    1. Dueling Deep Q-Network for Unsupervised Inter-frame Eye Movement Correction in Optical Coherence Tomography Volumes

      Dueling Deep Q-Network for Unsupervised Inter-frame Eye Movement Correction in Optical Coherence Tomography Volumes

      In optical coherence tomography (OCT) volumes of retina, the sequential acquisition of the individual slices makes this modality prone to motion artifacts, misalignments between adjacent slices being the most noticeable. Any distortion in OCT volumes can bias structural analysis and influence the outcome of longitudinal studies. On the other hand, presence of speckle noise that is characteristic of this imaging modality, leads to inaccuracies when traditional registration techniques are employed. Also, the lack of a well-defined ground truth makes supervised deep-learning techniques ill-posed to tackle the problem. In this paper, we tackle these issues by using deep reinforcement learning to ...

      Read Full Article
    2. ASSESSING THE ABILITY OF PREOPERATIVE QUANTITATIVE SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY CHARACTERISTICS TO PREDICT VISUAL OUTCOME IN IDIOPATHIC MACULAR HOLE SURGERY

      ASSESSING THE ABILITY OF PREOPERATIVE QUANTITATIVE SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY CHARACTERISTICS TO PREDICT VISUAL OUTCOME IN IDIOPATHIC MACULAR HOLE SURGERY

      Purpose: To determine which spectral domain optical coherence tomography biomarkers of idiopathic macular hole (MH) correlate with the postoperative best-corrected visual acuity (BCVA) in anatomically closed MH. Methods: Retrospective analysis of spectral domain optical coherence tomography scans of 44 patients presenting with MH followed for a mean of 17 months. Widths of MH aperture, base, and ellipsoid zone disruption were calculated from presenting foveal spectral domain optical coherence tomography B-scans. Macular hole base area and ellipsoid zone disruption area were calculated through the custom in-house software. Results: Poorer postoperative BCVA correlated with increased preoperative choroidal hypertransmission (r = 0.503, P ...

      Read Full Article
    3. Retinal blood flow reduction in normal-tension glaucoma with single-hemifield damage by Doppler optical coherence tomography

      Retinal blood flow reduction in normal-tension glaucoma with single-hemifield damage by Doppler optical coherence tomography

      Aims To evaluate the associations between retinal blood flow (RBF) and optical coherence tomography (OCT) structural measurements in normal-tension glaucoma (NTG) eyes with single-hemifield visual field (VF) damage by the Doppler OCT. Methods The Doppler OCT was used to measure temporal artery (TA) RBF and temporal vein (TV) RBF. Retinal nerve fibre layer thickness (RNFLT) was measured by spectral-domain OCT. Results Forty-three consecutive eyes of 43 patients with NTG with VF defect confined to a single hemifield and 24 eyes of 24 age-matched healthy subjects were studied. TA and TV RBF and RNFLT were reduced in the damaged hemisphere compared ...

      Read Full Article
    4. 3D-CNN for Glaucoma Detection Using Optical Coherence Tomography

      3D-CNN for Glaucoma Detection Using Optical Coherence Tomography

      The large size of raw 3D optical coherence tomography (OCT) volumes poses challenges for deep learning methods as it cannot be accommodated on a single GPU in its original resolution. The direct analysis of these volumes however, provides advantages such as circumventing the need for the segmentation of retinal structures. Previously, a deep learning (DL) approach was proposed for the detection of glaucoma directly from 3D OCT volumes, where the volumes were significantly downsampled first. In this paper, we propose an end-to-end DL model for the detection of glaucoma that doubles the number of input voxels of the previously proposed ...

      Read Full Article
    5. Inference of visual field test performance from OCT volumes using deep learning

      Inference of visual field test performance from OCT volumes using deep learning

      Visual field tests (VFT) are pivotal for glaucoma diagnosis and conducted regularly to monitor disease progression. Here we address the question to what degree aggregate VFT measurements such as Visual Field Index (VFI) and Mean Deviation (MD) can be inferred from Optical Coherence Tomography (OCT) scans of the Optic Nerve Head (ONH) or the macula. Accurate inference of VFT measurements from OCT could reduce examination time and cost. We propose a novel 3D Convolutional Neural Network (CNN) for this task and compare its accuracy with classical machine learning (ML) algorithms trained on common, segmentation-based OCT, features employed for glaucoma diagnostics ...

