept waveforms in FDML lasers and fiber spools

      We present detailed investigations of chromatic polarization effects, caused by fiber spools used in FDML lasers and buffering spools for rapidly wavelength swept lasers. We introduce a novel wavelength swept FDML laser source, specially tailored for polarization sensitive optical coherence tomography (OCT) which switches between two different linear polarization states separated by 45°, i.e. 90° on the Poincaré sphere. The polarization maintaining laser cavity itself generates a stable linear polarization state and uses an external buffering technique in order to provide alternating polarization states for successive wavelength sweeps. The design of the setup is based on a comprehensive analysis ...

      Read Full Article
    2. Raman-pumped Fourier-domain mode-locked laser: analysis of operation and application for optical coherence tomography

      We demonstrate a Raman-pumped Fourier-domain mode-locked (FDML) fiber laser and optical coherence tomography imaging with this source. The wavelength sweep range of only 30 nm centered around 1550 nm results in limited axial resolution, hence a nonbiological sample is imaged. An output power of 1.9 ... [Opt. Lett. 33, 2815-2817 (2008)]
      Read Full Article
    3. Real time en face Fourier-domain optical coherence tomography with direct hardware frequency demodulation

      We demonstrate en face swept source optical coherence tomography (ss-OCT) without requiring a Fourier transformation step. The electronic optical coherence tomography (OCT) interference signal from a k-space linear Fourier domain mode-locked laser is mixed with an adjustable local oscillator, ... [Opt. Lett. 33, 2556-2558 (2008)]
      Read Full Article
    4. K-space linear Fourier domain mode locked laser and applications for optical coherence tomography

      We report on a Fourier Domain Mode Locked (FDML) wavelength swept laser source with a highly linear time-frequency sweep characteristic and demonstrate OCT imaging without k-space resampling prior to Fourier transformation. A detailed theoretical framework is provided and different strategies ... [Opt. Express 16, 8916-8937 (2008)]
      Read Full Article
    1-4 of 4
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (4 articles) Ludwig Maximilian University of Munich
    2. (4 articles) Robert A. Huber
    3. (4 articles) Benjamin R. Biedermann
    4. (4 articles) Christoph M. Eigenwillig
    5. (3 articles) Wolfgang Wieser
    6. (1 articles) Massachusetts Institute of Technology
    7. (1 articles) Vivek J. Srinivasan
    8. (1 articles) Desmond C. Adler
    9. (1 articles) James G. Fujimoto
    10. (1 articles) Thomas Klein
  3. Popular Articles

  4. Picture Gallery

    Chromatic polarization effects of swept waveforms in FDML lasers and fiber spools Combining Deep Learning With Optical Coherence Tomography Imaging to Determine Scalp Hair and Follicle Counts Efficacy and Safety of Laser‐Assisted Combination Chemotherapy: An Explorative Imaging‐Guided Treatment With 5‐Fluorouracil and Cisplatin for Basal Cell Carcinoma A NOVEL FINDING OF HYPERREFLECTIVE MATERIAL IN THE SILICONE-RETINA INTERFACE: An Optical Coherence Tomographic and Histopathological Study SWEPT SOURCE OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY, FLUORESCEIN ANGIOGRAPHY, AND INDOCYANINE GREEN ANGIOGRAPHY COMPARISONS REVISITED: Using a Novel Deep-Learning-Assisted Approach for Image Registration AUTOMATED RETINAL LAYER SEGMENTATION AND THEIR THICKNESS PROFILES IN HEALTHY SUBJECTS: A Comparison of 55° Wide-field and Conventional 30° Spectral Domain-Optical Coherence Tomography RELATIONSHIP BETWEEN PREOPERATIVE FOVEAL MICROSTRUCTURE AND VISUAL ACUITY IN MACULA-OFF RHEGMATOGENOUS RETINAL DETACHMENT: Imaging Analysis by Swept Source Optical Coherence Tomography Vitreous Seeding in Retinocytoma: Importance of Optical Coherence Tomography Utility of Spectral-Domain Optical Coherence Tomography in Differentiating Papilledema From Pseudopapilledema: A Prospective Longitudinal Study Visualizing and quantifying cutaneous microvascular reactivity in humans using optical coherence tomography: Impaired dilator function in diabetes Optical Coherence Tomography of Outer Retinal Hyper-Reflectivity, Neovascularization and Pigment in Type 2 Macular Telangiectasia Early Detection of Incipient Retinal Pigment Epithelium Atrophy Overlying Drusen with Fundus Autofluorescence vs. Spectral Domain Optical Coherence Tomography