      Read Full Article
    6. A feature agnostic approach for glaucoma detection in OCT volumes

      A feature agnostic approach for glaucoma detection in OCT volumes

      Optical coherence tomography (OCT) based measurements of retinal layer thickness, such as the retinal nerve fibre layer (RNFL) and the ganglion cell with inner plexiform layer (GCIPL) are commonly employed for the diagnosis and monitoring of glaucoma. Previously, machine learning techniques have relied on segmentation-based imaging features such as the peripapillary RNFL thickness and the cup-to-disc ratio. Here, we propose a deep learning technique that classifies eyes as healthy or glaucomatous directly from raw, unsegmented OCT volumes of the optic nerve head (ONH) using a 3D Convolutional Neural Network (CNN). We compared the accuracy of this technique with various feature-based ...

      Read Full Article
    7. Designing visible-light optical coherence tomography towards clinics

      Designing visible-light optical coherence tomography towards clinics

      Background: The capabilities of visible-light optical coherence tomography (vis-OCT) in noninvasive anatomical and functional retinal imaging have been demonstrated by multiple groups in both rodents and healthy human subjects. Translating laboratory prototypes to an integrated clinical-environment-friendly system is required to explore the full potential of vis-OCT in disease management. Methods: We developed and optimized a portable vis-OCT system for human retinal imaging in clinical settings. We acquired raster- and circular-scan images from both healthy and diseased human eyes. Results: The new vis-OCT provided high-quality retinal images of both subjects without any known eye diseases and patients with various retinal diseases ...

      Read Full Article
    8. Retinal optical coherence tomography image enhancement via deep learning

      Retinal optical coherence tomography image enhancement via deep learning

      Optical coherence tomography (OCT) images of the retina are a powerful tool for diagnosing and monitoring eye disease. However, they are plagued by speckle noise, which reduces image quality and reliability of assessment. This paper introduces a novel speckle reduction method inspired by the recent successes of deep learning in medical imaging. We present two versions of the network to reflect the needs and preferences of different end-users. Specifically, we train a convolution neural network to denoise cross-sections from OCT volumes of healthy eyes using either (1) mean-squared error, or (2) a generative adversarial network (GAN) with Wasserstein distance and ...

      Read Full Article
    9. The Future of Imaging in Detecting Glaucoma Progression

      The Future of Imaging in Detecting Glaucoma Progression

      Ocular imaging has been heavily incorporated into glaucoma management and provides important information that aids in the detection of disease progression. Longitudinal studies have shown that the circumpapillary retinal nerve fiber layer is an important parameter for glaucoma progression detection, whereas other studies have demonstrated that macular parameters, such as the ganglion cell inner plexiform layer and optic nerve head parameters, also are useful for progression detection. The introduction of novel technologies with faster scan speeds, wider scanning fields, higher resolution, and improved tissue penetration has enabled the precise quantification of additional key ocular structures, such as the individual retinal ...

      Read Full Article
    10. Signal Normalization Reduces Image Appearance Disparity Among Multiple Optical Coherence Tomography Devices

      Signal Normalization Reduces Image Appearance Disparity Among Multiple Optical Coherence Tomography Devices

      Purpose : To assess the effect of the previously reported optical coherence tomography (OCT) signal normalization method on reducing the discrepancies in image appearance among spectral-domain OCT (SD-OCT) devices. Methods : Healthy eyes and eyes with various retinal pathologies were scanned at the macular region using similar volumetric scan patterns with at least two out of three SD-OCT devices at the same visit (Cirrus HD-OCT, Zeiss, Dublin, CA; RTVue, Optovue, Fremont, CA; and Spectralis, Heidelberg Engineering, Heidelberg, Germany). All the images were processed with the signal normalization. A set of images formed a questionnaire with 24 pairs of cross-sectional images from each ...

      Read Full Article
    11. Adaptive optics optical coherence tomography in glaucoma

      Adaptive optics optical coherence tomography in glaucoma

      Since the introduction of commercial optical coherence tomography (OCT) systems, the ophthalmic imaging modality has rapidly expanded and it has since changed the paradigm of visualization of the retina and revolutionized the management and diagnosis of neuro-retinal diseases, including glaucoma. OCT remains a dynamic and evolving imaging modality, growing from time-domain OCT to the improved spectral-domain OCT, adapting novel image analysis and processing methods, and onto the newer swept-source OCT and the implementation of adaptive optics (AO) into OCT. The incorporation of AO into ophthalmic imaging modalities has enhanced OCT by improving image resolution and quality, particularly in the posterior ...

      Read Full Article
    12. Clinical Utility of Optical Coherence Tomography in Glaucoma

      Clinical Utility of Optical Coherence Tomography in Glaucoma

      Optical coherence tomography (OCT) has established itself as the dominant imaging modality in the management of glaucoma and retinal diseases, providing high-resolution visualization of ocular microstructures and objective quantification of tissue thickness and change. This article reviews the history of OCT imaging with a specific focus on glaucoma. We examine the clinical utility of OCT with respect to diagnosis and progression monitoring, with additional emphasis on advances in OCT technology that continue to facilitate glaucoma research and inform clinical management strategies.

      Read Full Article
    13. Optic Nerve Head Measurements With Optical Coherence Tomography: A Phantom-Based Study Reveals Differences Among Clinical Devices

      Optic Nerve Head Measurements With Optical Coherence Tomography: A Phantom-Based Study Reveals Differences Among Clinical Devices

      Purpose : Optical coherence tomography (OCT) can monitor for glaucoma by measuring dimensions of the optic nerve head (ONH) cup and disc. Multiple clinical studies have shown that different OCT devices yield different estimates of retinal dimensions. We developed phantoms mimicking ONH morphology as a new way to compare ONH measurements from different clinical OCT devices. Methods : Three phantoms were fabricated to model the ONH: One normal and two with glaucomatous anatomies. Phantoms were scanned with Stratus, RTVue, and Cirrus clinical devices, and with a laboratory OCT system as a reference. We analyzed device-reported ONH measurements of cup-to-disc ratio (CDR) and ...

      Read Full Article
    14. Virtual Averaging Making Nonframe-Averaged Optical Coherence Tomography Images Comparable to Frame-Averaged Images

      Virtual Averaging Making Nonframe-Averaged Optical Coherence Tomography Images Comparable to Frame-Averaged Images

      Purpose : Developing a novel image enhancement method so that nonframe-averaged optical coherence tomography (OCT) images become comparable to active eye-tracking frame-averaged OCT images. Methods : Twenty-one eyes of 21 healthy volunteers were scanned with noneye-tracking nonframe-averaged OCT device and active eye-tracking frame-averaged OCT device. Virtual averaging was applied to nonframe-averaged images with voxel resampling and adding amplitude deviation with 15-time repetitions. Signal-to-noise (SNR), contrast-to-noise ratios (CNR), and the distance between the end of visible nasal retinal nerve fiber layer (RNFL) and the foveola were assessed to evaluate the image enhancement effect and retinal layer visibility. Retinal thicknesses before and after processing ...

      Read Full Article
    15. IMAGING WITH MULTIMODAL ADAPTIVE-OPTICS OPTICAL COHERENCE TOMOGRAPHY IN MULTIPLE EVANESCENT WHITE DOT SYNDROME: THE STRUCTURE AND FUNCTIONAL RELATIONSHIP

      IMAGING WITH MULTIMODAL ADAPTIVE-OPTICS OPTICAL COHERENCE TOMOGRAPHY IN MULTIPLE EVANESCENT WHITE DOT SYNDROME: THE STRUCTURE AND FUNCTIONAL RELATIONSHIP

      Purpose: To elucidate the location of pathological changes in multiple evanescent white dot syndrome (MEWDS) with the use of multimodal adaptive optics (AO) imaging . Methods: A 5-year observational case study of a 24-year-old female with recurrent MEWDS. Full examination included history, Snellen chart visual acuity, pupil assessment, intraocular pressures, slit lamp evaluation, dilated fundoscopic exam, imaging with Fourier-domain optical coherence tomography (FD-OCT), blue-light fundus autofluorescence (FAF), fundus photography, fluorescein angiography, and adaptive-optics optical coherence tomography . Results: Three distinct acute episodes of MEWDS occurred during the period of follow-up. Fourier-domain optical coherence tomography and adaptive-optics imaging showed disturbance in the photoreceptor ...

      Read Full Article
    16. Predicting Development of Glaucomatous Visual Field Conversion Using Baseline Fourier-Domain Optical Coherence Tomography

      Predicting Development of Glaucomatous Visual Field Conversion Using Baseline Fourier-Domain Optical Coherence Tomography

      Purpose To predict the development of glaucomatous visual field (VF) defects using Fourier-domain optical coherence tomography (FD-OCT) measurements at baseline visit. Design Multi-center longitudinal observational study. Glaucoma suspects and pre-perimetric glaucoma participants in the Advanced Imaging for Glaucoma Study. Methods The optic disc, the peripapillary retinal nerve fiber layer (NFL), and macular ganglion cell complex (GCC) were imaged with FD-OCT VF was assessed every 6 months. Conversion to perimetric glaucoma was defined by VF pattern standard deviation (PSD) or glaucoma hemifield test (GHT) outside normal limits on 3 consecutive tests. Hazard ratios were calculated with the Cox proportional hazard model ...

      Read Full Article
    17. In Vivo Evaluation of White Matter Integrity and Anterograde Transport in Visual System After Excitotoxic Retinal Injury With Multimodal MRI and OCT

      In Vivo Evaluation of White Matter Integrity and Anterograde Transport in Visual System After Excitotoxic Retinal Injury With Multimodal MRI and OCT

      Purpose. Excitotoxicity has been linked to the pathogenesis of ocular diseases and injuries and may involve early degeneration of both anterior and posterior visual pathways. However, their spatiotemporal relationships remain unclear. We hypothesized that the effects of excitotoxic retinal injury (ERI) on the visual system can be revealed in vivo by diffusion tensor magnetic resonance imagining (DTI), manganese-enhanced magnetic resonance imagining (MRI), and optical coherence tomography (OCT). Methods. Diffusion tensor MRI was performed at 9.4 Tesla to monitor white matter integrity changes after unilateral N-methyl-D-aspartate (NMDA)-induced ERI in six Sprague-Dawley rats and six C57BL/6J mice. Additionally, four ...

      Read Full Article
    18. Histogram Matching Extends Acceptable Signal Strength Range on Optical Coherence Tomography Images

      Histogram Matching Extends Acceptable Signal Strength Range on Optical Coherence Tomography Images

      Purpose. We minimized the influence of image quality variability, as measured by signal strength (SS), on optical coherence tomography (OCT) thickness measurements using the histogram matching (HM) method. Methods. We scanned 12 eyes from 12 healthy subjects with the Cirrus HD-OCT device to obtain a series of OCT images with a wide range of SS (maximal range, 1–10) at the same visit. For each eye, the histogram of an image with the highest SS (best image quality) was set as the reference. We applied HM to the images with lower SS by shaping the input histogram into the reference ...

      Read Full Article
    19. Cardiac-Gated En Face Doppler Measurement of Retinal Blood Flow Using Swept Source Optical Coherence Tomography at 100,000 Axial Scans per Second

      Cardiac-Gated En Face Doppler Measurement of Retinal Blood Flow Using Swept Source Optical Coherence Tomography at 100,000 Axial Scans per Second

      Purpose: To develop and demonstrate a cardiac gating method for repeatable in vivo measurement of total retinal blood flow (TRBF) in humans using en face Doppler optical coherence tomography (OCT) at commercially available imaging speeds. Methods: A prototype swept-source OCT system operating at 100 kHz axial scan rate was developed and interfaced with a pulse oximeter. Using the plethysmogram measured from the earlobe, Doppler OCT imaging of a 1.5 mm×2 mm area at the optic disc at 1.8 volumes/sec was synchronized to cardiac cycle to improve sampling of pulsatile blood flow. Post-processing algorithms were developed to ...

      Read Full Article
    20. Evaluating glaucoma damage: emerging imaging technologies

      Evaluating glaucoma damage: emerging imaging technologies

      The use of ocular imaging tools to estimate structural and functional damage in glaucoma has become a common clinical practice and a substantial focus of vision research. The evolution of the imaging technologies through increased scanning speed, penetration depth, image registration and development of multimodal devices has the potential to detect the pathology more reliably and in earlier stages. This review is focused on new ocular imaging modalities used for glaucoma diagnosis.

      Read Full Article
    21. New developments in optical coherence tomography

      New developments in optical coherence tomography

      Purpose of review: Optical coherence tomography (OCT) has become the cornerstone technology for clinical ocular imaging in the past few years. The technology is still rapidly evolving with newly developed applications. This manuscript reviews recent innovative OCT applications for glaucoma diagnosis and management. Recent findings: The improvements made in the technology have resulted in increased scanning speed, axial and transverse resolution, and more effective use of the OCT technology as a component of multimodal imaging tools. At the same time, the parallel evolution in novel algorithms makes it possible to efficiently analyze the increased volume of acquired data. Summary: The ...

      Read Full Article
    22. In Vivo Three-Dimensional Characterization of the Healthy Human Lamina Cribrosa with Adaptive Optics Spectral-Domain Optical Coherence Tomography

      In Vivo Three-Dimensional Characterization of the Healthy Human Lamina Cribrosa with Adaptive Optics Spectral-Domain Optical Coherence Tomography

      Purpose: To characterize the in vivo 3D lamina cribrosa (LC) microarchitecture of healthy eyes using adaptive optics spectral-domain optical coherence tomography (AO-SDOCT). Methods: One randomly selected eye from each of 18 healthy subjects was scanned with Cirrus HD-OCT and AO-SDOCT centered on the optic nerve head. LC microarchitecture, imaged by the later device, was semi-automatically segmented and quantified for connective tissue volume fraction (CTVF), beam thickness, pore diameter, pore area and pore aspect ratio. The LC was assessed in central and peripheral regions of equal areas, quadrants and with depth. A linear mixed-effects model weighted by the fraction of visible ...

      Read Full Article
    23. Automated macular pathology diagnosis in three-dimensional (3D) spectral domain optical coherence tomography (SD-OCT) images

      Automated macular pathology diagnosis in three-dimensional (3D) spectral domain optical coherence tomography (SD-OCT) images

      Systems and methods of analyzing an optical coherence tomography image of a retina are discussed. A 2-dimensional slice of the image can be aligned to produce an approximately horizontal image of the retina and an edge map based at least in part on the aligned slice. Also, at least one global representation can be determined based on a (multi-scale) spatial division, such as multi-scale spatial pyramid, on the slice and/or edge map. Creating the local features is based on the specified cell structure of the global representation. The local features can be constructed based on local binary pattern (LBP ...

      Read Full Article
    1-24 of 87 1 2 3 4 »
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (86 articles) Gadi Wollstein
    2. (83 articles) Joel S. Schuman
    3. (78 articles) University of Pittsburgh
    4. (65 articles) Hiroshi Ishikawa
    5. (44 articles) Larry Kagemann
    6. (28 articles) Richard A. Bilonick
    7. (21 articles) Massachusetts Institute of Technology
    8. (20 articles) Carl Zeiss Meditec
    9. (18 articles) James G. Fujimoto
    10. (14 articles) Michelle L. Gabriele
    11. (3 articles) National Institutes of Health
    12. (2 articles) Harvard University
    13. (1 articles) Texas A&M University
    14. (1 articles) FDA
    15. (1 articles) University of Southern California
    16. (1 articles) Dresden University of Technology
    17. (1 articles) Francesco Prati
    18. (1 articles) Edmund Koch
    19. (1 articles) Lars Kirsten
    20. (1 articles) Javier A. Jo
  3. Popular Articles

  4. Picture Gallery

    Repeated, noninvasive, high resolution spectral domain optical coherence tomography imaging of zebrafish embryos The OCT penlight: in-situ image guidance for microsurgery Identification and Assessment of Schlemm's Canal by Spectral Domain Optical Coherence Tomography Automated Macular Pathology Diagnosis in Retinal OCT Images Using Multi-Scale Spatial Pyramid with Local Binary Patterns Optic Nerve Crushed Mice Followed Longitudinally with Spectral Domain Optical Coherence Tomography Optical Coherence Tomography: History, Current Status, and Laboratory Work 3D Visualization of Aqueous Humor Outflow Structures In-Situ in Humans Medical treatment of inflammatory punctual stenosis monitored by anterior segment optical coherence tomography Development and Validation of a Deep Learning System for Diagnosing Glaucoma Using Optical Coherence Tomography Methylene blue-filled biodegradable polymer particles as a contrast agent for optical coherence tomography Optical coherence tomography for thyroid pathology: 3D analysis of tissue microstructure Mathematical Analysis of Texture Indicators for the Segmentation of Optical Coherence Tomography Images